• Title/Summary/Keyword: TRANSDUCER

Search Result 2,040, Processing Time 0.025 seconds

Experimental Verification of Implantable Middle Ear System using the Differential Electromagnetic Type Transducer (차동 전자 트랜스듀서를 이용한 이식형 인공중이 시스템의 실험적 검증)

  • 송병섭;이기찬;원철호;박세광;이상흔;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.217-225
    • /
    • 2002
  • The implantable middle ear(IME) system, which has good sound quality. superior sound intelligibility and wide frequency characteristics. can resolve the sound distortion and ringing effect by sound feedback at high gain operation those are the major problems of conventional hearing aid. In this paper, we have manufactured the IME system using differential electromagnetic transducer(DET) and verified the performance of the system by carrying out vibration and animal implanting experiment. The DET was manufactured using micro-machining technology and vibration experiment of the transducer was performed to inspect whether the transducer could vibrate in accordance with the applied sound signal or not. And the result of the loaded experiment using temporal bone sampled from cadaver showed that the transducer can drive the middle ear bone and transmit the signal to inner ear After the internal unit of IME system was implanted in a dog. the auditory brainstem response (ABR) test was carried out. The result of the test indicated the Proper behavior of the IME system in the living body From the results of the experiments, it is verified that the manufactured system ewll work well when it is applied to human and a basis of clinical experiment of IME system to real human hearing impaired was be arranged.

Measurement of transmitted vibration to stapes and tympanic membrane by DFMT's vibration in implantable middle ear hearing devices (중이 이식형 보청기에서 DFMT의 진동에 의한 등골 및 고막 방향으로 전달되는 진동력 측정)

  • Lee, Myoung-Won;Seong, Ki-Woong;Lim, Hyung-Gyu;Kim, Min-Woo;Jung, Eui-Sung;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Lee, Sang-Heun;Lee, Kyu-Yup;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.286-293
    • /
    • 2009
  • The implantable middle ear hearing devices(IMEHDs) have been developed to overcome the conventional hearing aid's problem(ringing effect caused by the acoustic feedback, cosmetic problem, etc.). In the IMEHDs, the vibrating transducer is a key component because its vibration enables to hear for hearing impaired people. The vibrating transducer is implanted on ossicular chain by surgical operation. The coupling status between implanted transducer and ossicular chain has an effect on delivering vibrating force from transducer to stapes. Noninvasive method is required to investigate the output characteristics of IMEHDs after implementation. Recently, emitted sound pressure measuring method of tympanic membrane is proposed to investigate the output characteristics of IMEHDs. However, the relationship between displacement of stapes and sound pressure by tympanic membrane was not cleared. In this paper, displacement of stapes and sound pressure by tympanic membrane were measured using the differential floating mass transducer(DFMT) that implanted on the ossicular chain of the human temporal bone and physical ear model. Through the experiments results, the relationship between displacement of stapes and sound pressure by tympanic membrane was investigated.

Design and output control technique of sonar transmitter considering impedance variation of underwater acoustic transducer (수중 음향 트랜스듀서의 임피던스 변화를 고려한 소나 송신기의 설계 및 출력 제어 기법)

  • Shin, Chang-Hyun;Lee, Yoon-Ho;Ahn, Byoung-Sun;Yoon, Hong-Woo;Kwon, Byung-Jin;Kim, Kyung-Seop;Lee, Jeong-Min
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.481-491
    • /
    • 2022
  • The active sonar transmission system consists of a transmitter that outputs an electrical signal and an underwater acoustic transducer that converts the amplified electrical signal into an acoustic signal. In general, the transmitter output characteristics are dependent on load impedance, and an underwater acoustic transducer, which is a transmitter load, has a characteristic that the electrical impedance varies largely according to frequency when driven. In such a variable impedance condition, the output of the active sonar transmission system may become unstable. Hence, this paper proposes a design and control technique of a sonar transmitter for transmitting a stable transmission signal even under variable impedance conditions of an underwater acoustic transducer in an active sonar transmission system. The electrical impedance characteristics of the underwater acoustic transducer are experimentally analyzed, and the sonar transmitter is composed of a single-phase full-bridge inverter, an LC filter, and a matching circuit. In this paper, the design and output control method of the sonar transmitter is proposed to protect the transmitter and transducer. It can secure stable output voltage characteristics even if it transmits the Linear Frequency Modulation (LFM) signal. The validity is verified through the simulation and the experiment.

Finite element analysis for acoustic and temperature characteristics of a piezoelectric HIFU transducer at 10 MHz (10 MHz용 압전 HIFU 트랜스듀서의 음향 및 온도 특성에 대한 유한요소해석)

  • Jong-Ho Kim;Il-Gok Hong;Ho-Yong Shin;Hyo-Jun Ahn;Jong-In Im
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.116-123
    • /
    • 2023
  • A high intensity focuses ultrasound (HIFU) is one of the emerging technologies in the biomedical field. The piezoelectric HIFU transducer is a device that utilizes the thermal energy generated by high ultrasound energy. Recently an operating frequency of the HIFU transducer is to expand above a 7 MHz. In this study, the acoustic pressures and temperature distributions in the tissue that generated by the HIFU transducer at 10 MHz were calculated with the finite element method. In addition, the pressure focusing characteristics of the device were analyzed. The geometrical variables are the piezomaterial thickness, lens shape, water height, and film thickness. The results shown that the acoustic pressure increased and saturated gradually when the height/radius (HL/RL) ratio of the lens increased. Moreover, the focal area was gradually decreases with HL/RL ratio of the lens. In case of the optimized HIFU transducer, the maximum pressure and temperature were analyzed about 19 MPa and 65℃ respectively. And the -3 dB focused distances in the axial and lateral direction are around 2.3 mm and 0.23 mm respectively.

Characterization of Component Materials of the Ultrasonic Transducer (초음파 탐촉자 구성 재료의 특성 연구)

  • Kim, B.G.;Park, Y.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.69-76
    • /
    • 1989
  • Piezoelectric elements, backing and shoe material are the important components of the ultrasonic transducer. In this study, characteristic constants in the domestic and the foreign PZT ceramic elements are investigated, The acoustic properties of the domestic and the foreign backing and shoes are characterized. The effects of components characteristics, the kinds of the piezoelectric elements and the thickness of the wear plates are investigated for the manufactured normal beam ultrasonic transducers.

  • PDF

Analytical Beam Field Modeling Applied to Transducer Optimization and Inspection Simulation in Ultrasonic Nondestructive Testing

  • Spies, Martin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.635-644
    • /
    • 2003
  • To ensure the reliability of ultrasonic nondestructive testing techniques for modern structural materials, the effects of anisotropy and inhomogeneity and the influence of non-planar component geometries on ultrasonic wave propagation have to be taken into account. In this article, fundamentals and applications of two analytical approaches to three-dimensional elastic beam field calculation are presented. Results for both isotropic materials including curved interfaces and for anisotropic media like composites are presented, covering field profiles for various types of transducers and the modeling of time-dependent rf-signals.

광간섭법을 이용한 절대높이 측정 정밀도 향상에 관한 연구

  • 안근식;장경영;문희관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.493-498
    • /
    • 1993
  • This paper proposes a high precision measurement technique to obtain the height of gage block. The proposed technique is consisted of two steps : In the first step, laser position transducer and electric micrometer are adopted to obtain a coarse value of the height of gage block, and then, second, heterodyne laser interferometry is adopted to acquire the precision value. The experiment results show that accuract in the order of a few nanometer is achieved for the gage blacks of as high as a few millimeter.

  • PDF

Selection of Piezoelectric Materials for Ultrasonic Transudcers (초음파 센서를 위한 압전 세라믹 선택)

  • 노용래
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1992.06a
    • /
    • pp.107-110
    • /
    • 1992
  • We investigate the influence of individual properties of piezoceramics such as elastic, dielectric, piezoelectric constants, and the coupling factor on the performance of the transducer operating in thickness mode oscillation. The investigation employs equivalent circuit analysis techniques. Appropriate transfer functions are obtained and discussed which suggest optimum selection guides of piezoelectric ceramics for each purpose, i.e. a transmitter, a receiver, and a pulse-echo transducer. The guides can help ceramic scientists find the direction to proceed in new material development.

  • PDF

On the Calibration of Impact Hammer Sensitivity (충격 해머의 感度補正)

  • 한상보
    • Journal of KSNVE
    • /
    • v.1 no.2
    • /
    • pp.115-120
    • /
    • 1991
  • The impact hammer is extensively used in experimental modal analysis as a means to provide force over a broad range of frequencies. The hammer mass and the impact head are often changed to achieve a desired impact time duration with its corresponding input frequency spectrum, these mass changes affect the performance and sensitivity of the force transducer employed to measure the impact force. Both a mathematical model describing the effects of impact head and hammer mass on the performance of the force transducer and experimental verification of this model are presented here.

  • PDF