• Title/Summary/Keyword: Telos Device

Search Result 29, Processing Time 0.029 seconds

A Study of Applied Pressure According to Knee variable During Lachman Test for Anterior Cruciate Ligament using Telos Device (Telos Device를 이용한 전방십자인대 Lachman 검사 시 무릎두께와 활성도에 따른 인가압력에 대한 고찰)

  • Lim, Jong-Cheon;Kim, Sang-Hyuk;Seo, Sang-Hyuk;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.391-398
    • /
    • 2019
  • The purpose of study is to investigate the difference of the daN force applied during the examination using Telos Device and the degree of fluctuation of anterior cruciate ligament according to the individual differences of the muscles involved in knee stability. The examination was done by the Lachman test using Telos Device and the changes of anterior cruciate ligament were measured by varying the force of 0. 15, 30 daN on each right and left side and the force of 30 daN after the bruce protocol. Computed tomography (CT) was used to measure muscle mass. As a result of measuring the degree of fluctuation of the anterior cruciate ligament according to the change of the force applied to the Telos Device, there was a statistically significant difference in the knee fluctuation when 15 daN and 30 daN were applied on both right and left. Also, it is analyzed that the degree of fluctuation of anterior cruciate ligament varies according to the difference of individual's muscle mass. Therefore, it is considered that the force applied to the Telos Device should be changed according to the difference of individual's muscle mass.

A Study on the Standardization of the Test Method Upon Testing the Anterior Cruciate Ligament Damage Using TELOS (TELOS를 이용한 Knee Stress (Lachman)검사의 표준화에 대한 연구)

  • Lim, Jongcheon;Han, Dongkyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.57-63
    • /
    • 2014
  • This study aims to find out the standardized test criteria regarding patients with the anterior cruciate ligament damage by identifying the degree of the flexion gap of femur and tibia upon bending of the anterior cruciate ligament in order to carry out the accurate test of such impairment. On the standardized test method and judgement criteria upon the anterior cruciate ligament test using Telos, it has been shown that there was no significant difference in the results according to the position of a fixed roller in the anterior cruciate ligament test for normal patients. However, in a test for patients who had undergone the anterior cruciate ligament reconstruction, it has been shown that the measured values of the anterior cruciate ligament tended to be pushed when the position of a fixed roller was less than 1cm in the test according to the position of a fixed roller of Telos (less than 1cm, more than 3cm), and this was statistically significant. The anterior cruciate ligament test (knee stress test) is a limited method used in orthopedics and rehabilitation medicine, and there have been no standardized test guidelines available yet although numerous ligament measurement tests have been performed. In addition, since the measured values are often different depending on testers even on the test that is expected to give the same result, the reproducibility of the test is still low. Accordingly, it is considered that the criteria for the anterior cruciate ligament test need to be established, and this would contribute to the accuracy of the diagnosis through the accurate test and standardized measurements.

Reconstruction of Anterior Cruciate Ligament With Bone-Patellar tendon-Bone Allograft (동종 슬개건을 이용한 전방십자인대 재건술)

  • Chun, Churl Hong;Lee, Byoung Chang;Kim, Young Jin;Yang, Hwan Duk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.102-108
    • /
    • 1999
  • Purpose : The purpose of this study was to evaluate the clinical results of bone-patellar tendon-bone(B-PTB) allograft for ACL reconstruction without mechanical tensioning device. Material and Method : Forty-six knees in 43 patients were reviewed and evaluated with subjective evaluation, objective evaluation, Telos stress arthrometer and modified Feagin Scoring System. The average age at the time of operation was 27 years(range, 18-42) and the average follow up period was 41 months(range, 22-79). Authors reconstructed ACL using B-PTB allograft which was prepared by rehydration preoperatively without tensioning by mechanical tensioning device. The tension for allograft was obtained by full flexion and extension intraoperatively. All operation were performed arthroscopically by two-tunnel method to avoid the mismatching of allograft tendon length. Result : The modified Feagin Scoring System revealed 39 cases(84.7%) with excellent or good results and 7 cases(15.3%) with fair or poor results. The mean follow-up Lysholm Knee Score was 84. Telos arthrometer revealed 41 cases had an injured-to-uninjured difference of 5 mm or less(mean 2.3mm). The range of motion of knee was nearly normal and there was no extension lag in any cases at last follow up. Conclusion : Clinical results using B-PTB allograft showed less morbidity than B-PTB autograft. The intraoperative tensioning method by full flexion and extension without mechanical tensioning device was not bad. Therefore, B-PTB allograft is a good substitute material in reconstruction of the ACL.

  • PDF

Design of Real-time Vital-Sign Encryption Module for Wearable Personal Healthcare Device (착용형 개인 건강관리 장치를 위한 실시간 생체신호 암호화 모듈의 설계)

  • Kim, Jungchae;Yoo, Sun Kook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.221-231
    • /
    • 2013
  • Exchanging personal health information(PHI) is an essential process of healthcare services using information and communication technology. But the process have the inherent risk of information disclosure, so the PHI should be protected to ensure the reliability of healthcare services. In this paper, we designed encryption module for wearable personal health devices(PHD). A main goal is to guarantee that the real-time encoded and transmitted PHI cannot be allowed to be read, revised and utilized without user's permission. To achieve this, encryption algorithms as DES and 3DES were implemented in modules operating in Telos Rev B(16bit RISC, 8Mhz). And the experiments were performed in order to evaluate the performance of encryption and decryption using vital-sign measured by PHD. As experimental results, an block encryption was measured the followings: DES required 1.802 ms and 3DES required 6.683 ms. Also, we verified the interoperability among heterogeneous devices by testing that the encrypted data in Telos could be decoded in other machines without errors. In conclusion, the encryption module is the method that a PHD user is given the powerful right to decide for authority of accessing his PHI, so it is expected to contribute the trusted healthcare service distribution.

Comparison of Anterior Cruciate Ligament Reconstructions Using Hamstring Tendon Autograft and Tibialis Tendon Allograft (자가 슬괵건 및 동종 경골건을 이용한 전방 십자 인대 재건술의 결과 비교)

  • Song, Eun-Kyoo;Seon, Jong-Keun;Bae, Bong-Hyun;Park, Sang-Jin;Kim, Jong-Seon;Lee, Dam-Seon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.141-147
    • /
    • 2006
  • Purpose: To compare the clinical and radiological results of anterior cruciate ligament(ACL) reconstruction using hamstring autograft and tibialis tendon allograft. Materials and Methods: Twenty four ACL reconstructions using hamstring autograft and 30 using tibialis anterior tendon altograft were followed up at least 1 year. We performed femoral tunnel fixation with Ligament Anchor(LA) screw and tibial tunnel fixation with biodegradable interference screw. Evaluations included Lysholm knee(LK) score, Tegner activity scale, Lachman test, Pivot-Shift test, Quardriceps atrophy, incision site numbness, anterior knee pain and instrumented anterior laxity with $Telos^{(R)}$ device. Results: Preoperativ mean LK score was $60.3(18{\sim}82)$ in autograft group and 61.2(25-80) in allograft group. Mean LK score improved to $91.6(68{\sim}100)\;and\;92.6(77{\sim}100)$ respectively. Activity level, using Tegner activity scale, slightly decreased compared with that of Preinjury state in both groups. Lachman test, pivot-shift test, Quadriceps atrophy, anterior knee pain, incision site numbness, and anterior drawer test using $Telos^{(R)}$ device showed no significant difference between two groups (p>0.05). Conclusion: In performing the ACL reconstruction, there was no statistically significant difference between hamstring autograft group and tibilis anterior allograft group in clinical or in radiological results.

  • PDF

PCL Reconstruction using Arthroscopic Posterior Transseptal technique (관절경하 후격막 통과 도달법을 이용한 후방 십자 인대의 재건술)

  • Kim, Jin-Goo;Kang, Yeong-Hun;Kang, Kyoung-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.111-116
    • /
    • 2000
  • Purpose : We reviewed the results of arthroscopic posterior cruciate ligament reconstruction using Achilles tendon allograft, and the efficacy of the surgical technique using gradual tibial tunneling and posterior transseptal technique. Materials and Methods : From september 1997 to September 1999, 8 patients with complete PCL injury were treated by arthroscopic PCL reconstruction using Achilles tendon allograft. Mean follow-up period was 21.7 months. Mean preoperative posterior laxity was 14mm. The clinical outcome was assessed by Telos stress test, Lysholm knee score and IKDC score. Result : There was no complication such as infection and neurovascular injury. Posterior translation using Telos device was less than 5mm in 6 cases$(75\%)$, and between 6 to 10mm in 2 cases$(25\%)$. The mean Lysholm knee score was 45 preoperatively and improved to 87 postoperatively. In IKDC system, 2 of 8 patients were group A and 6 were group B. Conclusion : Arthroscopic PCL reconstruction using achilles tendon allograft and posterior transseptal technique shows reliable stability, short operative time and minimizing donor site morbidity but needs more long term follow-up.

  • PDF

Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw (슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Jeong Kwang Cheul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.69-73
    • /
    • 2001
  • Purpose : To evaluate the clinical results and widening of bony tunnel after anterior cruciate ligament(ACL) reconstruction using hamstring tendon with Ligament Anchor(LA) screw, which is newly designed fur fixation of graft into femur. Materials and Methods : Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon were included in this study. The graft was fixed with LA screw at femoral tunnel and with bioabsorbable interference screw at tibial tunnel. The average period of follow-up was 28 months. The clinical results such as physical examination and Lysholm knee score and radiological results. widening of bony tunnel and instrumented anterior laxity test with $Telos^{\circledR}$(Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results . The Lysholm knee score was 60.0 in average preoperatively and improved to 94.0 in average at follow up. On the Lachman test, there were mild(+) instability in 16 cases, moderate(++) in 24, severe(+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 20 lb was 12.9mm in average preoperatively, and was decreased to 3.1mm in average follow-up. The femoral tunnel was widened from 10.6mm postoperatively to 12.7mm$(21.1\%)$ at follow up on antero-posterior plane and from 10.7mm to 12.4mm$(16.5\%)$ on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm$(20.7\%)$ on antero-posterior plane and from 9.9mm to 11.7mm$(18.9\%)$ in lateral plane. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixatives in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel.

  • PDF

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF

Posterior Cruciate Ligament Reconstruction by Tibial Inlay Technique (Tibial Inlay 방법을 이용한 후방 십자 인대 재건술의 결과)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Kim Jong Seon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.80-84
    • /
    • 2001
  • Purpose : To evaluate the clinical and radiological results of posterior cruciate ligament reconstruction(PCL) by tibial inlay technique. Materials and Methods : Twenty four patients(25 cases), who underwent reconstruction of posterior cruciate ligament by tibial inlay technique and were followed up for at least 2 years, were reviewed retrospectively. Mean age at operation was 35 years and mean period of follow up was 34 months. Clinically Lysholm knee socre, posterior drawer test and step off sign were evaluated. Instrumented posterior laxity test with $Telos^{\circledR}$ device(Telos stress device; Austin & Associates, Inc., Polston, US) was performed. Results : Lysholm knee score was improved from 56.9 points preoperatively to 94.6 points at fellow up. Posterior drawer test showed grade II instability in 1 case, grade III in 18 and Grade IV in 6 preoperatively and improved to grade I In 12, grade II in 10 and grade III in 3 at follow up. Step off signs were changed from -10mm in 6 cases, -5mm in 18 and flush in 1 preoperatively to -5mm in 3, flush in 10 and +5mm in 12 at follow up. Side to side difference of instrumented posterior laxity test was improved front 13.6mm preoperatively to 4.3mm at follow up. Conclusions : PCL reconstruction by tibial inlay technique is considered to be a good treatment method to restore posterior stability of the knee, which could result in satisfactory clinical and radiological results at more than 2 years' follow up.

  • PDF