• Title/Summary/Keyword: TRU analysis

Search Result 40, Processing Time 0.029 seconds

Physics analysis of new TRU recycling options using FCM and MOX fueled PWR assemblies

  • Cho, Ye Seul;Hong, Ser Gi
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.689-699
    • /
    • 2020
  • In this work, new multi-recycling options of TRU nuclides using PWR fuel assemblies comprised of MOX and FCM (Fully Ceramic Micro Encapsulated) fuels are suggested and neutronically analyzed. These options do not use a fully recycling of TRU but a partial recycling where TRUs from MOX fuels are recycled while the ones from FCM fuels are not recycled due to their high consumption rate resulted from high burnup. In particular, additional external TRU feed in MOX fuels for each cycle was considered to significantly increase the TRU consumption rate and the finally selected option is to use external TRU and enriched uranium feed as a makeup for the heavy metal consumption in MOX fuels. This hybrid external feeding of TRU and enriched uranium in MOX fuel was shown to be very effective in significantly increasing TRU consumption rate, maintaining long cycle length, and achieving negative void reactivity worth during recycling.

A case study for class improvement through online math class analysis and self-evaluation: Focusing on fair access, autonomy, initiative, and evaluation areas in the TRU analysis (온라인 수학 수업 분석 및 자기 평가를 통한 수업 개선 사례 연구: TRU 분석에서 공정한 접근, 자율성 및 주도성, 평가 영역을 중심으로)

  • Park, Mangoo;Kim, Ji Young;Kim, Minhwe;Yoon, Jong Chun;Lee, Jung Min
    • The Mathematical Education
    • /
    • v.61 no.1
    • /
    • pp.83-108
    • /
    • 2022
  • This research is a case study in which teachers tried to improve classes through online class analysis and self-evaluation in elementary school mathematics classes using a checklist of class reflection based on fair access, autonomy, initiative, and evaluation areas in the TRU analysis framework of Schoenfeld (2016). As a result, it was confirmed that the teacher's fair participation, student autonomy, initiative, feedback, and evaluation areas improved teaching methods during the short time. Therefore, if you want to improve classes in relatively short period of time, you can see the effect of some improvement only by self-evaluation. However, continuous improvement of teaching methods require the help of a teacher communities including experts or critical colleagues, and a longer-term case study.

A Study on the Separation of Long-lived Radionuclides and Rare Earth Elements by a Reductive Extraction Process (환원추출에 의한 장수명핵종과 희토류 원소의 분리 연구)

  • 권상운;안병길;김응호;유재형
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.421-425
    • /
    • 2003
  • The reductive extraction process is an important step to refine the TRU product from the electrorefining process for the preparation of transmutation reactor fuel. In this study, it was studied on the reductive extraction between the eutectic salt and Bi metal phases. The solutes were zirconium and the rare earth elements, where zirconium was used as a surrogate for the transuranic(TRU) elements. All the experiments were performed in a glove box filled with a argon gas. Li-Bi alloy was used as a reducing agent to reduce the high chemical activity of Li. The reductive extraction characteristics were examined using ICP, XRD and EPMA analysis. The reduction reaction was equilibrated within 3 hours after the Li addition. Three eutectic salt systems were compared and Zr was successfully separated from the rare earth elements in all the three salt systems.

  • PDF

Dynamic Modeling of a Partial Plutonium Recycling Scenario

  • Jeong, Chang-Joon;Ko, Won-Il
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.11a
    • /
    • pp.55-56
    • /
    • 2009
  • From the OT cycle analysis results, the nuclear power demand grows to ~70 GWe in 2150. The SF and TRU out-core inventories in 2150 will be 186500 t and 2100 t, respectively. The MOX fuel cycle gives 84% and 9% lower values for the SF and out-core TRU inventories, respectively.

  • PDF

Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature

  • Gundogar, Mustafa;Uslu, Gulsah;Ozyurek, Taha;Plotino, Gianluca
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.3
    • /
    • pp.37.1-37.8
    • /
    • 2020
  • Objectives: This study aims to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium (NiTi) rotary files at body temperature. Materials and Methods: In total, 80 VDW.ROTATE (25/0.04), TruNatomy (26/0.04), 2Shape (25/0.04), and HyFlex CM (25/0.04) NiTi rotary files (n = 20 in each group) were subjected to static cyclic fatigue testing at body temperature (37℃) in stainless-steel artificial canals prepared according to the size and taper of the instruments until fracture occurred. The number of cycles to fracture (NCF) was calculated, and the lengths of the fractured fragments were measured. The data were statistically analyzed using a 1-way analysis of variance and post hoc Tamhane tests at the 5% significance level (p < 0.05). Results: There were significant differences in the cyclic fatigue resistance among the groups (p < 0.05), with the highest to lowest NCF values of the files as follows: VDW.ROTATE, HyFlex CM, 2Shape, and TruNatomy. There was no significant difference in the lengths of the fractured fragments among the groups. The scanning electron microscope images of the files revealed typical characteristics of fracture due to cyclic fatigue. Conclusions: The VDW.ROTATE files had the highest cyclic fatigue resistance, and the TruNatomy and 2Shape files had the lowest cyclic fatigue resistance in artificial canals at body temperature.

Core design study of the Wielenga Innovation Static Salt Reactor (WISSR)

  • T. Wielenga;W.S. Yang;I. Khaleb
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.922-932
    • /
    • 2024
  • This paper presents the design features and preliminary design analysis results of the Wielenga Innovation Static Salt Reactor (WISSR). The WISSR incorporates features that make it both flexible and inherently safe. It is based on innovative technology that controls a nuclear reactor by moving molten salt fuel into or out of the core. The reactor is a low-pressure, fast spectrum transuranic (TRU) burner reactor. Inherent shutdown is achieved by a large negative reactivity feedback of the liquid fuel and by the expansion of fuel out of the core. The core is made of concentric, thin annular fuel chambers containing molten fuel salt. A molten salt coolant passes between the concentric fuel chambers to cool the core. The core has both fixed and variable volume fuel chambers. Pressure, applied by helium gas to fuel reservoirs below the core, pushes fuel out of a reservoir and up into a set of variable volume chambers. A control system monitors the density and temperature of the fuel throughout the core. Using NaCl-(TRU,U)Cl3 fuel and NaCl-KCl-MgCl2 coolant, a road-transportable compact WISSR core design was developed at a power level of 1250 MWt. Preliminary neutronics and thermal-hydraulics analyses demonstrate the technical feasibility of WISSR.

Shaping ability and apical debris extrusion after root canal preparation with rotary or reciprocating instruments: a micro-CT study

  • Emmanuel Joao Nogueira Leal da Silva;Sara Gomes de Moura;Carolina Oliveira de Lima;Ana Flavia Almeida Barbosa;Waleska Florentino Misael;Mariane Floriano Lopes Santos Lacerda;Luciana Moura Sassone
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.16.1-16.11
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the shaping ability of the TruShape and Reciproc Blue systems and the apical extrusion of debris after root canal instrumentation. The ProTaper Universal system was used as a reference for comparison. Materials and Methods: Thirty-three mandibular premolars with a single canal were scanned using micro-computed tomography and were matched into 3 groups (n = 11) according to the instrumentation system: TruShape, Reciproc Blue and ProTaper Universal. The teeth were accessed and mounted in an apparatus with agarose gel, which simulated apical resistance provided by the periapical tissue and enabled the collection of apically extruded debris. During root canal preparation, 2.5% sodium hypochlorite was used as an irrigant. The samples were scanned again after instrumentation. The percentage of unprepared area, removed dentin, and volume of apically extruded debris were analyzed. The data were analyzed using 1-way analysis of variance and the Tukey test for multiple comparisons at a 5% significance level. Results: No significant differences in the percentage of unprepared area were observed among the systems (p > 0.05). ProTaper Universal presented a higher percentage of dentin removal than the TruShape and Reciproc Blue systems (p < 0.05). The systems produced similar volumes of apically extruded debris (p > 0.05). Conclusions: All systems caused apically extruded debris, without any significant differences among them. TruShape, Reciproc Blue, and ProTaper Universal presented similar percentages of unprepared area after root canal instrumentation; however, ProTaper Universal was associated with higher dentin removal than the other systems.

Fissile Measurement in Various Types Using Nuclear Resonances

  • YongDeok Lee;Seong-Kyu Ahn
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.2
    • /
    • pp.235-246
    • /
    • 2023
  • Neutron resonance transmission technique was applied for assaying isotopic fissile materials produced in the pyro-process. In each process of the pyro-process, a different composition of the fissile material is produced. Simulation was basically performed on 235U and 239Pu assay for TRU-RE product, hull waste, and uranium addition. The resonance energies were evaluated for uranium and plutonium in the simulation, and the linearity in the detection response was examined on the fissile content variation. The linear resonance energies were determined for the analysis of 235U and 239Pu on the different fissile materials. For enriched TRU-RE assay, the sample condition was suggested; The sample density, content, and thickness are the key factors to obtain accurate fissile content. The detection signal is discriminated for uranium and plutonium in neutron resonance technique. The transmitted signal for fissile resonance has a direct relation with the content of fissile. The simulation results indicated that the neutron resonance technique is promising to analyze 235U and 239Pu for various types of the pyro-process material. An accurate fissile assay will contribute toward safeguarding the pyro-processing system.