• 제목/요약/키워드: Temperature coefficient

검색결과 4,538건 처리시간 0.029초

광릉수목원 혼합림에서 복사 에너지의 계절 변화 특성 (Characteristics of the Seasonal Variation of the Radiation in a Mixed Forest at Kwangneung Arboretum)

  • 김연희;조경숙;김현탁;엄향희;최병철
    • 한국대기환경학회지
    • /
    • 제19권3호
    • /
    • pp.285-296
    • /
    • 2003
  • The measurement of the radiation energy, trunk temperature, leaf area index (LAI), air temperature, vapor pres-sure, and precipitation has been conducted under a mixed forest at Kwangneung Arboretum during the period of 2001. Characteristics of the diurnal and seasonal variation of the radiative energy were investigated. The aerodynamic roughness length was determined as about 1.6 m and the mean albedo was about 0.1 The downward short-wave radiation was linearly correlated with the net radiation and its correlation coefficient was about 0.96. From this linear relation, the heating coefficient was calculated and its annual mean value was about 0.21 The albedo and heating coefficient was varied with season, surface characteristics, and meteorological conditions. The diurnal and seasonal variations of radiation energy were discussed in terms of the surface characteristics and meteorological conditions. In the daytime, during clear skies, net radiation was dominated by the shortwave radiation. In presence of clouds and fog, the radiation energy was diminished. At night, the net radiation was entirely dominated due to the net longwave radiation. There was no distinct diurnal variation in net radiation flux during the overcast or rainy days. The net radiation was strongest in spring and weakest in winter. The seasonal development in leaf area was also reflected in a strong seasonal pattern of the radiation energy balance. The timing, duration, and maximum leaf area and trunk temperature were found to be an important control on radiation energy budget. The trunk temperature was either equal or warmer than air temperature during most of the growing season because the canopy could absorb a substantial amount of sunlight. After autumn (after the middle of October), the trunk temperature was consistently cooler than air temperature.

양생조건·외기온도·비등효과를 고려한 콘크리트 외기대류계수의 결정 (Determination of Convection Heat Transfer Coefficient Considering Curing Condition, Ambient Temperature and Boiling Effect)

  • 최명성;김윤용;우상균;김진근
    • 콘크리트학회논문집
    • /
    • 제17권4호
    • /
    • pp.551-558
    • /
    • 2005
  • 이 연구에서는 외기와의 열전달을 나타내는 외기대류계수에 관한 실험을 실시하였다. 외기대류계수에 관한 기존의 모델에서 나타났던 문제점을 해결하기 위해 실험 변수로 풍속외에 양생 조건의 종류(양생포, 양생포+비닐), 외기온도, 비등효과를 선정하였다. 실험 결과를 이용하여 외기대류계수를 산정하고자 열평형 방정식을 이용한 수치해법을 사용하였으며, 이론적인 고찰을 통해 각 양생 조건별로 풍속에 따른 외기대류계수의 변화를 예측할 수 있는 모델식을 제안하였다. 열평형 방정식을 이용한 수치해법에서 초기에 외기대류계수가 과잉평가되는 문제점을 해결하기 위해 비등효과에 의한 증발량을 고려하여 수정 열평형 방정식을 제안하였다. 양생 조건을 고려한 제안된 모델식에 의하면, 모든 경우에 풍속에 따라 외기대류계수가 증가하는 경향을 보였으나 양생 재료의 사용여부나 양생 조건에 따라 다른 양상을 보이는 것을 알 수 있었다. 이러한 양상의 차이는 양생 재료의 열 특성에 의해 결정되는 것으로 외기대류계수는 양생 재료가 없는 경우, 양생포를 사용한 경우, 양생포+비닐을 사용한 경우의 순으로 풍속의 영향을 받는 것으로 나타났다. 제안된 모델식을 이용하면 수화열에 의한 콘크리트 구조물의 온도해석시 보다 정확한 결과를 얻을 수 있을 것으로 사료되며, 향후 이러한 열특성계수에 대한 연구가 필요할 것으로 판단된다.

적외선 화상처리 장치를 이용한 건조초기 목재 표면 온도 측정 (Measuring Temperature on Wood Surface at the Beginning of Drying Using IR Image Measuring System)

  • 이관영;강호양;이민경
    • 한국가구학회지
    • /
    • 제17권3호
    • /
    • pp.79-85
    • /
    • 2006
  • Temperature of board surface was monitored during drying using an IR image measurement system. Boards were water-saturated and dried at the levels of four temperatures and three air velocities. At higher DB the surface temperature increased more steeply and level off period was significantly short. At the DB temperatures of 70, 80, $90^{\circ}C$ the period where the surface temperature was equivalent to WB temperature was constant regardless of air velocity while at $60^{\circ}C$ it decreased as air velocity increased. It was confirmed that a surface transfer coefficient increased with DB temperature. Variation of temperature profile on a wood surface increased with DB temperature and air velocity.

  • PDF

반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성 : 분사비의 영향 (Film Cooling from Two Rows of Holes with Opposite Orientation Angles: Blowing Ratio Effects)

  • 안준;정인성;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.113-118
    • /
    • 2000
  • Experimental results describing the effects of blowing ratio on film cooling from two rows of holes with opposite orientation angles are presented. The inclination angle was fixed at $35^{\circ}$ and the orientation angles were set to be $45^{\circ}$ for downstream row. and $-45^{\circ}$ for upsream row. The studied blowing ratios were 0.5, 1.0 and 2.0. The boundary layer temperature distributions were measured using thermocouple at two downstream loundary layer temperature distributions were measured using thermocouple at two downstream locations. Detailed adiabatic film cooling effectiveness and heat transfer coefficient distributions were measured with TLC(Thermochromic Liquid Crystal). The adiabatic film cooling effectiveness and heat transfer coefficient distributions are discussed in connection with the injectant behaviors inferred from the boundary layer temperature distributions. Film cooling performance, represented by heat flux was calculated with the adiabatic film cooling effectiveness and heat transfer coefficient data.

  • PDF

소형 슬러시 제조기의 전열현상에 관한 연구 (Heat Transfer Characteristics of Small Slush Maker)

  • 김도영;김내현;오왕규;최용민;변호원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.346-350
    • /
    • 2008
  • Tests were conducted to obtain heat transfer coefficients during slush formation from 10% sucrose solution. The slush was made by scraping the ice formed on the cylinder. Cold brine was supplied inside of the cylinder to cool the outer surface. Below a certain brine temperature, which was $5^{\circ}C$ in this study, the solution was supercooled, and suddenly turned into ice. The super-cooling increases as the brine temperature increased. During slush formation, the heat transfer coefficient oscillated significantly, due to periodic removal of ice chunk form the surface. The average heat transfer coefficient during slush formation was approximately twice of that obtained during single phase cooling. The heat transfer coefficient was also affected by the brine temperature with increasing heat transfer coefficient at lower brine temperature.

  • PDF

$(Pb_{1-x}Ca_x)ZrO_3$$(Pb_{0.63},Ca_{0.37-x}M_x)ZrO_3$ 세라믹스의 고주파 유전 특성 (Microwave Dielectric Properties of $(Pb_{1-x}Ca_x)ZrO_3$ and $(Pb_{0.63},Ca_{0.37-x}M_x)ZrO_3$ (M = Mg, Sr) Ceramics)

  • 윤중락;이헌용
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권6호
    • /
    • pp.533-540
    • /
    • 1997
  • The microwave dielectric properties of ((P $b_{1-x}$ C $a_{x}$)Zr $O_3$ and (P $b_{0.63}$,C $a_{0.37-x}$ $M_{x}$)Zr $O_3$(M=Mg,Sr) ceramics were investigated. In (P $b_{1-x}$ C $a_{x}$)Zr $O_3$ (X=0.33~0.40) ceramics, high quality factor and small temperature coefficient of resonant frequency were obtain in (P $b_{0.63}$C $a_{0.37}$)Zr $O_3$with perovskite structure. In the case of (P $b_{0.63}$C $a_{0.37-x}$M $g_{x}$)Zr $O_3$ dielectric constant temperature coefficient of resonant frequency increased and quality factor decreased due to increase of polarization of A-O bonding. When replacing Ca ion with Sr ion with large ion radius, polarization decreased with increased of bonding length and thus dielectric constant and temperature coefficient of resonant frequency decreased.decreased.creased.

  • PDF

무급유공기압축기 개발을 위한 PTFE계 복합재료의 마찰마모 특성에 관한 연구 (A Study on the Effects of Friction and Wear Properties of PTFE Composites for Oil Free Air Compressor)

  • 김용직;정하돈;김윤해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.67-74
    • /
    • 2000
  • Recently, PTFE-polymide composites are being used self-lubricating parts for industrial field. Thus, this study is mainly concerned with friction and wear properties for the piston ring of non-lubricating air compressor which made of PTFE-polymide composites. The friction and wear test was carried out for the different composition ratio under the atomsphere room temperature and constant load of 7.69N and their friction and wear properties were compared with each other at various sliding speed. notable results are summarized as follows. PTFE 100% showed that friction coefficient was almost same values at 0.94 and 1.88m/s but the value was decreased at 2.83m/s because the friction temperature is higher than low speed. PTFE 80%-PI 20% showed the lowest mean friction coefficient at 2.83m/s. PTFE 20-PI 80% showed the highest friction coefficient at 0.94m/s and the value was decreased at high speed but the value is higher than other materials except PTFE 100 %. PI 100% showed the highest friction coefficient at 0.94 and 1.88m/s becuase adhesive wear mainly occurred that speed. PTFE 100% showed highest specific wear rate on the whole. Specific wear rate of PTFE 80%-PI 20% was almost the same value with PTFE 20%-PI80%. PI 100%showed the lowest value at high sliding speed because the friction surface was thicken and carbonated by high friction temperature.

  • PDF

물의 T-s 선도 상에서 26 종류의 물성치 작도 및 시스템 해석 프로그램 개발 (Program Development for Drawing of 26 Properties and System Analysis on T-s Diagram of Water or Vapor)

  • 김덕진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.157-164
    • /
    • 2008
  • The temperature-entropy diagram of water or vapor displays graphically the thermophysical properties, so it is very conveniently used in various thermal systems. On general T-s chart of water, there are temperature, pressure, quality, specific volume, specific enthalpy, specific entropy. However, various state and process values besides above properties can be plotted on T-s diagram. In this study, we developed the software drawing twenty six kinds of properties, that is temperature, pressure, quality, specific volume, specific internal energy, specific enthalpy, specific entropy, specific exergy, exergy ratio, density, isobaric specific heat, isochoric specific heat, ratio of specific heat, coefficient of viscosity, kinematic coefficient of viscosity, thermal conductivity, prandtl number, ion product, static dielectric constant, isentropic exponent, velocity of sound, joule-thomson coefficient, pressure coefficient, volumetric coefficient of expansion, isentropic compressibility, and isothermal compressibility. Also, this software can analyze and print the system values of mass flow rate, volume flow rate, internal energy flow rate, enthalpy flow rate, entropy flow rate, exergy flow rate, heat flow rate, power output, power efficiency, and reversible work. Additionally, this software support the functions such as MS-Power Point.

  • PDF

엔진구동 지열 열펌프의 성능 분석(II) - 소형 증기압축식 열펌프의 성능 분석 - (Performance Analysis of an Earth Coupled Heat Pump System Operated by an Engine(II) - Performance Analysis of a Vapour Compression type Compact Heat Pump -)

  • 김영복;송대빈;손재길
    • Journal of Biosystems Engineering
    • /
    • 제24권6호
    • /
    • pp.501-512
    • /
    • 1999
  • In this study, the coefficient of performance of a vapour compression heat pump system was analyzed for the evaluation of the heat pump performance. A water-to-air heat pump was assembled and tested by changing the level of the compressor driving speed and the air mass flow rate during air heating process. The coefficient of performance for air heating was 2.6~3.8 and that for water cooling was 1.0~1.4. The coefficient of performance was not depending on the levels of the compressor driving speed or levels of the air mass flow rate, but on the temperature of the air and water. The coefficient of performance for air heating increased by about 0.2 with the water temperature increasing by 1$^{\circ}C$.

  • PDF

엔진 냉각 시스템 개선에 관한 연구 (A Study on Improvement of Engine Cooling System)

  • 김문헌;오병욱
    • 한국자동차공학회논문집
    • /
    • 제2권2호
    • /
    • pp.103-116
    • /
    • 1994
  • In this study the behavior of engine cooling loss and overall heat transfer coefficient were studied experimentally using naturally aspirated engine and turbo charged engine. Using turbo charging, heat dissipation was increased because of the density of the mixture was increased with increment of inlet air flow rate. Therefore, cooling loss of turbo charged engine is larger than naturally aspirated engine. As taking the measurement of surface temperature of combustion chamber, gas heat transfer coefficient was calculated and found that it has greatly affected to overall heat transfer coefficient. The empirical formula of overall heat transfer coefficient established in order to predict of engine cooling loss and express only as a function of mean piston velocity.

  • PDF