Implementation a Physical Ear Model for Determinating Location of the Microphone of Fully Implantable Middle Ear Hearing Device (완전 이식형 인공중이용 마이크로폰의 위치 결정을 위한 물리적 귀 모델의 구현)

  • Kim, D.W.;Seong, K.W.;Lim, H.K.;Kim, M.W.;Jung, E.S.;Lee, J.W.;Lee, M.W.;Lee, J.H.;Kim, M.N.;Cho, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • Generally, implantable microphone has been implanted in the temporal bone for implantable middle ear hearing devices (IMEHDs). In this case, the microphone's membrane can be damaged and can be generated biological noise. In order to overcome the these problems, the location of implanted microphone should be changed. As an alternative, the microphone can be implanted in the external auditory canal. However, the sound emission can be produced because of vibration transducer toward reverse direction from the tympanic membrane to the external auditory canal. In this paper, an amount of the emitted sound is measured using a probe microphone as the changing the position of microphone in the external auditory canal of a physical ear model, which is similar to acoustical and vibratory properties of the human ear. Through the measured value, the location of the microphone was assumed in the external auditory canal. According to the analysis, the microphone input sound can be decreased when microphone position become more distance from the tympanic membrane in the auditory canal. However, the external auditory canal is not appropriated to implantable microphone position, because sound emission is not completely eliminated.

  • PDF

The Active Noise Control in Harmonic Enclosed Sound Fields (I) Computer Simulation (조화가진된 밀폐계 음장에서의 능동소음제어 (I) 컴퓨터 시물레이션)

  • Oh, Jae-Eung;Lee, Tae-Yeon;Kim, Heung-Seob;Shin, Joon
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1054-1065
    • /
    • 1993
  • A computer simulation is performed on the effectiveness of the active minimization of harmonically excited enclosed sound fields for producing global reduction in the amplitude of the pressure fluctuations. In this study for the appreciable reductions in total time averaged acoustic potential energy, $E_{pp}$, the transducer location strategies for three dimensional active noise control is presented based on a state space modal which approximates the closed acoustic field.In this study, the above theoretical basis is used to investigate the application of active control to sound fields of low modal density. By the used of room-like 3-dimensional rectangular enclosure it is demonstrated that the reductions in $E_{pp}$ can be achieved by using a single secondary source, provided that the source is placed within the half a wavelength from the primary source and placed away from nodal line of the sound field. Concerning the reductions in $E_{pp}$ by minimzing the pressure in sound fields by the use of 3-dimensional rectangular enclosure, the effects of the number of sensors and the locations of these sensors are investigated. When a few modes dominate the response it is found that if only a limited number of sensors are located away from nodal line and located at the pressure maxima of the sound field such as at each corner of a rectangular enclosure.

Transabdominal Ultrasound Assessment of the Polycystic Ovary Syndrome (다낭난소증후군 진단시 복식 초음파의 유용성에 관한 연구)

  • Jeong, Kyung-Ah;Lee, Woon-Jeong;Chung, Hye-Won
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.4
    • /
    • pp.255-263
    • /
    • 2009
  • Objective: The objective of the study was to determine the diagnostic performance of transabdominal ultrasound by receiver operating characteristic (ROC) curve analysis, in order to evaluate the usefulness in establishing the diagnosis of polycystic ovary syndrome (PCOS). Methods: Questionnaires were given to 8,793 reproductive women reviewed at Ewha Womans University Mokdong hospital. Ultrasound examinations were performed in 701 women with a transabdominal transducer. Transabdominal ultrasounds were performed in 185 normal control women (normal menstruation without hyperandrogenism or PCO morphology) and 248 PCOS patients according to National Institutes of Health (NIH) PCOS diagnosis criteria. ROC curves were calculated for ovarian volume and follicle number. Results: In normal control group, the mean age were $23.64{\pm}4.26$ years old and the mean ovarian volume and follicle number were $6.03{\pm}1.89\;cm^3$ and $6.49{\pm}1.93$, respectively. The ovarian volume showed an area under the ROC curve (AURC) of 0.761. A ovarian volume decision threshold >$9\;cm^3$ had a sensitivity of 51.0% and a specificity of 91.4% for the diagnosis of PCOS. The follicle number showed an AURC of 0.733. A follicle number decision threshold ${\geq}9$ had a sensitivity of 54.9% and a specificity of 87.0% for the diagnosis of PCOS. A follicle number decision threshold ${\geq}10$ had a sensitivity of 53.2% and a specificity of 90.4%. A follicle number and a ovarian volume did not have a high diagnostic power for screening for PCOS. Conclusion: Our results suggest that transabdominal ultrasound assessment is not effective for the detection of PCOS in young women of reproductive age.

Detection of Hydride Blisters in Zirconium Pressure Tubes using Ultrasonic Mode Conversion and Velocity Ratio Method (초음파 모드 변환 및 속도비 방법에 의한 지르코늄 압력관의 수소화물 블리스터 탐지)

  • Cheong, Yong-Moo;Lee, Dong-Hoon;Kim, Young-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.334-341
    • /
    • 2003
  • When the pressure tubes(f are in contact with the calandria tube(CT) in the pressurized heavy water reactor(PHWR), the temperature difference between inner and outer wall of W results in a thermal diffusion of hydrogen (deuterium) and hydride blisters are formed on the outer surface of PT. Because the hydride blisters and zirconium matrix are acoustically continuous, it is not easy to distinguish the blisters from the matrix with conventional ultrasonic method. An ultrasonic velocity ratio method was developed to detect small hydride blisters on the zirconium pressure tube. Hydride blisters were grown in the PT specimen using a steady state thermal diffusion device. The flight times of longitudinal echo and reflected shear echo from the outer surface were measured accurately. The velocity ratio of the longitudinal wave to the shear wave was calculated and displayed using contour plot. Compared to the conventional flight time method of longitudinal wave, the velocity ratio method shows superior sensitivity to detect smaller blisters as well as better images for the blister shapes. Detectable limit of the outer shape of the hydride blisters was conservatively estimated as $500{\mu}m$, with the same specifications of ultrasonic transducer used in the actual PHWR pressure tube inspection.

Detection of Small Flaws in SiC Structural Ceramic in High Frequency Detection Field (고주파수 초음파 검출장에서 SiC 세라믹 내부의 미세결함 검출)

  • Kim, Byoung-Geuk;Lee, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.2
    • /
    • pp.100-107
    • /
    • 1997
  • It has been required to find flaws smaller than $100{\mu}m$ by fracture mechanic consideration. We prepared the infiltrated and sintered SiC structural ceramic specimens including artificial flaws, Fe, pore, WC, Si particles of size ranging from $36{\mu}m$ to $200{\mu}m$. We performed C-scan for the specimen using a high frequency and broad-band ultrasonic transducer to employ polyvinylidene fluoride(PVDF) and a broad-band electric scanning system. The flaws in the ceramic specimens were detected in the high frequency detection field up to 100MHz. But, the flaws were not detected in lower frequency detection field up to 60MHz. The ratio of the detected smallest flaw size to the wavelength calculated at the center frequency, 80MHz, was about 0.25 in Rayleigh scattering region.

  • PDF

Design of Gastrointestinal Diagnosis System based on Ultrasonic Response Characteristics (초음파 응답특성 분석에 의한 위장 경화 진단시스템의 설계)

  • Lim, Do-Hyung;Kim, Eun-Geun;Lee, Gyoun-Jung;Park, Won-Pil;Kim, Han-Sung;Shin, Tae-Min;Choi, Seo-Hyung;Lee, Yong-Heum
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.250-257
    • /
    • 2007
  • Functional gastrointestinal disorders affect millions of people of all age regardless of race and sex. There are, however, rare diagnostic methods for the functional gastrointestinal disorders because functional disorders show no evidence of organic and physical causes. Our research group identified recently that the gastrointestinal tract well in the patients with the functional gastrointestinal disorders becomes more rigid than healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The aim is, therefore, to develop a diagnostic method for the functional gastrointestinal disorders based on quantitative measurement of the rigidity of the gastrointestinal tract well using ultrasound technique. For this purpose, a preliminary ultrasound diagnostic system was developed and verified through phantom tests. The system consisted of transmitter, ultrasonic transducer, receiver, TGC, and CPLD, and verified via a phantom test. For the phantom test, ten soft-tissue specimens were harvested from porcine. Five of them were then treated chemically to mimic a rigid condition of gastrointestinal tract well, which was induced by functional gastrointestinal disorders. Additionally, the specimens were tested mechanically to identify if the mimic was reasonable. The customized ultrasound system was finally verified through application to human subjects with/without functional gastrointestinal disorders(Normal and Patient Groups). It was identified from the mechanical test that the chemically treated specimens were more rigid than normalspecimen. This finding was favorably compared with the result obtained from the phantom test. The phantom test also showed that ultrasound system well described the specimen geometric characteristics and detected an alteration in the specimens. The maximum amplitude of the ultrasonic reflective signal in the rigid specimens $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal specimens $(0.1{\pm}0.0Vp-p)$ (p<0.05). Clinical tests using our customized ultrasound system for human subject showed that the maximum amplitudes of the ultrasonic reflective signals nea. to the gastrointestinal tract well for the patient group$(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group$(0.1{\pm}0.2Vp-p)$ (p<0.05). These results suggest that newly designed diagnostic system based on ultrasound technique may diagnose enough the functional gastrointestinal disorders.

Calibration of Hydrographic Survey Multibeam System Using Terrestrial Laser Scanning and TS Surveying (지상 레이저 스캐닝과 TS 측량을 이용한 멀티빔 시스템의 검·보정)

  • Kim, Jin Soo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.3
    • /
    • pp.199-207
    • /
    • 2013
  • In hydrographic survey, data surveyed with multibeam system includes various errors due to multiple factors. These are corrected by a calibration called patch test, and if existing method is used, the test needs to be conducted for about 8 times for precise system calibration. For more prompt and precise multibeam system calibration, the exact offset of a ship was determined using terrestrial laser scanning and TS surveying, which was used as the initial input for the patch test. In the result, the error of closure was 0.001 m or less for TS surveying and backsight error was 0.005 m or less for scanning. All the surveying data based on the same local coordinate was converted into vessel reference coordinate during which R-square for all rotation angles was 0.99 or higher and standard deviation was 0.008 m or less. Finally, in a patch test using calculated offset of sensors and motion sensor offset, the offset of MBES transducer satisfied manual on hydrography only with 1-time calibration. With these results, it is thought that terrestrial laser scanning and TS surveying can fully be utilized for multibeam system calibration.

Study on the Nonlinear Electromagnetic Acoustic Resonance Method for the Evaluation of Hidden Damage in a Metallic Material (금속 재료의 잠닉손상 평가를 위한 비선형 전자기음향공진 기법에 관한 연구)

  • Cho, Seung-Wan;Cho, Seung-Hyun;Park, Choon-Su;Seo, Dae-Cheol;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.277-282
    • /
    • 2014
  • Recently, much attention has been paid to nonlinear ultrasonic technology as a potential tool to assess hidden damages that cannot be detected by conventional ultrasonic testing. One nonlinear ultrasonic technique is measurement of the resonance frequency shift, which is based on the hysteresis of the material elasticity. Sophisticated measurement of resonance frequency is required, because the change in resonance frequency is usually quite small. In this investigation, the nonlinear electromagnetic acoustic resonance (NEMAR) method was employed. The NEMAR method uses noncontact electromagnetic acoustic transducers (EMATs) in order to minimize the effect of the transducer on the frequency response of the object. Aluminum plate specimens that underwent three point bending fatigue were tested with a shear wave EMAT. The hysteretic nonlinear parameter ${\alpha}$, a key indicator of damage, was calculated from the resonance frequency shift at several levels of input voltage. The hysteretic nonlinear parameter of a damaged sample was compared to that of an intact one, showing a difference in the values.

Skeletal Muscle Ventricle Mechanics (골격근 심실의 역학)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.428-432
    • /
    • 1999
  • Background: It has been shown that low-grade electrical stimulus can transform fatigue resistant muscles which then can be used to protect the heart. The bulky and cumbersome power sources of the artificial heart or implantable ventricular assist devices are still in need of solution; however, on the other hand, the implantable ventricular assist devices using the resistant muscles as the power source have the advantages of using its own muscle contractions. The purpose of this study was to determine the possibility of a clinical application of the skeletal muscle ventricle. Material and Method: Latissimus dorsi muscles (LDM) of 8 canines were used for skeletal muscle ventricle. A latex chamber was wrapped one and a half times with LDM. The chamber was attached to a pressure transducer via Tygon tube. An electrode stimulator was placed around the thoracodorsal nerve and LDM was stimulated in cyclic bursts of 0.31 sec on time and 6.0 sec off time using 3.0 volt Itrel stimulator. The preload volume was added to the system in 25cc increments. Ejection volumes, pressures, and peak power outputs were measured. Result: Ejection volume was 76.3cc with 0cc of preload. Ejection volumes were less than 70ml with increments of preload over 75cc Pressures were more than 107 mmHg when the preloads were less than 75cc and less than 100 mmHg when the preloads were more than 100cc. Peak power output of 16.6 W/kg was observed at 50cc preload. Conclusion: Depending on the changes of preload, the volumes ejected from skeletal muscle ventricle and pressures from the skeletal muscle contraction surpassed those of the normal heart. These data suggest that there are clinical applications for skeletal muscle ventricular assist system.

  • PDF

Photochemical/Biophysical Properties of Proteorhodopsin and Anabaena Sensory Rhodopsin in Various Physical Environments (막 단백질인 Proteorhodopsin과 Anabaena Sensory Rhodopsin의 다양한 측정 환경에 따른 광화학/생물리학적 특성)

  • Choi, Ah-Reum;Han, Song-I;Chung, Young-Ho;Jung, Kwang-Hwan
    • Korean Journal of Microbiology
    • /
    • v.47 no.1
    • /
    • pp.22-29
    • /
    • 2011
  • Rhodopsin is a membrane protein with seven transmembrane region which contains a retinal as its chromophore. Although there have been recently reports on various photo-biochemical features of rhodopsins by a wide range of purifying and measurement methods, there was no actual comparison related to the difference of biochemical characteristics according to their physical environment of rhodopsins. First, proteorhodopsin (PR) was found in marine proteobacteria whose function is known for pumping proton using light energy. Second one is Anabaena sensory rhodopsin (Nostoc sp.) PCC7120 (ASR) which belongs to eubacteria acts as sensory regulator since it is co-expressed with transducer 14 kDa in an operon. In this study, we applied two types of rhodopsins (PR and ASR) to various environmental conditions such as in Escherichia coli membranes, membrane in acrylamide gel, in DDM (n-dodecyl-${\beta}$-D-maltopyranoside), OG (octyl-${\beta}$-D-glucopyranoside), and reconstituted with DOPC (1,2-didecanoyl-sn-glycero-3-phosphocholine). According to the light-induced difference spectroscopy, rhodopsins in 0.02% DDM clearly showed photointermediates like M, and O states which respond to the different wavelengths, respectively and showed the best signal/noise ratio. The laser-induced difference spectra showed the fast formation and decay rate of photointermediates in the DDM solubilized samples than gel encapsulated rhodopsin. Each of rhodopsins seemed to be adapted to its surrounding environment.