• 제목/요약/키워드: Temperature control unit

검색결과 405건 처리시간 0.028초

콘덴싱가스보일러 제어를 위한 공급수알고리즘 (The Supply Water Algorithm for a Condensing Gas Boiler Control)

  • 한도영;유병강
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.441-448
    • /
    • 2011
  • The energy consumption of a condensing gas boiler may be greatly reduced by the effective operation of the unit. In this study, the supply water algorithm for a condensing gas boiler control was developed by using the fuzzy logic. This includes the supply water set temperature algorithm, and the control algorithms of a gas valve, a blower and a pump. For the set temperature algorithm, the outside air temperature and the return water temperature were used as input variables. The supply water temperature difference and its slope were used as input variables of the gas valve and blower control algorithm. And the supply water temperature and the return water temperature were used as input variables of the pump control algorithm. In order to analyse performances of these algorithms, the dynamic model of a condensing gas boiler was used. The initial start-up test, the supply water set temperature change test, the outside air temperature change test, and the return water temperature change test were performed. Simulation results showed that algorithms developed in this study may be practically applied for the effective control of a condensing gas boiler.

Al고압주조공법에서 사출슬리브 온도 조절을 통한 Chill layer의 최적 제어 (Optimal Control of Chill layers through Regulation of Temperature on Shot Sleeve in Aluminum High Pressure Diecasting)

  • 박진영;김억수;박용호;박익민
    • 한국재료학회지
    • /
    • 제16권11호
    • /
    • pp.698-704
    • /
    • 2006
  • In this study, the effect of chill layers occurred in shot sleeve on the molten metal filling was analyzed through computer simulation. The behavior of chill layers with temperature variation of shot sleeve set from 200 to $280^{\circ}C$ was also investigated. The simulation results showed the chill layers set in the in-gates during the injection process change the main filling direction and cause turbulent flow pattern, resulting in porosities inside the castings. The amount of chill layers with the increasing temperature of shot sleeve was considerably reduced. Particularly, at the setting temperature of $280^{\circ}C$ by heat control unit, the biggest reduction in chill layers, excellent trimmed surface and the highest density were achieved, suggesting that as the optimal sleeve condition in aluminum high pressure diecasting, especially for highly complex parts like valve body.

냉난방 시스템의 이중선형 시스템에 관한 제어기 설계 (A Controller Design of the Bilinear System for HVAC(Heating, Ventilating and Air-conditioning) System)

  • 이정석;강민수;김명호;이기서
    • 한국철도학회논문집
    • /
    • 제3권4호
    • /
    • pp.177-184
    • /
    • 2000
  • In this paper, a HVAC controller which has a bilinear system is designed to control the air temperature in building room and a saving of energy on the HVAC system. For modeling of the HVAC bilinear system, AHU(Air Handling Unit) is modeled on the control of inside-outside air flow using three dampers in a duct. A heat exchanger and the single room are also modeled by the energy conservation law. Under the modeling of the HVAC bilinear system, the control's law of the bilinear HVAC system is derived by Lyapunov's non-linear theory and Deress's the linear feedback laws for bilinear system. In this paper it was proved that the controller of the HVAC bilinear system is able to control the air temperature with a disturbance in order to get a target of temperature in the building room by the computer simulation when the control inputs regulate the air flow rate and a capacity of the heat exchanger.

  • PDF

공동주택 세대별 난방 성능 개선 연구 (A Study on Improved Heating Performance of an Apartment Housing Unit)

  • 서정아;신영기;김용기;이태원
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

Flexible Flat Cable 생산성 향상을 위한 가압용 히팅롤러의 온도제어개선 (Temperature Control Improvement of Pressure Heating Roller for Flexible Flat Cable Production)

  • 김재학;이호중;전경진
    • 한국정밀공학회지
    • /
    • 제22권7호
    • /
    • pp.155-163
    • /
    • 2005
  • Pressure heating rollers with temperature control were mounted to a flat cable laminating machine (FCLM). Pressure heating rollers should be heated up to the setting temperature $(175^{\circ}C)$ and kept on to producing good quality flexible flat cables (FFC). Existing Pressure heating rollers took more than 70minutes to the setting temperature and did not keep on the setting temperature in production. Temperature controller, electric power controller, material and diameter of rollers and heat capacities were changed to improve the temperature control of the pressure heat rollers for better production of the FFC. Thus, the reaching time to the setting temperature (RT), temperature stability time (TST) and temperature hunting (TH) were measured and compared with the existing pressure rollers case. The RT of A roller was shortened by 50minutes, and B roller was shortened by 15minutes. The TST of A roller was shortened by 13minutes, and B roller was shortened by 15minutes. The THs of both A and B rollers were settled up to ${\pm}5^{\circ}C$. Finally, the productivity of the FCLM and the quality of the FFC were increased.

항공기 장착물에 탑재되는 KW급 전력변환장치의 방열설계 (Heat Dissipation Design for KW Class Power Control Unit Mounted on Aircraft Store)

  • 최석민;김형재;정재원;이철
    • 한국항행학회논문지
    • /
    • 제24권4호
    • /
    • pp.261-266
    • /
    • 2020
  • 항공기 장착물에 KW급 전력변환장치가 탑재되는 경우, 전력 변환 시 발생하는 대량의 발열에 대한 방열설계가 고려되어야 한다. 적절한 방열을 하지 못하는 경우, 장비 오작동 및 화재의 우려가 발생하며 이는 항공기 운항에 있어 치명적인 요인이 될 수 있다. 본 논문은 항공기 장착물에 탑재되는 KW급 전력변환장치의 방열설계에 관하여 기술하였다. 전산해석을 통한 설계 및 제작 후 시험을 수행하였으며, 고전력 변환에 따른 발열부품의 급격한 발열 현상을 확인하여 해석 모델을 보정하였다. 모델 보정 후 방열구조가 개선된 형상으로 설계를 개선하였으며, 미 군사규격인 MIL-STD-810G 의 고온동작 시험을 수행하여 개선된 형상의 타당성을 검증하였다.

전력선 통신(PLC)을 이용한 난방기기 제어 및 원격제어 시스템의 개발에 관한 연구 (A Study on the development of Heating Facility Control and Remote Control System using Power Line Communication (PLC))

  • 김용태;신관우;이윤섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.65-67
    • /
    • 2001
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter. The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance selective possibility of frequency property. This study designed the boiler temperature control system by unit using the modem designed on the basis of technology used for PLC modem, and designed remote control system using internet. After conducting experiments with those two systems, it was possible to control stably. By commercializing this product, we can avoid unnecessary heating of separate temperature control unit, and save the cost according1y, and it is possible to control on a remote site using internet in a more convenient way.

  • PDF

사출성형기의 사출온도에 대한 측정 불확도 추정 (Measurement Uncertainty Estimation of Injection Temperature in Injection Molding Machine)

  • 정현석;유중학
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.145-149
    • /
    • 2013
  • The performance of injection molding machine's control system, such as reproducibility, repeatability, etc, is widely studied nowadays. Since screw stroke, injection cylinder body pressure and barrel temperature are the most important terms of injection unit, interval linearity and repeatability to each parameter are analyzed here. Barrel temperature is analyzed according to the repeatability of the thermocouple at $150^{\circ}C$, $210^{\circ}C$, $300^{\circ}C$ using a precise oven. The result temperature is within ${\pm}0.5^{\circ}C$ Through the reliability evaluation of the most important terms of injection unit, the method of evaluating the linearity and repeatability is proposed and verified.

위성에 탑재된 상변화물질 열제어장치 비행모델의 열진공시험 및 이를 통한 열해석 모델 보정 (Thermal Vacuum Test of the Phase Change Material Thermal Control Unit Loaded on the Satellite Flight Model and Thermal Model Correlation with Test Results)

  • 조연;김택영;서정기;장태성;박홍영
    • 한국항공우주학회지
    • /
    • 제50권10호
    • /
    • pp.729-737
    • /
    • 2022
  • 하반기에 발사 예정인 차세대소형위성2호(NEXTSat-2)에 탑재된 고상-액상 상변화물질 열제어장치(Phase Change Material Thermal Control Unit, PCMTCU)의 비행모델에 대한 위성 차원 열진공시험 결과로부터 융해-응고에 따른 작동과정을 분석하였다. 시험결과 PCM의 상변화는 발열부품의 온도 안정화에 기여함을 확인하였다. 시험에서 계측된 온도변화를 이용하여 타당한 정도의 정확도를 갖도록 PCMTCU의 열해석모델에 대한 보정을 수행하였다. 보정된 열해석모델로써 임무궤도의 정상 작동에 따른 PCMTCU의 주기적 온도변화를 예측하였으며, PCM의 액상분율로써 정량적 기여도를 평가하였다. 향후 임무궤도에서의 비행자료를 수신하여 PCMTCU의 우주 환경 검증을 완료할 예정이다.