• Title/Summary/Keyword: Technology Acquisition

Search Result 1,926, Processing Time 0.033 seconds

FRONT-END TELEMETRY DATA ACQUISITION UNIT FOR KSLV-I UPPER STAGE

  • Jung Hae-Seung;Kim Joonyun;Lee Jae-Deuk
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.337-340
    • /
    • 2004
  • Upper stage telemetry system of KSLV- I (Korea Space Launch Vehicle I) is composed of MDU (Master Data Unit), RDU (Remote Data Unit), SRU (Shock Recorder Unit) and Transmitter. RDU is the front-end telemetry data acquisition unit which gathers analog/discrete signals from various sensors and other units, and transmits the processed data to MDU via MIL-STD-I553B data bus. In order to acquire useful data from analog signal, signal conditioning circuits, such as anti-aliasing or amplifying, should be implemented. For this purpose, SCM (Signal Conditioning Module) had been developed. This paper describes hardware structure of SCM and analog signal conditioning circuits for various sensors. Also, sampling time scheme for different sampling rates were designed and tested.

  • PDF

A Study on the Analysis of the Cost-Effectiveness for the New Generation Multiple Launcher Rocket System Using AHP & Parametric Estimating (AHP & 모수추정법을 이용한 차기 다련장로켓의 비용대 효과분석)

  • Cho, Ki-Hong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.84-90
    • /
    • 2010
  • Korean army currently considers the development of the new generation MLRS(Multiple Launcher Rocket System) as a new alternative, which responses on the renovation of the artillery and future battlefield environment. This study suggests that it presents cost-effectiveness of MLRS based on the Analytic Hierarchy Process and Parametric Estimating(PRICE H). According to this study, the cost-effectiveness of new generation MLRS presented that alternative A is 2.30 times and alternative B is 1.70 times, which are better than currently operating M270A1. Therefore, The best acquisition is alternative A that launcher is carried on currently operating 10ton standard truck but final acquisition alternative should be politically decided to consider viability of operator, performance and the latest of equipment.

Non-contact surface wave testing of pavements: comparing a rolling microphone array with accelerometer measurements

  • Bjurstrom, Henrik;Ryden, Nils;Birgisson, Bjorn
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.1-15
    • /
    • 2016
  • Rayleigh wave velocity along a straight survey line on a concrete plate is measured in order to compare different non-destructive data acquisition techniques. Results from a rolling non-contact data acquisition system using air-coupled microphones are compared to conventional stationary accelerometer results. The results show a good match between the two acquisition techniques. Rolling measurements were found to provide a fast and reliable alternative to stationary system for stiffness determination. However, the non-contact approach is shown to be sensitive to unevenness of the measured surface. Measures to overcome this disadvantage are discussed and demonstrated using both forward and reverse rolling measurements.

An approach of the ACTD in Defense Acquisition Programs (국방획득사업에서의 ACTD기법 적용)

  • Gwon, Yong-Su;Song, Chang-Gyu
    • 시스템엔지니어링워크숍
    • /
    • s.4
    • /
    • pp.5-10
    • /
    • 2004
  • ACTD(Advanced Concept Technology Demonstrations) exploit mature technologies to solve important military problems. A declining budget, significant changes in threats, and an accelerated pace of technology development have challenged our ability to adequately respond to rapidly evolving military needs. This work descibes ACTD processes, management, and ACTD programs case. It is presesyed a defense acquisition program applied ACTD.A scheme of the defense asquisition program using ACTD met military needs and technology readiness level is described.

  • PDF

미 국방성의 획득관련 조직과 인원 관리/교육 현황(2)-Acquisition Reform 및 미 공군을 중점으로

  • Lee, Jae-Yong
    • Defense and Technology
    • /
    • no.2 s.276
    • /
    • pp.40-49
    • /
    • 2002
  • 미국의 연구, 개발 및 획득 전략도 Joint Vision 2020을 달성하는 것에 목표를 두고 발전되고 있다. 현재 미국은 품질이 향상된 무기체계를 보다 빠르고 저렴하게 획득할 수 있도록 기존의 획득체계 및 인원을 효율적으로 수정/개편하는 Acquisition Reform을 강력하게 추진하고 있다. 이 글은 Acquisition Reform 및 미 공군을 중심으로 미국의 획득관련 조직 및 관련 요원에 대한 관리/교육 및 훈련에 대해 검토하여 향후 우리군의 획득관련 조직 및 인원관리 발전 방향 검토시 유익한 참고자료로 활용되었으면 하는 취지에 작성되었다.

  • PDF

미 국방성의 획득관련 조직과 인원 관리/교육 현황-Acquisition Reform 및 미 공군을 중점으로

  • Lee, Jae-Yong
    • Defense and Technology
    • /
    • no.1 s.275
    • /
    • pp.50-57
    • /
    • 2002
  • 미국의 연구, 개발 및 획득 전략도 Joint Vision 2020을 달성하는 것에 목표를 두고 발전되고 있다. 현재 미국은 품질이 향상된 무기체계를 보다 빠르고 저렴하게 획득할 수 있도록 기존의 획득체계 및 인원을 효율적으로 수정/개편하는 Acquisition Reform을 강력하게 추진하고 있다. 이 글은 Acquisition Reform 및 미 공군을 중심으로 미국의 획득관련 조직 및 관련 요원에 대한 관리/교육 및 훈련에 대해 검토하여 향후 우리군의 획득관련 조직 및 인원관리 발전 방향 검토시 유익한 참고자료로 활용되었으면 하는 취지에서 작성되었다.

  • PDF

Cost-Efficient and Automatic Large Volume Data Acquisition Method for On-Chip Random Process Variation Measurement

  • Lee, Sooeun;Han, Seungho;Lee, Ikho;Sim, Jae-Yoon;Park, Hong-June;Kim, Byungsub
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.184-193
    • /
    • 2015
  • This paper proposes a cost-efficient and automatic method for large data acquisition from a test chip without expensive equipment to characterize random process variation in an integrated circuit. Our method requires only a test chip, a personal computer, a cheap digital-to-analog converter, a controller and multimeters, and thus large volume measurement can be performed on an office desk at low cost. To demonstrate the proposed method, we designed a test chip with a current model logic driver and an array of 128 current mirrors that mimic the random process variation of the driver's tail current mirror. Using our method, we characterized the random process variation of the driver's voltage due to the random process variation on the driver's tail current mirror from large volume measurement data. The statistical characteristics of the driver's output voltage calculated from the measured data are compared with Monte Carlo simulation. The difference between the measured and the simulated averages and standard deviations are less than 20% showing that we can easily characterize the random process variation at low cost by using our cost-efficient automatic large data acquisition method.

Wireless Triggering Pulse Generation for Digital X-ray Imaging System (디지털 x-ray 영상시스템을 위한 무선 트리거 발생기)

  • Ko, Dae-Sik;Lee, Jae-Cheol;Lee, Joo-Shin
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.2
    • /
    • pp.163-169
    • /
    • 2007
  • In this paper, we propose a method of trigger pulse generation to capture the image on time by making a synchronization between the x-ray generator and digital x-ray image acquisition system. we designed a wireless trigger pulse generation circuit to make a synchronization between x-ray generator and digital image acquisition system and analysis its performance. When it starts to detect a certain level of x-ray radiation or above from the air, this method starts to generate a ACQ_START signal to indicate the timing for image acquisition starting from digital image acquisition system. Hence, when it starts to detect under certain level of x-ray signal from the air, this method starts to generate a ACC_END signal to indicate the timing for image acquisition stop from digital image acquisition system. Image acquisition is activated only this time between ACQ_START and ACQ_END signal. By doing this wireless detecting of x-ray signal from remote, we can get more accurate timing for capturing the x-ray image and any type of x-ray generator can be connected to digital image acquisition system, regards of wired protocol. This makes easy installation. We could get 3.5 line pair / mm resolution at 20 mAs of x-ray level with resolution chart. This is same or better image comparing to conventional wired result.

  • PDF

Design and Implementation of Seismic Data Acquisition System using MEMS Accelerometer (MEMS형 가속도 센서를 이용한 지진 데이터 취득 시스템의 설계 및 구현)

  • Choi, Hun;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.851-858
    • /
    • 2012
  • In this paper, we design a seismic data acquisition system(SDAS) and implement it. This system is essential for development of a noble local earthquake disaster preventing system in population center. In the system, we choose a proper MEMS-type triaxial accelerometer as a sensor, and FPGA and ARM processor are used for implementing the system. In the SDAS, each module is realized by Verilog HDL and C Language. We carry out the ModelSim simulation to verify the performances of important modules. The simulation results show that the FPGA-based data acquisition module can guarantee an accurate time-synchronization for the measured data from each axis sensor. Moreover, the FPGA-ARM based embedded technology in system hardware design can reduce the system cost by the integration of data logger, communication sever, and facility control system. To evaluate the data acquisition performance of the SDAS, we perform experiments for real seismic signals with the exciter. Performances comparison between the acquired data of the SDAS and the reference sensor shows that the data acquisition performance of the SDAS is valid.

A Study on the Optimum Design of Charge Pump PLL with Dual Phase Frequency Detectors (두 개의 Frequency Detector를 가지고 있는 Charge Pump PLL 의 최적설계에 관한 연구)

  • Woo, Young-Shin;Jang, Young-Min;Sung, Man-Young
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.10
    • /
    • pp.479-485
    • /
    • 2001
  • In this paper, we introduce a charge pump phase-locked loop (PLL) architecture which employs a precharge phase frequency detector (PFD) and a sequential PFD to achieve a high frequency operation and a fast acquisition. Operation frequency is increased by using the precharge PFD when the phase difference is within $-{\pi}{\sim}{\pi}$ and acquisition time is shortened by using the sequential PFD and the increased charge pump current when the phase difference is larger than ${\pm}{\pi}$. So error detection range of the proposed PLL structure is not limited to $-{\pi}{\sim}{\pi}$ and a high frequency operation and a higher speed lock-up time can be achieved. The proposed PLL was designed using 1.5 ${\mu}m$ CMOS technology with 5V supply voltage to verify the lock in process. The proposed PLL shows successful acquisition for 200 MHz input frequency. On the other hand, the conventional PLL with the sequential PFD cannot operate at up to 160MHz. Moreover, the lock-up time is drastically reduced from 7.0 ${\mu}s\;to\;2.0\;{\mu}s$ only if the loop bandwidth to input frequency ratio is regulated by the divide-by-4 counter during the acquisition process. By virtue of this dual PFDs, the proposed PLL structure can improve the trade-off between acquisition behavior and locked behavior.

  • PDF