• Title/Summary/Keyword: TRANSDUCER

Search Result 2,040, Processing Time 0.029 seconds

New High-efficiency Power Amplifier System for High-directional Piezoelectric Transducer (고지향성 압전 트랜스듀서용 새로운 고효율 전력 증폭기)

  • Kim, Jin-Young;Kim, In-Dong;Moon, Wonkyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.383-390
    • /
    • 2018
  • Piezoelectric micro-machined ultrasonic transducers for highly directional speaker need DC bias voltage. Most existing power amplifiers are not suitable for use in highly directional transducers because they are based on AC. In addition, since the piezoelectric micro-machined ultrasonic transducer has a large capacitive reactance, the power efficiency of the power amplifier is very low. Thus this paper proposes a new high efficiency power amplifier with DC bias voltage. In addition, by designing a matching circuit to compensate the capacitive reactance of the micro-machined ultrasonic transducer, the power efficiency of the power amplifier increases. The operating characteristics of the proposed power amplifier was verified by an experimental prototype. The proposed power amplifier is expected to be widely used in designing and implementing other related power amplifiers.

Design of High Efficiency Underwater Power Amplifier for Parametric Array Transducer (Parametric Array Transducer를 위한 고효율 수중전력증폭기의 설계)

  • Shim, Jae-Hyeok;Kim, In-Dong;Nho, Eui-Cheol;Moon, Won-Kyu;Kim, Won-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.29-30
    • /
    • 2013
  • 본 논문에서는 수중통신용 Parametric Array Transducer를 구동하기 위한 고효율 전력증폭기를 제안한다. 수중전력증폭기는 증폭부와 전원부로 나뉘며 증폭부는 Class B push-pull type의 전력증폭기를 사용하며 전력증폭기 구동을 위한 전원부는 기존의 일정전압이 아닌 가변전압을 얻는 Phase-shifted PWM AC/DC 컨버터를 사용하여 고효율로 동작한다. 증폭부는 Class B push-pull type 증폭기를 사용함으로써 뛰어난 선형성이 보장되며 전원 또한 ET(Envelope Tracking)기술을 적용한 가변전압 AC/DC컨버터를 사용하여 고효율로 동작한다. 본 논문에서는 고 효율 수중전력증폭기와 가변전압 AC/DC컨버터의 전력회로를 제시하고 시뮬레이션과 실험을 통하여 특성을 확인하였으며, 수중음향센서를 위한 전력증폭기로 유용하게 사용 될 것을 예상한다.

  • PDF

Electrical properties of ZnO/sapphire piezo-electric transducer by RF magnetron sputtering (RF magnetron sputtering으로 제작한 ZnO/sapphire 압전 변환기의 전기적인 특성에 관한 연구)

  • 이종덕;정규원;고상춘;송준태
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.22-25
    • /
    • 1995
  • In this paper, the physical characteristics of piezoelectric transducer which generates acoustic weve at microwave frequency were theoretically analized. We found that increasing electrode thickness is showed large distorthion on bandwidth. ZnO thin film were desposited by RF magnetron sputtering method. considering the sputtering parameters. Thickness of the desposited ZnO was 3.9 $\mu\textrm{m}$. In this experiment, we get that resistivity is 12.196${\times}$109 [cm$\Omega$], that resonance frequency is 827.47MHz Measuring insertion loss, we ascertained to possibility of transducer application for microwave frequency.

  • PDF

A Dual Mode Ultrasonic Transducer with a PZT Piezoelectric Seramics (PZT 압전 세라믹스를 사용한 2 중 모우드 초음파 변환기)

  • 김연보;노용래;남효덕
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.1-4
    • /
    • 1995
  • The most of conventional ultrasonic transducers are constructed to generate either longitudinal or shear waves, but not both of them. We investigated the mechanism of dual mode transducers that generates both of the longitudinal and shear waves simultaneously with a single PZT element. The study has been aimed to find the desired cut by the examining the piezoelectric properties. Theory predicts that a mixed P/S mode transducer can be constructed using a related Z-cut of a PZT ceramics. We studied the performance of a PZT element as a function of its rotation angle so that its efficiency is optimized to excite the two waves equally strongly. The results are verified by checking the impedance variation of the element with Finite Element Methods, and chocking the wave form by pulse-echo test simulation. Based upon the theory a rotated Z-cut was prepared and a transducer were fabricated. Validity of the theory calculation is verified through the

  • PDF

The Development of Ultrasonic Transducer for Measurement of Urine Volume in Incontinence Preventive System (뇨실금 방지 시스템에서의 뇨량 측정을 위한 초음파 변환기의 개발)

  • Choi, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.5 s.305
    • /
    • pp.35-42
    • /
    • 2005
  • In this study, we designed and developed an ultrasonic transducer which can measure urine volume based on the estimation of distance between the interior-wall and posterior-wall of bladder. Measurement of urine volume is a way to help patients with urinary incontinence by detecting the amount of urine before the urine is released from the bladder. With the results of this experiment, we can measure the urine volume more accurately and also develop an incontinence preventive system. This study can help patients with urinary incontinence and enuresis to live longer, healthier lives.

Development of Calibration System for Contact Transducer (초음파 탐촉자의 교정 시스템 개발)

  • Nam, Y.H.;Seong, U.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.294-299
    • /
    • 1999
  • In this paper, the calibration system for contact transducer has been developed to improve the reliability of the inspection result of ultrasonic testing on rotors. This system consists of signal processing parts: (oscilloscope, spectrum analyzer, pulser/receiver), standard block, and user interface program. Signal processing for the calibration system was performed quickly with high accuracy. The developed system has been applied to a practical calibration of probe using the non-destructive testing on rotors, and demonstrated high sensitivity and precision.

  • PDF

Tire Inflation Pressures Effects on 3 Directional Contact Pressures Between Soil and Undertread for a Tractor Tire (타이어 공기압이 언더트레이드면의 3방향 접지압에 미치는 영향)

  • 전형규;이규승
    • Journal of Biosystems Engineering
    • /
    • v.26 no.2
    • /
    • pp.123-130
    • /
    • 2001
  • The research described in this paper was aimed toward improving the understanding of the interaction of tire inflation pressure and the soil-tire interface stresses. A three-directional stress transducer was developed to measure stress distribution on undertread for a tractor tire. The transducer can directly measure three-directional stresses (normal stress, tangental stress and lateral stress and lateral stress) simultaneously and has both strong structure and high sensitivity, which is not changed by the abrasion of the detecting plate. Measurements of soil-undertread interface stresses were made at tire center on undertread on a 12.4-R24 radial tractor tire opeated at three combinations of a dynamic load (11.8kN) and three inflation pressures (59kPa, 108kPa and 157kPa). These measurements showed that as inflation pressure increased, the soil-undertread interface stresses increased. The results of three stresses comparisons were shown that the peak normal stresses were considerably higher than the tangential peak stresses and the peak lateral stresses.

  • PDF

A Study on the Wet Type Ultrasonic Flow-meter System Development (습식방식의 초음파 유량계 시스템 개발에 관한 연구)

  • Lee Eung-Suk;Kwon Oh-Hoon;Rho Myung-Hwan;Lee Hyung-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1638-1644
    • /
    • 2005
  • This paper suggests fur the study on a fluid velocity measuring system using ultrasonic transducer. In general, the time difference method to measure the distance between transducers has been known. In this paper, the practical technology for manufacturing ultrasonic flow meter system is studied using the time difference method. The ultrasonic transducer was designed and manufactured. The transmission and receiving algorithm for ultrasonic signal was studied. The ultrasonic flow measuring system was experimented in laboratory using a water reservoir for verifying the distance measuring accuracy. Finally, it was tested in flow calibration laboratory for the velocity measuring performance. The system, designed in this study, showed 0.3 mm resolution in distance measurement. For precise flow measurement, a high speed triggering algorithm is required for ultrasonic signal receiving.

Phantom Evaluation and Development of Photoacoustic Tomography Imaging System using Unfocused Ultrasound Transducer and Back-Projection Algorithm (역투사 알고리듬과 비촛점 트랜스듀서를 적용한 광음향 단층영상 장치개발과 팬텀실험)

  • Ryu, Sang-Hun;Kim, Do-Hyun;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2349-2351
    • /
    • 2010
  • Photo Acoustic Tomography (PAT) is a hybrid imaging modality which combines high contrast of optical imaging and spatial resolution of ultrasound imaging, thus it is suitable to image biological tissue noninvasively. Laser-induced photoacoustic signals were measured from a sample by means of an unfocused ultrasound transducer, then PAT image was reconstructed based on a universal back-projection algorithm. To evaluate the feasibility of our system, phantom test was performed, consequently, the PAT images obtained using our system showed highly analogous shape and volume with those of the phantom. This result demonstrated that our system can provide a powerful tool for imaging the substructure of biological tissue in non-invasive manner.

Characteristics of a $PbTiO_{3}$ Transmitting/P(VDF-TrFE) Receiving Ultrasonic Transducer in VHF Band

  • Ha Kang-Lyeol;Kim Moo-Joon;Kim Jung-Ho;Kim Jung-Soon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.311-314
    • /
    • 2004
  • A new type of high frequency wideband ultrasonic transducer with a separation between a transmitter and a receiver was proposed and its characteristics were simulated using the PSpice model. The piezoelectric ceramic $PbTiO_{3}$ as a transmitter and the piezoelectric copolymer P(VDF-TrFE) as a receiver were used for high sensitivity and wide bandwidth, respectively. The characteristics of a center frequency approximately 40MHz focusing transducer fabricated in this study showed very wide bandwidth which could give an axial spatial resolution better than 30um in the B-mode image for biological tissues.

  • PDF