• 제목/요약/키워드: Temperature Deviation

검색결과 850건 처리시간 0.029초

직렬저항/퍼지로직 기반 배터리 선별 그룹 내 정량적 우선순위 비교 및 선정 (Comparison and Selection of Quantitative Priority in Battery Screening Group Based on Series Resistance/Fuzzy Logic)

  • 조상우;한동호;최창기;김재원;김종훈
    • 전력전자학회논문지
    • /
    • 제27권2호
    • /
    • pp.142-149
    • /
    • 2022
  • In increasing the safety and usage of lithium-ion battery packs, reducing the parameter deviation between cells, such as voltage and temperature within the battery pack, is important. In this study, we propose a screening method to reduce parameter deviation between cells in battery packs. Screening algorithms are constructed based on Fuzzy logic and quantitatively express the similarities between battery cells. Screening is applied by utilizing series resistance components after experiments of electrical characteristics that consider the operation status of battery packs. After screening, the standard deviation of series resistance components according to the similarity ranking is compared and analyzed, and their conformity are verified with the algorithm parameters.

목본식물 형성층 전기저항에 영향을 주는 환경 요인 (Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants)

  • 김동욱;김민수;이부용
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

소결분위기 변환온도가 Al2O3/Cu 나노복합재료의 미세조직과 파괴강도에 미치는 영향 (Effect of Sintering Atmosphere Changing Temperature on Microstructure and Mechanical Property of Al2O3/Cu Nanocomposites)

  • 오승탁;윤세중
    • 한국분말재료학회지
    • /
    • 제11권5호
    • /
    • pp.421-426
    • /
    • 2004
  • The microstructure and mechanical property of hot-pressed $Al_2O_3/Cu$ composites with a different temperature for atmosphere changing from H$_{2}$ to Ar have been studied. When atmosphere-changed from H$_{2}$ to Ar gas at 145$0^{\circ}C$, the hot-pressed composite was characterized by inhomogeneous microstructure and low fracture strength. On the contrary, when atmosphere-changed at low temperature of 110$0^{\circ}C$ the composite showed more homogeneous microstructure, higher fracture strength and smaller deviation in strength. Based on the thermodynamic consideration and microstructural analysis, it was interpreted that the Cu wetting behavior relating to the formation of CuAlO$_{2}$ is probably responsible for strong dependence of microstructure on atmosphere changing temperature. The reason for a strong sensitivity of fracture strength and especially of its deviation to atmosphere changing temperature was explained by the microstructural inhomogeneity and by the role of CuAlO$_{2}$ phase on the interfacial bonding strength.

Solar Simulator의 시험조건에 따른 태양전지모듈의 전기적 특성 분석 (Electrical Properties of Photovoltaic Modules with test condition of Solar Simulator)

  • 강기환;박지홍;유권종;박이준;안형근;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1775-1777
    • /
    • 2005
  • In this paper, maximum output of three different temperature conditions of the photovoltaic modules have been tested and compared to obtain the optimum conditions for the maximum power operation. Temperatures of the cell and module have been set to $20^{\circ}C$, $25^{\circ}C$ and $30^{circ}C$ under the constant light intensity of 1kW/$m^2$. 125${\times}$125mm 36 single crystal solar cells having 80 [W] each have been serially connected in the module. From the results, maximum output deviation of 4.67% has been obtained under the ceil temperature of $20^{\circ}C$ and module temperature of $30^{\circ}C$ while minimum deviation of 0.41${\sim}$0.92% has been measured under the same temperatures of cell and module. Therefore it has been found that the temperature of both cell and module should be fixed to $25^{\circ}C$ to obtain stable data unless the temperature coefficient should be compensated for the testing sample.

  • PDF

Development and verification of PWR core transient coupling calculation software

  • Li, Zhigang;An, Ping;Zhao, Wenbo;Liu, Wei;He, Tao;Lu, Wei;Li, Qing
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3653-3664
    • /
    • 2021
  • In PWR three-dimensional transient coupling calculation software CORCA-K, the nodal Green's function method and diagonal implicit Runge Kutta method are used to solve the spatiotemporal neutron dynamic diffusion equation, and the single-phase closed channel model and one-dimensional cylindrical heat conduction transient model are used to calculate the coolant temperature and fuel temperature. The LMW, NEACRP and PWR MOX/UO2 benchmarks and FangJiaShan (FJS) nuclear power plant (NPP) transient control rod move cases are used to verify the CORCA-K. The effects of burnup, fuel effective temperature and ejection rate on the control rod ejection process of PWR are analyzed. The conclusions are as follows: (1) core relative power and fuel Doppler temperature are in good agreement with the results of benchmark and ADPRES, and the deviation between with the reference results is within 3.0% in LMW and NEACRP benchmarks; 2) the variation trend of FJS NPP core transient parameters is consistent with the results of SMART and ADPRES. And the core relative power is in better agreement with the SMART when weighting coefficient is 0.7. Compared with SMART, the maximum deviation is -5.08% in the rod ejection condition and while -5.09% in the control rod complex movement condition.

A Time Dependent Analysis of Thermal Environment in Beehouse

  • Lee, Suk-Gun;Li, Zhenhai;Choi, Kwang-Soo
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 1997년도 가을 심포지움 및 학술논문발표요지
    • /
    • pp.20-26
    • /
    • 1997
  • The design or analysis of beehouse inside temperature environment based on steady heat transfer theory causes much deviation and theoretically it is impossible to control the inside temperature lower than the outside temperature under the condition that the bee produces heat and no cooling equipment is installed. But in practical use of beehouse, the inside temperature is somehow lower than the outside temperature because of the heat inertia of concrete floor. (omitted)

  • PDF

Comparison between Gel Pad Cooling Device and Water Blanket during Target Temperature Management in Cardiac Arrest Patients

  • Jung, Yoon Sun;Kim, Kyung Su;Suh, Gil Joon;Cho, Jun-Hwi
    • Acute and Critical Care
    • /
    • 제33권4호
    • /
    • pp.246-251
    • /
    • 2018
  • Background: Target temperature management (TTM) improves neurological outcomes for comatose survivors of out-of-hospital cardiac arrest. We compared the efficacy and safety of a gel pad cooling device (GP) and a water blanket (WB) during TTM. Methods: We performed a retrospective analysis in a single hospital, wherein we measured the time to target temperature ($<34^{\circ}C$) after initiation of cooling to evaluate the effectiveness of the cooling method. The temperature farthest from $33^{\circ}C$ was selected every hour during maintenance. Generalized estimation equation analysis was used to compare the absolute temperature differences from $33^{\circ}C$ during the maintenance period. If the selected temperature was not between $32^{\circ}C$ and $34^{\circ}C$, the hour was considered a deviation from the target. We compared the deviation rates during hypothermia maintenance to evaluate the safety of the different methods. Results: A GP was used for 23 patients among of 53 patients, and a WB was used for the remaining. There was no difference in baseline temperature at the start of cooling between the two patient groups (GP, $35.7^{\circ}C$ vs. WB, $35.6^{\circ}C$; P=0.741). The time to target temperature (134.2 minutes vs. 233.4 minutes, P=0.056) was shorter in the GP patient group. Deviation from maintenance temperature (2.0% vs. 23.7%, P<0.001) occurred significantly more frequently in the WB group. The mean absolute temperature difference from $33^{\circ}C$ during the maintenance period was $0.19^{\circ}C$ (95% confidence interval [CI], $0.17^{\circ}C$ to $0.21^{\circ}C$) in the GP group and $0.76^{\circ}C$ (95% CI, $0.71^{\circ}C$ to $0.80^{\circ}C$) in the WB group. GP significantly decreased this difference by $0.59^{\circ}C$ (95% CI, $0.44^{\circ}C$ to $0.75^{\circ}C$; P<0.001). Conclusions: The GP was superior to the WB for strict temperature control during TTM.

수도권 지역에서의 고해상도 지형과 지면피복자료에 따른 수치모의 민감도 실험 (Sensitivity Test of the Numerical Simulation with High Resolution Topography and Landuse over Seoul Metropolitan and Surrounding Areas)

  • 박성화;지준범;이채연
    • 대기
    • /
    • 제25권2호
    • /
    • pp.309-322
    • /
    • 2015
  • The objective of this study is to evaluate the impact of the high resolution topographies and landuses data on simulated meteorological variables (wind speed at 10 m, temperature at 2 m and relative humidity at 2 m) in WRF. We compare the results with WRF simulation using each resolution of the topographies and landuses, and with 37 AWS observation data on the Seoul metropolitan regions. According to results of using high-resolution topography, WRF model gives better topographical expression over domain. And we can separate more detail (Low intensity residential, high intensity residential, industrial or commercial) using high resolution landuses data. The result shows that simulated temperature and wind speed are generally higher than AWS observation data. However, simulation trend with temperature, wind speed, and relative humidity are similar to observation data. The reason for that is that the high precipitation event occurred in CASE 1 and 2. Temperature have correlation of 0.43~0.47 and standard deviation of $2.12{\sim}2.28^{\circ}C$ in CASE 1, while correlation of more than 0.8 and standard deviation of $3.05{\sim}3.18m\;s^{-1}$ in CASE 2. In case of wind speed, correlation have lower than 0.5 and Standard Deviation of $1.88{\sim}2.34m\;s^{-1}$ in CASE 1 and 2. In statistical analysis shows that using highest resolution (U01) results are more close to the AWS observation data. It can be concluded that the topographies and landuses are important factor that affect model simulation. However, the tendency to always use high resolution topographies and landuses data appears to be unjustified, and optimal solution depends on the combination of scale effect and mechanisms of dynamic models.

The Annual Averaged Atmospheric Dispersion Factor and Deposition Factor According to Methods of Atmospheric Stability Classification

  • Jeong, Hae Sun;Jeong, Hyo Joon;Kim, Eun Han;Han, Moon Hee;Hwang, Won Tae
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.260-267
    • /
    • 2016
  • Background: This study analyzes the differences in the annual averaged atmospheric dispersion factor and ground deposition factor produced using two classification methods of atmospheric stability, which are based on a vertical temperature difference and the standard deviation of horizontal wind direction fluctuation. Materials and Methods: Daedeok and Wolsong nuclear sites were chosen for an assessment, and the meteorological data at 10 m were applied to the evaluation of atmospheric stability. The XOQDOQ software program was used to calculate atmospheric dispersion factors and ground deposition factors. The calculated distances were chosen at 400 m, 800 m, 1,200 m, 1,600 m, 2,400 m, and 3,200 m away from the radioactive material release points. Results and Discussion: All of the atmospheric dispersion factors generated using the atmospheric stability based on the vertical temperature difference were shown to be higher than those from the standard deviation of horizontal wind direction fluctuation. On the other hand, the ground deposition factors were shown to be same regardless of the classification method, as they were based on the graph obtained from empirical data presented in the Nuclear Regulatory Commission's Regulatory Guide 1.111, which is unrelated to the atmospheric stability for the ground level release. Conclusion: These results are based on the meteorological data collected over the course of one year at the specified sites; however, the classification method of atmospheric stability using the vertical temperature difference is expected to be more conservative.

Numerical and Experimental Investigation of the Heating Process of Glass Thermal Slumping

  • Zhao, Dachun;Liu, Peng;He, Lingping;Chen, Bo
    • Journal of the Optical Society of Korea
    • /
    • 제20권2호
    • /
    • pp.314-320
    • /
    • 2016
  • The glass thermal forming process provides a high volume, low cost approach to producing aspherical reflectors for x-ray optics. Thin glass sheets are shaped into mirror segments by replicating the mold shape at high temperature. Heating parameters in the glass thermal slumping process are crucial to improve surface quality of the formed glass. In this research, the heating process of a thermal slumping glass sheet on a concave parabolic mold was simulated with the finite-element method (FEM) to investigate the effects of heating rate and soaking temperature. Based on the optimized heating conditions, glass samples 0.5 mm thick were formed in a furnace with a steel concave parabolic mold. The figure errors of the formed glass were measured and discussed in detail. It was found that the formed glass was not fully slumped at the edges, and should be trimmed to achieve better surface deviation. The root-mean-square (RMS) deviation and peak-valley (PV) deviation between formed glass and mold along the axial direction were 2.3 μm and 4.7 μm respectively.