• Title/Summary/Keyword: Target Slump

Search Result 70, Processing Time 0.028 seconds

Coating Effect by Applying Refined Cooking Oil on the Carbonation of High Volume Admixture Incorporating Concrete (정제유지류 도포가 혼화재 다량치환한 콘크리트의 탄산화에 미치는 영향)

  • Kim, Tae-Cheong;Choi, Young-Doo;Baek, Byung-Hoon;Shin, Dong-An;Oh, Seon-Kyo;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.146-147
    • /
    • 2014
  • In this study, as the resistance of the carbonation for high volume admixture incorporating concrete, coating effect of using refined cooking oil in the surface of high volume admixture incorporating concrete has been tested. The following results could be made as the conclusion. For the fresh concrete, the slump and air content has been identified as satisfying the target range. For the hardened concrete, comparing with specimen of Plain, specimen with coating showed better long age compressive strength. For the carbonation speed, the specimen of FA30 showed highest speed and the specimen of BS60 showed higher speed than specimen of Plain. For all the specimens coated with RCO, as the decrease of capillary pores inside the concrete, the carbonation speed has been obviously decreased and with even better effect than using PEP coating. It could be identified that specimens with coating by RCO showed good effect on refrain the speed of carbonation.

  • PDF

A Study on the Engineering Properties of Concrete Using Blast-furnace Slag Powder (고로슬래그 미분말을 사용한 콘크리트의 공학적 특성에 관한 연구)

  • Lee, Sang-Soo;Won, Cheol;Kim, Dong-Seok;Park, Sang-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.49-58
    • /
    • 2000
  • There are many methods to improve the performance of concrete. Especially, granuated blast furnace slag. by-products used in concrete as the replacement material of cement, could contribute to improve the fluidity, resistance of chemical attack and strength of concrete. Also, it could contribute to decrease the rate of generating hydration heat, in addition to cost-down of concrete and prevention of enviromental pollution. Therefore, in order to establish the systemical application of granuated blast furnace slag in normal concrete, the engineering properties of concrete, such as fluidity, strength, setting and hydration properties etc.. was evaluated. In this study, replacement ratio of granuated blast furnace slag was 0, 30, 50, 70(%), and target slump was 8, 12, 15, 18(cm). Results from the experiment, granuated blast furnace slag showed the outstanding effects of improving the engineering properties of concrete. From now on, positive application of granuated blast furnace slag is expected in the point of improving the performance and cost-down of concrete.

An Experimental Study on the Flowing and Strength Properties of Concrete using Meta kaolin (메타카올린을 사용한 콘크리트의 유동특성 및 강도특성에 관한 실험적 연구)

  • Lee Byung-Soo;Lee Sang-Soo;Song Ha-Young;Kim Eul-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.425-428
    • /
    • 2005
  • In this study, the experiment was carried out to investigate and analyze the strength properties and flowability of concrete using meta kaolin. The main experimental variables were water/binder ratio 40.0$\%$, water content 170kg/$m^{3}$ and mineral admixtures such as slag powder, silica fume and meta kaolin. According to the test results, the principle conclusions are summarized as follows. 1) The flowing property of concrete that uses meta kaolin appears to be the same to that of the silica fume concrete, but the slump flow that evaluates the compaction ability of concrete shows the most favorable performance. 2) The air content of the concrete that uses meta kaolin can be effectively controlled for the target performance in compliance with the use of AE agent. 3) When it comes to the strength of concrete that uses meta kaolin, the most favorable development of strength occurs when the replacement rate is 10$\%$, in case of the silica fume, and the slag power. In addition, as the replacement rate increases, so becomes the development of concrete strength favorable.

  • PDF

Field Application of Concrete Using Drying Shrinkage-Reducing Superplasticizer (건조수축 저감형 유동화제를 사용한 콘크리트의 현장적용)

  • Shin, Jae-Kyung;Oh, Chi-Hyun;Choi, Jin-Man;Lee, Seong-Yeun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.13-16
    • /
    • 2006
  • This study investigates filed application in Daebul Free Trade Zone of a flowing method using drying shrinkage-reducing superplasticizer(SRS) and an insulating curing method using double bubble sheets. Test showed that fresh concrete satisfied target slump and air content. A structure adding SRS significantly decreased the total bleeding capacity and accelerated the setting time. As for the crack occurrence, the structure applying the flowing method and double bubble sheets simultaneously exhibited the most favorable crack endurance, while conventional concrete showed more than 1mm size of crack in overall, and a structure applying only the flowing method partially presented micro crack. For the area proportion of crack occurrence, the structure using the double bubble sheets indicated 9.8%, while others applying flowing method was 28%, compared with 100% of conventional one. Standard curing specimens had about $3{\sim}6%$ higher compressive strength than that of specimens cured at adjacent field construction. In addition, using SRS improved about $5{\sim}7MPa$, than that of conventional concrete at 91 days elapse.

  • PDF

Field Application of the Flowing Concrete Method Considering Value Engineering(V.E) Concept (VE기법으로 유동화 공법 도입에 대한 현장 적용성 연구)

  • Shin, Hyun-Sup;Park, Yong-Kyu;Yoon, Jae-Ryung;Jeon, Chung-Keun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.21-24
    • /
    • 2006
  • This study investigates field application of flowing concrete in order to improve workability, duality and economic evaluation of concrete. Test results showed that slump of fresh concrete satisfied the target value before and after flowing concrete, and setting time indicated 3 hours difference depending on the mixture proportion of ready-mixed-concrete company. As for the hardened concrete, compressive strength of standard curing specimens, both control and flowing concrete, presented designed value at 28 days elapse. However, the specimens curing at atmosphere decreased the value, due to the lower curing temperature, but also performed the designed value at 91 days. For the evaluation of construction fee by value engineering(V.E) concept, a flowing method declined 4.89% of concrete construction fee, which is 4.9% reduction for materials and 25% reduction for labor expenses, compared with previous construction methods.

  • PDF

Investigation on Properties of Concrete with Crushed Sand on Site (부순모래를 사용한 콘크리트의 현장 품질 특성에 관한 실험 연구)

  • Lee, Sung-Bok;Lee, Do-Heon;Jee, Nam-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.3
    • /
    • pp.107-112
    • /
    • 2003
  • This study is to investigate the properties of concrete with crushed sand on site and to propose a quality guideline for its use as artificial sand and concrete. From our experimental result in laboratory and site, we found that demand water of concrete with crushed sand for target slump increased by 18kg/m3 compared to mixed sand and l8kg/m3 compared to sea sand respectively. The compressive strength increased by around 3∼6% when compared to concrete with sea sand. Accordingly, our study showed that the combined sand mixed with sea sand would be desirable to obtain workability and strength of concrete including dry shrinkage and bleeding test. Furthermore, the optimal replacement percentage of crushed sand was 50% with sea sand. As such, crushed sand would be sufficient as fine aggregate for concrete in terms of economic efficiency and quality. Crushed sand, on the other hand can only be used as fine aggregate when VFS(Very Fine Sand) is below 3.5 percentage of weight of sand and particle shape is above 55 percentage. Also, the particle shape and microsand passing NO.200 sieve should continually be improved to increase workability of concrete on site.

Mock-up Test of Concrete using Combined Coarse particle Cement and Fly-Ash (굵은 입자 시멘트 및 플라이애시를 복합 사용한 콘크리트의 Mock-up Test)

  • Lee, Chung-Sub;Lee, Jae-Youn;Jang, Duk-Bae;Kim, Young-Pil;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.87-91
    • /
    • 2009
  • This study investigates possibility for practical use through small sized test with OPC and substituted fly ash 10% and return coarse cement (RCC), classed 1100${\sim}$1200 cm2/g, which is made by Cyclone Separator at cement producing process 20% (CF) for OPC. The experimental factors are 48% of W/B and OPC and 2 kinds of concrete proportions. The target slump and air content are $150{\pm}25$ mm and $4.5{\pm}1.5$ %. For the results, the flowalility and air content of CF are less than OPC because it needs more superplasticiser and air-entraining agent. The temperature history of CF is lower than OPC about $6{\sim}10^{\circ}C$. For the strength properties, CF is less than OPC, but their gap is declined at 28 days. The strength of the specimens are ordered by standard curing, field cured specimens, and core specimens.

  • PDF

Chemical Resistance of Low Heat Cement Concrete Used in Wastewater Treatment Structures Built on Reclaimed Land (해안매립지 하수처리시설물에 적용한 저발열시멘트 콘크리트의 내화학성 평가)

  • Chung, Yongtaek;Lee, Byungjae;Kim, Yunyong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.113-119
    • /
    • 2019
  • Concrete structures built on reclaimed land are combined with chemical erosion such as chlorine and sulfate ions from seawater. Chloride attack deteriorates the performance of the structure by corroding reinforcing bars. In addition, the waste water treatment structure has a problem that the concrete is deteriorated by the sulfate generated inside. Therefore, in this study, the characteristics and chemical resistance of low heat cement concrete used in wastewater treatment structures constructed on reclaimed land were evaluated. As a result of the experiment, the target slump and air content were satisfied under all the mixing conditions. The slump of low heat cement (LHC) concrete was higher than that of ordinary portland cement (OPC) concrete, while the air content of LHC concrete was smaller than that of OPC concrete with the same mix proportion. As a result of compressive strength test, OPC concrete showed higher strength at younger age compared to 28 days. In contrast, LHC concrete exhibited higher strength than OPC concrete at the age of 56 days. As a result of chlorine ion penetration tests, LHC-B concrete showed chlorine ion penetration resistance performance of the "very low" level at the age of 56 days. As a result of chemical resistance evaluation, when the LHC concrete is applied without epoxy treatment, chemical resistance is improved by about 18% compared to OPC concrete. In testing chemical resistance, the epoxy coated concrete exhibited less than 5% strength reduction when compared to sound concrete.

Autogenous Shrinkage Mock-up Test of High Performance Concrete by Emulsified Refined Cooking Oil (유화처리 정제식용유를 사용한 고성능 콘크리트의 자기수축 Mock-up 실험)

  • Jo, Man-Ki;Han, Cheon-Goo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.307-315
    • /
    • 2016
  • The aim of this research is analyzing the fundamental properties and autogenous shrinkage reducing performance of 70 and 100MPa grade high performance concrete including emusified refined cooking oil(ERCO) under the mock-up conditions. As a results of experiment, the mixture contained 0.5% of ERCO showed slightly decreased slump flow while the slump was increased and segregation resistance performance was improved as 2.5 of EIS. For air content, all mixtures satisfied target air content with increased unit weight and delayed setting time with ERCO addition. In the case of compressive strength, when ERCO was added 0.5%, the result of approximately 5 to 10% of increased compressive strength was observed. For the autogenous shrinkage, ERCO contributed on 20-30% of shrinkage reducing performance comparing to Plain mixture without ERCO. It is considered that capillary pore filling action of soap particles occurred by the reaction of ERCO in cement paste between fatty aicd and calcium hydroxide contributed the shrinkage reducing performance. Based on these mock-up test results, application of the high performance concrete mixture with ERCO on CFT actual structure was decided.

Flowability Properties of Combined High Flowing Self-Compacting Concrete to the Addition of Viscosity Agent (증점제 첨가량 변화에 따른 병용계 고유동 자기충전 콘크리트의 유동특성)

  • Choi, Yun-Wang;Jeong, Jae-Gwon;Eom, Joo-Han;Choi, Wook;Kim, Kyung-Hwan;Moon, Dae-Joong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.369-372
    • /
    • 2008
  • In this research experimentally analyzes the flow characteristics of a combined High flowing Self-Compacting Concrete of which the viscosity agent and defoaming agent addition amount are changed, to make the combined High flowing Self-Compacting Concrete that can secure the required flow performance and air amount. As a result of the experiment, the slump flow of the combined High flowing Self-Compacting Concrete added with viscosity agent increases when the viscosity agent addition amount is 0.2%(${\times}$W %). When viscosity agent addition amount increases, viscosity agent shows that it largely deviates from the regulation value in the flow time of V-funnel, which is presented in the JSCE standards (grade 2). Also, all mixtures, except for mixtures added with viscosity agent, defoaming agent, and AE agent, do not meet a target air amount $4.5{\pm}1.5%$. High flowing Self-Compacting Concrete mixtureadded with defoaming agent shows that although time passes after its first mixture, its air amount reduces a little. Based on the experiment, we can know an optimal polymer amount to obtain the required flow performance

  • PDF