• Title/Summary/Keyword: TVOC

Search Result 153, Processing Time 0.031 seconds

Development of Filtering Sets Composed of Lignocellulosic Fiber-based 3-layers Fiberboard and Traditional Korean Paper for the Purification of Indoor and Outdoor Air Pollutants (리그노셀룰로오스 섬유-기반 3층 섬유판과 한지로 구성된 실내외 대기 오염물질 정화용 필터세트의 개발)

  • Young-kyu Lee;Yeong Seo Choi;Myoung cheol Moon;Jae min So;Ohkyung Kwon;Wonsil Choi;Joon weon Choi;In Yang
    • Korean Chemical Engineering Research
    • /
    • v.62 no.1
    • /
    • pp.87-98
    • /
    • 2024
  • This study was conducted to investigate the efficiency of the filtering sets composed of fiberboards, which were fabricated with lignocellulosic fiber and cork oak bark-based activated carbon (COA), as well as traditional Korean paper handmade from mulberry trees (KP) for the filtration of PM, TVOC and HCHO. Three-layers fiberboards (WRF) were fabricated with wood fiber in its surface layers and recycled fiber/COA in its core layer using a protein-based adhesive with the resin content of 8%. Filtering sets were composed of three WRF and one sheet of KP. Concentrations of PM, TVOC and HCHO generated with the combustion of a incense in a sealed laboratory hood were reduced efficiently with the operation of air-purifier installed the filtering sets. Except for the WRF fabricated with 4%/4% resin contents, other WRF were prepared with 5%/3% and 6%/2% resin contents in surface/core layers, and then the WRF were used with KP for the fabrication of filtering sets. Filtration efficiency of the filtering sets was improved as the core-layer resin content applied in the fabrication of WRF decreased. In addition, filtration efficiency of the WRF-based filtering set fabricated with KP of 25 g/m2 basis weight was higher than that with KP of 45 g/m2 basis weight. Filtering sets composed of three-layers fiberboards (RWF) that recycled fiber and wood fiber/COA were used in its surface and core layers, respectively, and KP-25g showed higher filtration efficiency than those of WRF-based filtering sets. Air-inhalation equipment installed the RWF-based, WRF-based filtering sets and without filtering set were operated in small indoor and large outdoor spaces. Efficiency for filtering PM and TVOC of the RWF-based filtering sets was higher than that of other filtering sets. It is concluded that fiberboard-based filtering sets composed of RWF and KP-25g can be used as a filter for reducing the concentrations of PM and TVOC existed in indoor and outdoor spaces.

Analysis on Characteristics and Related Factors of Indoor Air Quality in Newly Built Wooden Houses (신축목조주택의 실내공기질 특성 및 관련요인 분석)

  • Choi, Yoon-Jung;Lee, Jae-Kyung;Cha, Ye-Rang
    • Journal of the Korean housing association
    • /
    • v.26 no.4
    • /
    • pp.23-32
    • /
    • 2015
  • The purpose of this research is to analyze characteristics and related factors of IAQ (Indoor Air Quality) in newly built wooden houses by measuring pre and post occupancy. The subjects were five wooden houses which were built with similar materials and completed from July to December 2013. Measuring factors were TVOC, HCHO, PM10, $CO_2$, CO, indoor temperature, and relative humidity. As the result of pre occupancy measuring, the houses that revealed the lowest TVOC concentration or HCHO concentration were satisfied with "the standard for newly built apartment houses". Therefore, IAQ by the wooden structures is considered to be in good condition. However, in cases of partial value exceeded the standard, the reason is analyzed to be the materials of molding, wrapping doors, built-in closet, or kitchen furniture, etc. rather than structure materials. Most PM10 concentration level showed slightly below "the standard for occupied multi-use facilities". Remaining of construction dust was considered to be the reason. As the result of post occupancy measuring, every value except of one subject's TVOC concentration was lower than pre occupancy, explaining the importance of natural ventilation.

The Analysis on the VOCs Contents and Ozone Production Contribution of A Marine Paint in Korea (국내 선박용 도료의 VOCs 함량분포 및 오존생성기여도에 관한 연구)

  • Kim, Su Min;Lee, Young Soo;Kang, Kyoung Hee;Yoo, Kyung Seun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.569-576
    • /
    • 2014
  • In this research, a few paints in the shipyard were selected and analyzed for the component and ozone production in marine paint using TVOC and GC/FID, ozone generation index (MIR, POCP) to establish measures of $VOC_s$ effectively. The concentrations of TVOC ranged between approximately 300~400 g/L and 400~500 g/L, respectively and these showed 37% of whole. Our results indicated that the main constituents of marine paints were m,p,oxylene (49%), ethyl benzene (10%), toluene (8%) and 2-propanol (5%). It was also found that xylene concentration have relatively higher impact on ozone generation. The types of paints were also investigated for their potentials. The biggest contributor was the 1 Pack Finish paint. The rest is, in their contributing order, 1 Pack Finish paint, 2 pack Finish paint, Anti-fouling paint, 2 Pack A/C paint, Ballast paint and 1 Pack A/C paint.

A Study on the Indoor Air Pollutants Emission Characteristics by Composed Building Materials (건축자재 마감구성에 따른 실내공기오염물질 방출특성에 관한 연구)

  • Park, Jin-Chul;Rhee, Eon-Ku;Yu, Hyung-Ku
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.3-8
    • /
    • 2005
  • Building parts of Multi-Family Houses are consisted of several building material assembly. Therefore, after selecting building materials with test result of emission intensity and their feature, composed building materials are made equally with actual construction methods, and experimented emission intensity. 7 days after experiment, formaldehyde emission intensity appeared low in an order of Tile Wall, Wood Flooring, Wallpaper, Reum Flooring, Silk Wallpaper, and 20 days after experiment, TVOC emission intensity appeared low in an order of Tile Wall, Reum Flooring, Silk Wallpaper, Wood Flooring, Wallpaper. There was a clear difference in TVOC emission intensity according to kind of building materials. Composed building materials that weight per unit area is big and omission intensity is high, they effect continuously to indoor air because decrement is small.

  • PDF

Relevance between Total Volatile Organic Compound (TVOC) Exposure Level and Environmental Diseases Within Residential Environments (주거환경 내의 Total Volatile Organic Compounds (TVOC) 노출수준과 환경성질환과의 관련성)

  • Lee, Dong-Hyun;Chung, Jin-Do
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.3
    • /
    • pp.193-200
    • /
    • 2011
  • Objective: The purpose of this study is to compare and analyze the level of exposure to volatile organic compounds for different kinds of households in apartments or houses and analyze the relation between atopy-related symptoms and concentration of volatile organic compounds in order to improve indoor air quality and start to build a process to prevent environmental diseases. Method: From July 2010 to November 2010, TVOC concentration levels were measured and analyzed in 402 general households and 236 weak households, totalling 638 households. Residents were asked to fill out a survey on environmental disease. All resources were analyzed using SPSS 12.0 program. Result: In comparing the differences in concentration levels of volatile organic compounds for different types of households, including existing apartments and houses, the type of housing did not affect the concentration level of volatile organic compounds, but the relevance with skin trouble, diagnosed atopy, and atopy systems all had statistical similarities. Moreover, above-limit volatile organic compounds showed statistical relevance with amount of ventilation, time of construction, skin trouble, diagnosed atopy and atopy symptoms. Conclusion: The study concludes that as the time of construction recedes further into the past and as the amount of ventilation is higher, the exposure level to volatile organic compounds was lower and the group that were suffering from atopy symptoms had higher exposure to volatile organic compounds.

The Comparison of VOC Characteristics Emitted from Wood-based Panels Using GC/FID and GC/MS (GC/FID와 GC/MS 분석법에 의한 목질제품에서의 VOC 방출특성 비교)

  • Hwang, Yoon-Seo;Park, Hyun-Ju;Son, Youn-Suk;Kim, Jo-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.4
    • /
    • pp.436-442
    • /
    • 2011
  • In this study, the Total Volatile Organic Compounds (TVOC) emitted from wood-based panels were compared by two analytical methods using the GC/FID and the GC/MS. Japanese Larch, Yellow Poplar, Particle Board (PB) and Medium Density Fiberboard (MDF) were selected as target materials. Major compounds emitted from the panels were Toluene, ${\alpha}$-pinene, ${\beta}$-pinene and limonene. In case of TVOC using GC/FID method, MDF E2 (1,497 ${\mu}g/m^3$) revealed the highest concentration among all wood-based panels, while Japanese Larch (1,772 ${\mu}g/m^3$) showed the highest value with respect to GC/MS method. Furthermore, it was found that the amount of VOC emitted from panels was different depending upon analytical methods. This significant difference was attributed to analytical sensitivities of GC/FID and GC/MS for various VOC. Besides, it was found that the composition ratios of main VOC compounds were not significantly different.

Patterns of Offensive Odor Compounds According to Blocks in Shiwha Industrial Complex (시화산업단지의 블록 별 악취유발물질 특성)

  • Byeon, Sang-Hoon;Lee, Jung-Geun;Kim, Jung-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.12
    • /
    • pp.1161-1168
    • /
    • 2009
  • This research was conducted on characteristic of offensive odors in Shihwa industrial complex. Result of blocks distribution of TVOC indicates that mechanic block, site D, was the highest concentration (74 ppb). Chemistry block, site A, was the second highest concentration (50 ppb). Also, mixed blocks, metal blocks and park etc. were measured almost similar concentration about 30 ppb, but mixed block, site F, was the place where concentrations were the smallest. Average of TVOC was shown about 35 ppb concentration. Aldehydes including acetaldehyde, butyraldehyde and hydrogen sulfide concentrations were prevalent among offensive odors in Shihwa industrial complex. Comparing the offensive odor intensity mostly about acetaldehyde, butyraldehyde and hydrogen sulfide which contain high offensive odor intensity showed results that sites A, B (chemistry block) and site D, I (mechanic block) site H (metal block) have showed the intensity over 1. In the case of acetaldehyde, relatively the high odor intensities over '2' were able to obtain in many cases. The correlation coefficient (r) for hydrogen sulfide was 0.91, so that high positive correlation exists between offensive odor intensity and the hydrogen sulfide element. Butyraldehyde also showed high positive correlation coefficient, as 0.82. Correlation coefficient of acetaldehyde that had the highest value as offensive odor substance was 0.62, had somewhat correlation with offensive odor intensity.

Emission Characteristics of Volatile Oranic Compounds by Finishing Materials in a Newly Constructed Wooden House (신축목조주택 내 마감자재에 따른 휘발성유기화합물(VOCs)의 방산특성)

  • Lee, Hee-Young;Park, Sang-Bum;Park, Jong-Young;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.83-90
    • /
    • 2007
  • This study aimed at examining the effect of rooms decorated by eco-friendly finishing materials in a newly built wooden house on the emission of indoor air pollutions. According to the results of examination, the levels of benzene, toluene, ethyl benzene and styrene in all the rooms were below criteria of indoor air quality of newly-constructed houses. The levels of natural volatile organic compounds (NVOC), anthropogenic volatile organic compounds (AVOC) and total volatile organic compounds (TVOC) in room R1-1 which had Hwangto wall covering on it, were relatively higher than in room phytoncide wallpaper covered R2-1. The room R2-2 where bamboo charcoal panel used for wall covering showed higher level of AVOC compared to the room R1-2. Living room R1-3 was found to contain less TVOC, compared to the other four rooms. In addition, the ratio of NVOC to TVOC in the living room was higher than in the other rooms. This seemed to be attributed to Cryptomeria Japonica the living room finished material.

Characteristics of Volatile Organic Compounds Emitted in Building Materials and Their Predictions of Time-dependent Variation

  • Pang, Seung Ki;Sohn, Jang Yeul;Lee, Kwang Ho
    • Architectural research
    • /
    • v.7 no.1
    • /
    • pp.19-26
    • /
    • 2005
  • Unlike other countries, Korea uses various kinds of wall-paper as finishing material. Conventional wall-paper consists of paper and vinyl, and petrochemical ink is used for the decoration of the surface. Adhesive is used to paste the wall with the wall-paper, which emit substantial amounts of VOCs and formaldehyde. In this study, VOCs characteristics emitted from specimens made of concrete, mortar, gypsum board and wall-paper were investigated using small chamber method. Moreover, concentration and emission factor of BTEX(Benzene, Toluene, Ethylbenzene, m,p,o-Xylene) and TVOC were investigated, and concentration and emission factor decay were estimated. As a result of the prediction, both time-dependent concentration decay and cumulative concentration can be converted into the logarithmic scale. Furthermore, prediction equations were developed from the experimental results under accurately controlled experimental conditions. Therefore, there may be difference if the estimated equations are directly applied to real buildings. Further research should be done on the generalization of the developed prediction equations.

A study on the field measurement of the TVOC and HCHO concentration in the newly constructed apartment houses in spring seasons (입주전 신축공동주택의 봄철 TVOC, HCHO농도 실태조사에 관한 연구)

  • Choi, Seung-Hyuck;Kim, Keon-Woo;Lee, Jong-Sik;Park, Jin-Chul;Kim, Sin-Do
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.126-131
    • /
    • 2007
  • This study aims to present the fundamental strategies for improving the Indoor Air Quality(IAQ) in newly-constructed apartment buildings. To investigate the concentration of indoor air pollutants such as HCHO and VOCs and the field measurement were conducted. According to the field measurement of 60 new houses in spring season, the concentration of HCHO in about 20% were higher the IAQ standards.

  • PDF