• 제목/요약/키워드: Tapered geometry

검색결과 22건 처리시간 0.027초

종횡비가 큰 사각 덕트내 난류 유동의 대류 열전달 증진 기술에 대한 연구 (TURBULENCE HEAT TRANSFER ENHANCEMENT TECHNIQUE FOR SQUARE DUCT WITH HIGH ASPECT RATIO)

  • 이찬용;신승원;정하승;박승호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.305-307
    • /
    • 2010
  • In this study, we develop a method to achieve heat transfer enhancement inside a square duct with high aspect ratio without changing any inner structures. Especially, a method to lower the possible maximum temperature is suggested if constant heat flux is provided to single surface of square duct. Knowing the fact that heat transfer rate is inversely proportional to flow area, we proposed tapered channel concept which uses narrower gap toward the flow exit where the maximum temperature is expected. To maintain equivalent power consumption, inlet section has been enlarged. To verify the proposed concept, experimental tests have been performed.

  • PDF

임플란트의 형태가 초기 안정성에 미치는 영향 (Influence of Implant Designs on Initial Stability)

  • 조재명;김창섭;윤미정;정창모;서승우
    • 구강회복응용과학지
    • /
    • 제26권1호
    • /
    • pp.47-57
    • /
    • 2010
  • 임플란트-골 계면상에 미세동요 없이 회복기를 가지는 것은 골융합을 위해서 필수적이다. 이를 위해 임플란트의 초기 안정성은 성공적인 예후를 위해서 중요한 요건이다. 충분한 골질과 골량은 임플란트의 초기 안정성과 조기 실패 방지를 위해 중요한 요소이지만, 임플란트가 갖는 외형적 특성이 초기 안정성에 미치는 영향에 대한 연구는 부족하다. 이에 본 연구는 임플란트의 형태가 초기 안정성에 미치는 영향을 알아보고자 하였다. 골질에 따라 피질골과 해면골의 두께가 서로 다른 모형골에 straight body의 US II, GS II, SS II system과 tapered body의 GS III system (OSSTEM Implant Co., Seoul, Korea) 임플란트를 식립하고 식립 회전력과 공진 주파수 및 동요도를 측정하였다. 이번 실험에서 초기 안정성에 주요한 영향을 미치는 요소는 골질로 나타났다. 임플란트의 형태에 따라 이중 나사선을 가지는 GS II 임플란트가 초기 안정성은 높게 나타났으며 tapered 한 임플란트가 straight 임플란트에 비해서 높은 초기 안정성을 얻을 수 있음을 알 수 있었다. 또한 tapered 임플란트 식립 시 임플란트의 외형과 조화된 식립구를 형성하는 것이 피질골이 두꺼운 경우 피질골에 과도한 압축력을 감소시키고 반대의 경우 해면골로부터 좀 더 많은 골고정을 얻을 수 있음을 알 수 있었다.

3종의 임프란트 형태에 관한 연구 (THE STUDY ON THE IMPLANT GEOMETRY)

  • 이용찬
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권2호
    • /
    • pp.245-252
    • /
    • 1996
  • The purpose of this study was to develop the implant which has superior stress distribution and primary stability to others by using Instron test and finite element method. The model used in the experiment were cylinder type implant, tapered screw type implant, screw type implants. Recognizing that the number of samples were small and the lack of applying press-fit conditions to the cylinder type, we can make the following conclusions.

  • PDF

탄소섬유/에폭시 복합재료의 층간파괴인성에 미치는 균열진전각도의 영향 (Effect of Crack Propagation Directions on the Interlaminar Fracture Toughness of Carbon/Epoxy Composite Materials)

  • 황진호;황운봉
    • 대한기계학회논문집A
    • /
    • 제23권6호
    • /
    • pp.1026-1038
    • /
    • 1999
  • Interlaminar fracture toughness of carbon/epoxy composite materials has been studied under tensile and flexural loading by the use of width tapered double cantilever beam(WTDCB) and end notched flexure(ENF) specimens. This study has significantly examined the effect of various interfacial ply orientation, ${\alpha}(0^{\circ},\;45^{\circ}\;and\;90^{\circ})$ and crack propagation direction, ${\theta}(0^{\circ},\;15^{\circ},\;30^{\circ}\;and\;45^{\circ})$ in terms of critical strain energy release rate through experiments. Twelve differently layered laminates were investigated. The data reduction for evaluating the fracture energy is based on compliance method and beam theory. Beam theory is used to analyze the effect of crack propagation direction. The geometry and lay-up sequence of specimens are considered various conditions such as skewness parameter, beam volume, and so on. The results show that the fiber bridging occurred due to the non-midplane crack propagation and causes the difference of fracture energy evaluated by both methods. For safer and more reliable composite structures, we obtain the optimal stacking sequence from initial fracture energy in each mode.

사출구 구조에 따른 옥수수가루 압출성형물의 팽화특성 (Effect of Die Geometry on Expansion of Corn Flour Extrudate)

  • 구본재;류기형
    • 산업식품공학
    • /
    • 제15권2호
    • /
    • pp.148-154
    • /
    • 2011
  • 사출구 구조가 압출성형의 목적변수인 팽화특성에 영향을 미치는지 알아보기 위하여 사출구의 기하학적 구조를 사출구상수로 산출하여 사출구상수와 수분함량에 따른 팽화특성을 비롯한 비기계적 에너지 투입량, 수분용해지수, 수분흡착지수를 분석하였다. 압출성형 공정변수는 수분함량(20, 25%), 사출구멍의 길이와 직경비(L/D 0.67, 1.67, 2.67), 내벽에서 좁아지는 각(57, $95^{\circ}$)이였다. 비기계적 에너지 투입량은 수분함량 20%, 사출구상수 2.23E-10 $m^3$에서 가장 높은 값을 나타내었다. 수분함량 20%에서 사출구상수가 증가하면, 직경팽화지수와 체적팽화지수는 증가하였다. 한편 수분함량 25%에서 직경팽화지수와 체적팽화지수는 사출구상수의 영향을 받지 않았다. 또한 길이팽화지수는 수분함량이 20%에서 25%로 증가할 때 증가하였으며 직경팽화지수와 음의 상관관계를 나타내었다. 수분흡착지수와 수분용해지수는 사출구상수에 영향을 받지 않았다.

테이퍼 베어링 유닛의 내구수명 예측 (Endurance Life Estimation of Taper Bearing Units)

  • 안태길;이상훈
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.160-164
    • /
    • 2007
  • An automotive wheel bearing is one of the most important components to guarantee the service life of a passenger car. The endurance life of a bearing is affected by many parameters such as material properties, heat treatment, lubrication conditions, temperature, loading conditions, bearing geometry, internal clearance and so on. Generally, a tapered roller bearing gives longer endurance life than that of an equivalent size ball bearing. Consequently, the application of taper bearing units will be increased for more compact design and extended warranty. In this paper, we derive the relation between loads and deformations of a taper bearing unit. On the basis of that, we calculate the endurance life of the taper bearing unit considering initial axial clearance.

Comparative Biomechanical Study of Self-tapping and Non Self-tapping Tapered Dental Implants in Artificially Simulated Quality 2 Bone

  • Baek, Yeon-Wha;Kim, Duck-Rae;Park, Ju-Hee;Lim, Young-Jun
    • Journal of Korean Dental Science
    • /
    • 제4권2호
    • /
    • pp.52-58
    • /
    • 2011
  • Purpose: Modifications of implant design have been related to improving initial stability. The purpose of this study was to investigate their respective effect on initial stability between two tapered implant systems (self-tapping vs. non-self-tapping) in medium density bone using three different analytic methods. Materials and Methods: Self-tapping implant (GS III$^{(R)}$; Osstem Implant Co., Busan, Korea) and non-self-tapping implant (Replace Select$^{(R)}$; Nobel Biocare, G$\H{o}$teborg, Sweden) were investigated. In Solid rigid polyurethane blocks of artificially simulated Quality 2 bone, each of the 5 implants was inserted according to the manufacturer's instructions for medium-bone drilling protocol. Evaluation of initial stability was carried out by recording the maximum insertion torque (IT) and performing the resonance frequency analysis (RFA), and the pull-out test. Results: The IT and RFA values of self-tapping implant were significantly higher than those of non self-tapping implant (P=.009 and P=.047, respectively). In the pull-out values, no significant differences were found in implants between two groups (P=.117). Within each implant system, no statistically significant correlation was found among three different outcome variables. Conclusions: These findings suggest that design characteristics of implant geometry significantly influence the initial stability in medium bone density.

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.

하이브리드 자외선 노광법을 이용한 3차원 고종횡비 미소구조물 제작 (Hybrid UV Lithography for 3D High-Aspect-Ratio Microstructures)

  • 박성민;남경목;김종훈;윤상희
    • 대한기계학회논문집A
    • /
    • 제40권8호
    • /
    • pp.731-736
    • /
    • 2016
  • 본 연구에서는 의용생체공학에 널리 사용되는 미소바늘과 같은 3차원 고종횡비 미소구조물을 용이하게 제작할 수 있는 하이브리드 자외선 노광법에 대해 기술한다. 하이브리드 자외선 노광법은 기존에 사용되고 있는 경사노광, 회전노광 및 역노광을 혼합한 방법으로, 경사 및 회전노광은 경사진 축대칭 형상을 가지는 3차원 미소구조물의 제작이 가능하도록 하고 역노광은 자외선 노광공정 중 필연적으로 발생하는 하부기판에서의 자외선 반사를 최소화 시킨다. 자체 개발한 자외선 노광시스템과 SU-8 음성감광제를 이용하여 하이브리드 자외선 노광법의 다양한 공정조건이 최종 제작된 3차원 고종횡비 미소구조물 형상(종횡비, 선단의 곡률반경 등)에 미치는 효과를 확인한다. 또한 SU-8의 소프트 베이킹(soft baking) 조건과 미소구조물 선단 형상 사이의 관계에 대해서도 논의한다.