Evaluation of Denitrification Efficiency by Sulfur Denitrification Process according to Injection Type (유입방식 변화에 따른 황 탈질조의 탈질효율 평가)

  • Yoo, Tae-Kyoung;Choi, Yong-Bum;Kwon, Jae-Hyouk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.262-269
    • /
    • 2016
  • This study examined the influent of a sulfur denitrification reactor using nitrified effluent from a batch type reactor. The denitrification efficiency was compared according to the injection type. The nitrogen removal effects were compared with the changes in the EBCT and nitrogen concentration of the influent to determine the optimal operation conditions with the selected injection type. A denitrification efficiency evaluation of a reactor according to the change in injection type and up-flow was performed using a lower organic concentration of the effluent than the down-flow because of the re-precipitation of desorbed microbes and spilled solids. In the up-flow type, organics were controlled by the low concentration than the down-flow type because of solid re-precipitation. The T-N removal efficiency of the up-flow type was 73.3~90.2%, which was more that 10% higher that down-flow type. This means that the up-flow type has a great advantage in removing T-N and organics. The T-N removal efficiency by EBCT at 1hr was 47.3%, and was 88.1% and 90.5% by EBCT 3hr and 5hr, respectively. Therefore, the optimal operation conditions to remove nitrogen was considered to be EBCT for 3hr. After careful consideration of rule of law and T-N removal effects, the T-N load factor in the reactor should remain below $0.443kgT-N/m^3{\cdot}day$ to maintain the legal total nitrogen concentration for discharge, which is 20mg/L.

Industrial Wastewater Treatment Containing High Concentration of Ammonia with Low Energy Micro-Bubble Reactor (저에너지 마이크로버블 장치를 이용한 고농도 암모니아 공장 폐수 처리)

  • Jung, Jae-Ouk;Jung, Yong-Jun
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.286-291
    • /
    • 2016
  • This study was carried out to evaluate the feasibility of air-stripping by DIWS(Dip Injection Wet Scrubber) system on high concentration of ammonia wastewater more than 10,000 mg/L. In the case of changing temperature from $30^{\circ}C$ to $70^{\circ}C$ maintaining pH 12.5 within the 72 hours, the removal efficiency of T-N by the present treatment plant was increased to 90.5% which was initially kept 70.3%. Although the high concentration of T-N with 9,120~12,955 mg/L was treated by micro-bubble through DIWS system maintaining the temperature of $30^{\circ}C$ within the 20 hours, the removal efficiency of T-N reached 91.9%, which indicated the possibility of air-stripping.

Binaural Interaction Component in Auditory Brainstem Responses with Asymmetric Simultaneous Acoustic Stimulation (비대칭 음 강도 양이 동시 자극 청성뇌간유발반응의 양이간섭치)

  • Heo, S.D.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.2
    • /
    • pp.95-99
    • /
    • 2014
  • Binaural interaction can recognize the same intensity sound by stimulating two ears alternatively, and it can be record auditory brainstem responses (ABR). However, We needs to be researched about binaural interaction in asymmetric binaural acoustic stimulation. 17 normal young hearing university students were participated. Clicks were presented at the intensity of 90 dB nHL to one ear and the click intensity was increased from 0 to 90 dB nHL with a separation of 10 dB to another ear, simultaneous. BI waveform was obtained by subtracting the sum of the asymmetrically evoked potentials from the binaurally evoked potentials; i.e. BI = B - (L + R). Latency and amplitude was measured 'peak to following trough' of IV-V complex of BI waveform. Threshold of BIC (t-BIC) was obtained using amplitude depend on stimulus intensities (paired sample t-test). Latency shifted in 4.65, 4.63, 4.57, 4.58, 4.62, 4.6, 4.48, 4.36, 4.23 ms for peak, 5.57, 5.51, 5.51, 5.59, 5.61, 5.55, 5.44, 5.28, 5.19 ms for trough, and amplitude shifted in .0.32, -0.3, -0.34, -0.32, -0.42, -0.53, -0.54, -0.61, $-0.67{\mu}V$ from 0 to 90 dB nHL in every 10 dB, respectively. t-BIC was observed 40 dB nHL(p=.001).

  • PDF

Ability of Modified Glucomannan to Sequestrate T-2 Toxin in the Gastrointestinal Tract of Chicken

  • Reddy, N.B.;Devegowda, G.;Shashidhara, R.G.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.2
    • /
    • pp.259-262
    • /
    • 2004
  • The ability of Modified Glucomannan (MG) to bind T-2 toxin (T-2) in the gastrointestinal tract has been tested in vivo by feeding 120 five-wk-old broiler chicken with the following six treatment diets, 1) Control diet; 2) Control+MG (0.1%); 3) Control+T-2 (500 ppb); 4) Control+T-2 (500 ppb)+MG (0.1%); 5) Control+T-2 (1,000 ppb) and 6) Control+T-2 (1,000 ppb)+MG (0.1%). Twenty birds were assigned to each treatment group, which had five experimental groups. Four birds of each experimental group were sacrificed at an interval of 30 min i.e. at 0, 30, 60, 90 and 120 min after feeding experimental diets. The whole gut contents of each bird were collected, dried and toxin concentration was determined. Percent T-2 recovered from the gut was significantly lower (p<0.05) in the groups fed MG at all the time intervals. The percent T-2 adsorbed by the MG at different T-2 levels (500 and 1,000 ppb) was 15.97 and 14.77, 22.53 and 22.67, 26.88 and 28.03, and 31.50 and 31.83 at 30, 60, 90 and 120 min, respectively.

Evaluation the Feed Value of Whole Crop Rice Silage and Comparison of Rumen Fermentation according to Its Ratio (신규 조사료원 사료용 벼 사일리지의 사료가치 평가 및 급여 비율에 따른 반추위 발효성상 비교)

  • Park, Seol Hwa;Baek, Youl Chang;Lee, Seul;Kim, Byeong Hyeon;Ryu, Chae Hwa
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.40 no.4
    • /
    • pp.236-243
    • /
    • 2020
  • This study was to evaluate the feed value of whole crop rice silage (WCRS) and to investigate a suitable ratio of the WCRS and concentrate by an analysis of rumen fermentation. A total of 6 treatments were used according to WCRS: concentrate ratio on in vitro rumen fermentation: T1 (100:0), T2 (60:40), T3 (40:60), T4 (20:80), T5 (10:90), and T6 (0:100). The ruminal pH, total gas emission, ammonia nitrogen, and volatile fatty acid (VFA) were determined as fermentation parameters. Total nutrients digestibility trial was conducted by 4 treatments according to WCRS: concentrate ratio at 40:60 (W40), 20:80 (W20), and 10:90 (W10), respectively. Feed value was analyzed according to AOAC (2019) and nutrient digestibility was calculated based on NRC (2001). The levels of crude protein (CP), crude fat, and neutral detergent fiber of the WCRS were 12.29%, 1.67%, and 59.79%, respectively. It was found to be 51.49% as a result of predicting the total digestible nutrient of WCRS using the NRC (2001) model. In vitro rumen fermentation, T4, T5, and T6 treatments showed a greater gas emission and total VFA concentration compared with other treatments (p<0.05). Acetate and acetate to propionate ratio of T4, T5, and T6 were significantly higher than other treatments (p<0.05). There was a significant difference in the level of propionate and butyrate according to the WCRS: concentrate ratio (p<0.05). The digestibility of dry matter and CP was significantly lower in W40 than in other treatments (p<0.05); however, there was no difference in W20 and W10. In conclusion, the 20:80 (WCRS: concentrate) is beneficial for stabilizing the rumen that does not inhibit rumen fermentation and nutrient digestion. This ratio might have a positive effect on the economics of farms as a valuable feed.

Thermal Vibration Characteristics of a Thin Walled Composite Beam attached on Spacecraft (위성체에 장착된 얇은 벽 복합재 보의 열 진동 특성)

  • Kim, Gyu-Sun;Song, O-Seop
    • Composites Research
    • /
    • v.23 no.6
    • /
    • pp.47-54
    • /
    • 2010
  • Thermal vibration characteristics of a thin walled composite beam attached on spacecraft are investigated in this paper. The composite beam is assumed to have a thin CUS(circumferentially uniform stiffness) wall and modeled with several composite materials which are already space qualified such as T300/Epoxy, YS90AEpoxy. Steady state angle and peak to peak error in spacecraft attitude angle and tip displacement of composite beams are evaluated as a performance index for thermal vibration characteristics. Evaluation results shows that composite beam made out of YS90A has nearly 2 times better than T300 in terms of peak to peak attitude error angle.

Isolation and identification of β-glucosidase producing halophilic Roseivivax roseus (β-Glucosidase를 생성하는 호염성 Roseivivax roseus 균주의 분리 및 분류동정)

  • Cho, Geon-Yeong;Han, Song-Ih
    • Korean Journal of Microbiology
    • /
    • v.51 no.2
    • /
    • pp.141-147
    • /
    • 2015
  • Four halophilic bacteria were isolated from a salt water tank of more than 25% above salinity used for production of salt. HJS1 and HJS6 strains were identified as having ${\beta}$-glucosidase producing capabilities at high salinity. ${\beta}$-Glucosidase produced from these bacterial strains showed the best activity at 56-79 U/ml in NaCl (0-5%), showing the highest ${\beta}$-glucosidase activity at NaCl 3%. A salt tolerant ${\beta}$-glucosidase can maintain at least 75% activity of the enzyme in 0-20% NaCl concentration. The 16S rRNA gene sequences of strains HJS1 and HJS6 shows 99.8% similarity with Roseivivax roseus $BH87090^T$. Those sequences were registered as AB971835 and AB971836 in the NCBI GenBank. DNA-DNA hybridization test revealed that both strains showed 90.1 to 90.3% hybridization values with R. roseus $BH87090^T$, which was the closest phylogenetic neighbor. Major Cellular fatty acids of strains HJS1 and HJS6 were $C_{16:0}$, $C_{18:1}$ ${\omega}7c$, $C_{19:0}$ cyclo ${\omega}8c$ and 11-methyl $C_{18:1}$ and the major quinone was Q-10. Their fatty acid composition and quinone were very similar to Roseivivax roseus $BH87090^T$. Meanwhile, Roseivivax roseus $BH87090^T$ did not produce any ${\beta}$-glucosidase. Based on the molecular and chemotaxonomic properties, strains HJS1 and HJS6 were identified as members of Roseivivax roseus.

Importance of convection during physical vapor transport of Hg2Cl2 in the presence of Kr under environments of high gravitational accelerations

  • Kim, Geug-Tae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Special attention in the role of convection in vapor crystal growth has been paid since some single crystals under high gravity acceleration of $10g_0$ appear considerably larger than those under normal gravity acceleration ($1g_0$). With increasing the gravity acceleration from $1g_0$ up to $10g_0$, the total molar flux for ${\Delta}T$ = 30 K increases by a factor of 4, while for ${\Delta}T$ = 90, by a factor of 3. The maximum molar fluxes for three different gravity levels of $1g_0$, $4g_0$ and $10g_0$, appear approximately in the neighborhood of y = 0.5 cm, and the molar fluxes show asymmetrical patterns, which indicate the occurrence of either one single or more than one convective cell. As the gravitational level is enhanced form $1g_0$ up to $10g_0$, the intensity of convection is increased significantly through the maximum molar fluxes for ${\Delta}T$ = 30 K and 90 K. At $10g_0$, the maximum total molar flux is nearly invariant for for ${\Delta}T$ = 30 K and 90 K. The total molar flux increases with increasing the gravity acceleration, for $1g_0{\leq}g_y{\leq}10g_0$, and decreases with increasing the partial pressure of component B, a noble gas called as Kr (Krypton), $P_B$. The ${{\mid}U{\mid}}_{max}$ is directly proportional to the gravity acceleration for 20 Torr $P_B{\leq}300$ Torr. As the partial pressure of $P_B$ (Torr) decreases from 300 Torr to 20 Torr, the slopes of the ${{\mid}U{\mid}}_{max}s$ versus the gravity accelerations increase from 0.29 sec to 0.54 sec, i.e. by a factor of 2. The total molar flux of $Hg_2Cl_2$ is first order exponentially decayed with increasing the partial pressure of component B, $P_B$ (Torr) from 20 Torr up to 300 Torr.

The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera (NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구)

  • Oh, Joo-Young;Kang, Chun-Goo;Kim, Jung-Yul;Park, Hoon-Hee;Oh, Ki-Baek;Kim, Jae-Sam
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.291-297
    • /
    • 2013
  • This study is aimed to evaluate the effect of $T_{1/2}$ upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with $^{99m}TcO_4^-$ of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in $x^2$ test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of $T_{1/2}$ error from change of gradient with -0.25% to +0.25%, if $T_{1/2}$ is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see $T_{1/2}$ error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a tendency that count rate changes over time at this study, and we proved that it can effect $T_{1/2}$. And also, there is need of appropriate phantoms and the method of quality management like this study, because there are not any advice or limitation degrees for domestic medical purpose scintillation camera.