• Title/Summary/Keyword: Telescopic

Search Result 107, Processing Time 0.03 seconds

A clinical report of hybrid telescopic double crown denture with friction pin in a failed double crown denture case (실패한 이중관 국소의치에서 하이브리드 텔레스코픽 이중관 국소의치를 이용한 임상증례)

  • Park, Jong-Hoon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.201-209
    • /
    • 2021
  • In removable partial dentures, many types of retentive systems have been studied and applied in clinical treatment. One of those systems is the double crown denture system which is widely used in European countries such as Germany and Sweden. Telescopic double crown dentures have several advantages such as convenience in maintaining oral hygiene, enabling to transfer occlusal force along the long axis of the abutment, and secondary splinting effect between the abutments which leads to higher clinical performance compared to conventional removal partial dentures. In this clinical case, the patient was initially restored with a maxillary hybrid telescopic double crown denture with friction pin using remaining natural teeth as abutments. After 7 years, due to lack of recall check-up and poor oral hygiene, the abutment teeth were affected by periodontitis and 4 out of 5 of the abutment teeth had to be extracted. 3 additional implants were placed and the original abutment tooth with the inner crown was maintained. The mandible had fixed prostheses including implants but nevertheless, with strategic implant placement, the patient adapted well and was satisfied with the new maxillary tooth-implant combined double crown denture.

A clinical case of hybrid telescopic double crown using friction pin with an isolated few remaining teeth (고립된 소수 잔존치 환자에서 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관 국소의치의 임상증례)

  • Sohn, Sang-Hyuk;Cho, Jin-Hyun;Cho, Sung-Am
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.80-86
    • /
    • 2016
  • A few authors have reported good clinical results using double crown removable partial denture (RPD) with a few remaining teeth. Hybrid telescopic double crown is a good indication for a patient with poor periodontal condition and/or few remaining teeth after extraction, especially located in cross-arch position. In this case, there was a poor periodontal condition with teeth mobility. Several teeth with poor prognosis were extracted. Remaining anterior teeth was restored with fixed prostheses and edentulism was restored with Kennedy class I removable partial denture in maxilla. In mandible, it was hard to restore with clasp removable partial prostheses because of bilaterally isolated remaining teeth so that hybrid double crown removable partial denture with friction pin was suitable for this case. The objective of this report is to discuss the characteristics and the utility of hybrid double crown prostheses using a few remaining teeth in mandible.

High Quality Tissue Miniarray Technique Using a Conventional TV/Radio Telescopic Antenna

  • Elkablawy, Mohamed A.;Albasri, Abdulkader M.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1129-1133
    • /
    • 2015
  • Background: The tissue microarray (TMA) is widely accepted as a fast and cost-effective research tool for in situ tissue analysis in modern pathology. However, the current automated and manual TMA techniques have some drawbacks restricting their productivity. Our study aimed to introduce an improved manual tissue miniarray (TmA) technique that is simple and readily applicable to a broad range of tissue samples. Materials and Methods: In this study, a conventional TV/radio telescopic antenna was used to punch tissue cores manually from donor paraffin embedded tissue blocks which were pre-incubated at $40^{\circ}C$. The cores were manually transferred, organized and attached to a standard block mould, and filled with liquid paraffin to construct TmA blocks without any use of recipient paraffin blocks. Results: By using a conventional TV/radio antenna, it was possible to construct TmA paraffin blocks with variable formats of array size and number ($2-mm{\times}42$, $2.5-mm{\times}30$, $3-mm{\times}24$, $4-mm{\times}20$ and $5-mm{\times}12$ cores). Up to $2-mm{\times}84$ cores could be mounted and stained on a standard microscopic slide by cutting two sections from two different blocks and mounting them beside each other. The technique was simple and caused minimal damage to the donor blocks. H&E and immunostained slides showed well-defined tissue morphology and array configuration. Conclusions: This technique is easy to reproduce, quick, inexpensive and creates uniform blocks with abundant tissues without specialized equipment. It was found to improve the stability of the cores within the paraffin block and facilitated no losses during cutting and immunostaining.

Stress Analysis of Abutment and Supporting Tissues by Changing Angles and Heights of Konus Telescope Inner Crown (Konus Telescopic Denture의 내관 각도 및 높이에 따른 지대치 및 지지조직의 응력 분석)

  • Vang, Mong-Sook;Gettleman, Lawrence
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.139-151
    • /
    • 2003
  • This study was to evaluate and to compare the compressive strength and the displacement effecting the abutment or the residual ridge which are transformed by the angle and the heights of the konus denture inner crown when restorating the unilateral konus denture by using the mandibular canine and the 1st premolar as an abutment. The author made 9 different models for different inner crown heights and konus angles. The inner crown height were divided to 5mm, 6mm, and 7mm and konus angles was divided to $4^{\circ}$, $6^{\circ}$, and $8^{\circ}$. And then in each model, 5kg of $15^{\circ}$ mesial load was stressed on the central fossa of the 1st premolar and the 1st molar. The stresses and displacement were measured using the finite element analysis. The results were as follows 1. The maximum compressive strength was shown on the connective area of the abutment and the denture base. 2. As the angle of the inner crown becomes increased, the compressive strength was shown smaller. 3. As the height of the inner crown becomes increased, the maximum compressive strength was shown smaller while the compressive strength of the root apex and the residual ridge showed larger. 4. When the stress was loaded only on the 1st premolar, the more compressive strength was concentrated on the root apex area of the 1st premolar. 5. When the stress was loaded only on the 1st premolar, the compressive strength was concentrated uniformly on the abutment and the residual ridge. 6. When the stress was loaded only on the 1st molar, the maximum displacement was shown on the distal part of the residual ridge.

A PHOTOELASTIC STRESS ANALYSIS ON TOOTH SUPPORTING STRUCTURE AND RESIDUAL RIDGE ACCORDING TO DENTURE DESIGN FOR REMAINING MANDIBULAR CANINES (하악 견치 잔존시 의치 설계에 따른 치아 지지조직 및 잔존치조제의 광탄성 응력분석)

  • Kim, Il-Pyung;Koh, Joon-Won;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.486-503
    • /
    • 1997
  • The purpose of this study was to evaluate the stress patterns developed in abutment and residual ridge according to removable denture design in case of remaining mandibular canines. The removable denture designs in this study were as foolows : 1. Removable partial denture with non-splinted abutment 2. Removable partial denture with splinted abutment 3. Overdenture with telescopic crown 4. Overdenture with O-Ring attachment 5. Overdenture with combination bar attachment Photoelastic stress analysis was used to record the isochromatic fringe patterns and to calculate principal stress components at measuring points. The results were as follows : 1. In case of removable partial denture with non-splinted abutment, stress of root area at the loaded side was the largest. No significant differences in stress of root area were observed between loaded side and unloaded side. 2. No significant differences in stress of residual ridge at the loaded side were observed between removable partial denture with splinted abutment and removable partial denture with non-splinted abutment. 3. In case of combination bar attachment retained overdenture, stress of root area was the largest and in case of telescopic crown retained overdenture, stress of root area was the lowest. 4. In case of attachment retained overdenture, stress of residual ridge was lower but stress of root area was larger than in case of removable partial denture.

  • PDF

A Study on the Structural Safety of Tower Crane Telescoping Work according to Wind Speed and Load (타워크레인 텔레스코핑 작업의 풍속 및 하중에 대한 구조 안전성 연구)

  • Jung, Sung-Lyoung;Lee, Do-Geun;Paik, Shinwon;Shin, Sang-Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.1
    • /
    • pp.9-17
    • /
    • 2021
  • This study analyses the load imbalance of the tower crane used in telescoping work for structural safety, owing to the difference in wind speed and balance weight position. This is because wind speed and position of the balance weight have a significant impact on the structural stresses of a tower crane during telescoping work. Therefore, structural analysis was performed on the 290HC model, which is often used at construction sites and has only one cylinder installed. Moreover, two models were classified to determine the load acting on the connecting part of the telescopic cage to slewing platform and the cylinder. Five types of balance weight positions were applied at regular intervals from jibs; moreover, four types of wind load criteria were differently applied. Hence, the telescopic cage columns were destroyed at all balance weight positions at a wind speed of 30 m/s and only at certain locations at a wind speed of 20 m/s. Furthermore, failures occurred for cylinders, torsional, and bending at wind speeds of 30 m/s and 20 m/s, load imbalances above the allowable thresholds considering the safety factor. In addition, the load imbalance in the telescoping work also varied depending on the position of the balance weights. The results of these studies have validated that the current standards of adjusting the appropriate position of the balance weights on the jib are completely valid, with the telescoping work to be executed only at wind speeds of less than equal to 10 m/s.

Structural and Vibrational Characteristics for the Scaffolding System of LNG Cargo Containment (LNG 화물창 비계 시스템의 구조해석 및 진동 특성)

  • Ryu, B.J.;Shin, G.B.;Nahm, Y.E.;Oh, B.J.;Baek, S.G.;Kim, H.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1197-1202
    • /
    • 2007
  • The paper deals with the structural analysis and vibration test for the scaffolding system of LNG cargo containment. The eight-stories scaffolding system has telescopic area, working area, coner area and storage area in real system. In the structural analysis, the maximum displacement and stress of the each floor for the scaffolding system are investigated by finite element method. In the vibrational analysis, the natural frequencies and mode shapes for 8-stories scaffolding system of the LNG cargo containment are investigated. In order to compare theoretical natural frequencies with experimental ones, small size of 2-step scaffolding structure is used, and the theoretical results for natural frequency have a good agreement with experimental ones.

  • PDF

An innovative prostheses design for rehabilitation of severely mutilated dentition: a case report

  • Abduo, Jaafar
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • Partial edentulism has multiple implications in relation to function, esthetics and future rehabilitative treatment. This case report illustrates the management of a patient with extreme consequences of partial edentulism. The main clinical findings were unopposed remaining teeth, overeruption of the remaining teeth, loss of vertical dimension of occlusion, and significant disfigurement of the occlusal plane. Following the diagnostic procedure, a well-coordinated prosthodontic treatment involving liaison with other dental disciplines was indicated. The management involved an innovative combination of fixed and removable prostheses in conjunction with crown lengthening surgery and strategic implant placement. Series of provisional prostheses were applied to facilitate the transition to the final treatment.

Structural and Vibration Characteristics for the Scaffolding System of LNG Cargo Containment (LNG 화물창 비계 시스템의 구조해석 및 진동 특성)

  • Oh, B.J.;Ryu, B.J.;Lee, Y.S.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.6
    • /
    • pp.546-554
    • /
    • 2010
  • The paper deals with the structural analysis and vibration test for the scaffolding system of LNG cargo containment. The eight-stories scaffolding system has telescopic area, working area, coner area and storage area in real system. In the structural analysis, the maximum displacement and stress of the each floor for the scaffolding system are investigated by finite element method. In the vibrational analysis, the natural frequencies and mode shapes for 8-stories scaffolding system of the LNG cargo containment are investigated. In order to compare theoretical natural frequencies with experimental ones, small size of 2-step scaffolding structure is used, and the theoretical results for natural frequency have a good agreement with experimental ones.