• 제목/요약/키워드: Temperature coefficient

검색결과 4,538건 처리시간 0.029초

저항 온도계수와 방열 구조설계에 따른 션트 고정 저항의 전기적 특성 (Electrical Properties of Temperature Coefficient of Resistance and Heat Radiation Structure Design for Shunt Fixed Resistor)

  • 김은민;김현창;이선우
    • 한국전기전자재료학회논문지
    • /
    • 제31권2호
    • /
    • pp.107-111
    • /
    • 2018
  • In this study, we designed the temperature coefficient of resistance (TCR) and heat radiation properties of shunt fixed resistors by adjusting the atomic composition of a metal alloy resistor, and fabricated a resistor that satisfied the designed properties. Resistors with similar atomic composition of copper and nickel showed low TCR and excellent shunt fixed resistor properties such as short-time overload, rated load, humidity load, and high temperature load. Finally, we expect that improved sensor accuracy will be obtained in current-distribution-type shunt fixed resistor for IoT sensors by designing the atomic composition of the metal alloy resistor proposed in this work.

The Characteristics of a Pump at Nearly Saturated State

  • Kim, S. N.;Kim, J. C.
    • Nuclear Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.40-46
    • /
    • 1998
  • A set of experiments using a 1/10 scale model pump which was manufactured to simulate performance of reactor coolant pump(RCP) of Y.G.N # 3 and 4, was executed in single phase(at atmospheric pressure and room temperature) and near-saturation(300 ~ 600kPa). The pump characteristics in single phase flow was similar to the characteristics of the RCP. The pump characteristic curves at nearly saturated state were correlated in terms of flow coefficient and head coefficient for subcooled temperature using the cavitation number defined as (equation omitted), which can be predicted the cavitation possibility. The pump behavior around the saturated temperature almost consists with single phase behavior until the cavitation occurs(When cavitation occurs. When the flow coefficient is about 0.12), the pump head rapidly degrades. In this situation, subcooled temperature is about 1.8~8$^{\circ}C$ and cavitation number of model pump is 1.0 ~ 1.7.

  • PDF

주위의 열대류계수가 다를때 사각핀으로부터의 열손실에 대한 비대칭적인 핀바닥온도의 영향 (Effect of Asymmetric Root Temperature on the Heat Loss From a Rectangular Fin Under Unequal Surrounding Heat Convection Coefficient)

  • 강형석;김성준
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1567-1571
    • /
    • 1994
  • Under the assumption that thermal conductivity of the fin is constant and the conditions ate steady state, effects of non-constant and thermally asymmetric root temperature and unequal surrounding convection coefficients of the fin on the heat loss from a fin of rectangular profile are investigated. The heat loss form a rectangular fin becomes maximum when the highest root temperature deviates from the fin center to the fin side which has a higher convection coefficient as surrounding convection coefficients of the fin increase and as the difference between the convection coefficient of fin top side and that of fin bottom side increases.

다아나모 실험을 통한 Al-MMC 브레이크 드럼의 제동성능 평가 (The Braking Performance Evaluation of Al-MMC Brake Drum Using the Dynamometer)

  • 윤영식;유승을;한범석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.733-736
    • /
    • 2002
  • This study was carried out to investigate the braking performances associated with the friction coefficients and temperature fluctuations. Friction coefficient stability and maximum temperature of brake drums, made of an Al-MMC and conventional cast iron, were tested by the inertial brake dynamometer during 15 braking operations. Also the temperature distribution was analyzed by the finite element analysis(FEA). In this experiment, both lower temperature rise near the drum surface and less variation of friction coefficient, compared to those of cast iron, were observed with Al-MMC drums during braking operations.

  • PDF

Mn-Mg-Fe 계 산화물 조성의 저항-온도 특성 (Resistivity-Temperature Properties of Mn-Mg-Fe Oxide Systems)

  • 이승관;김종령;오영우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.407-410
    • /
    • 2000
  • (M $n_{l-x}$M $g_{l-x}$)F $e_{2+x}$ $O_4$(x=0.0, 0.025, 0.1, 0.2) for NTC(negative temperature coefficient) thermistor was prepared by calcining at 80$0^{\circ}C$ and sintering at from 1100 to 130$0^{\circ}C$ with 5$0^{\circ}C$ intervals while x was varied from 0.0 to 0.025, 0.1 and 0.2. The best linear property was obtained in the based specimen sintered at 120$0^{\circ}C$ with x=0.1 composition. Thermistor parameter, $B_{25~85^{\circ}C}$, was in the range of 5000~ 7300 [K]. Temperature coefficient of resistance, $\alpha$$_{25^{\circ}C}$, was -5.2 %/$^{\circ}C$. The results showed the possibility that Mn-Ni-Co based thermistor could be substituted by the composition used in this study was confirmed.med.d.

  • PDF

금속박막형 압력센서의 제작 (Fabrication of Metal Thin-Film Type Pressure Sensors)

  • 최성규;김병태;남효덕;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.587-590
    • /
    • 2000
  • This paper presents the characteristics of metal thin-film pressure sensors. The micro pressure sensors consists of a chrom thin-film, patterned on a Wheatstone bridge configuration, sputter-deposited onto thermally oxidized Si wafer an aluminium interconnection layer. The fabricated micro pressure sensors shows a low temperature coefficient of resistance, high-sensitivity, low non-linearity and excellent temperature stability. The sensitivity is 1.16~1.21 mV/V.kgf/$\textrm{cm}^2$ in the temperature range of 25~l0$0^{\circ}C$ and the maximum non-linearity is 0.21 %FS.

  • PDF

The Practical Method and Experimental Verification of Temperature Estimation in the Permanent Magnet of Electric Machine

  • Kang, Kyongho;Yu, Sukjin;Lee, Geunho;Lee, Byeong-Hwa
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.421-426
    • /
    • 2015
  • This paper presents a practical method for estimation of average temperature in the permanent magnet (PM) of electric machine by using finite element analysis (FEA) and dynamo load experiment. First of all, the temperature effect of PM to the torque has been employed by FEA in order to evaluate the Temperature-Torque characteristic curve. The 1st order polynomial equation which is torque attenuation coefficient is derived by the FEA result of the Temperature-Torque curve. Next, torque saturation test with constant current condition is performed by dynamo load experiment. Then, the temperature trend can be estimated by adding the initial starting temperature using the torque attenuation coefficient and torque saturation curve. Lastly, estimated temperature is validated by infrared thermometer which measures temperature of PM surface. The comparison between the estimated result and experimental result gives a good agreement within a deviation of maximum $8^{\circ}C$.

A Basic Study on the Variation of Temperature Characteristics for Attenuation Coefficient and Sound Velocity in Biological Tissues

  • Park, Heung-Ho
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권3호
    • /
    • pp.273-282
    • /
    • 1993
  • This study is concerned with the temperature dependence characteristics of ultrasound parameters in biological tissues, which are basic on the noninvasive deep body temperature estimation. Used parameters are ultrasonic attenuation coefficient and sound velocity In order to accomplishment our purpose, several signal processing methods were used. Attenua4iorl coefficient was estimated by spectral difference method and sound velocity was estimated by P-P method. And we also examined these methods through a series of IN VITRO experi mentis that used tissue-mimicking phantom samples and biological tissue samples. In order to imitate the biological soft tissue two kinds of phantom samples are used, one is agar phantom sample which is composed of agar, graphite, N-propyl alcohol and distilled water, and the other is fat phantom sample which is composed of pure animal fat. And the ultrasound transmission mode and reflection mode experiments are performed on the pig's spleen, kidney and fat. As a result, it is found that the temperature characteristics are uniform in case of phan- tom samples but not in biological tissues because of complicate wave propagation within them. Consequently, the possibility of temperature measurement using ultrasound on biological tissue is confirmed and its results may contribute to the establishment of reference values of internal temperature measurement of biological tissues.

  • PDF

치과용 지르코니아 도재의 Li2O 첨가에 따른 열팽창계수 변화 (A Change of Thermal Expansion Coefficient according to Li2O-added Porcelain for Dental Zirconia)

  • 한석윤
    • 대한치과기공학회지
    • /
    • 제31권4호
    • /
    • pp.25-30
    • /
    • 2009
  • Zirconia($ZrO_2$) has attracted much attention in science and technology because of its high refractive index, high melting temperature, hardness, low thermal conductivity and corrosion barrier properties. And it is widely used as the dental restoration material because of its esthetic appearance. In this research, we analyzed the particle size and composition of the imported dental porcelain for zirconia. And the glass frit was produced. To decrease the glass transition temperature and softening temperature of the glass frit, $Li_2O$ was added into it and the effect of $Li_2O$ on the firing temperature was researched. Then the glass which contains leucite crystal with a high coefficient of thermal expansion(CTE) was manufactured and it was mixed with the glass frit to control the CTE. The phase composition were analyzed using the X-ray diffraction. The morphologies of the samples were observed by the scanning electron microscope. The 4wt% $Li_2O$-added glass frit has the optimal glass transition temperature and softening temperature. And 6 wt% leucite crystal was mixed with the glass frit to control the CTE. From the experimental results of crystallization, the crystal phase was found only leucite crystal.

  • PDF

초고압 전력기기의 온도상승 예측 (Prediction of Temperature Rise in Power Appratus)

  • 김승욱;박정홍;한성진;이병윤;박경엽;송원표;김정배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.113-115
    • /
    • 2001
  • In order to design the power appratus such ac bus bar, the current carrying ampacity should be determined, Since it is limited by maxium operating temperature, it is very important to predict temperature-rise on it. The main causes to raise temperature are joule's loss in the current carrying conductor and induced circulating and eddy current in the tank. The heat transfer is divided into convection and radiation on boundary, determining convection heat transfer coefficient is not easy. This paper propose a new technique that can be used to estimate the temperature rise in the extra high voltage bus bar. The heat transfer coefficient is analytically calculated by applying Nusselt Number depending on temperature as well as model geometry. The analytic method which use heat transfer coefficient is coupled with finite element method. The temperature distribution in the bus bar by the proposed method shows good agreement with experimental data.

  • PDF