• Title/Summary/Keyword: Tc-99m

Search Result 1,347, Processing Time 0.042 seconds

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Detection of Spinal Metastases: Comparison of Bone Scan and MR Imaging (전이성 척추 악성 종양의 진단 : 골스캔과 자기공명영상의 비교)

  • Kim, Ki-Jun;Sohn, Hyung-Sun;Park, Jeong-Mi;Chung, Soo-Kyo;Lee, Jae-Moon;Kim, Choon-Yul;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.384-390
    • /
    • 1994
  • Authors retrospectively compared the 99mTc MDP bone scans and corresponding MR imagings in 20 patients with histologically proven malignancy, Mean interval of the two studies was 16.6 days, Cancer diagnosis Included 8 lung, 2 each of colon, breast, stomach, 1 each of prostate, thyroid, malignant lymphoma and 3 adenocarcinoma of unknown primary site. Of the 105 regions compared, :t6 regions were positive for metastases in bone scans or MR imagings. 30 regions(65.2%) were positive by bone scan and 44 regions(95.7%) by MR imaging. 87 regions(82.9%) were concordantly positive or negative by bone scan and MR imaging, but 18 regions(17.1%) were discordant. In the discordant regions, 16 regions positive in MR imaging were negative in bone scan. The greatest number of discordant findings occured in the cervical region and in the patient with stomach cancer. Our results suggest that the sensitivity of MR Imaging is greater than that of bone scan in detecting spinal metastases. And bone scan is useful screening test of metastasis for evaluating entire skeleton including spine.

  • PDF

Dipyridamole Induced Transient Left Ventricular Dysfunction in the Tl-201 Gated Myocardial SPECT (Tl-201 게이트 심근 SPECT에서 디피리다몰 부하로 유도된 일시적 좌심실 기능이상)

  • Won, Kyoung-Sook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.153-161
    • /
    • 2003
  • Purpose: Recently the occurrence of dipyridamole stress-induced short term stunning was proven and it is reported that Bland Altman analysis by repeated acquisition Tl-201 gated myocardial SPECT (gSPECT) revealed the 95% limit of agreement for LVEF was 10.3 %. The purpose of this study was to investigate the clinical value of dipyridamole induced transient LV dysfunction on Tl-201 gSPECT. Materials and Methods: Total 93 patients were included and coronary angiography was peformed in all patients less than 2 month from gSPECT. The patients with myocardial infarction were excluded. All patients underwent both dipyridamole stress and 4-h redistribution Tl-201 gSPECT. Forty nine patients of total 93 showed normal coronary arteries (Group 1) and the remaining 44 patients had coronary artery disease (Group 2). We compared LV EF, EDV and ESV during post-stress and 4-h redistribution period calculated by gSPECT using quantitative gated SPECT software and the incidence of dipyridamole induced transient LV dysfunction between group 1 and 2. The criteria for transient LV dysfunction was defined more decrease ${\geq}11%$ of LVEF during post-stress than 4-h redistribution according to previous reported Bland Altman analysis. Results: During post-stress and 4-h redistribution average of 3.1% increment in LVEF, 6.6% increment in LVEDV and 0.7% decrement in LVESV were shown after stress in Group 1, whereas 4.1% decrement, 9.7% increment and 7.2% increment in Group 2 respectively. Dipyridamole induced transient LV dysfunction was only detected in group 2 (18.2%) and not in group 1. It was more frequently observed in triple vessel disease and left main disease (31.8%, N=22) than one and two vessel disease (4.5%, N=22). Conclusion: As with Tc-99m myocardial agent post-stress LV dysfunction was observed in dipyridamole Tl-201 gSPECT. It was only detected in CAD and more frequently occurred in multivessel disease. Thus this finding seems to provide additional information in the diagnosis of coronary artery disease and prediction of prognosis.

Viability Assessment with T1-201 Rest-24 hour Delay Redistribution SPECT before Coronary Artery Bypass Graft in Coronary Artery Diseases (관상동맥 질환에서 우회로 수술 전 T1-201 휴식-24시간 지연 심근 관류 SPECT를 이용한 심근생존능의 평가)

  • Yoon, Seok-Nam;Kim, Ki-Bong;Lee, Won-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Jung-Don;Koh, Chang-Soon;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.493-501
    • /
    • 1996
  • To assess contribution of T1-201 rest-24 hour delay redistribution in detection of viable myocardium, we studied the predictive value of this redistribution in 17 patients who peformed rest-24 hour delay perfusion SPECT before bypass surgery. Regional wall motion was compared with gated SPECT in 10 patients and echocardiography in 7 patients before and after bypass surgery. Rest and 24 hour delayed uptakes were scored from 0 (normal perfusion) to 3 (defect). In rest SPECT, 56 segments showed perfusion decrease. Thirty four segments(61%) improved after surgery and were defined as viable Nineteen(34%) segments had more uptake of T1-201 at 24 hour delay, and the other 37 segments did not. In 81%(25/31) of segments with mildly decreased perfusion, wall motion after bypass surgery improved, 57% (8/14) of segments with severely decreased perfusion improved, and 9%(1/11) of segments with defects improved. In 14 among 19 segments which had more T1-201 uptakes at 24 hour delay, wall motion was improved(positive predictive value of redistribution: 74%). 20 among 37 segments which had persistent decreases in rest-24 hour redistribution improved and 17 did not(negative predictive value: 46%). Segments having severe perfusion decrease or defects showed improved wall motion after surgery in 64%(7/11), if it had redistribution at delay. Segments with either mildly decreased uptake in resting or rest-delayed redistribution showed improved wall motion in 76%(32/42). Among the 14 segments which showed improvement in wall motion, 10 had partial reversibility in stress-rest images and the other 4 had persistent perfusion defects in stress-rest images. These 4 segments were found viable only with rest-24 hour delayed perfusion SPECT. We concluded that rest T1-201 uptake or redistribution at 24 hour delay should be referred as an evidence to warrant postoperative improvement of abnormal wall motion and we could predict myocardial viability with preoperative rest-24 hour delay perfusion SPECT in the segments with rest perfusion decreases.

  • PDF

The Effects of Discrepancy in Reconstruction Algorithm between Patient Data and Normal Database in AutoQuant Evaluation: Focusing on Half-Time Scan Algorithm in Myocardial SPECT (심근 관류 스펙트에서 Half-Time Scan과 새로운 재구성법이 적용된 정상군 데이터를 기반으로 한 정량적 분석 결과의 차이 비교)

  • Lee, Hyung-Jin;Do, Yong-Ho;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.122-126
    • /
    • 2014
  • Purpose: The new reconstruction algorithms (NRA) provided by vendor aim to shorten the acquisition scan time. Whereas depending on the installed version AutoQuant program used for myocardial SPECT quantitative analysis did not contain the normal data that NRA is applied. Thus, the purpose of this paper is to compare the results according to AutoQuant versions in myocardial SPECT applied NRA and half-time scan (HT). Materials and Methods: Rest Tl and stress MIBI data of total 80 (40 men, 40 women) patients were gathered. Data were applied HT acquisition and ASTONISH (Philips) software which is NRA. Modified autoquant of SNUH and old version of AutoQuant (full-time scan) provided by company were compared. Comparison groups were classified as coronary artery disease (CAD), 24 hrs delay and almost normal patients who have a simple pain patient. Perfusion distribution aspect, summed stress score (SSS), summed rest score (SRS), extent and total perfusion deficit (TPD) of each 25 patient who have above diseases were compared and evaluated. Results: The case of CAD, when using re-edited AutoQuant (HT) SSS and SRS showed about 30% reduction (P<0.0001), Extent showed about 38% reduction and TPD showed about 30% reduction in the tendency (P<0.0001). In the score of the perfusion, especially on the part of infero-medium, infero-apical, lateral-medium and lateral-apical regions were the biggest change. The case of the 24 hrs delay patient SRS (P=0.042), Extent (P=0.018) and TPD (P=0.0024) showed about 13-18% reduction. And the case of simple pain patient, comparison of 4 results showed about 5-7% reduction. Conclusion: This study was started based on expectation that results could be affected by normal patient data. Normal patient data is possible to change by race and gender. It was proved that combination of new reconstruction algorithm for reducing scan time and analysis program according to scan protocol with NRA could also be affected to results. Clinical usefulness of gated myocardial SPECT is possibly increased if each hospital properly collects normal patient data for their scan acquisition protocol.

  • PDF

Comparison of the Results in Gastric Carcinoma Patients undergoing Billroth I and Billroth II Gastrectomiesy (원위부 위암에서 위절제술 후 위재건술식에 따른 잔위기능 및 영양 증상학적 삶의 질 비교)

  • Kim, Sung Geun;Kim, Young Kyun;Heo, Youn Jung;Song, Kyo Young;Kim, Jin Jo;Jin, Hyung Min;Kim, Wook;Park, Cho Hyun;Park, Seung Man;Lim, Keun Woo;Kim, Seung Nam;Jeon, Hae Myung
    • Journal of Gastric Cancer
    • /
    • v.7 no.1
    • /
    • pp.16-22
    • /
    • 2007
  • Purpose: The proper reconstruction technique to use after a distal subtotal gastrectomy for a gastric carcinoma, there has been a subject for debated what is the proper reconstruction technique. The aim of this study was to compare the gastricemptying time and the quality of life following both B-I and B-II reconstructions after a distal gastrectomy for a gastric adenocarcinoma. Materials and Methods: We studied 122 patients who had undergone a distal gastrectomy for a gastric adenocarcinoma between June 1999 and July 2002 at our hospital. 51 patients underwent B-I group, and 71 patients underwent B-II group. To evaluate the gastric-emptying time, we analyzed the T1/2 time by means of radionuclide scintigraphy using a gamma camera after ingestion of an $^{99m}Tc$-tin-colloid steamed egg. The nutritional status was measured by the weight change. Postgastrectomy syndrome was evaluated using an abdominal symptoms survey. Dumping syndrome was measured using the Sigstad dumping score. Results: The gastric-emptying time was somewhat delayed in the B-I group after a 6 month period, but there was no difference after 12 months between the two groups. There was less weight loss in the B-I group than in the B-II group (P=0.023). Fewer abdominal symptoms were occurred in the B-I group than in the B-II group. Dumping syndrome occurred less frequently in the B-I group than in the B-II group (P=0.013). Conclusion: In our study, the Billroth I reconstruction led to less weight loss, a better nutritional status, and a better quality of life than the Billroth II reconstruction. We concluded that after a distal subtotal gastrectomy, the Billroth I reconstruction would be considered when the procedure is oncologically suitable.

  • PDF

The Evaluation of Bone Scan and SPECT Before and After Treatment of TMD Patients (골관절염을 가진 측두하악장애 환자의 치료 전, 후 골스캔과 SPECT의 평가)

  • Kim, Byeong-Soo;Ahn, Yong-Woo;Ko, Myung-Yun;Park, June-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.57-67
    • /
    • 2005
  • The aim of this study was to evaluate bone scan(SUR) and SPECT(hot spot) in patients with TMJ osteoarthritis. 99mTc-MDP bone scan and SPECT were done in 27 patients, total 54 temporomandibular joints were examined with clinical examination, plain radiography. 42 TMJs were osteoarthritis and 12 TMJs were normal case, clinically diagnosed. We compared osteoarthritis group and control group of bone scan(SUR) and SPECT(hot spot). thus we compared before and after treatment of bone scan(SUR) and bone SPECT(hot spot) according to history, contributing factor, symptom degree, treatment, treatment period. The obtained results were as follows. 1. Bone scan(SUR) and SPECT(hot spot) activity of osteoarthritis group were higher than control group(P<0.05, P<0.01). 2. Bone scan(SUR) and SPECT(hot spot) activity were decreased after treatment at TMJ with osteoarthritis(P<0.01). 3. Bone scan(SUR) and SPECT(hot spot) activity were decreased at treatment group with splint(P<0.01, P<0.05). 4. Bone scan(SUR) and SPECT(hot spot) activity were decreased at Chronic group(P<0.01, P<0.05). 5. Bone scan(SUR) and SPECT(hot spot) activity were decreased at low noise NAS(<6) group(P<0.01,P<0.05). 6. Bone scan(SUR) and SPECT(hot spot) activity were decreased at TMD patient with parafunctional habit and without trauma history, psychosocial factor. 7. Bone scan(SUR) and SPECT(hot spot) activity were higher at before treatment required more treatment period.

Methodologies for Enhancing Immersiveness in AR-based Product Design (증강현실 기반 제품 디자인의 몰입감 향상 기법)

  • Ha, Tae-Jin;Kim, Yeong-Mi;Ryu, Je-Ha;Woo, Woon-Tack
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.2 s.314
    • /
    • pp.37-46
    • /
    • 2007
  • In this paper, we propose technologies for enhancing the immersive realization of virtual objects in AR-based product design. Generally, multimodal senses such as visual/auditory/tactile feedback are well known as a method for enhancing the immersion in case of interaction with virtual objects. By adapting tangible objects we can provide touch sensation to users. A 3D model of the same scale overlays the whole area of the tangible object so the marker area is invisible. This contributes to enhancing immersion. Also, the hand occlusion problem when the virtual objects overlay the user's hands is partially solved, providing more immersive and natural images to users. Finally, multimodal feedback also creates better immersion. In our work, both vibrotactile feedback through page motors, pneumatic tactile feedback, and sound feedback are considered. In our scenario, a game-phone model is selected, by way of proposed augmented vibrotactile feedback, hands occlusion-reduced visual effects and sound feedback are provided to users. These proposed methodologies will contribute to a better immersive realization of the conventional AR system.

Osteoporotic Vertebral Fractures: SPECT Findings (골다공증에 동반된 척추골절의 골 SPECT 소견)

  • Baik, Jun-Hyun;Park, Young-Ha;Ihn, Yon-Kwon;Kim, Sung-Hoon;Chung, Yong-An;Yoo, Ie-Ryung;Kim, Jee-Yeung;Jung, Hyun-Seok;Sohn, Hyung-Seon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.522-527
    • /
    • 2004
  • Purpose: The purpose of this study was to evaluate the usefulness of single photon emission computed tomography (SPECT) of bone using Tc-99m MDP in the diagnosis of osteoporotic vertebral fractures. Materials and Methods: Thirty two patients with osteoporotic vertebral fracture were included in this study (mean age: $67{\pm}8$, male: 5, female: 27). Seventy nine vertebral fractures were detected (38 thoracic/thoracolumbar lesions and 41 lumbar lesions), which were classified by type of deformity (wedge, biconcave or compression). The patterns and locations of increased uptakes were examined and analyzed. Results: Forty seven wedge fractures, 20 biconcave fractures and 12 compression fractures were found. Diffuse and asymmetric uptakes were common in fractured bodies. More than one uptake were examined in 69 posterior elements of fractured vertebrae (87.3%) including 40 of 47 wedge fractures (85.1%), 17 of 20 biconcave fractures (85.0%) and 12 of 12 compression fractures (100%). Wedge fractures were predominant fracture in thoracic/thoracolumbar spine whereas incidence of biconcave or compression type war similar to that of wedge fracture in lumbar spine (p=0.04). Spinous process uptake was more frequently seen in lumbar lesions than thoracic/thoracolumbar lesions (p=0.009). Facet joint uptake in biconcave fracture was more common in lumbar spine (92.3%) than thoracic/thoracolumbar spine (57.1%). Spinous process uptake in biconcave fracture was also more frequently detected in lumbar spine (p=0.043). Conclusion: Bone SPECT was useful in the evaluation of osteoporotic vertebral fracture, especially posterior elements of vertebrae.