• Title/Summary/Keyword: Temperature calibration

Search Result 516, Processing Time 0.022 seconds

Multidimensional Hydrodynamic and Water Temperature Modeling of Han River System (한강 수계에서의 다차원 시변화 수리.수온 모델 연구)

  • Kim, Eun-Jung;Park, Seok-Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.866-881
    • /
    • 2012
  • Han River is a complex water system consisting of many lakes. The water quality of Lake Paldang is significantly affected by incoming flows, which are the South and North branches of the Han River, and the Kyungan Stream. In order to manage the water quality of the Lake Paldang, we should consider the entire water body where the incoming flows are included. The objectives of this study are to develop an integrated river and lake modeling system for Han River system using a multidimensional dynamic model and evaluate the model's performance against field measurement data. The integrated model was calibrated and verified using field measurement data obtained in 2007 and 2008. The model showed satisfactory performance in predicting temporal variations of water level, flow rate and temperature. The Root Mean Square Error (RMSE) for water temperature simulation were $0.88{\sim}2.13^{\circ}C$ (calibration period) and $1.05{\sim}2.00^{\circ}C$ (verification period) respectively. And Nash-Sutcliffe Efficiency (NSE) for water temperature simulation were 1089~0.98 (calibration period) and 0.90~0.98 (verification period). Utilizing the validated model, we analyzed the spatial and temporal distributions of temperature within Han River system. The variations of temperature along the river reaches and vertical thermal profiles for each lakes were effectively simulated with developed model. The suggested modeling system can be effectively used for integrated water quality management of water system consisting of many rivers and lakes.

A Temperature Compensating System for LPG Dispenser (LPG 충전기용 온도 보정 시스템 개발)

  • Lee, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3162-3164
    • /
    • 1999
  • In this paper, a temperature compensating system(TCS) for LPG dispenser has been developed. A TCS includes a processor(80C196) with an AID converter. I/O port(82C55) and 6-digit vacuum fluorescent display. Based on encoding signals from the gas flow meter, different calibration values from each apparatus and temperature compensating values from the temperature sensor, the TCS controls the LPG dispensing quantity with switching on or off the solenoid valves. The temperature compensation is performed with analog-to-digital conversion of the temperature sensor. The resolution of temperature compensation is nearly $0.5^{\circ}C$ using 10-bit ADC. The field test of the TCS shows the exact temperature compensation.

  • PDF

An Online Calibration Algorithm for Cellular CDMA Antenna Arrays (Cellular CDMA용 배열 안테나 오차 보정 알고리듬)

  • 석미경;조상우;전주환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2C
    • /
    • pp.306-314
    • /
    • 2004
  • Some receiver(and most transmit) beamforming algorithms with an array antenna at a cellular CDMA base stations require accurate internal and external calibrations. The external calibration, which usually needs to be done only once, determines the array manifolds, i.e. the complex response of each antenna as a function of DOA(Directions of Arrival). The internal calibrations are necessary because characteristics of RF/IF circuity of each receiver chain vary differently in response to temperature or humidity changes. We propose an iterative subspace-based calibration algorithm for an asynchronous CDMA-based antenna away in the presence of unknown gain and phase error is presented. We verify the subspace-based calibration algorithms by performing the experiment using measured data. Also, we propose an efficient algorithm using the simulated annealing technique. This algorithm overcomes the problem of the initial guessing in the subspace-based approach.

Water Content Calibration of Time-Domain Reflectometry Probe Using Laboratory Model Test (실내모형실험을 통한 TDR 함수량계의 현장 함수비 보정)

  • Shin, Eun Chul;Ryu, Byung Hyun;Park, Jeong Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.2
    • /
    • pp.1-11
    • /
    • 2013
  • Water content of subgrade soil in water supply systems has a large effect on performance. Many researchers lately make use of time-domain reflectometry (TDR) probes to measure the soil water content of subgrade soil from monitoring. The laboratory calibration test of TDR probe should be performed with soil field, because TDR probe can cause an error by type, gradation, density, and temperature of soil. This study shows the laboratory calibration test using TDR CS616, TDR-P3, TDR-T3. The calibration equations of TDR were then proposed. It was confirmed from the study that the data of TDR probe monitored in field could be used to estimate the freezing, unfrozen water content, and matric suction of soil.

Subcutaneous Temperature Estimation By Microwave Radiometry (Microwave Radiometry 원리를 이용한 생체 내부 온도 추정)

  • Kim, Kyeong-Seop;Lee, Jeong-Whan
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.357-364
    • /
    • 2006
  • Microwave Radiometry is the spectral measurement of eleclromagnetic radiation at frequency bands in the microwave region. One particular application of Microwave Radiometry is for analyzing temperature difffrentials of inside of human body to detect and diagnose pathologic conditions in which the temperature differentials are related with the symptoms of certain diseases. To accomplish this aim, we propose a new calibration method for estimating subcutaneous temperature by Microwave Radiometer and we also suggest a tumor-imitator phantom structure for simulating heat diffusion propagated by tissues around tumors to evaluate the discernment of brighuless temperature difffrentials.

An Experimental Study on Temperature and Velocity Fields of the Turbulent Flows Horizontal Cylindrical Tube by Using Thermo-sensitive Liquid Crystal (수평원통 관에서 감온액정을 이용한 난류유동의 온도 및 속도장에 관한 실험적 연구)

  • 장태현;도덕희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.921-929
    • /
    • 2003
  • An experimental investigation was performed to study the characteristics of turbulent water flow in a horizontal circular tube by using liquid crystal. To determine some characteristics of the turbulent flow, 2D PIV technique is employed for velocity measurement and liquid crystal is used for heat transfer experiments in water. Temperature visualization was made quantitatively by calibrating the color of the liquid crystal versus temperature using various approaches (TLC technique: Thermochromic Liquid Crystal), and a neural-network algorithm was applied to the color-to-temperature calibration. This study shoud the temperature and time-mean velocity distribution for Re = 2,436, 2,500 and 2,724 along longitudinal sections and the results appear to be physically reasonable.

Simultaneous Temperature and Velocity Fields Measurements near the Boiling Point

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Koo, Bon-Young;Kim, Seok-Ro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.531-542
    • /
    • 2007
  • Simultaneous measurement technique for temperature and velocity fields near a heated solid body has been constructed. The measurement system consists of a 3-late CCD color camera, a color image grabber, a 1ighting system, a host computer and a software for the whole quantification process. Thermo Chromic Liquid Crystals (TCLC) was used as temperature sensors. A neural network was used to get a calibration curve between the temperature and the color change of the TCLC in order to enhance the dynamic range of temperature measurement. The velocity field measurement was attained by the use of the fray-level images taken for the flow field, and by introducing the cross-correlation technique. The temperature and the velocity fields of the forced and the natural convective flows neat the surface of a cartridge heater were measured simultaneously with the constructed measurement system.

Temperature field measurement of convective flow in a Hele-Shaw Cell with TLC and color image processing (TLC와 컬러화상처리를 이용한 Hele-Shaw Cell 내부 대류 온도장 측정)

  • Yun, Jeong-Hwan;Do, Deok-Hui;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.3
    • /
    • pp.1114-1122
    • /
    • 1996
  • Variation of temperature field in a Hele-Shaw convection cell was measured by using a HSI true color image processing system and TLC(Thermochromic Liquid Crystal) solution. The relationship between the hue value of TLC color image and real temperature was obtained and this calibration result was used to measure the true temperature. The temperature field in the Hele-Shaw convection cell shows periodic characteristics of 45 sec at Ra = 9.3 * 10$\^$6/. The temperature field measurement technique developed in this study was proved to be a useful and powerful tool for analyzing the unsteady thermal fluid flows.

A Smart Sensor System with a Programmable Temperature Compensation Technique (프로그래머블한 온도 보상 기법의 스마트 센서 시스템)

  • Kim, Ju-Hwan;Kang, Yu-Ri;Lee, Woo-Kwan;Kim, Soo-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.11
    • /
    • pp.63-70
    • /
    • 2008
  • In this paper, a smart sensor system for the MEMS pressure sensor was developed. A compensation algorithm and programmable calibration circuits were presented to eliminate errors caused by temperature drift of piezoresistive pressure sensors in itself. This system consisted of signal conditioning, calibration, temperature detection, microprocessor, and communication parts and these were integrated into a SOC. A RS-232 interface was employed for monitoring and control of a smart sensor system. The area of fabricated IC is $4.38{\times}3.78\;mm^2$ and a $0.35{\mu}m$ high voltage CMOS process was used. Compensation error for temperature drift of 50 KPa pressure sensors was measured into ${\pm}0.48%$ in the range of $-40^{\circ}C{\sim}150^{\circ}C$. Total power consumption was 30.5 mW.

Automatic Determination of the Energy Pulse-height Relationship in NaI(TI) Spectra (NaI(T1) 검출기 스펙트럼의 에너지-채널 관계 자동결정)

  • Lee, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.143-151
    • /
    • 1997
  • As the pulse heights from a NaI(Tl) detector vary with the temperature of the measuring environment a significant change in temperature may affect the energy calibration of the spectrometer. The auto-adjustment of the channel corresponding to a pulse heights can be achieved by introducing an external reference source to compensate the temperature dependency of pulse heights, but unfavorable increases of the Compton continuum are caused due to the external source. In this study, the total absorption peaks dominant in the typical environmental gamma spectrum-239 keV from $^{212}Pb$, 351 keV from $^{214}Pb$, 1460 keV from $^{40}K$ and 2614 keV from $^{208}Tl$ for examples - were used as reference in the correction of energy calibration. With these peaks, the program to calibrate the energy of the s spectrum was developed using Microsoft Visual Basic language. The program developed here was applied to the environmental spectra measured at intervals of 30 minutes in the temperature range of from $-20^{\circ}C$ to $10^{\circ}C$ to demonstrate the validity and applicability. As a result of the test, the correction scheme appeared to be effective in the temperature changes encountered in the usual environment.

  • PDF