• Title/Summary/Keyword: Temperature Accuracy

Search Result 1,772, Processing Time 0.035 seconds

Effect of Cooking Methods on S-Allyl-L-Cysteine Content of Garlic (마늘의 조리방법에 따른 S-Allyl-L-Cysteine 함량 변화)

  • Lee, Sang Hoon;Jeong, Yun Sook;Hwang, Kyung-A;Song, Jin;Noh, Geon Min;Hwang, In Guk
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.8
    • /
    • pp.1221-1226
    • /
    • 2016
  • This study investigated changes in the S-allyl-L-cysteine (SAC) content of garlic using different cooking methods. Methods for determining SAC were validated by determining specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy using an high-performance liquid chromatography-fluorescence detection system. Results showed high linearity in the calibration curve with a coefficient of correlation ($R^2$) of 0.9999. The LOD and LOQ values for SAC were 0.15 and $0.47{\mu}g/mL$, respectively. The relative standard deviations for intra- and inter-day precision of SAC were less than 5%. The recovery rate of SAC was in the range from 97.35% to 97.47%. The SAC content of raw garlic was 2.77 mg/g, and there was no significant difference in SAC content according to blanching and microwave treatment. However, SAC content upon boiling and autoclaving at $110^{\circ}C$ and $121^{\circ}C$ increased from 3.50~9.16 mg/g, 6.52~16.21 mg/g, and 14.15~50.24 mg/g with increasing cooking temperature and time, respectively.

A Computational Mineralogy Study of the Crystal Structure and Stability of Aluminum Silicate (Al2SiO5) Minerals (알루미늄 규산염(Al2SiO5) 광물의 결정구조와 안정성에 대한 계산광물학 연구)

  • Kim, Juhyeok;Son, Sangbo;Kwon, Kideok D.
    • Journal of the Mineralogical Society of Korea
    • /
    • v.31 no.1
    • /
    • pp.13-22
    • /
    • 2018
  • Aluminum silicates ($Al_2SiO_5$) undergo phase transitions among kyanite, andalusite, and sillimanite depending on temperature and pressure conditions. The minerals are often used as an important indicator of the degree of metamorphism for certain metamorphic rocks. In this study, we have applied classical molecular dynamics (MD) simulations and density functional theory (DFT) to the aluminum silicates. We examined the crystal structures as a function of applied pressure and the corresponding stabilities based on calculated enthalpies at each pressure. In terms of the lattice parameters, both methods showed that the volume decreases as the pressure increases as observed in the experiment. In particular, DFT results differed from experimental results by much less than 1%. As to the relative stability, however, both methods showed different levels of accuracy. In the MD simulations, a transition pressure at which the relative stability between two minerals reverse could not be determined because the enthalpies were insensitive to the applied pressure. On the other hand, in DFT calculations, the relative stability relation among the three minerals was consistent with experiment, although the transition pressure was strongly dependent on the choice of the electronic exchange-correlation functional.

Development and Validation of HPLC Method for Pharmacokinetic Study of Promethazine in Human (염산프로메타진 체내동태 연구를 위한 혈청 중 프로메타진의 HPLC 정량법 개발 및 검증)

  • Cho, Hae-Young;Kang, Hyun-Ah;Lee, Hwa-Jeong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.1
    • /
    • pp.23-29
    • /
    • 2006
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of promethazine in human serum was developed, validated, and applied to the pharmacokinetic study of promethazine. Promethazine and internal standard, chlorpromazine, were extracted from human serum by liquid-liquid extraction with n-hexane containing 0.8% isopropanol and analyzed on a Capcell Pak CN column with the mobile phase of acetonitrile-0.2 M potassium dihydrogen phosphate (42:58, v/v, adjusted to pH 6.0 with 1 M NaOH). Detection wavelength of 251 nm and flow rate of 0.9 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed promethazine concentration (10 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 1-40 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 1 mL of serum was 1 ng/mL, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 96.15 to 105.40% for promethazine with overall precision (% C.V.) being 6.70-11.22%. The relative mean recovery of promethazine for human serum was 63.54%. Stability (freeze-thaw and short-term) studies showed that promethazine was stable during storage, or during the assay procedure in human serum. However, the storage at $-80^{\circ}C$ for 4 weeks showed that promethazine was not stable. Extracted serum sample and stock solution were not allowed to stand at ambient temperature for 12 hr prior to injection. The peak area and retention time of promethazine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of promethazine in human serum samples for the pharmacokinetic studies of orally administered Himazin tablet (25 mg as promethazine hydrochloride) at three different laboratories, demonstrating the suitability of the method.

A Study on Evaluation of LED Lighting Environments for Energy Saving and Work Effectiveness (에너지 저감과 업무 효율성을 위한 LED 조명환경 평가에 대한 연구)

  • Kim, Hyung-Sun;Lim, Jae-Hyun;Lee, Kee-Sun;Kim, Kil-Hee;Jung, Hee-Chang;Kim, Jin Ho
    • Science of Emotion and Sensibility
    • /
    • v.18 no.2
    • /
    • pp.45-54
    • /
    • 2015
  • This study carried out an experiment to identify subject's work effectiveness and energy saving effect using LED light. Towards this end, this study configured nine various lighting environments in order to control PWM (Pulse Width Modulation) and illuminance (lux), which are the characteristics of LED light. The PWM ratio of LED light was set as R:G:B=1:1:1, R:G:B=4:1:5, and R:G:B=8:7:7, respectively, and illuminance (lux) was set as 400 lx, 700 lx, and 1000 lx, respectively. In addition, the indoor environment was set temperature $20-24^{\circ}C$, humidity 50%-60%, and the amount of clothing 1. This study analyzed work effectiveness and energy consumption in nine lighting environments, each. Error correction was performed for work effectiveness analysis, and cumulative power consumption was measured in each lighting environment for energy consumption analysis. According to experiment results through the lighting environments suggested in this study, accuracy and spent time effectiveness were good in 700lux and higher than 400lux. For spent time, the best effectiveness was revealed in the suggested PWM ratio, R:G:B=8:7:7. The lowest power consumption on each illuminance (lux) was revealed in the order of R:G:B=8:7:7, RGB=1:1:1, and R:G:B=4:1:5. Therefore, pulse-width modulation effect is proposed in this paper was found to affect the efficiency and energy saving.

A Study on High Speed Laser Welding by using Scanner and Industrial Robot (스캐너와 산업용 로봇을 이용한 고속 레이저 용접에 관한 연구)

  • Kang, Hee-Shin;Suh, Jeong;Kim, Jong-Su;Kim, Jeng-O;Cho, Taik-Dong
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.29-29
    • /
    • 2009
  • On this research, laser welding technology for manufacturing automobile body is studied. Laser welding technology is one of the important technologies used in the manufacturing of lighter, safer automotive bodies at a high level of productivity; the leading automotive manufacturers have replaced spot welding with laser welding in the process of car body assembly. Korean auto manufacturers are developing and applying the laser welding technology using a high output power Nd:YAG laser and a 6-axes industrial robot. On the other hand, the robot-based remote laser welding system was equipped with a long focal laser scanner system in robotic end effect. Laser system, robot system, and scanner system are used for realizing the high speed laser welding system. The remote laser welding system and industrial robotic system are used to consist of robot-based remote laser welding system. The robot-based remote laser welding system is flexible and able to improve laser welding speed compared with traditional welding as spot welding and laser welding. The robot-based remote laser systems used in this study were Trumpf's 4kW Nd:YAG laser (HL4006D) and IPG's 1.6kW Fiber laser (YLR-1600), while the robot systems were of ABB's IRB6400R (payload:120kg) and Hyundai Heavy Industry's HX130-02 (payload:130kg). In addition, a study of quality evaluation and monitoring technology for the remote laser welding was conducted. The welding joints of steel plate and steel plate coated with zinc were butt and lapped joints. The quality testing of the laser welding was conducted by observing the shape of the beads on the plate and the cross-section of the welded parts, analyzing the results of mechanical tension test, and monitoring the plasma intensity and temperature by using UV and IR detectors. Over the past years, Trumf's 4kW Nd:YAG laser and ABB's IRB6400R robot system was used. Nowadays, the new laser source, robot and laser scanner system are used to increase the processing speed and to improve the efficiency of processes. This paper proposes the robot-based remote laser welding system as a means of resolving the limited welding speed and accuracy of conventional laser welding systems.

  • PDF

Chemical Preservation Methods of Urine Sediment for Quality Control (정도관리를 위한 요침사의 화학적 보존방법)

  • Cho, Soung Suck;Kim, Myong Soo;Shin, Kyung-A
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.359-365
    • /
    • 2017
  • There is greater standardization of quality control for microscopic examination of urine than for physicochemical test. In this study, we investigated whether it is possible to control the sediment accuracy by microscopic examination through the real thing by preserving the essential sediment with glutaraldehyde, which is required for the rationality of sediment quality control. A urine specimen was prepared using 2.5% glutaraldehyde as a preservation solution. Samples treated with urine preservatives confirmed the morphological deformation of the cells for four weeks at intervals of one week and confirmed whether they should be preserved for 4 weeks thereafter. After preparing the required sediment slide, two more slides were produced; one was stored in a refrigerator for, and the other was stored at room temperature. The morphological deformation of the specimen was confirmed. Glutaraldehyde has the effect of preserving the refrigerated essential sediments and storing them for up to 8 weeks, refrigerated storage after slide production, stabilized by 3 days. Moreover, after treatment with preservatives, the production of the slide and comparison between the measured values between the laboratories and examiners showed a low consistency. In conclusion, we showed that the urine sediment components can be preserved, and it can be used for quality control and education through real objects.

Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room (반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가)

  • Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.21-28
    • /
    • 2012
  • The objective of this study is to evaluate the prediction accuracy of FDS(Fire Dynamic Simulator) for the thermal and chemical characteristics of under-ventilated fire with unsteady fire growth in a semi-closed compartment. To this end, a standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time (until maximum 2.0 MW based on ideal heat release rate) using a spray nozzle located at the center of enclosure. To verify the capability of FDS, the predicted results were compared with a previous experimental data under the identical fire conditions. It was observed that with an appropriate grid system, the numerically predicted temperature and heat flux inside the compartment showed reasonable agreement with the experimental data. On the other hand, there were considerable limitations to predict accurately the unsteady behaviors of CO and $CO_2$ concentration under the condition of continuous fire growth. These results leaded to a discrepancy between the present evaluation of FDS and the previous evaluation conducted for steady-state under-ventilated fires. It was important to note that the prediction of transient CO production characteristics using FDS was approached carefully for the under-ventilated fire in a semi-closed compartment.

Establishment of Analytical Method for Propylene Glycol Alginate in Food Products by Size-exclusion Chromatography (Size-exclusion chromatography법에 의한 식품 중 알긴산프로필렌글리콜 분석법 확립)

  • Jeong, Eun-Jeong;Choi, Yoo-Jeong;Lee, Gunyoung;Yun, Sang Soon;Lim, Ho Soo;Kim, Yong-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.404-410
    • /
    • 2017
  • An analytical method for determination of propylene glycol alginate (PGA) in food products was developed by HPLC-size-exclusion chromatography. The GF-7M HQ column and LT-ELSD detector were determined by considering the instrumental analysis conditions for PGA analysis. The pretreatment method for the analysis of PGA was suitable for 3 hr extraction at $20^{\circ}C$ and 150 rpm according to the extraction temperature. Linearity ($R^2$) for the analysis of PGA was 0.9873 at calibration curve range of 300, 500, 700, 1,000, and 1,500 mg/kg (5 points). The limit of detection and limit of quantification of PGA on HPLC system was 171.43 and 519.50 mg/kg, respectively. The accuracy and coefficient of variation obtained by size-exclusion chromatography were 86.1~110.4% and 4.1~13.5%, respectively. By applying the HPLC-size-exclusion chromatography system, it was possible to analyze the contents of PGA in 134 different types of food products.

An Accuracy Estimation of AEP Based on Geographic Characteristics and Atmospheric Variations in Northern East Region of Jeju Island (제주 북동부 지역의 지형과 대기변수에 따른 AEP계산의 정확성에 대한 연구)

  • Ko, Jung-Woo;Lee, Byung-Gul
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.3
    • /
    • pp.295-303
    • /
    • 2012
  • Clarify wind energy productivity depends on three factors: the wind probability density function(PDF), the turbine's power curve, and the air density. The wind PDF gives the probability that a variable will take on the wind speed value. Wind shear refers to the change in wind speed with height above ground. The wind speed tends to increase with the height above ground. also, Wind PDF refers to the change with height above ground. Wind analysts typically use the Weibull distribution to characterize the breadth of the distribution of wind speeds. The Weibull distribution has the two-parameter: the scale factor c and the shape factor k. We can use a linear least squares algorithm(or Ln-least method) and moment method to fit a Weibull distribution to measured wind speed data which data was located same site and different height. In this study, find that the scale factor is related to the average wind speed than the shape factor. and also different types of terrain are characterized by different the scale factor slop with height above ground. The gross turbine power output (before accounting for losses) was caculated the power curve whose corresponding air density is closest to the air density. and air desity was choose two way. one is the pressure of the International Standard Atmosphere up to an elevation, the other is the measured air pressure and temperature to calculate the air density. and then each power output was compared.

Establishment for analytical method of methanol in wet wipes by headspace gas chromatography (가스크로마토그래프-헤드스페이스를 이용한 물휴지 중 메탄올 정량법 확립 연구)

  • Choi, Yongkyu;Baek, Eunji;Min, Chungsik;Lee, Rheeda;Park, Soonyoung;Ahn, Jaehyung;Kim, Sangseop;Hong, Seonghwa;Kim, Younglim
    • Analytical Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.242-247
    • /
    • 2016
  • This research aims to set up and validate methods of analyzing the methanol in wet wipes and verifies the analysis methods that applied to the wet wipes. We used Headspace (HS) Gas Chromatography (GC) - Flame Ionization Detector (FID) to the establish analysis method of methanol in wet wipes and optimized heating temperature, heating time, GC conditions with column. The result indicated that 3 mL of sample in 20 mL headspace vial can be equilibrated efficiently in headspace sampler at 70 ℃ for 10 min and sample was measured by GC with spli injection mode(10:1). The results show that linearity from 1 to 100 ppm was over R2 0.9995, precision was RSD 1.83 % and accuracy(recovery rate) was 105.44 (±1.05 %) on water matrix and wet wipes matrix removed non-woven fabric. Also, monitoring results of total 20 cosmetics on the market, from 0.00017 to 0.00156 % of methanol was detected from wet wipes.