• Title/Summary/Keyword: Techniqu

Search Result 6, Processing Time 0.02 seconds

An Area Look-Up-Table based Controller for Improving Performance of Luminance on Lighting Passive Matrix Organic Light Emitting Diodes Panels

  • Juan, Chang-Jung;Tsai, Ming-Jong;Liu, Chia-Lin;Mo, Chi-Neng
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1487-1490
    • /
    • 2005
  • This study proposes a controller with the techniqu e of voltage -compensated driver for producing grayscaled pictures on passive matrix organic light emitting diodes (PMOLEDs) panels; especially, the controller overcomes the problem of luminance nonuniformity on displaying pictures. Because the controller is a voltage type driver, the output impedance of the driver is much less than that of the current-type driver. Hence, the controller provides a better electron-optical response than those of traditional current drivers. An area compensated look-up table (ACLUT) is designed in data feeding paths for removing luminance non-uniformity; thus, the proposed controller provides nearly 95% luminance uniformity.

  • PDF

Regional Variations in Spectra of (25143) Itokawa taken with Hayabusa/AMICA

  • Jin, Sunho;Ishiguro, Masateru
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.73.2-73.2
    • /
    • 2018
  • The Hayabusa remote-sensing images of near-Earth asteroid (25143) Itokawa exhibited large diversity in spectral properties. The evidence suggests a various degrees of space weathering on the surface. It is known that the space weathering changes the spectra of S-type asteroids redder and reduces the depths of absorption around $1{\mu}m$. It is therefore possible to determine the surface ages through the investigation of the degree of space weathering. It is, however, reported that the scattered light components severely degrade the Asteroid Multiband Imaging Camera (AMICA) images, especially at the wavelengths > $0.86{\mu}m$. Our team came up with a technique for subtracting the scattered light components (Ishiguro 2014). Here, we upgraded the techniqu e by applying simplex algorism to correct the artifacts for all AMICA bands. This new technique enables to apply for the longest channel (i.e., zs-band at $1.01{\mu}m$) images, which was not studied so far. With the AMICA all bands data, we estimated the surface ages at the different location to be 0.6-2 Myr. Based on this data together with the geological information (e.g. gravitational potentials and local). we will discuss about the evolution of surface materials on the asteroid.

  • PDF

Coil-Protected Technique for Liquid Embolization in Neurovascular Malformations

  • Keun Young Park;Jin Woo Kim;Byung Moon Kim;Dong Joon Kim;Joonho Chung;Chang Ki Jang;Jun-Hwee Kim
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1285-1292
    • /
    • 2019
  • Objective: To evaluate the safety and efficacy of the coil-protected technique for liquid embolization in neurovascular malformations. Materials and Methods: Twenty-two patients who underwent coil-protected liquid embolization for symptomatic cranial (n = 13) and spinal (n = 9) arteriovenous fistula (AVF) or arteriovenous malformations (AVMs) were identified. A total of 36 target feeder vessels were embolized with N-butyl cyanoacrylate and/or Onyx (Medtronic). This technique was used to promote delivery of a sufficient amount of liquid embolic agent into the target shunt or nidus in cases where tortuous feeding arteries preclude a microcatheter wedging techniqu and/or to prevent reflux of the liquid embolic agent in cases with a short safety margin. The procedure was considered technically successful if the target lesion was sufficiently filled with liquid embolic agent without unintentional reflux. Angiographic and clinical outcomes were retrospectively evaluated. Results: Technical success was achieved for all 36 target feeders. Post-embolization angiographies revealed complete occlusion in 16 patients and near-complete and partial occlusion in three patients each. There were no treatment-related complications. Of the six patients who showed near-complete or partial occlusion, five received additional treatments: two received stereotactic radiosurgery for cerebral AVM, two underwent surgical removal of cerebral AVM, and one underwent additional embolization by direct puncture for a mandibular AVM. Finally, all patients showed complete (n = 19) or near-complete (n = 3) occlusion of the target AVF or AVM on follow-up angiographies. The presenting neurological symptoms improved completely in 15 patients (68.2%) and partially in seven patients (31.8%). Conclusion: The coil-protected technique is a safe and effective method for liquid embolization, especially in patients with various neurovascular shunts or malformations who could not be successfully treated with conventional techniques.

A Study on MR Cholangiography using Breathing Hold Target Techniqu by Prospective Acquisition Correction and Respiration Trigger Gating (Non Breathe Hold Technique를 이용한 MR 담도계조영술에 대한 고찰 : Prospective Acquisition Correction(PACE)기법과 Respiration Trigger Gating(RTG) 기법의 비교)

  • Goo, Eun-Hee;Jeong, Hong-Ryang;Im, Cheong-Hwan;Kweon, Dae-Cheol;Jo, Jeong-Keun;Lee, Man-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • Recently, MR Cholangiography used mainly bu controlling of patient's breathing. There is breathing hold techniques to get images within shopt time and gating technique adjusted to respiration cycle for high resolution image. In this study, the aim of this experiment is to know on clinical usefulness compared with PACE and RTG thchniques. This study's period is from 2006 in November to 2007 in January. A total of 21 patients investigated at MAGNETOM Sonata 1.5T (SIEMENS Erlangen) with use of 12ch body coil. MR acquisition protocol used 3D turbo spin echo coronal sequence. Scan parameters applied to potimal setting in use as gating techniques, respectively. Analysis of consuming timing evaluated with rapidness. As analysis of quantity, the common bile duct, gall bladder measured in signal intensities, then these data were calculated by signal to noise ratio and contrast to noise ratio. Qualitative analysis, experienced 2radiologists and 3 RTs were evaluated into 3groups about artifact, accuracy of lesions, sharpness of the common bile duct or gall bladder. As a result of analysis, when compared to PACE, consuming time of the RTG took less than PACE, On both CNRs and SNRs, PACE technique was slightly high values than RTG(p<0.05). Qualitative analysis' results, discrimination of lesions in the common bile duct, gall bladder get a significance level in both RTG and PACE techniques but presence's artifact of breathing and pulsation highly demonstrate in PACE techniques. In conclusion, both PACE and RTG methods at MRCP provided prominently clinical information for the common bile duct, gall bladder. If machines have not limitation with performance, induction of breathing holding also will help getting diagnistic quality.

  • PDF

A Study on the Product Planning Model based on Word2Vec using On-offline Comment Analysis: Focused on the Noiseless Vertical Mouse User (온·오프라인 댓글 분석이 활용된 Word2Vec 기반 상품기획 모델연구: 버티컬 무소음마우스 사용자를 중심으로)

  • Ahn, Yeong-Hwi
    • Journal of Digital Convergence
    • /
    • v.19 no.10
    • /
    • pp.221-227
    • /
    • 2021
  • In this paper, we conducted word-to-word similarity analysis of standardized datasets collected through web crawling for 10,000 Vertical Noise Mouses using Word2Vec, and made 92 students of computer engineering use the products presented for 5 days, and conducted self-report questionnaire analysis. The questionnaire analysis was conducted by collecting the words in the form of a narrative form and presenting and selecting the top 50 words extracted from the word frequency analysis and the word similarity analysis. As a result of analyzing the similarity of e-commerce user's product review, pain (.985) and design (.963) were analyzed as the advantages of click keywords, and the disadvantages were vertical (.985) and adaptation (.948). In the descriptive frequency analysis, the most frequently selected items were Vertical (123) and Pain (118). Vertical (83) and Pain (75) were selected for the advantages of selecting the long/demerit similar words, and adaptation (89) and buttons (72) were selected for the disadvantages. Therefore, it is expected that decision makers and product planners of medium and small enterprises can be used as important data for decision making when the method applied in this study is reflected as a new product development process and a review strategy of existing products.

The Optimal Combination of Major Nutrients Computed by the Homés Systematic Variation Technique -III. Determination of the Optimal Combination of Σ Anion : Σ Cation and the Optimal Application Rate of Total Ions on the Various Grassland Soils (Homés방법(方法)에 의(依)한 다량요소(多量要素)의 적정(適正) 시비비율(施肥比率) 결정(決定)에 관한 연구 -III. 초지토양별(草地土壤別) 음(陰)이온 성분총량(成分總量) : 양(陽)이온 성분총량(成分總量) 적정(適正) 시비비율(施肥比率) 및 적정(適正) 총시비량(總施肥量))

  • Jung, Yeun-Kyu;Kim, Sang-Chul;Weinberger, P.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.15 no.3
    • /
    • pp.178-187
    • /
    • 1982
  • This pot experiment was undertaken to find out the optimum fertilization ratios of total anions to total cations, ${\Sigma}A/{\Sigma}C$, and the optimum application rates of total macro-nutrients in various soil conditions. Soil samples were collected from uncultivated mountains and hills where grassland development was under consideration. 1. The optimum application ratios of ${\Sigma}A/{\Sigma}C$ and the optimum application rates of total macro-nutrients for the high yields of mixed grass-clover sward in various grassland soils were computed by the Hom$\acute{e}$s systematic variation techniqu.e. 2. With respect to the optimum application ratios of ${\Sigma}A/{\Sigma}C$ in fertilization in a mixed grass-clover sward, the grass yield and botanical composition were distinctly proportional to ${\Sigma}A$ wheras the regume yield and botanical composition were proportional to ${\Sigma}C$. 3. The optimum fertilization rates of total macro-nutrients for the high legume yields were depended upon ${\Sigma}A/{\Sigma}C$ ratios. These optimum rates were in proportional to ${\Sigma}C$ ratios and were inversely proportional to ${\Sigma}A$ ratios. 4. The efficiencies of ${\Sigma}A$ and ${\Sigma}C$ in relation to the grass and grass plus legume yields were highest with the low ratios of each other and the low fertilization rates of total macronutrients. The ${\Sigma}A$ effieiency in the legume yield tended to be similar to that of ${\Sigma}A$ related to the grass yield noted above except Daegu soil. The ${\Sigma}C$ efficiency, however, was proportional to the ${\Sigma}C$ ratio, although that was varied with the fertilization rates of total macro-nutrients and with the kinds of soils. 5. The yield of mixed forages, yield component, and botanical composition in a mixed sward were greatly influenced by the ${\Sigma}A/{\Sigma}C$ ratios, the fertilization rates of total macronutrients, and the interactions of ratio and rate noted above. In addition, these effects were generally different and opposite according to grass and legume.

  • PDF