• Title/Summary/Keyword: Tc-99m MIBI SPECT

Search Result 90, Processing Time 0.022 seconds

Analysis of Polar Maps of Dipyridamole Stress/Rest $^{99m}Tc$-MIBI Myocardial SPECT in 14 Healthy Young Men (건강한 청년 남자 14 례에서 Dipyridamole 부하 $^{99m}Tc$-MIBI 심근 SPECT 극성지도의 분석)

  • Cho, Ihn-Ho;Sin, Dong-Gu;Lee, Hyoung-Woo;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.1
    • /
    • pp.146-152
    • /
    • 1994
  • We performed the same day dipyridamole stress/rest myocardial SPECT in 14 healthy young men, reconstructed the polar maps according to Cedars-Sinai method and quantitated the radioactivity of myocardial wall. We divided the whole myocardium to 9 sectors. The latero-anterior wall contains the highest count. The infero-septal wall contains the lowest count. There isn't any significant differences of radioactivity in each segment between stress and rest polar map. The hemodynamic parameters after dipyridamole injection in the subjects were significantly changed except systolic blood pressure : the heart rate was increased and diastolic blood pressure was decreased. Adverse effects were reported in 85.7%. We suggest that these data can be used to dectect perfusion defect in the coromary artery disease.

  • PDF

Prognostic Value of Normal Exercise $^{99m}Tc$-MIBI Myocardial Perfusion SPECT: Comparison with Exercise Electrocardiography and Coronary Angiography ($^{99m}Tc$-MIBI 운동부하 심근관류 SPECT에서 정상소견을 보인 환자의 예후: 운동부하 심전도와 관동맥 조영소견과의 비교)

  • Lee, Sang-Woo;Lee, Jae-Tae;Chun, Kyung-Ah;Kang, Do-Young;Kim, Dong-Hwan;Cho, Yong-Keun;Chae, Shung-Chull;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.199-206
    • /
    • 2000
  • Purpose: Myocardial perfusion scintigraphy is a useful technique to diagnose and to predict prognosis in patients with suspected or known coronary artery disease. The purpose of the present study is to evaluate the prognostic value of normal exercise $^{99m}Tc$-MIBI myocardial perfusion single photon emission computed tomography (SPECT) and to analyze results with regard to those of exercise electrocardiography or coronary angiography. Materials and Methods: We evaluated 301 patients (mean age $52{\pm}10$ years, 166 males and 135 females) with normal exercise $^{99m}Tc$-MIBI myocardial perfusion SPECT performed for suspected coronary artery disease. Subject were evaluated for cardiac events and followed for 8-55 months (mean $19{\pm}10$ months) after imaging. Results: During the follow-up period, there was no cardiac death but only one non-fatal myocardial infarction (event rate 0.21% per year). In addition, only one patient underwent coronary revascularization. There was no significant difference in cardiac event rate between patients with positive (n=27) and negative (n=235) exercise electrocardiography (p:NS). There was no cardiac event in 17 patients who underwent coronary angiography (4 patients with >50% luminal narrowing, 2 patients with vasospasm and 11 patients with no significant lesion). Conclusion: Patients with normal exercise $^{99m}Tc$-MIBI myocardial perfusion SPECT has a very low risk for cardiac events regardless of exercise electrocardiographic and coronary angiographic findings.

  • PDF

Comparison of Ga-67, Tl-201 and Tc-99m MIBI Imaging in Lymphoma Patients (림프종 환자에서의 갈륨, Tl-201 그리고 Tc-99m MIBI 섭취의 비교)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Kyu-Chang;Lee, Kyung-Hee;Lee, Hyung-Woo;Hyun, Myung-Soo;Lee, Jae-Tae;Lee, Kyu-Bo
    • Journal of Yeungnam Medical Science
    • /
    • v.19 no.2
    • /
    • pp.107-115
    • /
    • 2002
  • Purpose: Ga-67 scintigraphy has been used for the evaluation of tumors, especially lymphoma. Recently, Tl-201 and Tc-99m MIBI were also used to tumor imaging. Tl-201 and Tc-99m MIBI had better physiologic characteristics than Ga-67, so we studied 32 biopsy proven lymphoma patients (male 24, female 8, mean age 46 years) with Ga-67, Tl-201 or Tc-99m MIBI and compared the scan findings. Materials and Methods: Twenty-three of 32 patients were injected 74-111 MBq (2-3 mCi) of Tl-201, before chemotherapy and imaged with dual-headed SPECT (Prism 2000, Picker, USA) at 30 minutes after injection. Delayed images were obtained after 3 hr in 8 patients. Twenty seven of 32 patients were injected 740 MBq (20 mCi) of Tc-99m MIBI and imaged at 30 minutes after injection. 111-185 MBq (3-5 mCi) of Ga-67 was injected in 12 patients and imaged at 48 and 72 hours after injection. Twenty eight patients were diagnosed as non-Hodgkin's lymphoma and others were Hodgkin's lymphoma. Results: Twenty patients were positive on Tl-201 scan and 3 patients showed negative findings. One of these 3 patients, Tc-99m MIBI and Ga-67 scan were positive. Twenty two patients were positive on Tc-99m MIBI scan and 5 patients showed negative findings. One of these 5 patients, Tl-201 was positive and 2 were positive on Ga-67 scan. Ten of 12 patients showed positive findings on Ga-67 scan. The sensitivity of these agents were 83.3%, 87.0% and 81.5% for Ga-67, Tl-201 and Tc-99m MIBI, respectively. The sensitivity was highest in Tl-201 scan, but there were no significant differences among three tests. In this study, there was no significant difference of uptake ratios between early and delayed images of Tl-201. Conclusion: Scintigraphy with Tl-201 and Tc-99m MIBI in lymphoma patients have similar sensitivity with Ga-67.

  • PDF

Comparison between $180^{\circ}$ and $360^{\circ}$ Data Collection in $^{99m}Tc-MIBI$ Myocardial SPECT ($^{99m}Tc-MIBI$ 심근 SPECT에서 180도와 360도 데이터 집적의 비교)

  • Kang, Keon-Wook;Lee, Dong-Soo;Kwark, Cheol-Eun;Hyun, In-Young;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.478-483
    • /
    • 1995
  • We compared the influences of reconstruction methods using $180^{\circ}$ or $360^{\circ}$ data upon contrasts and discriminating capability and diagnostic accuracy in $^{99m}Tc-MIBI$ stress/rest myocardial SPECT. We reviewed SPECT images reconstructed only with $180^{\circ}$ projection data or with $360^{\circ}$ data in 18 patients and in 11 normal subjects. To compare counts of surface structures and deep structures, we measured ape# posterior wall ratios in 11 normal subjects. To compare the contrasts of images, we measured apex/ventricle ratios. To compare contrasts between normal and diseased myocardial segments, we measured count ratios of defect and normal segments in 4 patients who had single coronary artery diseases. To compare diagnostic accuracy, we scored SPECT images made with $180^{\circ}$ and $360^{\circ}$ data segmentally. Sensitivity and specificity for the diagnosis of coronary artery disease and for the revelation of diseased arteries with both $180^{\circ}$ and $360^{\circ}$ SPECT images. If involved coronary arteries had more narrowing than 50% In coronary angiogram, we considered them as diseased arteries Apex/posterior wall ratios were not different significantly in normal subjects. Apex/ ventricle ratios in normal subjects were different significantly between $180^{\circ}$ and $360^{\circ}$ SPECT images. Defect/normal ratios were different significantly between $180^{\circ}$ and $360^{\circ}$ SPECT images in single vessel disease patients. The overall diagnostic accurracy was the same between $180^{\circ}$ and $360^{\circ}$ data collection. Sensitivity was 94% and specificity was 91% for both types of data collection in this sample population. Sensitivity and specificity of each coronary artery territory were not significantly different between the images made with $180^{\circ}$ and $360^{\circ}$ data. The images made with $180^{\circ}$ data had better contrast between ventricle and myocardium and between hypoperfused and normal myocardium, though no difference was found between the ratios of the myocardial counts of surface and deep structures. However, diagnostic sensitivities of diseased artery territories were not different significantly and so were overall diagnostic accuracy between both methods of making images with $180^{\circ}$ and $360^{\circ}$ data.

  • PDF

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

A Quantitative Method for the Assessment of Myocardial Function using the Polar Analysis of Tc-99m-MIBI Myocardial SPECT (Tc-99m-MIBI 심근 SPECT 극성지도 분석에 의한 심근 기능의 정량적 평가)

  • Kwark, Cheol-Eun;Lee, Dong-Soo;Yeo, Jung-Suk;Lee, Kyung-Han;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.172-176
    • /
    • 1994
  • As the Tc-99m-MIBI myocardial SPECT demonstrated wide application in the diagnosis of myocardial function, the quantitative and severity-dependent information is currently re quired. In this study, we proposed a computerized method for scoring the fixed defects in terms of extent-weighted severity and for identifying the reversibility in ischemic regions. At the first stage of this method, the transverse slices were reconstructed with 0.4 Nyquist freq. and order 5 Butterworth filter. From the oblique/sagittal slices, maximal count per pixel circumferential profiles were extracted for each sector, and then stress/redist. polar maps were normalized and plotted. For reversibility, the stress polar map was subtracted from the de-layed image and positive-valued pixels were categorized into three grades. The extent-weight-ed severity scores were calculated using the assigned grades and their number of pixels. This procedure was done automatically and the reversibility and severity scores were produced for each of the coronary territories (LAD, RCA, LCX) or any combination of these. Clinical ap-plication has shown that the changes In reversibility scores after PTCA were correlated linearly with the pre PTCA scores(r>0.8) in postinfarct cases as well as in angina, and severity scores of persistent defects in stress/rest SPECT study matched to the regional ejection fraction and visual analysis of regional wall motion of gated blood pool scan(r>0.6). We conclude that the computerized severity scoring method for the analysis of myocardial SPECT could be useful in the assessment of the myocardial ischemia and fixed defect.

  • PDF

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

The Usefulness of Myocardial SPECT for the Preoperative Cardiac Risk Evaluation in Noncardiac Surgery (비심장 수술 환자에서 수술 전후 심장사건의 위험도 평가를 위한 심근관류 SPECT의 유용성)

  • Lim, Seok-Tae;Lee, Dong-Soo;Kang, Won-Jun;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.273-281
    • /
    • 1999
  • Purpose: We investigated whether myocardial SPECT had additional usefulness to clinical, functional or surgical indices for the preoperative evaluation of cardiac risks in noncardiac surgery. Materials and Methods: 118 patients (M: F=66: 52, $62.7{\pm}10.5$ years) were studied retrospectively. Eighteen underwent vascular surgeries and 100 nonvascular surgeries. Rest T1-20l/ stress Tc-99m-MIBI SPECT was performed before operation and cardiac events (hard event: cardiac death and myocardial infarction; soft event: ischemic ECG change, congestive heart failure and unstable angina) were surveyed through perioperative periods ($14.6{\pm}5.6$ days). Clinical risk indices, functional capacity, surgery procedures and SPECT findings were tested for their predictive values of perioperative cardiac events. Results: Perioperative cardiac events occurred in 25 patients (3 hard events and 22 soft events). Clinical risk indices, surgical procedure risks and SPECT findings but functional capacity were predictive of cardiac events. Reversible perfusion decrease was a better predictor than persistent decrease, Multivariate analysis sorted out surgical procedure risk (p=0.0018) and SPECT findings (p=0.0001) as significant risk factors. SPECT could re-stratify perioperative cardiac risks in patients ranked with surgical procedures. Conclusion : We conclude that myocardial SPECT provides additional predictive value to surgical type risks as well as clinical indexes or functional capacity for the prediction of preoperative cardiac events in noncardiac surgery.

  • PDF

Clinical Study of Simultaneous Acquisition Rest 99mTc-sestaMIBI/Stress 201Tl Dual-Isotope Myocardial Perfusion Imaging with a Solid-State Dedicated Cardiac Gamma Camera (반도체 심근 전용 감마카메라를 이용한 Rest 99mTc-sestaMIBI/Stress201Tl 이중 동위원소 심근 관류 동시 스캔에 관한 임상적 고찰)

  • Bahn, Young-Kag;Kim, Dong-Heui;Choi, Yong-Hoon;Kang, Chun-Koo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.88-91
    • /
    • 2018
  • Purpose The purpose of this study is to investigate the simultaneous dual isotope (SDI) myocardial perfusion scan that can be performed in a short time using a semiconductor gamma camera. Materials and Methods Of the 86 patients who underwent Rest/Stress $^{99m}TC$-sestaMIBI 1-day myocardial perfusion scan and Rest $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope myocardial perfusion scan using a heart-only gamma camera, the test results were the same, 36 patients who did not show any change in the clinical outcome. Quantitative values were statistically analyzed using a QPS program to confirm the correlation between the images of the two examinations. Results Rest/Stress $^{99m}TC$-sestaMIBI simultaneous dual myocardial perfusion scans and $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ double-isotope myocardial perfusion scans were analyzed for Summed score. The $R^2$ value of the Rest summed score (RSS) was 0.91 and the $R^2$ value of the stress summed score (SSS) was 0.71. Conclusion The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan confirmed its correlation with the previous day's test. The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan can be completed in approximately 30minutes. It maybe clinically useful for patients who need short examination time such as emergency patients or elderly patients.