Calibration of Acceleration Plant and Test Rig Design to Dynamic Fracture (동적 파괴에 대한 가속장치의 보정 및 시험장치 설계)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.3
    • /
    • pp.47-52
    • /
    • 2008
  • The force transducer in the acceleration plant due to dynamic fracture is calibrated by dynamically using the stress pulses from a longitudinal bar. The bar is supported by two strings attached to the ceiling. The bar velocities before and after impact are measured and a full bridge at bar and transducer is formed by the four strain gauges. A transient recorder is used to store the stress pulse signals of force transducer and bar. For the first test series, three point bend test specimens can be chosen by means of test rig design and the inspection as sample experiment in this presented paper is sufficient for proving with the numerical simulation of the specimen model.

A Study on the Level Limit Switch for Measuring Near-distance Variation with 1-3 Type Ceramic/Polymer Composite Ultrasonic Transducer (1-3형 복합압전체 초음파 트랜스듀서를 사용한 근접거리변동 측정용 레벨 Limit스위치에 관한 연구)

  • Kim, H.G.;Park, K.I.;Shin, K.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.103-106
    • /
    • 2003
  • In this study, an ultrasonic transducer is fabricated with 1-3 type composite resonators. Pulse-echo responses of an ultrasonic transducer are investigated in underwater dependent on the variable designated water-level. LED Output signals of a level limit with changing a water level is obtained by the 1-3 type self-made composite transducer and electric measuring unit. LED is turned on at above the up-limit level with increasing a water level, and LED is turned on at less than the down-limit level with decreasing a water level. There was good agreement between the virtual water level and output LED signal by using the self-made water-detecting system.

  • PDF

Electrical Properties of a Three-layered Piezoelectric Ceramic Transducer (3중 적층형 압전 세라믹 트랜스듀서의 전기적 특성)

  • Lee, Sang-Churl;Jeong, Young-Woo;Yu, Young-Han;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1283-1285
    • /
    • 1994
  • A three-layered piezoelectric ceramic transducer is fabricated with three piezoelectric ceramic disk transducers and two sheets of thin insulator. Its equvalent circuit is derived from the Mason's model of a thickness-driven piezoelectric transducer. We applied the electric input near its fundamental resonant frequency to the center transducer and connect the output voltages across the left and right transducers in series to the resistor load. Then we investigate the load characteristics at resonant frequencies under various resistor loads and the frequency characteristics near the resonant frequency under no load. Moreover, symbolic expressions for input impedances, voltage ratios, resonant frequencies, and bandwidths have been derived. The values calculated from those symbolic expressions are shown to agree well with the measurement values.

  • PDF

Development of a Ultrasound Probe for 3-D Ultrasonic Imaging (3차원 의료기기용 초음파진단기 프로브 개발)

  • Park, Jong-Soo;Kim, Seong-Rae;Nam, Yoon-Su
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.87-93
    • /
    • 2005
  • Three-dimensional ultrasonic probes being applied to the medical imaging can be grouped into three depending on the scanning methods, which are a mechanical type system, a free-hand system, and 2D phased arrays system. A mechanical type scanner uses a mechanically driven transducer to acquire series of 2D plane images. By integrating these images, a 3-D medical image can be constructed. A motor driving mechanism is a conventional choice for mechanically driving a transducer assembly which picks the raw ultrasonic images up. In this paper we attempt to design a 3D ultrasonic probe which has a operating mechanism of s tilting 3-D scanning. The motion of a transducer assembly of the ultrasonic probe is analytically modelled. We propose a selection procedure for the diameter of a wire rope driving the transducer assembly and the size of torsional spring which gives an initial tension to wire ropes.

  • PDF

A Study on The Driving Characteristics of Ultrasonic Linear Motor Using Symmetric And Anti-Symmetirc Resonance Modes (대칭-비대칭 공진모드를 이용한 초음파 리니어 모터의 구동특성 연구)

  • Choi, Myeong-Il;Bae, Seok-Myeong;Park, Tae-Gone
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1962-1966
    • /
    • 2007
  • Transducer for ultrasonic linear motor with the symmetric and anti-symmetric modes was studied. The ultrasonic linear motor consists of two Langevin type piezoelectric vibrators that cross at right angles with each other in tip. In order to excite symmetric and anti-symmetric resonance modes, the transducer must have a phase shift of 90 degree in space and time. Therefore, the tip of transducer moves on an elliptical motion. In this paper, the finite element analysis was used to optimize dimension and displacement of the transducer. The ultrasonic motor was fabricated using the simulated result and the driving characteristics were measured. No-load velocity was 0.28[m/s] and the maximum efficiency was 30[%] in resonance frequency.

Design and FEA of Ultrasonic Linear Motor Using Two Langevin Piezoelectirc Vibrator (2개의 란쥬반형 압전 진동자를 이용한 초음파 리니어 모터의 설계와 유한요소해석)

  • 최명일;박태곤;정현호;이재형;정영호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.8
    • /
    • pp.669-675
    • /
    • 2003
  • Transducer for ultrasonic linear motor with symmetric and anti- symmetric modes was studied. The ultrasonic linear motor consists of two Langevin type piezoelectric vibrators that cross at right angles with each other in tip. In order to excite symmetric and anti-symmetric modes, the transducer must have a phase shift of 90 degree in space and time. As a result, the tip of transducer moves on an elliptical motion. In this paper, the finite element analysis was used to optimize dimension and displacement of the transducer.

Electromagnetic Vibration Transducer Using Silicon Elastic Body For Implantable Middle Ear Hearing Aid Applications (이식형 중이 보청기에 적용 가능한 Si 탄성체로 구현된 전자기 진동 트랜스듀서)

  • Lee, Ki-Chan;Lee, Se-Kyu;Park, Se-Kwang;Cho, Jin-Ho;Lee, Sang-Heun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.10
    • /
    • pp.583-588
    • /
    • 2000
  • This paper presents the design and fabrication of micro electromagnetic vibration silicon elastic body characterized with small size, high efficiency and selective frequency bandwidth for Bio-MENS applications, such as implantable middle ear hearing aid. The presented electromagnetic vibration transducer that composed of wounded coil, permanent magnet and 4-beam cross type elastic body is fabricated by using of micromachining technology. The fabricated transducer has experimental characteristics, that is 5 nm/mA of an energy trasfer rate at the frequency range of 100∼2800 Hz. It has a size of $2{\times}2{\times}2.5\;mm^3$.

  • PDF

Pulse-echo Response of Piezoceramic-Polymer 1-3 Type Composite Transducer for a Level Limit Switch Applications (Level Limit스위치용 1-3형 복합압전체 트랜스듀서의 펄스-에코응답특성)

  • Choi, H.I.;Sohn, M.H.;Kim, H.K.;Park, K.I.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.224-228
    • /
    • 2002
  • In this study, the piezoelectric ceramics PZT powder was synthesized by the Wet-Dry combination method. Flexible 1-3 type composite specimens were fabricated with the piezoceramics PZT filler phase and Eccogel polymer matrix phase. This paper represents the pulse-echo response of the 1-3 type composite transducer to check it out to investigate a basic property regarding a level limit switch. The acoustic impedance of 1-3 type composite was improved than that of single phase PZT ceramics. The pulse-echo response of transducer fabricated with the self-made 1-3 type composites resonator was better than that of the solid PZT transducer.

  • PDF

A Study on the Level Limit Switch for Underwater with 1-3 Type Ceramic/Polymer Composite Ultrasonic Transducer (1-3형 복합압전체 초음파 트랜스듀서를 사용한 수중용 레벨 Limit스위치에 관한 연구)

  • Kim, H.G.;Park, K.I.;Shin, K.H;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.292-295
    • /
    • 2003
  • In this study, an ultrasonic transducer is fabricated with 1-3 type composite resonators. Pulse-echo responses of an ultrasonic transducer are investigated in underwater dependent on the variable designated water-level. LED Output signals of a level limit with changing a water level is obtained by the 1-3 type self-made composite transducer and electric measuring unit. LED is turned on at above the up-limit level with increasing a water level, and LED is turned on at less than the down-limit level with decreasing a water level. There was good agreement between the virtual level and output LED signal by using the self-made water-detecting system.

  • PDF

A Development of Underwater Acoustic Tonpilz Transducer with the Piezoelectric Single Crystal (압전단결정(72PMN-28PT) 응용 수중음향 톤필츠 트랜스듀서 개발)

  • Kwon, Byung-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.9
    • /
    • pp.532-538
    • /
    • 2016
  • In this paper, a underwater acoustic Tonpilz transducer with the piezoelectric single crystal(72PMN-28PT) is developed. The thickness and the number of piezoelectric elements are theoretically designed with the equivalent circuit analysis to have the desired resonance frequency. In order to compare the performances, a piezoelectric ceramic transducer is also manufactured and their electrical impedance, TVR (transmitting voltage response), RVS (receiving voltage response) and beam pattern are compared.