• Title/Summary/Keyword: TRANSDUCER

Search Result 2,038, Processing Time 0.043 seconds

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Control of the Resonance Frequency of a Piezoelectric Transducer with Two Pair of Electodes - (어종식별을 위한 광대역 초음파 변환기의 설계 -I - 전극분할형 압전진동자의 주파수특성 제어 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.3
    • /
    • pp.183-188
    • /
    • 1997
  • A method for designing a broadband transducer was investigated experimentally. Control of the resonance frequency of a Piezoelectric circular transducer with two pairs of electrodes was achieved by varying the inductance of external coil connected across the terminal of one pair of electrodes of transducer. The conductance curves of transducer in water were obtained as a function of the inductance value in mH of the coil used in the tuning. As the tuning inductance is increased in value, the resonance frequency is reduced toward the fundamental frequency of 50 kHz. This interesting result suggest that it is possible to produce a continuously tunable transducer covering a frequency range between 61.3 kHz and 121.7 kHz by varying the inductance value of external coil from 2.7 mH to 15.0 mH. One of other problems in the design and construction of such broadband transducer is the transducer efficiency, but this will be the subject of our future work.

  • PDF

Design of High Efficiency Differential Electromagnetic Type Transducer for Implantable Middle Ear System (이식형 인공중이 시스템을 위한 고효율 차동 전자 트랜스듀서의 설계)

  • Song, Byung-Seop;Ro, Chul-Kyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.171-182
    • /
    • 2002
  • The differential electromagnetic transducer for IME(implantable middle ear) system, which have two small permanent magnets glued with the same pole facing each other in the coil, has high vibration efficiency and does not influenced by external magnetic field. In this paper, using finite element method, highly efficient structure of the transducer was proposed and vibration force of the transducer was calculated by electromagnetic theory. And the necessary vibration force of transducer to transmit the sound signal to inner ear when the transducer is attached at stapes was calculated and the design parameters of the transducer were investigated. Using the parameters, the differential electromagnetic transducer was manufactured in small size to implant in confined human middle ear. And it was examined by unloaded and loaded vibration experiment using temporal bone sampled from cadaver.

Optimal design of a concave annular array transducer to generate high intensity focused ultrasound (고강도 집속 초음파 발생용 오목한 환상형 배열 트랜스듀서의 최적설계)

  • Choi, Euna;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.452-465
    • /
    • 2016
  • In this study, the structure of a concave annular array transducer was optimized to generate high intensity focused ultrasound for medical therapeutic application. The transducer has a phased array structure composed of several concentric channels that have 40 mm as the radius of curvature. We derived theoretical equations to analyze the sound field of the transducer and verified the validity of the equations by comparing the results calculated by the equations with those from finite element analyses. We also checked the possibility of dynamic focusing at around the geometric focal point. Further, the level of a grating lobe occurring at an unwanted position in the transducer sound field was confirmed to be reducible through the relation between the number of channels and the frequency of the transducer. Hence, the structure of the transducer was optimized to place the main lobe within a specific range from the zenith while systematically reducing the level of the maximum sidelobe including the grating lobe. The designed structure showed the performance better than that targeted at all the focal points.

Identification of Guided-Wave Modes in Pipings of Power Plants by using Air-coupled Transducer (Air-coupled 트런스듀서를 이용한 발전설비 배관에서의 유도초음파 모드 규명)

  • Park, Ik-Keun;Kim, Hyun-Mook;Kim, Yong-Kwon;Song, Won-Joon;Cho, Yong-Sang;Jhang, Kyung-Young;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.341-347
    • /
    • 2004
  • In order to inspect the piping effectively, one of the important components in the facility of power plants, the ultrasonic guided wave was generated by a tomb transducer and was received in a non-contact fashion by using an air-coupled transducer. The guided wave modes that ran be generated by the comb transducer in piping are predicted from the theoretical dispersion curves and the element spacing of a comb transducer. Moreover, to receive the specific modes, the receiving angle of the air-coupled transducer is calculated from Snell's law between the phase velocities of guided waves and the sound velocity of air. The guided wave modes obtained in experiments are identified from the result of time-frequency analysis such as wavelet transform and two-dimensional fast Fourier transform.

A SAW filter fabrication of the series connected SPUDT type filter with bidirectional transducer filter (SPUDT와 양방향 변환기를 직렬 연결한 SAW 필터)

  • You, Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2374-2381
    • /
    • 2007
  • .We have studied to obtain the properly conditions about impedance matching of the SAW filter for the SPUDT type and the bidirectional transducer type later. And we have studied to obtain the SAW filter for the Slanted Finger Interdigital Transducer(SFIT), was formed on the Langasite substrate and was evaporated by Aluminum-Copper alloy and then we performed computer-simulated by simulator In case the SPUDT, we have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflector are $5000{\AA}$ and $3.6{\mu}m$, respectively. And the of the bidirectional transducer, the width of IDT' fingers and the space between IDT' finger and reflector is $1.8{\mu}m$, respectively. Also, we have performed to series connected the SPUDT type with the bidirectional transducer type filter. The frequency response of the fabricated SAW filter has the property that the center frequency is about 190MHz and bahdwidth at the 3dB is probably 5.3MHz after when we have matched impedance. Also, we could obtain that ripple characteristics is less than 0.3dB and insert loss is probably -20dB after when we have matched impedance.

Suggestion of an experimental method for optimization of flange point of a bolt-clamped Langevin-type ultrasonic transducer (볼트 체결형 란주반 초음파 트랜스듀서의 프렌지 포인트 최적화를 위한 실험적 방법 제안)

  • Kim, Jungsoon;Kim, Haeun;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.270-277
    • /
    • 2021
  • In the power ultrasound fields, the flange position for fixing the transducer is an important factor influencing on electro-mechanical efficiency of the transducer. We suggested a practical method that can determine the installation position of the flange for different resonance modes of the bolt-clamped type Langevin ultrasonic transducer. A semicircular wedge-shaped jig was manufactured and moved along the lateral surface of the transducer. The vibration characteristics were examined after a constant pressure was applied to the semicircular wedge-shaped jig. By observing the change of the input admittance of the transducer depending on the position of the pressure application, the optimum position for the flange installation could be determined. The resonant modes of the transducer were calculated by a Mason's equivalent circuit, and the particle velocity distribution for each resonance mode was calculated by a transmission line model. Since the optimum positions determined from an experimental result show a good correspondence with the node positions of the vibration modes calculated by the transmission line model, the validity of the suggested method was verified.

Biosensor의 원리와 응용

  • 김병홍
    • The Microorganisms and Industry
    • /
    • v.16 no.1
    • /
    • pp.28-39
    • /
    • 1990
  • Biosensor는 모든 종류에서 공히 생체물질로 이루어지는 감지 부분, transducer 그리고 전자부분으로 이루어진다. 따라서 Biosensor는 사용하는 생체물질, transducer로 그리고 측정되는 물질에 따라 분류된다. Biosensor에 이용될 수 있는 생물반응은 pH 변화, ion 생산및 소비, 기체생산및 소비, 발열, 발광, 전자전달, 질량변화 등을 들 수 있다. 이상의 반응을 유발하는 생체물질은 효소, 항체등 단백질과 세포, 조직등 다양하다. 여기에서는 transducer의 특징을 먼저 살펴보고 biosensor 각론에서 이들 생체물질의 반응 특징을 소개한다.

  • PDF

Optical Biosensors

  • Gang, Sin-Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.105-110
    • /
    • 2000
  • Biosensors consist principally of two basic components, receptor and transducer. The transducer part of the sensor serves the signal transfer from the output domain of the recognition system. Optical method of transducer have many benefits, based on phenomena like emission and absorption. This paper will review the methode of optical transduction in brief and out some new development.

  • PDF

A study on the Development of Transducer Detecting Infrasonic (초저주파를 검출하는 변환기의 개발에 대한 연구)

  • 이성백;김재환;강영창;이준웅
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.6 no.1
    • /
    • pp.45-50
    • /
    • 1981
  • Infrasonic transducer made with dielectric materials, such as polytetrafluoroethyleme(PTFE)film. The experimental result obtained that the response is within $\pm$1.5dB from 0.1Hz to 7KHz, and that sensitivities of typical transducer are fixed -60dB. The time constant of the transducer at room temperature is over 60 years, and the activation energy of the value of 1.1eV at 343K acquired. This transducer can have application to high-quality communication system, seismological observation etc.

  • PDF

Study on the Defect Detectability in Carbon Fiber Reinforced Plastic Sheet by the Ultrasonic Immersed Reflector Plate Method. (Ultrasonic Immersed Reflector Plate Mechod를 이용한 박판형 CFRP 소재의 결함탐지능에 관한 연구)

  • Lee, Jae-Ok;Lee, Se-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.6 no.1
    • /
    • pp.23-30
    • /
    • 1986
  • The optimumultrasonic test conditions for the thin carbon fiber reinforced plastic (CFRP) sheet were determined for the immersed reflector plate method. The effects of the water distance, the surface conditions of the specimen and transducer characteristics were studied. For a reliable test the water distance between the transducer and the front surface of the specimen should be determined when the beam profile of the transducer appears in the bell-shape. The detectability of the defect was improved as the effective beam width of the ultrasonic transducer became narrow. The transducer should be properly chosen considering to the surface condition of the test material as well as the size and type of the defect to be detected. It was possible to detect the flat bottom hole whose diameter is as small as about 500 micrometer.

  • PDF