Waveform analysis of leakage current on silicon insulator for various environment condition variation (환경조건변화에 대한 실리콘애자의 누설전류 파형분석)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.7 no.2
    • /
    • pp.69-76
    • /
    • 2004
  • This paper presents the results of spectral analysis about waveforms and leakage current waveforms on contaminated silicon insulators under various environment conditions.(salt fog, clean fog, rain). The larger the leakage current during 200ms, the higher the power spectrum at 60Hz. If contaminated insulators suffers from high salt density fog, the leakage current occurs with high crest value intermittently, results in the low spectrum. Analysis of leakage current data showed that this electrical activity was characterized by transient arcing behavior contaminants are deposited on the insulator surface during salt fog tests. This provides a path for the leakage current to flow along the surface of the insulator. It is important to have an indication of the pollution accumulation in order to evaluate the test performance of a particular insulator. If the drop in surface resistivity is severe enough, then the leakage current may escalate into service interrupting flashover that degrade power quality.

  • PDF

Development of Vehicle Status Alerts System for Personal Information Leakage Protection using the NFC-based GCM Service (개인정보 유출 방지를 위한 NFC 기반 GCM 서비스를 이용한 차량 상황 알림 시스템 개발)

  • Kang, Hyun-Min;Choi, Hyun-Su;Cha, Kyung-Ae
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.317-324
    • /
    • 2016
  • This paper proposes a message transfer application using smartphone with NFC(Near Field Communication) and GCM(Goolge Cloud Messaging) technology for prevention of personal information leakage. In implementing for the proposed system, we design a NFC-based vehicle status alerts service which make it possible to communicate with smartpone message without phone-number between a car driver and an unspecified person. The application provides message communication mechanism without exposing the real phone number, using the NFC tag written with the driver's smartphone device ID and GCM push messages. Through the evaluation result of the actual implemented application, the proposed system can be efficient technology in protection for leakage of personal information such as personal phone- number in daily life.

A Study on the Leakage Current Voltage of Hybrid Type Thin Films Using a Dilute OTS Solution

  • Kim Hong-Bae;Oh Teresa
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.1 s.14
    • /
    • pp.21-25
    • /
    • 2006
  • To improve the performance of organic thin film transistor, we investigated the properties of gate insulator's surface according to the leakage current by I-V measurement. The surface was treated by the dilute n-octadecyltrichlorosilane solution. The alkyl group of n-octadecyltrichlorosilane induced the electron tunneling and the electron tunneling current caused the breakdown at high electric field, consequently shifting the breakdown voltage. The 0.5% sample with an electron-rich group was found to have a large leakage current and a low barrier height because of the effect of an energy barrier lowered by, thermionic current, which is called the Schottky contact. The surface properties of the insulator were analyzed by I-V measurement using the effect of Poole-Frankel emission.

  • PDF

Design of Gate-Ground-NMOS-Based ESD Protection Circuits with Low Trigger Voltage, Low Leakage Current, and Fast Turn-On

  • Koo, Yong-Seo;Kim, Kwang-Soo;Park, Shi-Hong;Kim, Kwi-Dong;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.725-731
    • /
    • 2009
  • In this paper, electrostatic discharge (ESD) protection circuits with an advanced substrate-triggered NMOS and a gate-substrate-triggered NMOS are proposed to provide low trigger voltage, low leakage current, and fast turn-on speed. The proposed ESD protection devices are designed using 0.13 ${\mu}m$ CMOS technology. The experimental results show that the proposed substrate-triggered NMOS using a bipolar transistor has a low trigger voltage of 5.98 V and a fast turn-on time of 37 ns. The proposed gate-substrate-triggered NMOS has a lower trigger voltage of 5.35 V and low leakage current of 80 pA.

An Investigation of Solubility of Aliquat 336 in Different Extracted Solutions

  • Xu, Jianying;Paimin, Rohani;Shen, Wei;Wang, Xungai
    • Fibers and Polymers
    • /
    • v.4 no.1
    • /
    • pp.27-31
    • /
    • 2003
  • A major concern in solvent extraction process is the loss of extractant into the aqueous phase due to its slight solubility in the aqueous phase. Similarly, in membrane extraction processes, extractant loss through extractant leakage from the membrane into the aqueous phase is also a concern. Several published membrane extraction studies using Aliquat 336 ai the extractant, have expressed this concern, but none has studied extractant leakage quantitatively. It is the authors' opinion that the extractant leakage should be considered at a technical parameter of a membrane. In our laboratory active progress has been made in using Aliquat 336 ‘entangled’ into the polymer membranes to remove heavy metal ions from wastewater samples. In this work, we studied the loss of Aliquat 336 from the point of view of its solubility in aqueous solutions. The results showed that the solubilities or Aliquat 3,36 in an aqueous phase acidified with 2 M HCI it about 0.1 g/100 m/ of the solution. This figure provides a useful guideline for evaluating the leakage of the Aliquatoat 336 extractant from the membranes.

Differential Effects of herbicidal Compounds on Cytoplasmic Leakages of Green- and White-Maize Leaf Segments

  • Kim, Jin-Seog;Park, Jung-Sup;Kim, Tae-Joon;Yoonkang Hur;Cho, Kwang-Yun
    • Journal of Photoscience
    • /
    • v.8 no.2
    • /
    • pp.61-66
    • /
    • 2001
  • Using maize green- and white-leaf tissue, we have examined the effect of various chemicals on cytoplasmic leakage with respect to the light requirement or chloroplast targeting for their activities. Oxyfluorfen, oxadiazon, diuron, and paraquat, which are known as representative herbicides acting on plant chloroplasts, caused the electrolyte leakage only in the green tissues, whereas 2, 4-dinitrophenol, rose bengal (singlet oxygen producing chemical) and methyl-jasmoante (senscence-stimulating chemical) play a role both in green- and white-tissue. Benzoyl(a) pyrene, generating superoxide radical upon light illumination, functions only in white tissues. Tralkoxydim, metsulfuron-methyl and norflurazon showed no effect in two tested plant samples. In terms of light requirement in electrolyte leakage activity, diuron, oxyfluorfen, oxadiazon, rose bengal, and benzoyl(a) pyrene absolutely require the light for their functions, but other chemicals did not. based on these results, we could classify into four different response types according to whether chemicals require light or chlroplasts for their action. This classification is likely to be applied to simply and rapidly identify the requirement of light and chlroplasts for the actions of chemicals, thereby it makes easy to characterize many new herbicides that their action mechanisms are unclear, and to elucidate the mode of action of them.

  • PDF

The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current (인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석)

  • Kim, Jae-Hyun;Lim, Young-Bea;Lee, Sang-Ick;Kim, Dong-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.

Relative humidity prediction of a leakage area for small RCS leakage quantification by applying the Bi-LSTM neural networks

  • Sang Hyun Lee;Hye Seon Jo;Man Gyun Na
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1725-1732
    • /
    • 2024
  • In nuclear power plants, reactor coolant leakage can occur due to various reasons. Early detection of leaks is crucial for maintaining the safety of nuclear power plants. Currently, a detection system is being developed in Korea to identify reactor coolant system (RCS) leakage of less than 0.5 gpm. Typically, RCS leaks are detected by monitoring temperature, humidity, and radioactivity in the containment, and a water level in the sump. However, detecting small leaks proves challenging because the resulting changes in the containment humidity and temperature, and the sump water level are minimal. To address these issues and improve leak detection speed, it is necessary to quantify the leaks and develop an artificial intelligence-based leak detection system. In this study, we employed bidirectional long short-term memory, which are types of neural networks used in artificial intelligence, to predict the relative humidity in the leakage area for leak quantification. Additionally, an optimization technique was implemented to reduce learning time and enhance prediction performance. Through evaluation of the developed artificial intelligence model's prediction accuracy, we expect it to be valuable for future leak detection systems by accurately predicting the relative humidity in a leakage area.

A Study on the Construction Methods of Sealer of Injection Type for Leakage Maintenance for Water Leakage and Cracks in Concrete (콘크리트 누수균열의 유지관리를 위한 누수보수용 주입형 실링재 시공방법 연구)

  • Kwon Shi-Won;Oh Mi-Hyun;Kwak Kyu-Sung;Oh Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.1 s.19
    • /
    • pp.87-91
    • /
    • 2006
  • Since water leakage and cracks are not the source of serious problems such as long-term lowering of performance and durability of a stricture, including damages to operating facilities of a structure, damages to internal finishing materials, exhibition, and goods, and pollution of residential environment, they might have led to development of positive coping skills; however, an instant loss of lives or property due to earthquake, explosion, typhoon, or a fire was indeed neglected. In these days, repair materials for leakage cannot help but being taken in temporary way without any noticeable countermeasure. This kind of repair is socially criticized many times that is defective construction even if this costs a lot. It was not arrange the standard for construction methods of sealer of injection type for leakage maintenance, even it has been used various type of construction methods for leakage part. In conclusion, we suggest that the construction methods of sealer of injection type for leakage maintenance for leakage to establish the leakage repairing technology as increase of structure demand. Therefore, it would be possible to provide a stage-by-stage solution by developing systematic research activities among the industry, schools, and research institutes to spread maintenance management techniques globally through technical solution to water leakage and cracks, acquisition of structural safety with prolonged durability for life cycle, reduction of water leakage repair expense s, and so on.

Experimental Study on Development of Air Leakage Model and Performance Characteristics of a Desiccant Rotor (제습로터의 공기누설모델 개발 및 성능 특성에 관한 실험적 연구)

  • Kang, Byung-Ha;Pi, Chang-Hun;Chang, Young-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • This study investigates the pressure leakage characteristics of a desiccant rotor with a brush-type air seal. Through a pressure leakage experiment, a correlation equation for the leakage air flow rate is obtained as a function of the air seal area and pressure difference. Using this equation, an air leakage model for the desiccant rotor is developed. By comparing simulation results with the experimental results for the desiccant rotor, the accuracy of the air leakage model is demonstrated. A performance test of a desiccant rotor with various air flow rates is carried out. Using the air leakage model, the effective mass flow rate and air leakage rate are found. In addition, the characteristics of the air leakage are analyzed for a desiccant cooling system using the developed air leakage model.