• 제목/요약/키워드: Technology leakage

검색결과 1,721건 처리시간 0.03초

배급수관망에서의 누수복원량 산정방법 (Estimation method of natural rate of rise of leakage in water distribution system)

  • 진샘물;김경필;구자용
    • 상하수도학회지
    • /
    • 제33권4호
    • /
    • pp.299-309
    • /
    • 2019
  • Waterworks facilities inevitably experience some amount of leakage even if there is a lot of investment or state-of-the-art technology that is applied such as DMA(District Metered Area) system construction, leakage detection, repair, pipe rehabilitation, etc. The primary reason is the leakage is naturally restored over time. In the UK, this restoration characteristic is defined as NRR(Natural rate of rise of leakage) and used to decision making for prioritizing active leakage control of DMAs. However, this restoration characteristic is well recognized, but researches on NRR in the water distribution system are insufficient in Korea. In this study, the estimation method of NRR was developed suitable for applicating in Korea considering of SCADA data, water infrastructure, and water usage patterns by modification of the UK's NRR method. The proposed method was applied to 9 DMAs and verified it's applicability by comparing with the other water loss performance indicators. It is expected that the proposed method can be used to support decision making for sustainable NRW(Nor-revenue water) management in the water distribution system.

PSCAD/EMTDC를 이용한 ESS의 누설전류 모델링에 관한 연구 (A Study on Modeling of Leakage Current in ESS Using PSCAD/EMTDC)

  • 김지명;태동현;이일무;임건표;노대석
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.810-818
    • /
    • 2021
  • ESS의 누설전류는 PCS(Power Control System)측 누설전류와 계통불평형 전류로 인한 누설전류로 구분되는데, PCS측의 누설전류는 정상 상태 운전 시, IGBT(Insulated Gate Bipolar Transistor) 스위칭의 전압 변화량과 IGBT와 방열판 사이에 존재하는 기생 커패시턴스에 의해 발생한다. 또한, 계통불평형 전류에 의한 누설전류는 불평형 부하로 인해 발생한 불평형 전류가 Yg-∆ 결선방식의 3각 철심이 적용된 태양광전원 연계형 변압기의 중성선을 통해 ESS로 유입된다. 따라서, 본 논문에서는 방열판 유도공식을 통해 산정한 기생 커패시턴스에 의하여 PCS측의 누설전류 발생 메커니즘을 제시하고 또한, 계통불평형에 의한 ESS측의 누설전류 발생 메커니즘을 제안한다. 이를 바탕으로, 배전계통 상용해석 프로그램인 PSCAD/EMTDC를 이용하여 배터리부, PCS부, AC전원부로 이루어진 PCS측의 누설전류 발생 메커니즘과 배전 계통부, 불평형 부하부, ESS부로 이루어진 계통불평형에 의한 ESS측의 누설전류 발생 메커니즘을 모델링하고, 누설전류의 특성을 평가한다. 상기의 모델링을 바탕으로 시뮬레이션을 수행한 결과, 외함의 저항과 접지저항의 크기에 따라 PCS측의 누설전류는 7[mA]에서 34[mA]로, 계통불평형에 의한 배터리 외함으로 흐르는 누설전류는 3.96[mA]에서 10.76[mA]로 증가하여 배터리측에 큰 영향을 미침을 알 수 있었다.

상수도관로 누수신호의 특성 분석을 위한 누수 실험시설 개발 (Development of leakage test facility for leak signal characteristic analysis in water pipeline)

  • 박상혁;곽필재;이현동;최창호
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.459-469
    • /
    • 2017
  • A real scale leakage test facility was developed to study the leak signal characteristics of water supply pipelines, and then leak tests were carried out. The facility was designed to overcome the limited experimental circumstances of domestic water supply pipeline experimental facilities. The length of the pipeline, which was installed as a straight line, is 280m. Six pipes were installed on a 70m interval with different pipe material and diameters that are DCIP(D200, D150, D100, D80), PE(D75) and PVC(D75).The intensity of the leakage is adjusted by changing the size of the leak hole and the opening rate of ball valve. Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise sources which, deteriorate the quality of measured leak signal, the facility was built at a quiet area, where traffic and water consumption by customers is relatively rare. In addition, the usage of electric equipment was minimized to block out noise and the facility was operated using manual mode. From the experimental results of measured leakage signal at the facility, it was found that the signal intensity weakened and the signal of high frequency band attenuated as the distance from the water leakage point increased.

Dependence of Stress-Induced Leakage Current on Low Temperature Polycrystalline Silicon TFTs

  • Chen, Chih-Chiang;Chang, Jiun-Jye;Chuang, Ching-Sang;Wu, Yung-Fu;Sheu, Chai-Yuan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.622-625
    • /
    • 2003
  • The dependence of stress-induced leakage current on LTPS TFTs was characterized in this study. The impacts of poly-Si crystallization, gate insulator, impurity activation, hydrogenation process and electrostatic discharge damage were investigated. It was observed more TFTs instable characteristic under those process-assisted processes. According to the LTPS roadmap, smaller geometric and low temperature process were the future trend and the stress-induced leakage current should be worthy of remark.

  • PDF

보안교육과 보안관리 역량의 상관관계 분석: 인가된 내부자 기밀유출사례를 중심으로 (An Analysis of Relationship between Industry Security Education and Capability: Case Centric on Insider Leakage)

  • 이치석;김양훈
    • 한국전자거래학회지
    • /
    • 제20권2호
    • /
    • pp.27-36
    • /
    • 2015
  • 국가 상대로 한 국가기밀유출과 더불어 최근 산업 기술유출은 점점 늘어가고 유출의 범위가 기술유출 중심에서 정보통신, 전기전자, 방위산업, 전략물자 불법수출, 외국의 경제 질서교란, 지식재산침해 등 신 경제안보 분야로 다양화되는 추세로 유출 피해는 유출된 기업에 피해를 줄 뿐만 아니라 국가의 이익과 국내 산업 전반에 영향을 끼칠 수 있다. 국가정보원 산업기밀 보호센터 통계에 따르면, 기술유출의 주된 원인은 해킹과 악성코드와 같이 외부에 의한 것뿐 아니라 전 현직직원 등 내부유출이 약 80%를 차지하며, 협력업체 의한 기술유출이 뒤를 이어 금전유혹과 개인의 이익으로 인한 기술유출이 계속해서 꾸준히 증가하고 있다. 그러나 그간의 연구들은 핵심자산 유출을 방지하기 위하여 기업의 보안역량을 측정하거나, 관리를 위한 측정지표를 개발하는 연구가 주를 이루고 있었으며, 가장 핵심이 되는 기업구성원들의 보안활동에 대한 기초연구가 미흡한 상황이다. 따라서, 본 연구에서는 보안 활동에 가장 기초가 되는 보안교육이 기업의 보안역량에 미치는 영향에 대해 분석하였다. 그 결과, 보안교육은 보안역량에 양(+)의 상관관계를 나타내는 것으로 분석되었다.

광반응사출성형 시 캐비티 엣지에서 발생하는 미세누출현상에 관한 해석적 연구 (A numerical study on micro leakage behaviors at cavity edge during photo reaction injection molding)

  • 라문우
    • Design & Manufacturing
    • /
    • 제10권3호
    • /
    • pp.8-13
    • /
    • 2016
  • Despite technological advance, there have been several troubles in photo reaction injection molding (photo RIM) to produce ultra thin light guide panels (LGPs). In this study, micro leakage problem at cavity edge during photo RIM was investigated numerically. In order to obtain optimal processing conditions, we regulated inlet pressure of injected resin at the cavity edge and figured out micro leakage behaviors. At low inlet pressure (less than 100 Pa), though the micro leakage problem was not occurred, another problem, short shot due to not enough driving force, was appeared More than 1,000 Pa of the inlet pressure, injected resin was rapidly leaked through the micro gap at the cavity edge. Finally, we obtained optimal inlet pressure around 600 ~ 1,000 Pa. At this region, injected resin fully filled the cavity without micro leakage behavior. Based on the present study, further comparative investigations with experimental photo RIM should be performed to find optimal processing conditions for produce ultra thin LGPs.

Estimation of the Separate Primary and Secondary Leakage Inductances of a Y-Δ Transformer Using Least Squares Method

  • Kang, Yong-Cheol;Lee, Byung-Eun;Hwang, Tae-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.538-544
    • /
    • 2010
  • This paper proposes an estimation algorithm for the separate primary and secondary leakage inductances of a three phase $Y-\Delta$ transformer using least squares method. The voltage equations from the primary and secondary windings are combined into a differential equation to estimate the separate primary and secondary leakage inductances in order to use the line current of the delta winding. Separate primary and secondary leakage inductances are obtained by applying least squares method to the differential equation. The performance of the proposed algorithm is validated under transient states, such as magnetic inrush and overexcitation, as well as in the steady state with various cut-off frequencies of low-pass filter. The proposed technique can accurately generate separate leakage inductances both in the steady and transient states.

Leakage Flux Distribution in the Simulated Environment

  • Kim, Chung-Hyeok;Kim, Tag-Yong;Oh, Yong-Cheul
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.401-405
    • /
    • 2012
  • Current research about voltage leakage involves investigation of the effects of leaked voltage and current on humans through simulated environments and dummies. Electrocution results from leaked current when electricity flows through the body as a result of potential difference. Research that analyzes actual electrocution is insufficient because of the danger from leaked voltage present in the leakage area. This thesis analyzes magnetic flux density from current around a leak to investigate the distribution of current. The authors used a simulated environment to investigate electrocution accidents that frequently occur during floods through leakage along metal surfaces, and evaluated the distribution of leaked magnetic flux.

Suppression of Leakage Current and Distortion in Variable Capacitance Devices and their Application to AC Power Regulators

  • Katsuki, Akihiko;Oki, Takuya
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.66-73
    • /
    • 2016
  • The quantity of alternating current (AC) leakage and the value of distortion factor in capacitor currents are discussed with regard to a new power component called variable capacitance device (VCD). This component has terminals for controlling its capacitance. Nonlinear dielectric characteristics are utilized in this device to vary the capacitance. When VCD operates in an AC circuit, the AC leakage from this device through direct current (DC) control voltage source increases according to the conditions of DC control voltage and so on. To solve this problem, we propose techniques for suppressing AC leakage. Although VCD has strong nonlinear characteristics, the current through the capacitor is not distorted significantly. The relations between AC leakage and the distortion in current waveforms are investigated. An application example for an AC power regulator is also introduced to evaluate the distortion in waveforms.

환경조건변화에 대한 실리콘애자의 누설전류 파형분석 (Waveform analysis of leakage current on silicon insulator for various environment condition variation)

  • 박재준
    • 정보학연구
    • /
    • 제7권2호
    • /
    • pp.69-76
    • /
    • 2004
  • 본 논문은 여러 가지 환경조건하(염무, 안개, 비)에서 오손된 실키콘애자의 누설전류파형과 파형의 스펙트럼 분석 결과를 나타내었다. 200ms동안 누설전류의 크기가 더욱 커지면 커질수록, 60Hz에서의 스펙트럼의 크기도 커짐을 알 수 있었다. 만일 오손된 애자들이 고밀도의 염무에 접촉되면 낮은 스펙트럼을 갖은 누설전류파형이 계측되었고, 간헐적으로 높은 파형이 계측되었다. 누설전류자료 분석의 경우, 전기적인 활동은 염무 측정시 애자표면에 누적된 오손물질로 인한 일시적인 아크거동으로 특성지어진다. 이것은 애자표면을 따라 흐르는 누설전류에 대한 경로를 제공하게 된 것이다. 그것은 특별한 애자의 퍼포먼스 측정을 평가하기위하여 오손누적의 지표를 갖은 것으로서 중요한 것이다. 만일 표면 저항의 떨어짐이 크게 되면, 그때의 누설전류는 전력품질이 저하시킨 섬락을 중단시키는 공급된 전류이 점차로 증가되어진다.

  • PDF