• Title/Summary/Keyword: Tank cover

검색결과 44건 처리시간 0.024초

열사이폰식 태양열 온수시스템의 성능실험 (Performance Tests on a Solar Water Heating System in Thermosyphonic Flow)

  • 김두천;박승덕
    • 대한설비공학회지:설비저널
    • /
    • 제9권2호
    • /
    • pp.93-103
    • /
    • 1980
  • A small domestic solar water heating system in thermosyphonic flow was tested in Seoul. The system consisted of four flat plate aluminium roll bond type collectors of total effective area $3.28m^2$ and a $280{\iota}$ storage tank. It was tilted $52^{\circ}$ relative to the horizon. And the collector plate, collector tube and storage tank were equiped with 14 thermocouples. As the results, the following facts were found; 1) To provide water at $55^{\circ}C$ for a family of four in Seoul, a collector area of $3-4m^2$ and a storage capacity of $180{\iota}- 200{\iota}$ are suggested. And this system can supply hot water at above $45^{\circ}C$ day about. 2) In the late afternoon hours, it might be advantageous to stop the flow in the system as heat losses to the environment increase unduly. 3) Without any hot water consumption throughout the day, water temperature distributions inside the storage tank was found almost linear. This indicates essentially no mixing inside the storage tank. 4) In case of a small domestic solar water heating system, it is better to employ a single transparent cover rather than double one.

  • PDF

광해복원 경사지 밭의 토양유실 평가를 위한 현장실험 - 화학적 성질과 경사도 조건에서 - (A Pilot Experiments for Evaluation of Cover Soil Loss from Inclined Upland around Remediated Abandoned Mine Site - The Condition of Chemical Characteristics and Inclination -)

  • 윤성욱;강희천;권요셉;고일하;정문호;유찬
    • 한국농공학회논문집
    • /
    • 제64권2호
    • /
    • pp.37-45
    • /
    • 2022
  • In-situ pilot experiment was carried out to establish a countermeasure on the soil loss from the hill side uplands that was rehabilitated by soil remediation method nearby abandoned mine sites for 2 years. It was considered that the affect of an inclination of cover surface, a stabilization treatment of cover layer by lime and steel refining slag (SRS) and a vegetation of soil surface as an effect factors in the experiment. It was constructed 4 lysimeters (plots, 22 m long, 4 m width) on the hilly side (37% inclination). One plot was control and two plots was treated by 1% lime and SRS. A remind one plot was modified a inclination to 27% to compare the affect of inclination on the amount of cover soil loss. It was attached a reservior tank and water level gauge in the end of lysimeters to measure the amount of the surface water flow and soil loss. It was also installed the automated sensors that could be collect the precipitation, soil moisture content, tension of cover layer in each plots. It was observed that the event of precipitation were caused the soil loss and it were related the physical and chemical properties of cover soil and inclination of surface layer of plots. During the experiment, it was exceeded the national regulation (50 t/ha/yr) in 37% inclination plots even though it was vegetated on the cover soil surface. However, in 27% inclination plot, it was shown that the amount of soil loss was maintained below the national regulation and, more ever, vegetation could reduce the the amount of soil loss. Therefore it was expected that such results could be applied to the future design of rehabilitation projects on the polluted farmland nearby abandoned mine sites.

한랭 조건하에서 세가지 매립지복토 시스템에 대한 평가 (The Evaluation of Three Landfill Cover Systems in Cold Condition)

  • 이재영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.15.1-20
    • /
    • 1995
  • 일반적으로 일반 및 유해폐기물 매립지에서 진흙층의 기능적 수행목적은 다음과 같다고 할 수 있다. 지표면 유출의 증진을 위하고, 우수의 침투억제 및 폐기물의 표면 노출 시 완충작용, 따라서 최종복토의 붕괴는 이러한 중요 기능을 마비시키고 있다. 본 연구는 추운 날씨상태의 폐기물 매립지 최종복토의 거동을 수행하였으며, 실제로 설계된 세 개의 거대한 실험실 Tank에서 복토에 대한 실험이 시행되었다. 이 거대한 실험장비의 제원은 0.75m x 2.4m와 2.0m 깊이로 되어 있다. Tank안은 시방서적으로 폐기물 매립지가 요구하는 진흙층과 최종복토를 위한 물질로 채워졌다. 그들의 실험결과는 동질/융해에 따른 진흙과 복토층의 붕괴현상은 물리적, 공학적인 측면에 영향을 주는 것으로 나타났다. 본문은 실험에 사용된 복토층의 묘사, 그들의 실험결과들과 실험을 통한 결과분석 및 결론을 설명하고 있다. 실험결과로서는 각 모형들의 우수와 침출수 자료, 온도변화의 배경과 최종복토에서의 Water Balance를 포함하고 있다. 또한 결과로서 시험된 세 개의 모형들은 매립지에서의 동결깊이(29cm~32cm)를 나타내주며 그들 중 하나의 모형은 배수층을 가지고 있어 침출수억제에 효과적이므로 다른 모형보다 복토층으로서 우위에 있다는 것을 지적하고 있다.

  • PDF

BATCH형 자연형 태양열 온수급탕 시스템의 열적 성능에 관한 실험적 연구 (Experimental Study for Thermal Performance of Batch Type Passive Solar Hot Water System)

  • 강용혁;조일식;윤환기;오정무
    • 태양에너지
    • /
    • 제7권1호
    • /
    • pp.3-13
    • /
    • 1987
  • A batch type passive solar water systems, which perform the dual function of absorbing the solar energy and storing the heated water, have been designed and fabricated for the purpose of side-by-side testing at KIER. The test models included an A, B and C type batch systems which were classified according to the design of box and arrangement of tanks. The year-round performance tests show that B type batch system taken the step-wise tank arrangement indicates 55.7% yearly-average collection efficiency factor and 61% yearly-average maximum collection efficiency factor. Computer-aided-experimental results show that the sufficient hot water can be obtained in the early morning if the glazing is supplemented by a reflector/insulation cover. The thermal performance equation has been developed for the prediction of hourly variation of the water temperature in tank.

  • PDF

강변여과수를 이용한 온실난방기술 개발 (Greenhouse Heating Technology Development by using Riverbank Filtration Water)

  • 문종필;이성현;권진경;강연구;유영선;이수장
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.145-152
    • /
    • 2011
  • In order to heat greenhouse nearby river channel, riverbank filtration water source heat pump was developed for getting plenty of heat flux from geothermal energy. Recharging well, thermal storage tank with separating insulation plate and filtering tank for eliminating iron, manganese were mainly developed for making the coefficient of performance (COP) of heat pump higher. Heating system using riverbank filtration water source heat pump was installed at a paprika greenhouse in the Jinju region where a single fold of vinyl cover and 2 layers of horizontal thermal curtain were installed as a part of temperature keeping and heat insulation with a greenhouse area of 3,185 $m^2$. 320,000 kcal/h was supplied for performing a site application tests. A greenhouse heating test was performed from Feb. 1, 2011 to Apr. 30, 2011. As the result of that, COPh of the heat pump was measured in the range of 4.0~4.5, while COPS of the system was represented as 2.9~3.3. COP measured of the heat pump was very good and well responded to indoor heating temperature of the environment control system of a greenhouse.

우수토실에 설치된 월류수 제어를 위한 유입유량조절장치의 개선효과 (Improvements of Inflow Controller Installed in Storm Overflow Diverging Tank for CSOs Control)

  • 임봉수;박윤해;김태응
    • 한국물환경학회지
    • /
    • 제31권4호
    • /
    • pp.428-435
    • /
    • 2015
  • This study was carried out to evaluate the performance of a inflow controller for the control of combined sewer overflows (CSOs). Because of the inflow controller could be adjusted manually by predicting the maximum amount of peak flow, the mechanical adjustment of this controller was higher than the existing fixed-type controller in field application. Standardizing the relationship between the flow and the clearance and angle of an inlet cover plate on the inflow conditions can selected to the optimum conditions for the on-site. It was concluded that BOD pollutant loading at the region in which inflow controller was installed had shown the removal efficiency rate of 42%.

저가 Batch형 온수급탕시스템의 실험적 연구 (Experimental Study of a Low Cost Batch Type Solar Water Heater)

  • 이길동;윤환기;강용혁;이내준;오정무
    • 태양에너지
    • /
    • 제5권2호
    • /
    • pp.60-69
    • /
    • 1985
  • A low cost batch type solar heaters (capacity 200 litres) comprising horizontal tanks, which performs the dual function of absorbing heat and storing the heated water, have been designed and fabricated for the purpose of side-by-side testing. Experimental results have indicated that the sufficient hot water can be obtained in the early morning if the glazing is aided by a reflector/insulation cover. The water heater with best thermal performance such as type B supplied water at a maximum mean temperature of $46-49^{\circ}C$ in the summer afternoon and the temperature of $36-39^{\circ}C$ can be obtained in the early morning if insulation cover is used during night time. The equation has been developed for the prediction of hourly variation of the water temperature in the tank.

  • PDF

압축 충격파를 이용한 평판형상 세라믹의 파괴거동 (Fracture Behavior of Plate Shape Ceramic using Compressive Shock Wave)

  • 황권태;김재훈;이영신;박종호;송기혁;윤수진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.103-106
    • /
    • 2009
  • Fracture characteristics of plate shape using shock tube for glass filled ceramics was carried out. Glass filled ceramics have been considered as a promising candidate material for the dome port cover of air breathing engine. This part of the air breathing engine has an important role separating solid and liquid fuel, and needs the frangible characteristics that the fracture of a part should not affect the internal components of combustion. The objectives of this study are to evaluate the fracture pressures for various thicknesses and diameters of shock impact area. Also fracture phenomena of separated membrane using a shock tube are observed. The experimental apparatus of shock tube consists of a driver, a driven section and a dump tank. The used material is glass filled ceramic made from Corning company. Specimens are used 3, 4.5 and 6mm thickness. Also diameters of shock wave area are chosen 70, 60 and 50 mm. It is expected that the results obtained from this study can be used in the basic data for the dome port cover design of an air breathing engine.

  • PDF

921 Taiwan Earthquake

  • Chow, Ting
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.17-17
    • /
    • 2000
  • A magnitude of 7.3 in Richter scale earthquake the strongest in-land earthquake in hundred years struck central Taiwan on September 21, 1999. It caused over 2,400 deaths and 30 some trillion won losses. To give an overview of this devastating earthquake this presentation will cover the following topics: 1) Introduction to Taiwan historical and 921 earthquake. 2) Damages to people landslide building dam bridge tank power facility etc. 3) Strong motion data and its characteristics. 4) Some changes to the building code triggered by the experience of the earthquake. Finally a concluding remark will be made.

  • PDF

제과공장의 폐수처리장에서 발생하는 악취 저감 (Reduction of the Offensive Odor from Confectionery Wastewater Plant)

  • 김영식;손병현;조상원;정종현
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.62-69
    • /
    • 1998
  • It has been studied that the measurement of odor component emission at confectionery manufacture. The objects of this study were to investigate reduction of offensive odor. The survey effects of odorous materials are presented as follows. The countermeasure of operating process is to minimize sludge sediment in each unit facility. Especially, in summer, we have to clean the sludge frequently, because anaerobic decomposing is likely to occur easily. The sludge or scum from sedimentation tank pond, and floating tank should be treated quickly. We should avoid overloading operation. In the case of overloading, dissolved oxygen should be increased, the quality of wastewater input should be decreased. When dried cakes from condense tank or floating tank are left in treatment plant, we should cover, to prevent diffusion of smell with masking materials. The seasonal condition of operating should be fixed and the kind of coagulants should be changed because the wastewater in each season have different loading rates and organic materials. Odorous materials are very sensitive to the seasonal temperature variation. Especially, when the amount of rainfall is small and the high temperature of maintenance in long periods, air diffusion rate is large, so odorous materials can make great effect on surroundings comparision with other periods. To reduce odorous gas, as short term method, we had better take ceramic addition method. Especially, in summer we should take ceramic addition method. Also, as long term method, the size of wastewater treatment facility is the most important in the normal operating of wastewater treatment facility. But wastewater treatment facilities in this factory are too old, treatment process is old fashion, and the size is too small. So, large wastewater quantity to treat in summer. As results, the expansion of wastewater treatment facility and the process of improvement are required. Restriction level of odor was exceed. As it is overloaded in summer, the basis cause of odor is that the size of wastewater treatment facility is small. The prediction of air quality equilibrium density variation show that the odorous materials from working place are Amine materials whose smell strength is about 2.5(a little strong degree). We can suppose that in summer is sensitive to temperature variation, smell strength is larger as to reduce the origin of odor. We must expand wastewater treatment facility and improve the process A.S.A.P.

  • PDF