• 제목/요약/키워드: Telescopic

검색결과 106건 처리시간 0.023초

Telescopic Boom의 Stick-Slip에 의한 Cylinder의 압력변화 (Stick-Slip Pressure Variations in a Cylinder of Telescopic Boom)

  • 김신;이형직;정재연
    • Tribology and Lubricants
    • /
    • 제18권1호
    • /
    • pp.55-60
    • /
    • 2002
  • In many dynamic systems, there are unwanted oscillation which may arise the reduction of performance. Especially in low sliding speed condition, the stick-slip is an important issue because it because unstable motion as well as inaccurate position control in the system. Most previous works on the stick-slip are, however, only concerned with simple modeling under the condition of constant normal force. The normal force and the amount of hydraulic oil are variable with a cylinder stroke in the telescopic boom. This paper presents the pressure variations during stick-slip with the cylinder of telescope boom. Pressure variations by stick-slip has a similar pattern to that of single mass-spring model. The stick-slip is gradually decreased by means of increased flow rate.

Slenderness ratio of telescopic cylinder-columns

  • Sugiyama, Yoshihiko;Ohtomo, Takamitsu
    • Structural Engineering and Mechanics
    • /
    • 제12권3호
    • /
    • pp.329-339
    • /
    • 2001
  • The present paper deals with the effective slenderness ratio of telescopic cylinders as a long column having different cross sections. Firstly, the slenderness ratio defined in the current standard for the telescopic cylinders is discussed to point out some difficulties which arise when the ratio is applied to the column having different cross sections. Secondly, a new effective slenderness ratio is proposed for columns having different cross sections by introducing a partial effective slenderness ratio. Finally, the proposed slenderness ratio is applied, for extending and development of discussion, to a two-staged column having piece-wise constant cross sections and a cylindrical column having linearly varying diameters.

전치부 과개교합을 가진 상하악 부분 무치악 환자에서의 상악 하이브리드 텔레스코픽 이중관 국소의치와 하악 고정성 보철물을 이용한 치료의 11년 경과관찰 증례 (Prosthetic treatment for patient with anterior overbite and partial edentulism using maxillary hybrid telescopic double crown RPD and mandibular fixed prostheses: A 11-yr follow-up)

  • 최현석;조진현
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.415-421
    • /
    • 2021
  • 소수 잔존치가 남아있거나 치주적으로 불리한 경우 전통적인 가철성 국소의치의 생역학적 예후가 불분명하다. 이러한 경우, 하이브리드 텔레스코픽 이중관 국소의치(hybrid telescopic double crown RPD)는 성공적인 치료의 대안이 될 수 있다. 이 치료방법의 경우 지대치 간의 이차고정 효과가 있으며 응력의 방향이 수직적이고, 지대치 발치 시에 의치의 수리가 용이하다는 점에서 전통적인 가철성 국소의치에 비해 장점을 보인다. 본 증례에서는 전치부의 과개교합을 가진 상하악의 부분 무치악 환자에 있어 상악에는 이중관 의치, 하악에는 임플란트 및 고정성 보철치료가 시행되었다. 장기간 동안 경과관찰 및 유지관리 치료를 시행한 결과, 기능 및 심미적인 면에서 만족할 만한 성과를 얻었기에 이를 보고하고자 한다.

이중관 구조 하악 임플랜트 피개의치의 응력 분포에 관한 유한요소법적 분석 (Finite Element Analysis of Stress Distribution on Telescopic System for Mandibular Implant Supported Overdenture)

  • 오정란;우이형;이성복;백진
    • 대한치과보철학회지
    • /
    • 제46권4호
    • /
    • pp.359-371
    • /
    • 2008
  • 연구목적: 본 연구에서는 하악의 동일한 부위에 4개의 임플랜트를 식립하여 임플랜트 피개의치를 설계하는 경우, 바 구조와 이중관 구조 간의 응력분포에 대해 비교 분석하고자 하였다. 연구재료 및 방법: 하악골, 하악골에 식립한 4개의 임플랜트, 일차고정의 바 연결 상부구조, 이차고정의 이중관 상부구조를 삼차원 유한요소 모델링하였고, 상부 구조물에 최대 교두 감합위를 재현하는 수직하중과 측방운동시 작업측의 군기능을 재현하는 경사하중을 가하고, 최대 응력과 응력분포를 하악골, 임플랜트 지대주, 임플랜트 상부 구조물에서 분석하였다. 결과: 1. 악골에서의 최대 응력값은 경사하중을 제외하고 수직하중과 작업측 경사하중에서 이중관 구조가 바 구조에 비해 다소 적은 응력값을 보였다. 이중관 구조가 바 구조에 비해 비교적 악골 전체에 고르게 응력이 분포되었다. 2. 지대주에서는 모든 하중 조건에서 이중관 구조가 바 구조에 비해 낮은 응력값을 보였다. 응력 분포 양상은 두 구조에서 모두 비슷한 양상을 나타내었으며, 최후방 지대주의 원심면에 응력이 집중되었다. 3. 상부구조물에서는 모든 하중 조건에서 이중관 구조가 바 구조에 비해 높은 응력값을 나타냈다. 그러나, 바 구조에서는 바의 각 중심부와 지대주와의 연결부위, 지대주의 치경부에 응력이 집중된 반면, 이중관 구조에서는 상부 구조물 전체에 비교적 고른 응력 분포를 보였다. 결론: 본 연구 결과 이중관 구조가 바 구조보다 악골과 지대주에서는 더 낮은 응력을, 상부 구조물에서는 더 큰 응력을 나타냈다. 상부 구조물에 비교적 크게 전달되는 응력을 견딜 수 있는 상부구조물의 설계와 재료 선택만 이루진다면, 응력분포 면에서 이차고정을 하는 이중관 구조가 일차 고정하는 바 구조에 비해 유리하리라 생각된다.

telescope형 및 Clasp형 유지장치를 이용한 국소의치 지지조직의 응력분포에 관한 삼차원 유한요소법적 연구 (A STUDY ON THE STRESS DISTRIBUTION OF ABUTMENT TEETH AND RESIDUAL RIDGE AREA BETWEEN TELESCOPIC AND CLASP TYPE RPD BY FEM METHOD)

  • 곽재영;김광남;장익태;허성주
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.104-126
    • /
    • 1999
  • The purpose of this study was to compare and evaluate the stress distribution and displacement developed in the abutment teeth and residual ridge area by madibular unilateral distal extension removable partial denture with 2 different retainer designs. The retainers on right and left canine and right 2nd molar were Alters clasp in one model and telescopic crown in the other model. The stress distribution of abutment teeth and residual ridge area on two model were compared and analyzed with 3-dimensional finite element method. 150N and 400N forces were applied vertically, 30 degree and horizontally on the central fossa area of left 1st molar of the removable partial denture, and then stress distribution patterns were analyzed and compared. The results were as follows 1. As the magnitude and angulation of applied force were increased, the magnitude of stress on the right and central residual ridge area and the right canine of the telescopic type increased and comparing to those of the Alters clasp type. 2. As the magnitude and angulation of applied force were increased, the mesial direction of displacement on the right residual ridge area and the right tooth of the telescopic type increased and the distal direction of displacement on left residual ridge area and the left canine increased comparing to those of Akers clasp type. 3. As the vertical force was applied, the distal direction of the displacement of the right tooth were greater and that of the left canine was smaller and the upward displacement of the right canine was greater in telescopic partial denture than those of Akers clasp type. 4. As the 30 degree force was applied, the mesial direction of the displacement of the right tooth were greater and the distal direction of the displacement of the left canine was smaller and the upward displacement of the right canine was greater in telescopic partial denture than those of Akers clasp type. In the horizontal force the results were same in right area tooth but the distal direction of displacement was greater in left canine. 5. In both removable partial dentures, as the magnitude and degree of force were increased, the stress and displacement were increased. The compressive force was dominative than the ten sile force. 6. In both removable partial dentures, the magnitude of stress was greater on mucosal tissue area than that of the alveolar bone area on distal extension residual ridge area but the result was reversed on anterior residual ridge area. The displacement was always greater on mucosal tissue area than that of alveolar bone area.

  • PDF

THE PERFOMANCE OF GROUNDBASE MOBILE PLATFORM FOR C-BAND MICROWAVE SCATTEROMETER SYSTEM

  • Aziz H.;Mahmood N.N.;Ali A.;Jamil H.;Mahmood K.A.;Ahmad Z.;Ibrahim N.;Brevern P.V.;Chuah H.T.;Koo V.C.;Sing L.X.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.61-63
    • /
    • 2004
  • The procurement of a mobile microwave scatterometer platform involved the consideration to ensure a mobile platform and equipment selected full-filled technical requirement and safety standard in Malaysia. Designing, and modification works involved engineering methodology in determining and selecting a suitable hydraulic telescopic boom that suit a selected mobile platform available locally. The mobile platform is a delivery system for microwave remote sensing microwave scatterometer and other accessories to any locations in Malaysia. Total loading to be carried by the mobile platform is 4500 kg and its overall weight must be 16,000 kg as recommended by hydraulic telescopic boom manufacturers. The telescopic boom will elevate microwave scatterometer system including the antenna to a maximum height of 27 m, and can also be rotated through $3600^{\circ}$. A mechanism is incorporated in the system to enable tracking or monitoring angular movement of the hydraulic telescopic boom when positioned towards predetermined target.

  • PDF

THE MECHANICAL DESIGN AND CONSTRUCTION OF A TRUCK MOUNTED SCATTEROMETER SYSTEM

  • Aziz, H.;Mahmood, N.N.;Ali, A.;Ibrahim, N.;Ahmad, Z.;Mahmood, K.A.;Jamil, H.;Brevern, P.V.;Koo, V.C.;Sing, L.K.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1009-1011
    • /
    • 2003
  • The procurement of mobile microwave scatterometer involve the consideration to ensure vehicle and equipment selection full-filled technical requirement and safety standard in Malaysia. Designing, and modification works involve engineering methodology in determining and selecting a suitable hydraulic telescopic boom that suit a selected vehicle available from the market. The vehicle is also a delivery system for microwave remote sensing equipment and other accessories to any locations in Malaysia. Total loading to be carried by the vehicle is about 4500 kg and its overall weight must be 16,000 kg as recommended by hydraulic telescopic boom manufacturers. The telescopic boom will elevate microwave scatterometer system and antenna to a maximum height of 27 m, and can also be rotated through 360$^{\circ}$. A mechanism is incorporated in the system to enable tracking or monitoring angular movement of the hydraulic telescopic boom when positioned towards required target.

  • PDF

하악 소수 잔존치에서 텔레스코픽 의치를 이용한 수복 증례 (A case report on telescopic denture with a small number of residual teeth in mandible)

  • 오상민;이재훈
    • 대한치과보철학회지
    • /
    • 제53권1호
    • /
    • pp.46-50
    • /
    • 2015
  • 하악의 잔존 치조제가 얇고 낮은 증례에서 국소의치를 이용한 수복은 잔존 치조제에서 적절한 전후방의 안정성 및 지지를 얻을 수 없어 환자에게 불편함을 주고 치조제에 과도한 교합력을 주게 된다. 또한 서로 멀리 떨어진 소수의 잔존치가 남았을 경우 스플린트하기 어렵고, 스플린트를 하지 않을 경우 고립 지대치가 되어 현명한 치료가 될 수 없다. 이와 같은 경우 텔레스코픽 시스템은 클래스프 의치에서 발생될 수 있는 치아에 작용하는 무리한 측방하중을 줄여주며, 안정적이고 확실한 유지력과 견고성을 갖는다는 장점이 있다. 본 증례는 전반적인 중등도의 치주염으로 인해 상악은 무치악, 하악은 소수 잔존치가 남은 상태에서, 상악은 총의치, 하악은 텔레스코픽 의치로 수복한 증례이다. 치료 계획 시 서로 멀리 떨어진 하악 소수 잔존치가 남고, 적절한 지지를 얻을 수 없는 치조제를 가져 클레스프 의치를 수복하더라도 많은 불편함과 어려움이 있을 것으로 판단되어, 텔레스코픽 의치로 수복하였다.