• Title/Summary/Keyword: Temperature classification

Search Result 427, Processing Time 0.037 seconds

Variations of Ozone and PM10 Concentrations and Meteorological Conditions according to Airflow Patterns of their High Concentration Episodes on Jeju Island (제주지역 오존 및 미세먼지 고농도일의 기류패턴에 따른 농도변화와 기상조건 분석)

  • Han, Seung-Bum;Song, Sang-Keun;Choi, Yu-Na
    • Journal of Environmental Science International
    • /
    • v.26 no.2
    • /
    • pp.183-200
    • /
    • 2017
  • The classification of airflow patterns during high ozone ($O_3$) and $PM_{10}$ episodes on Jeju Island in recent years (2009-2015), as well as their correlation with meteorological conditions according to classified airflow patterns were investigated in this study. The airflow patterns for $O_3$ and $PM_{10}$ were classified into four types (Types A-D) and three types (Types E-G), respectively, using the HYbrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model and synoptic weather charts. Type A was the most dominant airflow pattern for $O_3$ episodes, being characterized by the transport of airflows from urban and industrial areas in China with the highest frequency (about 69%, with a mean of 67 ppb). With regard to the $PM_{10}$ episodes, Type E was the most dominant airflow pattern, and was mostly associated with long distance transport from Asian dust source regions along northwesterly winds, having the highest frequency (about 92%, with a mean of $136{\mu}g/m^3$). The variations in the concentration of $O_3$ and $PM_{10}$ during the study period were clarified in correlation with two pollutant and meteorological variables; for example, the high (low) $O_3$ and $PM_{10}$ concentrations with high (low) air temperature and/or wind speed and vice versa for precipitation. The contribution of long-range transport to the observed $PM_{10}$ levels in urban sites for different airflow patterns (Types E-F), if estimated in comparison to the data from the Gosan background site, was found to account for approximately 87-93% (on average) of its input. The overall results of the present study suggest that the variations in $O_3$ and $PM_{10}$ concentrations on Jeju Island are mainly influenced by the transport effect, as well as the contribution of local emissions.

Composting of Swine Feces Using Sawdust, Rice Straw Rice Hull or Newspaper as a Bulking Material (톱밥, 볏짚, 왕겨 및 신문지를 이용한 돈분의 퇴비화)

  • 최경호;박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.1
    • /
    • pp.56-67
    • /
    • 1995
  • This study was carried out to observe how composting reaction proceed in the optimum composting condition and to understand the characteristics of final compost, when swine feces was amended with different bulking material. Sawdust, rice straw, and rice hull were selected as bulking materials and each of these was mixed with swine feces to obtain the optimum range of moisture contents and C:N ratio. To grasp the influence of newspaper on cornposting reaction when it flew into the composting site intentionally or accidentally, another composting reaction using newspaper as a bulking material was studied. In this experiment, raw material mixes containing the same amount of organic materials were put into 4 composting reactors and composted in the same environmental condition for 3 weeks from Aug. 1, 1994 to Aug. 22, 1994. The followings are the main results of this study. 1. The maximum temperatures reached at during cornposting reaction were 53.8$\circ$C, 51.9$\circ$C, 52.7$\circ$C, and 52.1$\circ$C in the reactor using sawdust, rice straw, rice hull, and newspaper as a bulking material respectively: Thermophilic temperatures were maintained for 72, 108, 108, and 111 hours in each reactor. Mean temperatures of reactors using sawdust, rice straw, rice hull, or newspaper as a bulking materials were 39.7$\circ$C, 39.5$\circ$C, 41.3$\circ$C, and 40.3$\circ$C, but no significant difference between these mean temperatures was observed(p>0.05). Each composter showed significant difference from room temperature(p<0.01), and the mean difference between them was 9.4$\circ$C. 2. Ash contents of each reactor increased rapidly in order of rice straw, rice hull, newspaper, and sawdust according to the pattern of second order function. This rate of increase seemed to result from structural characteristics of a bulking material. The absolute values of second order coefficient of these regression functions were 0.0199, 0.0159, 0.0157, and 0.0144 in each reactor using rice straw, rice hull, newspaper, or sawdust as a bulking material. 3. C:N ratio decreased as the reaction proceeded. Degree of decrease was in order of rice straw, rice hull, newspaper, and sawdust. This sequence was consistent with the increase rate of ash content. The ratios of initial C:N ratio to final C:N ratio were 0.45, 0.53, 0.64, and 0.75 in each reactor using rice straw, rice hull, newspaper, and sawdust as a bulking material respectively. From this ratios, it was possible to infer that all the composting reactions were completed. 4. Fertilizer content containing in the final compost was 1.61~2.20% of N, and 0.35~0.54% of P in dry weight base. According to the classification standard for compost constituent by Higgins, all composts had the intermediate grade of N, but below the low grade of P excepting the newspaper amended compost(fall into the range of the low grade). 5. Heavy metal contents contained in the composts were analyzed. In case of Cd, the range of 0.58~1.11 $\mu$g/g was observed, and in case of Pb, the range of 24.76~39.53 $\mu$g/g was observed(in wet weight base). These values are below the permissible heavy metal level for compost of foreign countries.

  • PDF

Studies on the Optimal Conditions of Feeding and Light Supply for the Long-Term Cultivation of Meiofauna in the Laboratory (중형저서동물의 실험실 내 장기 배양을 위한 먹이 및 광원의 최적 조건 연구)

  • SHIN, AYOUNG;KIM, DONGSUNG;KANG, TEAWOOK;OH, JE HYEOK
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.25 no.2
    • /
    • pp.26-41
    • /
    • 2020
  • In order to culture a life for the physiological and ecological research of the meiofauna, this study aimed to identify the most ideal condition in which the meiofauna can be cultured within a laboratory by setting various environmental conditions. The sediment deposits and seawater were collected from the intertidal zone in Mallipo of the west coast. A aquarium in which the internal environment can be controlled by constantly maintaining the temperature and humidity was fabricated and the culture experiments of the collected meiofauna were conducted together with the sea water and sediment deposits collected. The experiment 1 was conducted after establishing the similar environment as the collecting location. Under the same condition as the experiment 1, the experiment 2 verified a difference between when live foods were supplied and were not. In the experiment 3, the changes in the meiofauna colony were checked according to with or without light and live foods. In the results of culturing experiments, the habitat density and the number of appeared classification groups of the meiofauna colony were relatively higher both in the water tank with supplying the live foods and under the condition of having light in 12-hour cycle than those in the aquarium without live foods and under no light condition. In addition, the habitat density of meiofauna cultured within a laboratory exhibited relatively higher value than that under the natural state.

Fluctuation of the Catch by the Set Net Fishery (정치망어업의 어획량변동에 관한 연구)

  • 장호영
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.4
    • /
    • pp.177-183
    • /
    • 1987
  • The catch by the set net fishery from 1971 to 1985 were analyzed in order to reveal its fluctuation characteristics. Generally, the catch increased from 16,787M/T in 1971 to 84,103M/T in 1985 and showed maximum in 1979 with 99,475M/T of catch. This trend was mainly related to the higher production of file fish which accounts for 64% of the total catch in 1979, and the change of catch statistical classification according to the revising of fishery law in 1976. It was also closely related to the variation of the sea water temperature in coastal area. The main fishing period of the set net fishery appeared from October to November. Catch of the set net fishery was led by that in the southern coast before 1976 and by that in the eastern coast from 1977 to 1980, the tendency changed irregular from 1981. Three groups of fishes could be distinguished by principal component analysis of the annual catch. A group showing steady decreasing tendency was composed of the fishes such as whiting, sand fish, hair tail and anchovy. The another group composed of small alaska pollack, round herring, goby, gizzard shad, sand lance and file fish revaled an increasing tendency. The other fishes did not show any annual tendency.

  • PDF

Hydrolytic and Metabolic Capacities of Thermophilic Geobacillus Isolated from Litter Deposit of a Lakeshore (수변 낙엽퇴적층에서 분리한 호열성 Geobacillus의 물질 분해 특성)

  • Baek, Hyun-Ju;Zo, Young-Gun;Ahn, Tae-Seok
    • Korean Journal of Microbiology
    • /
    • v.45 no.1
    • /
    • pp.32-40
    • /
    • 2009
  • To understand contribution of thermophilic microorganisms in decomposition of litter deposits on shore of lakes, we surveyed a lakeshore litter deposit for bacteria growing at $60^{\circ}C$. Ten thermophilic isolates were selected for in-depth characterization, based on their high capacity to degrade high molecular weight organic compounds. Based on phylogenetic analysis on their 16S rRNA gene sequences, all isolates were identified as Geobacillus. The optimal growth temperature and pH of the strains ranged $55{\sim}60^{\circ}C$ and 6.0${\sim}$8.0, respectively. Salinity was inhibitory to the growth of the isolates, showing marked decrease of growth rates at 3% salinity. Based on activities of hydrolytic enzymes and profiles of carbohydrate utilization (determined by API 50 CHB kit), three G. stearothermophilus strains showed patterns clearly distinctive from other isolates. Two G. kaustophilus strains also demonstrated distinctiveness in their metabolic pattern and ecological parameters. However, ecological and metabolic profiles of the other five isolates were more variable and showed some degree of digression from their phylogenetic classification. Therefore, it could be concluded that endospore-forming thermophilic bacteria in lakeshore litter deposits contribute to degradation of organic materials with diverse ecological niches while having successions similar to microbial flora in compost. We propose that the thermophilic isolates and/or their thermo-tolerant enzymes can be applied to industrial processes as appropriate mixtures.

A Comparative Analysis and Improvement of the Fractional Distillation Experiments in the Middle School Science Textbooks (중학교 과학 교과서 분별 증류 실험의 비교 분석 및 개선)

  • Ryu, Oh Hyun;Choi, Moon Young;Song, Ju Hyun;Kwon, Jung Geun;Paik, Seoung Hey;Park, Kuk Tae
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.5
    • /
    • pp.481-490
    • /
    • 2001
  • The purpose of this study was to find out the problems on the fractional distillation experiments in the middle school science textbooks based on the 6th curriculum and to suggest an efficient experiment method for the middle school students. The first step was the classification of the experiments in 8 science textbooks according to heating apparatus and liquid mixtures. The second step was doing each experiment 3 times followed by the experimental process in the textbooks. The third step was developing the alternative experiments for solving the problems found in the second step. The heating method used in the alternative experiments were direct heating, oil bath, and heating mantle. The results of the second step showed that the direct heating experiment of branched round flask was more close to the theoretical prediction than the experiment of water bath heating of branched test tube. Also the direct heating experiment of thermally insulated branched round flask was better than the result of the experiment which was not insulated. The results of the third step showed that the experiment using heating mantle regulated heating power by observing the temperature of distillate gave the closest result to the theoretical prediction. From the above results, it is concluded that the experiment using branched test-tube with water bath heating is not adequate for the fractional distillation and an alternative experiment using insulated branched round flask with heating mantle regulated heating power during experiment is recommended.

  • PDF

Degummed crude canola oil, sire breed and gender effects on intramuscular long-chain omega-3 fatty acid properties of raw and cooked lamb meat

  • Flakemore, Aaron Ross;Malau-Aduli, Bunmi Sherifat;Nichols, Peter David;Malau-Aduli, Aduli Enoch Othniel
    • Journal of Animal Science and Technology
    • /
    • v.59 no.8
    • /
    • pp.17.1-17.13
    • /
    • 2017
  • Background: Omega-3 long-chain (${\geq}C_{20}$) polyunsaturated fatty acids (${\omega}3$ LC-PUFA) confer important attributes to health-conscious meat consumers due to the significant role they play in brain development, prevention of coronary heart disease, obesity and hypertension. In this study, the ${\omega}3$ LC-PUFA content of raw and cooked Longissimus thoracis et lumborum (LTL) muscle from genetically divergent Australian prime lambs supplemented with dietary degummed crude canola oil (DCCO) was evaluated. Methods: Samples of LTL muscle were sourced from 24 first cross ewe and wether lambs sired by Dorset, White Suffolk and Merino rams joined to Merino dams that were assigned to supplemental regimes of degummed crude canola oil (DCCO): a control diet at 0 mL/kg DM of DCCO (DCCOC); 25 mL/kg DM of DCCO (DCCOM) and 50 mL/kg DCCO (DCCOH). Lambs were individually housed and offered 1 kg/day/head for 42 days before being slaughtered. Samples for cooked analysis were prepared to a core temperature of $70^{\circ}C$ using conductive dry-heat. Results: Within raw meats: DCCOH supplemented lambs had significantly (P < 0.05) higher concentrations of eicosapentaenoic (EPA, $20:5{\omega}3$) and EPA + docosahexaenoic (DHA, $22:6{\omega}3$) acids than those supplemented with DCCOM or DCCOC; Dorset sired lambs contained significantly (P < 0.05) more EPA and EPA + DHA than other sire breeds; diet and sire breed interactions were significant (P < 0.05) in affecting EPA and EPA + DHA concentrations. In cooked meat, ${\omega}3$ LC-PUFA concentrations in DCCOM (32 mg/100 g), DCCOH (38 mg/100 g), Dorset (36 mg/100 g), White Suffolk (32 mg/100 g), ewes (32 mg/100 g) and wethers (33 mg/100 g), all exceeded the minimum content of 30 mg/100 g of edible cooked portion of EPA + DHA for Australian defined 'source' level ${\omega}3$ LC-PUFA classification. Conclusion: These results present that combinations of dietary degummed crude canola oil, sheep genetics and culinary preparation method can be used as effective management tools to deliver nutritionally improved ${\omega}3$ LC-PUFA lamb to meat consumers.

Surgical Repair of Single Ventricle (Type III C solitus) (단심실 -III C Solitus 형의 수술치험-)

  • naf
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.281-288
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF

Surgical Repair for Ebstein's Anomaly (Ebstein 기형의 수술 -2례 보고-)

  • naf
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.289-296
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF

A Study on the Test and Installation Standards of the Video Fire Detector (영상화재감지기 시험과 설치기준에 관한 연구)

  • Lee, Jeong-Hyun;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.1-5
    • /
    • 2016
  • This research performed tests of Video Fire Detector and criteria of installation to make suggestions regarding the criteria that must be reflected in NFSC 203 by comparing the standards of FM Approvals, UL, ISO7240 and NFPA 72. FM Standard related to Video Fire Detector test has been classified as Smoke, Flame type, but the UL Standard has classified only as a Smoke type. This research examined 6 cases of fire phenomenon detection case in ISO 7240 and 3 cases in NFPA 72, respectively. There are 15 items required for the installation standard of a Video Fire Detector and each field standard is presented as a per installation method. To apply a Video Fire Detector, the pertinent items (the definition of term, detector's classification, structure and function among its test item) must be inserted. In addition, 7 items of the fire test, i.e., the sensitivity adjustment, prevent false alarm, ambient temperature test, the effective sensitivity and detection distance and viewing angle, aging test, flood test, must be applied to the actual test. For installation in the field, the operation environment and levels of illumination, and NFSC 203 must be set, and standards relevant to the sound system, indicators' installation distance, etc. need to be inserted.