• Title/Summary/Keyword: Target biopsy

Search Result 47, Processing Time 0.027 seconds

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

Paradigm Shift in Prostate Cancer Diagnosis: Pre-Biopsy Prostate Magnetic Resonance Imaging and Targeted Biopsy

  • Jung Jae Park;Chan Kyo Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.6
    • /
    • pp.625-637
    • /
    • 2022
  • With regard to the indolent clinical characteristics of prostate cancer (PCa), the more selective detection of clinically significant PCa (CSC) has been emphasized in its diagnosis and management. Magnetic resonance imaging (MRI) has advanced technically, and recent international cooperation has provided a standardized imaging and reporting system for prostate MRI. Accordingly, prostate MRI has recently been investigated and utilized as a triage tool before biopsy to guide tissue sampling to increase the detection rate of CSC beyond the staging tool for patients in whom PCa was already confirmed on conventional systematic biopsy. Radiologists must understand the current paradigm shift for better PCa diagnosis and management. This article reviewed the recent literature, demonstrating the diagnostic value of pre-biopsy prostate MRI with targeted biopsy and discussed unsolved issues regarding the paradigm shift in the diagnosis of PCa.

Development of Image Guided 3D Localization Program for Stereotactic Brain Biopsy (뇌 정위 생검술을 위한 영상지원 3차원 국재 프로그램 개발)

  • Lee Do Heui;Lee Dong Joon
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.197-201
    • /
    • 2004
  • Stereotactic brain biopsy using stereotactic head frame such as CRW (Radionics, USA) has demonstrated a precise lesion localizing accuracy. In this study, we developed the target point calculation program for brain lesion biopsy using CRW stereotactic head frame and designed a phantom for verify the new developed program. The phantom was designed to have capability to simulate clinical stereotactic brain biopsy. The phantom has 10 vertical rods whose diameters are 6mm and tip of each rods are 2mm. Each rod has different length, 150 mm x 4 ea, 130 mm x 4 ea, 110 mm x 2 ea. CT images were acquired with Simens CT scanner as continuous transverse slice, 1 mm thickness in a 25 cm field of view and stored in a dicom file as a 256 x 256 matrix. As a result, the developed new target localization program will be useful for planning and training in complicated 3 dimensional stereotactic brain biopsy.

  • PDF

Feasibility of Proton Chemical Shift Imaging with a Stereotactic Headframe

  • 백현만;최보영;손병철;정성택;이형구;서태석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.72-72
    • /
    • 2003
  • Purpose: To prove feasibility of proton chemical shift imaging (lH CSI) during stereotactic procedure, authors performed IH CSI in combination with a stereotactic headframe and selected targets according to local metabolic information, evaluated the pathologic results. Methods: The 1H CSI directed stereotactic biopsy was performed in five patients. 1H CSI was performed before conventional stereotactic MRI with gadolinium enhancement for stereotactic coordinates. The metabolite images expressed as integral ratios, Cho/Cr and Lac/Cr, were displayed in different colors. The stereotactic target coordinates were correlated with the coordinates from the 1H CSI images. Results: The final pathologic results obtained were concordant with the local metabolic information from 1H CSI. We believe that 1H CSI-directed stereotatic biopsy has the potential to significantly improve the accuracy of stereotactic biopsy targeting. Conclusions : Metabolic signals derived from 1H CSI could give us more direct clues for stereotactic target selection during the subsequent conventional stereotactic MR imaging. 1H CSI was feasible with the stereotatic headframe in place. The final pathologic results obtained were concordant with the local metabolic information from 1H CSI. Acknowledgement: This study was supported by a grant of the Center for Functional and Metabolic Imaging Technology, Ministry of Health & Welfare, Republic of Korea (02-PJ3-PG6-EV07-0002).

  • PDF

Cutaneous melanoma (피부흑색종)

  • Lee, Seok-Jong;Lee, Soo Jung
    • Journal of the Korean Medical Association
    • /
    • v.61 no.11
    • /
    • pp.662-669
    • /
    • 2018
  • The cutaneous melanoma has been regarded as rare disease entity in Korea for long time but it shows a silent growth recently. Furthermore the management of cutaneous melanoma including staging system, surgical principle, sentinel lymph node biopsy and subsequent complete node dissection and, most importantly, immunotherapy and target therapy against cutaneous melanoma recently. The incidence of cutaneous melanoma is steadily increasing in Korea but its increase is rapid recent 2 decades to 4.3 times and should be greater soon according to the steeper increase of life expectancy. New staging system proposed by American Joint Committee on Cancer (2017) includes changes in individual TNM category and stage groups, particularly from a prognostic viewpoint. Dermoscopy has been successfully introduced in the differential diagnosis of pigmented skin lesion focusing on cutaneous melanoma by non-invasive simple diagnostic tool. Sentinel lymph node biopsy was a issue of long debate whether survival benefit is real or not. Temporary conclusion about this question is reached after two large scale studies and immediate complete node dissection should be performed in a certain situations. Most important change is drug therapy focusing on immunotherapy and target therapy. Braf- and MEK-inhibitor, immune checkpoint inhibitor and PD-1 blocker has been proved to be effective as a sole or combination regimen against advanced and/or high-risk adjuvant setting of cutaneous melanoma. In conclusion, these remarkable changes will be reviewed shortly here.

Clinical Analysis of Stereotactic Biopsy in Brain Lesions (정위적 뇌생검의 임상분석)

  • Kim, Young Wook;Kim, Jae Hyoo;Seo, Seung Kweon;Lee, Jung Kil;Kim, Tae Sun;Jung, Shin;Kim, Soo Han;Kang, Sam Suk;Lee, Je Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • Objective : This study was undertaken to evaluate the benefits and risks of the stereotactic biopsy in brain lesions. We assessed the diagnostic accuracy and morbidity rate associated with the stereotactic biopsy. Methods : The authors present a review of 47 patients, who underwent stereotactic biopsy using Cosman-Roberts-Wells(CRW) stereotactic apparatus during last six years. Results : Target locations were supratentorial in 36 cases, infratentorial in 9 and multiple in 2. According to pathological diagnosis, the largest group was neoplasm(29) followed by infection(9), infarction(2), cyst(2), and non-specific(5). Definitive diagnosis could be made in 42 of 47 cases(89.4%). When the mass lesion had been suspected as neoplastic condition, the diagnostic rate was 96.7%(29/30). It was being much higher than that of non-neoplastic lesion, 76.5%(13/17). The treatment modality was changed in 15 cases(32%) because the result of stereotactic biopsy was different from clinical diagnosis. Subsequent craniotomy after stereotactic biopsy was then performed in 6 cases, and the pathological diagnoses were precisely coincident in all of these cases. There were two complications(4.3%) : One intratumoral hemorrhage in glioblastoma and a transient hemiparesis in benign astrocytoma. There was no mortality in this series. Conclusion : The precise histological verification is crucial to determine the adequate treatment modality in intracranial lesions. Stereotactic biopsy is a safe and accurate diagnostic procedure for intracranial lesions with a low complication rate.

  • PDF

Cone-Beam CT-Guided Percutaneous Transthoracic Needle Lung Biopsy of Juxtaphrenic Lesions: Diagnostic Accuracy and Complications

  • Wonju Hong;Soon Ho Yoon;Jin Mo Goo;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1203-1212
    • /
    • 2021
  • Objective: To investigate the diagnostic accuracy and complications of cone-beam CT-guided percutaneous transthoracic needle biopsy (PTNB) of juxtaphrenic lesions and identify the risk factors for diagnostic failure and complications. Materials and Methods: In total, 336 PTNB procedures for lung lesions (mean size ± standard deviation [SD], 4.3 ± 2.3 cm) abutting the diaphragm in 326 patients (189 male and 137 female; mean age ± SD, 65.2 ± 11.4 years) performed between January 2010 and December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PTNB procedures for the diagnosis of malignancy were measured based on the intention-to-diagnose principle. The risk factors for diagnostic failures and complications were evaluated using logistic regression analysis. Results: The accuracy, sensitivity, specificity, PPV, and NPV were 92.7% (293/316), 91.3% (219/240), 91.4% (74/81), 96.9% (219/226), and 77.9% (74/95), respectively. There were 23 diagnostic failures (7.3%), and lesion sizes ≤ 2 cm (p = 0.045) were the only significant risk factors for diagnostic failure. Complications occurred in 98 cases (29.2%), including 89 cases of pneumothorax (26.5%) and 7 cases of hemoptysis (2.1%). The multivariable analysis showed that old age (> 65 years) (p = 0.002), lesion size of ≤ 2 cm (p = 0.003), emphysema (p = 0.006), and distance from the pleura to the target lesion (> 2 cm) (p = 0.010) were significant risk factors for complications. Conclusion: The diagnostic accuracy of cone-beam CT-guided PTNB of juxtaphrenic lesions for malignancy was fairly high, and the target lesion size was the only significant predictor of diagnostic failure. Complications of cone-beam CT-guided PTNB of juxtaphrenic lesions occurred at a reasonable rate.

Initial experience of magnetic resonance imaging/ultrasonography fusion transperineal biopsy: Biopsy techniques and results for 75 patients

  • Tae, Jong Hyun;Shim, Ji Sung;Jin, Hyun Jung;Yoon, Sung Goo;No, Tae Il;Kim, Jae Yoon;Kang, Seok Ho;Cheon, Jun;Kang, Sung Gu
    • Investigative and Clinical Urology
    • /
    • v.59 no.6
    • /
    • pp.363-370
    • /
    • 2018
  • Purpose: The aim of this study is to describe the technique and to report early results of transperineal magnetic resonance imaging and ultrasonography (MRI-US) fusion biopsy. Materials and Methods: A total of 75 patients underwent MRI-US fusion transperineal biopsy. Targeted biopsy via MRI-US fusion imaging was carried out for cancer-suspicious lesions with additional systematic biopsy. Detection rates for overall and clinically significant prostate cancer (csPCa) were evaluated and compared between systematic and targeted biopsy. In addition, further investigation into the detection rate according to prostate imaging reporting and data system (PI-RADS) score was done. Results of repeat biopsies were also evaluated. Results: Overall cancer detection rate was 61.3% (46 patients) and the detection rate for csPCa was 42.7% (32 patients). Overall detection rates for systematic and targeted biopsy were 41.3% and 57.3% (p<0.05), respectively. Detection rates for csPCa were 26.7% and 41.3%, respectively (p<0.05). The cancer detection rates via MRI fusion target biopsy were 30.8% in PI-RADS 3, 62.1% in PI-RADS 4 and 89.4% in PI-RADS 5. Rates of csPCa missed by targeted biopsy and systematic biopsy were 0.0% and 25.0%, respectively. The cancer detection rate in repeat biopsies was 61.1% (11 among 18 patients) in which 55.5% of cancer suspected lesions were located in the anterior portion. Conclusions: Transperineal MRI-US fusion biopsy is useful for improving overall cancer detection rate and especially detection of csPCa. Transperineal MRI-US targeted biopsy show potential benefits to improve cancer detection rate in patients with high PIRADS score, tumor located at the anterior portion and in repeat biopsies.

Three OOP Haptic Simulator for a Needle Biopsy (3자유도 힘반향 장치를 이용한 침생검 햅틱 시뮬레이터)

  • 권동수;경기욱;감홍식;박현욱;나종범
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.539-539
    • /
    • 2000
  • This paper shows how to implement force reflection for a needle insertion problem. The target is a needle spine biopsy simulator for tumor inspection by needle insertion. Simulated force is calculated from the relationship of volume graphic data and the orientation and Position of the needle, and it is generated using PHANTOM$^{TM}$. To generate realistic force reflection, the directional force of the needle has been generated by tissue model. The other rotational force is generated using a pivot to keep the needle in the initial inserted direction after puncturing the skin. Since the used haptic device has limitation for generating high stiffness and large damping, scale downed model and digital filter are used to stabilize the system.m.

  • PDF

The study on Development and characteristic of ultrasound biopsy training phantom of breast (유방 초음파 팬텀의 제작과 특성에 관한 연구)

  • Ma, Sang-Chull;Kong, Young-Kun;Ahn, Young-Man
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.19-24
    • /
    • 2003
  • We carried out studies on development and characteristic of ultrasound brast training biopsy phantom. the major finding were of follow ; (1) C type TMM was shown good homogeneity, brightness and attenuation as like human soft tissue. (2) $TiO_2$ 4.10%w/v TMM was shown good homogeneous echo texture and propagated speed as like the human Tissue. (3) $TiO_2$ type TMM was appeared lower brightness and higher penetration rate than C type TMM. Therefor, Breast TM phantom and target material TMM will be useful $TiO_2$ 4.10 %w/v TMM and C 2.09 %w/v TMM.

  • PDF