• 제목/요약/키워드: Technology leakage

검색결과 1,721건 처리시간 0.026초

Incidentally detected abnormal finding of femoral bone density image due to treatment of postoperative lymphatic leakage

  • Han-Kyung Seo;Do-Cheol Choi;Jae-Yung Jeong;Cheol-Min Shim;Yung-Hwan Jeong
    • 핵의학기술
    • /
    • 제28권1호
    • /
    • pp.13-17
    • /
    • 2024
  • Bone Mineral Densitometry (BMD) values is determined numerically with T or Z-score while the image is not considered in the interpretation. Abnormal finding was observed in the left femoral bone density image of a 64-year-old female patient who underwent a left kidney transplantation. This was due to the ethiodized oil used for embolization in the treatment of lymphatic leakage. Radiologic technologists should not only monitor changes of BMD values, but keep in mind to assess the changes in the image to provide accurate information to the patient.

공동주택 지하공간 누수 예방 기술 정책 수립을 위한 소비자 인식 분석 연구 (Consumer Awareness Analysis of Residential Building Underground Structure Leakage Prevention Measurements)

  • 한윤정;오규환;김수련;김병일;오상근
    • 한국건설순환자원학회논문집
    • /
    • 제4권4호
    • /
    • pp.379-387
    • /
    • 2016
  • 본 연구에서는 지하부위의 누수 예방 기술 정책 수립을 위한 방수 성능 분석 연구에 대하여 설문조사를 실시하고 이를 분석하였다. 설문 분석 결과, 현재 공동주택 지하공간에 대한 누수는 심각하며, 응답자 대부분도 이를 심각하게 인식하고 있다. 환경을 고려하지 않은 누수설계 및 누수예방 설계의 부재, 환경에 적합하지 않은 시공 시스템의 활용이 누수문제의 주요 원인이라 판단되었으며, 이를 개선하기 위하여 지하부위 외방수공법의 도입을 의무화하고, 설계시 공동주택 지하부위에 적용할 수 있는 표준 방수 기술 및 공법을 수립해야 될 것이며, 지하 시공환경을 고려한 방수 시공방법의 개발의 필요성이 강조되었다. 따라서 상기의 상황을 미루어 볼 때 법-제도에 의해 명시된 방수설계, 재료 및 공법, 유지관리 등을 방수시공의 전반적인 상황 컨트롤할 수 있는 가이드라인의 제시는 필수요소로 부각되었다.

찬공기 흐름을 고려한 LPG 누출 및 증기운에 의한 피해 영향 범위 분석 (Analysis of the Damaged Range Caused by LPG Leakage and Vapor Clouds Considering the Cold Air Flow)

  • 구윤정;송봉근;이원희;송병훈;신준호
    • 한국가스학회지
    • /
    • 제26권4호
    • /
    • pp.27-35
    • /
    • 2022
  • LPG는 공기보다 무거워 지표면으로 가라앉는 특징이 있으며, 주변 공기가 체류하는 경우 증기운을 형성하기 쉬워 가스 누출로 인한 피해가 가중될 우려가 있다. 그러므로 증기운 형성에 따른 주변 지역의 영향 범위분석을 통해 피해를 예방할 필요가 있다. 본 연구에서는 LPG 공급 관리소가 설치된 제주 하가리 일대를 대상으로 토지이용 현황과 지형적 특성으로 생성되는 야간 시간대의 찬공기 흐름과 그에 따른 LPG 누출 특성을 고려하여 주변 지역으로의 피해 영향 범위를 분석하였다. KLAM_21을 활용하여 찬공기 흐름을 분석한 결과, 지형 영향으로 인해 남동쪽에서 약 2 m/s의 찬공기가 유입되었다. LPG 누출 특성은 ALOHA를 이용하였으며 찬공기 흐름을 고려하여 분석하였다. 풍속 2 m/s 조건에서 누출공 크기가 10 cm일 때 LEL 60 %(12,600 ppm)에 해당하는 범위는 61 m로 나타났으며 LPG 누출 시 증기운에 의한 화재 등의 사고가 발생하는 경우 누출원으로부터 50 m 부근에 위치한 인근 주거지에 피해가 미칠 것으로 예상되므로 사고 예방을 위한 대안책이 요구된다. 해당 연구결과는 LPG 누출로 인한 사고 발생 시 예방책을 마련하는데 기초 자료로 활용될 수 있으며 FLACS와 같은 CFD 모델링을 통해 비교적 좁은 영역에서의 LPG 누출 형상 및 증기운으로 인한 피해 영향 범위를 확인할 필요가 있다.

사판식 액시얼 피스톤 펌프의 가변용량 시스템의 특성에 관한 연구 (A Study on Characteristics of a Compensator System for Swash Plate Type Axial Piston Pump)

  • 김신;오석형;정재연
    • Tribology and Lubricants
    • /
    • 제14권4호
    • /
    • pp.15-22
    • /
    • 1998
  • Recently, the importance of variable displacement piston pump is increasing in industrial world. Especially, most consumers require various range of pressures and flow rates. Pressure compensator is a system controlling flow rate in piston pump at low cost and, therefore, satisfies the need of consumers. However, the system has serious problems, such as response and leakage. The response and leakage are affected by clearance between actuator piston and cylinder, roughness of surface, and spool overlap. In this paper, these effects are investigated experimentally, and optimal clearance and chamfer is obtained. While diameter of cylinder is fixed and diameter of actuator piston is changed in this experiment, response and leakage are measured. Also parameters such as roughness and processing accuracy are changed for piston of fixed clearance. Experimental setup modelled into several parts of actuator piston, cylinder, spool, and swash plate. Input pressure is changed by function generator and proportional valve. The result of this experiment shows that leakage increases very much in proportion to the increase of clearance, and especially leakage occurs enormously when clearance is more than 0.002. The response is not good because as clearance increases leakage increases and as clearance decreases viscous damping effect increases. Accordingly, it is found out that optimal clearance range exists for tile response, within about 0.0012∼0.0014, at this time. Futhermore, the better roughness and geometrical accuracy of actuator piston are, the smaller are leakage and friction. The paper informs that response and leakage are influenced by and geometrical accuracy of actuator piston, roughness of surface, and the clearance between actuator piston and cylinder, and that optimal design of actuator piston in the pressure compensator is possible.

군사기밀 유출 사례 분석을 통한 군 내부정보 유출 방지 방안 : 내부자 행위 중심으로 (Measures to Prevent the Leakage of Military Internal Information through the Analysis of Military Secret Leakage Cases: Focusing on Insider Behaviors)

  • 엄정호;김남욱
    • 융합보안논문지
    • /
    • 제20권1호
    • /
    • pp.85-92
    • /
    • 2020
  • 최근에 발생한 군사기밀 유출 사례 중에는 정보통신망을 이용한 내부정보 유출은 드물다. 그 이유는 군 업무 특성상 국방정보통신망은 자료 전송용 인터넷과 내부 업무용 인트라넷으로 구성되어 있는데 물리적으로 분리되어 있고, 인터넷망을 통해서 자료를 송·수신할 때는 까다로운 절차를 거치게 때문이다. 최근 군사기밀 유출 사례를 분석한 결과 대부분의 유출 경로는 비밀을 복사하여 넘겨주거나 스마트폰으로 촬영하여 전송하거나 기밀 내용을 기억한 후에 발설한 것이다. 그래서 정보통신망을 대상으로 한 군사기밀 유출 차단 또는 탐지하는 기술은 효과적이지 못하다. 본 연구에서는 유출 대상인 군사기밀이 아닌 유출 주체자인 내부자 행위에 중점을 두고 정보유출 방지 방안을 제안하고자 한다. 첫 번째는 군사기밀을 유출하는 행위를 차단하는 예방 대책이고 두 번째는 군사기밀 파일에 의심스러운 접근행위를 차단하는 방안이며, 마지막으로 내부자의 정보유출 행위를 탐지하는 방안이다.

Feasibility study of β-ray detection system for small leakage from reactor coolant system

  • Jang, Jaeyeong;Jeong, Jae Young;Park, Junesic;Cho, Young-Sik;Pak, Kihong;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2748-2754
    • /
    • 2022
  • Because existing reactant coolant system (RCS) leakage detection mechanisms are insensitive to small leaks, a real-time, direct detection system with a detection threshold below 0.5 gpm·hr-1 was studied. A beta-ray detection system using a silicon detector with good energy resolution for beta rays and a low gamma-ray response was proposed. The detection performance in the leakage condition was evaluated through experiments and simulations. The concentration of 16N in the coolant corresponding to a coolant leakage of 0.5 gpm was calculated using the analytic method and ORIGEN-ARP. Based on the concentration of 16N and the measurement of the silicon detector with 90Sr/90Y, the beta-ray count rate was estimated using MCNPX. To evaluate the effect of gamma rays inside the containment building, the signal-to-noise ratio (SNR) was calculated. To evaluate the count rate ratio, the radiation field inside the containment building was simulated using MCNPX, and response evaluation experiments were performed using beta and gamma rays on the silicon detector. The expected beta-ray count rate at 0.5 gpm leakage was 7.26 × 105 counts/sec, and the signal-to-background count rate ratio exceeded 88 for a transport time of 10 s, demonstrating its suitability for operation inside a reactor containment building.

Excimer laser로 재결정화한 LDD구조의 poly-Si TFT 제작 (Fabrication of the LDD Structure poly-Si TFT with Excimer Laser Recrystallization Process)

  • 정준호;박용해
    • 전자공학회논문지A
    • /
    • 제32A권2호
    • /
    • pp.324-331
    • /
    • 1995
  • The leakage current characteristics of the low temperature processed LDD structure poly-Si TFT is analyzed. The excimer laser technology was applied to the recrystallization process of poly-Si film and the maximum processing temperature was retained under 600.deg.C. From the fabricated LDD space 0.3.mu.m to 3$\mu$m, the best on/off current ration could be obtained with the 1.3$\mu$m LDD space. And the threshold voltage did not increase more than 4V over 0.8$\mu$m LDD space. The characteristics of leakage current was compared to non-LDD structure TFT to analyze the mechanism of leakage current. Consequently, it could be concluded that the leakage current is strongly affected by the trap states as well as high electric field between gate and drain.

  • PDF

Numerical Study on Flow Characteristics at Blade Passage and Tip Clearance in a Linear Cascade of High Performance Turbine Blade

  • Myong, Hyon-Kook;Yang, Seung-Yong
    • Journal of Mechanical Science and Technology
    • /
    • 제17권4호
    • /
    • pp.606-616
    • /
    • 2003
  • A numerical analysis has been conducted in order to simulate the characteristics of complex flow through linear cascades of high performance turbine blade with/without tip clearance by using a pressure-correction based, generalized 3D incompressible Wavier-Stokes CFD code. The development and generation of horseshoe vortex, passage vortex, leakage vortex, tip vortex within tip clearance, etc. are clearly identified through the present simulation which uses the RNG k-$\varepsilon$ turbulent model with wall function method and a second-order linear upwind scheme for convective terms. The present simulation results are consistent with the generally known tendency that occurs in the blade passage and tip clearance. A 3D model for secondary and leakage flows through turbine cascades with/without tip clearance is also suggested from the present simulation results, including the effects of tip clearance height.

마이크로 용적형 수차의 측면누설손실이 성능에 미치는 영향 (Influence of Side Leakage Loss on the Performance of a Micro Positive Displacement Hydraulic Turbine)

  • 최영도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.291-295
    • /
    • 2006
  • Recently, greenhouse effect by $CO_2$ gas emitted by use of fossil fuel causes earth environmental problem. As a countermeasure of the global warming. micro hydropower under 100kW becomes the focus of attention for its clean and renewable energy sources. Newly developed micro positive displacement hydraulic turbine shows high efficiency and good applicability for the micro hydropoewer. The purpose of this study is to clarify the influence of leakage loss and effective head on the performance of the positive displacement hydraulic turbine for the further improvement of the turbine performance. The results show that the turbine. with a smaller side clearance. has much higher efficiency than that with bigger side clearance and it can sustain the high efficiency under the wider range of operation conditions. The turbine torque is proportional to the effective head and independent of the flow rate. The leakage is also dependent on the effective head but nearly independent of the flow rate.

Detection of Leakage Point via Frequency Analysis of a Pipeline Flow

  • Kim, Sanghyun;Wansuk Yoo;Injoon Kang
    • Journal of Mechanical Science and Technology
    • /
    • 제15권2호
    • /
    • pp.232-238
    • /
    • 2001
  • Fast Fourier Transformation is employed to convert the head variation of a pipeline in the time domain to the amplitude of the frequency domain. Applying method of characteristics to a pipeline provides a significant frequency range for a surge introduced from the valve modulation. Inverse Fast Fourier Transformation and a Finite Impulse Response Filter can be used to remove any possible noise existing from the significant frequency range of an unsteady condition. A filtered signal shows higher potential for the inverse calculation of leakage detection than the noise-added signal does. The respective performances of Inverse Fast Fourier Transformation and a Finite Impulse Response Filter are compared in terms of leakage detection capability. Characteristics of the frequency range for multiple leakages were investigated to validate the effectiveness of the noise control method in the frequency domain.

  • PDF