• Title/Summary/Keyword: TRANSDUCER

Search Result 2,043, Processing Time 0.028 seconds

Optimal Design of a MEMS-type Piezoelectric Microphone (MEMS 구조 압전 마이크로폰의 최적구조 설계)

  • Kwon, Min-Hyeong;Ra, Yong-Ho;Jeon, Dae-Woo;Lee, Young-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.269-274
    • /
    • 2018
  • High-sensitivity signal-to-noise ratio (SNR) microphones are essentially required for a broad range of automatic speech recognition applications. Piezoelectric microphones have several advantages compared to conventional capacitor microphones including high stiffness and high SNR. In this study, we designed a new piezoelectric membrane structure by using the finite elements method (FEM) and an optimization technique to improve the sensitivity of the transducer, which has a high-quality AlN piezoelectric thin film. The simulation demonstrated that the sensitivity critically depends on the inner radius of the top electrode, the outer radius of the membrane, and the thickness of the piezoelectric film in the microphone. The optimized piezoelectric transducer structure showed a much higher sensitivity than that of the conventional piezoelectric transducer structure. This study provides a visible path to realize micro-scale high-sensitivity piezoelectric microphones that have a simple manufacturing process, wide range of frequency and low DC bias voltage.

Experimental Study for Defects Inspection of CFRP Using Laser-Generated Ultrasound

  • Lee, Joon-Hyun;Park, Won-Su;Byun, Joon-Hyung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.41-45
    • /
    • 2006
  • The fabrication process of fiber placement system of carbon fiber reinforced plastic (CFRP) requires real time process control and reliable inspection to ensure quality by preventing defects such as delamination and void. Therefore, novel non-contact inspection technique is required during the non-destructive evaluation in a fiber placement system. For the inspection of delamination in CFRP, various methods to receive laser-generated ultrasound were applied by using piezoelectric transducer, air-coupled transducer, wavelet transform and scanning laser ultrasonic technique. Laser-generated ultrasound was received with a conventional piezoelectric sensor in contacting manner. Then signal characteristics due to defects were analyzed to find a factor for detecting defects. Air-coupled transducer was used for reception of laser-generated guided wave using linear slit array in order to generate high frequency guided wave. And line scan technique was used to confirm the capability of on-line application. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer. The first peak of the frequency spectrum under 100kHz in the delamination region is higher than in the sound region. By using this feature, the line scanned frequency data were acquired in fully non-contact generation and reception of ultrasound. This method was proved as useful technique for detecting delamination in CFRP.

  • PDF

Optimal Design and Analysis of a Class IV Flextensional Transducer (Class Flextensional 트랜스듀서의 최적설계 및 특성해석)

  • 강국진;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.69-76
    • /
    • 2000
  • In this research, with the FEM we analyzed the variation of the sound pressure and thermal distribution of a Class IV Flextensional transducer in relation to its material properties and structures. Based on the results, we determined optimal structure of a Class IV Flextensional transducer that had maximum sound pressure, minimum thermal distribution, and 1 kHz resonance frequency. The sound pressure by the optimal structure is higher than that of the basic structure by two times, and the thermal distribution is much lower. Results of the present work can be utilized to design Class IV Flextensional transducers of various resonance frequency, maximum sound pressure, and minimum thermal distribution.

  • PDF

Miniaturization of disposable functional flow tube (기능성 일회용 호흡관의 소형화 연구)

  • Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.250-257
    • /
    • 2005
  • Respiratory tubes with the length of 35 mm and the diameter of 10, 15, and 20 mm were made and both the static($P_{S}$) and dynamic($P_{D}$) pressures were measured for steady flow rates ranging 1-12 l/sec. Regression analysis resulted successful fitting of $P_{S}$ and $P_{D}$ data with quadratic equations with correlation coefficients higher than 0.99. The measurement standards of the American Thoracic Society (ATS) were applied to $P_{S}$ data, which demonstrated the smallest tube diameter of 15 mm to satisfy the ATS standards. The maximum $P_{D}$ value of the velocity type transducer with the diameter of 15 mm was estimated to be 75 cm$H_{2}O$, implying approximately 7 times larger sensitivity than the widely used pneumotachometer. These results showed that the velocity type respiratory air flow transducer is a unique device accomplishing miniaturization with the sensitivity increased, thus would be of great advantage to develop portable devices.

Design Criteria to Miniaturize the Single Use Functional Respiratory Air Flow Tube

  • Kim Kyung Ah;Lee Tae Soo;Cha Eun Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2005
  • Respiratory tubes with a length of 35mm and diameters of 10, 15, and 20mm were made for experimental purpose, and both the static$(P_s)\;and\;dynamic(P_D)$ pressures were simultaneously measured for steady flow rates ranging 1-12//sec. Least squares analysis resulted successful fitting of $P_s\;and\;P_D$ data with quadratic equations with correlation coefficients higher than 0.99(P<0.0001). The spirometric measurement standards of the American Thoracic Society(ATS) were applied to $P_s$ data, which demonstrated the smallest tube diameter of 15mm to satisfy the ATS standards. The maximum $P_D$ value of the velocity type transducer(the functional single use respiratory air flow tube) with the diameter of 15mm was estimated to be approximately $75cmH_2O$, implying more than 7 times larger sensitivity than the widely used pneumotachometers. These results showed that the velocity type respiratory air flow transducer is a unique device accomplishing miniaturization with the sensitivity increased, thus would be of great advantage to develop portable medical devices.

Effects of Ship`s Roll Motion on the Detectable Area of Echo Sounder (선체의 횡요와 어군탐지기의 탐지기능범위에 관하여)

  • Park, Jung-Hee;Sin, Hyeong-Il;Lee, Dae-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.2
    • /
    • pp.93-98
    • /
    • 1983
  • When detecting underwater targets using echo sounder, the echo signals varies with the angular displacement of the transducer due to ship's motion. Then, the effect of the angular which effects the capability of the echo sounder must be investigated in relation to the detection of fish concentration, particularly, the abundance estimation of fish. In this pater, as the basic research to investigate the effect of the ship's motion when estimating the fish stocks by acoustic methods, the authors was theoritically considered the variations in the values of the two way directivity function of transducer in the direction of the targets which caused by the angular motion of transducer. Here, the effects of the movement of target and ship's running are neglected. At the same time, the data was applied to estimate the angular shift of the detectable area of echo sounder due to transducer displacement. From the results analyzed, we found that the angular shift of the detectable area due to ship's motion increases both as the roll angle increases and as the beamwidth becomes narrower, varies with the depth.

  • PDF

Power Factor Compensation for Wideband Acoustic Projector Using Measurement Data and ABCD matrix (ABCD 전송 파라메터를 사용한 광대역 음향 발신기의 역률 개선 연구)

  • Lim, Jun-Seok;Pyeon, Yong-Guk
    • 전자공학회논문지 IE
    • /
    • v.48 no.3
    • /
    • pp.10-15
    • /
    • 2011
  • In the case of designing an acoustic transducer for high power application, we usually aim to transfer the source electric energy to the output acoustic energy as large as possible. For this purpose, we should match the impedance of the power amplifier to the impedance combined with the acoustic transducer impedance and the radiation impedance. Especially if we have electrical source with almost zero impedance, we need improve the power factor of the acoustic transducer in the load. In this paper, we propose a broad band impedance matching method by the improvement of power factor, which applies ABCD matrix.

Pulse-echo response of ultrasonic transducer fabricated with PZT-polymer 3-3 type composite (PZT-고분자 3-3형 복합압전체 소자로 제작된 초음파 트랜스듀서의 펄스에코 응답특성)

  • 박정학;최헌일;손무현;사공건
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1053-1059
    • /
    • 1996
  • The pulse-echo response of the piezoceramics PZT-polymer 3-3 type composite transducers with various PVA additions were investigated. The PZT powder was prepared by the molten salt synthesis method. The porous PZT specimens will be used as a filler to make 3-3 type comosite were prepared from a mixture of PZT and polyvinylalcohol(PVA) sphere by utilizing BURPS(Bumout Plastic Sphere) technique. It was shown that the transmitting and receiving sensitivity of 3-3 type piezoelectric composite transducers could be improved than that of solid PZT transducers. The reason is that 3-3 type piezoelectric composite have low dielectric constant, density and acoustic impedance. The distance between transducer and reflector was in good agreement with the distance calculated from the longitudinal velocity of the specimens and receiving time observed pulse-echo responses on the ultrasonic transducer analyzer.

  • PDF

Properties of PZT Ultrasonic Transducer Array Fabricated by Micro-Pressing and Dicing method (Micro-Pressing 방법과 Dicing 방법에 의해 제조된 PZT Ultrasonic Transducer Array의 특성)

  • Park, Joon-Shik;Hong, Sung-Jei;Cho, Jin-Woo;Park, Soon-Sup;Han, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2248-2250
    • /
    • 2000
  • We investigated properties of PZT composite for medical ultrasonic transducer array (briefly UTA) for medicine applications fabricated by micro pressing and dicing method. Dicing method was the fabrication process of conventional ultrasonic transducer array by dicing sintered PZT sheet. Micro pressing method was the proposed process using pressing PZT green sheet by PMMA micro mold from LIGA process. Microstructures, electrical and electro -mechanical properties of fabricated UTAs of two cases were analyzed. Thickness mode electro-mechanical coupling coefficient of two cases have same values of 51%. Sintered PZT Microstructures of them showed dense and uniform. Micro pressing method was very mass productive process because of using batch type LIGA process. From results, we found micro pressing method was more competitive than dicing method for UTA fabrication. For further study, uniformity of microstructures and electro-mechanical properties of large scale, and fabrication processes of Ni plating and PMMA molding should be improved and investigated.

  • PDF

Design of a Ka-Band Orthomode Transducer (Ka-대역 직교모드변환기 설계)

  • 이종경;채범용;박동희;안병철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.1
    • /
    • pp.110-118
    • /
    • 2004
  • In this paper, a method is presented for the design of an orthomode transducer(OMT) operating at 21/31GHz frequency bands. A square waveguide is used in the common port while the WR-34 standard rectangular waveguide is used in the straight port. The straight port is connected to the common port via a multi-stage quarter-wave impedance transformer. The side port is coupled to the common port through a slot formed along the center line of the common square waveguide. An impedance transformer is employed to match the impedance of the coupling slot with that of the WR-51 waveguide at the output of the side port. Dimensions of the OMT are iteratively optimized employing the theory of waveguide. The validity of the proposed method is verified by fabricating and testing the designed orthomode transducer.