• Title/Summary/Keyword: TPS surface

Search Result 42, Processing Time 0.028 seconds

A Study on Friction-induced Surface Fracture Behaviors of Carboxylic Acid Modified Styrenic Thermoplastic Elastomer as Additives (첨가제에 따른 변성 스티렌계 열가소성 엘라스토머의 마찰에 의한 표면 파괴 거동 연구)

  • Jeon, Jun-Ha;Park, Sang-Min;Lee, Jin- Hyok;Um, Gi-Yong
    • Journal of Adhesion and Interface
    • /
    • v.16 no.3
    • /
    • pp.95-100
    • /
    • 2015
  • In this work, we observed the effect of silica, zinc oxide, zinc ion coated silica on carboxylic acid modified styrenic thermoplastic elastomer (m-TPS) film for friction-induced surface fracture. m-TPS film added general silica showed poor mechanical properties, anti-abrasion and friction-induced surface fracture, caused by strong filler-filler interaction of silica. In case of m-TPS films added zinc oxide or zinc ion coated silica, mechanical properties, anti-abrasion and friction-induced surface fracture were improved due to forming ionic cluster between carboxylic acid group of m-TPS and zinc ion. Ionic cluster were confirmed by FT-IR analysis that observed zinc carboxylated group stretch peak at $1550{\sim}1650cm^{-1}$.

A Study on the Surface Roughness and Initial Stability of Various Dental Implants (수종 임플랜트의 표면 거칠기와 초기안정성에 관한 연구)

  • Cho, Dong-Hoon;Lim, Ju-Hwan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.3
    • /
    • pp.197-210
    • /
    • 2000
  • Surface roughness is one of implant surface topography and it's found that surface roughness characterizations, such as surface energy, oxide layer thickness and its chemical composition, are closely correlated if the roughness is changed. Several studies showed the importance of analyzing surface structure so the surface structure of thread implant was analyzed to measure the implant quality exactly. In this study, surface roughness of 4 implants - MK $II^{(R)}$(Nobel Biocare), $RBM^{(R)}$(Life-Core, USA), $Osseotite^{(R)}$(3i, USA), $TPS^{(R)}$(Life-Core, USA) - were measured using $Accura^{(R)}$ and 40 implants were installed into 4 sets of ten bovine ribs based on the parameters from the measurements. From this test, the following conclusions for the initial stability were drawn by measuring and comparing RFA, Periotest Value (PTV), Removal Torgue Value (RTV). 1. $R_a$ value in surface roughness measurement was increasing by the order of $MKII^{(R)}$, $Osseotite^{(R)}$, $RBM^{(R)}$, $TPS^{(R)}$ and $R_q$ value was the same order. 2. $R_q$ value in each section was observed to increase by the order of $MKII^{(R)}$, $Osseotite^{(R)}$, $RBM^{(R)}$, $TPS^{(R)}$ in top and $MKII^{(R)}$, $RBM^{(R)}$, $Osseotite^{(R)}$, $TPS^{(R)}$ in mid-section but the value of $MKII^{(R)}$ bottom was the lowest, followed by $Osseotite^{(R)}$, $RBM^{(R)}$ and $TPS^{(R)}$. 3. RFA increased by the order of $RBM^{(R)}$(7042Hz), $MKII^{(R)}$(7047Hz), $Osseotite^{(R)}$(7076Hz), $TPS^{(R)}$(7168Hz) and there was no significance between each group. 4. PTV was increasing by the order of $MKII^{(R)}$(-1.62), $TPS^{(R)}$(-1.92), $Osseotite^{(R)}$ & $RBM^{(R)}$(-2.08) and there was no significance, either. 5. Removal torque in RTV measurement showed the increasing order of $MKII^{(R)}(5.31kgf{\cdot}cm)$, $Oeeotite^{(R)}(5.71kgf{\cdot}cm)$, $TPS^{(R)}(5.92kgf{\cdot}cm)$ and $RBM^{(R)}(7.24kgf{\cdot}cm)$ and there was no significance among groups. Above observations explains that surface roughness does not make any impact on the initial stability of implants installation.

  • PDF

SCANNING ELECTRON MICROSCOPIC STUDY OF IMPLANT SURFACE AFTER Er,Cr:YSGG LASER IRRADIATION (Er,Cr:YSGG 레이저를 조사한 임플란트 표면의 주사전자현미경적 연구)

  • Jo, Pil-Kwy;Min, Seung-Ki;Kwon, Kyung-Hwan;Kim, Young-Jo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.5
    • /
    • pp.454-469
    • /
    • 2006
  • Today, there is considerable evidence to support a cause-effect relationship between microbial colonization and the pathogenesis of implant failures. The presence of bacteria on implant surfaces may result in an inflammation of the peri-implant mucosa, and, if left untreated, it may lead to a progressive destruction of alveolar bone supporting the implant, which has been named as peri-impantitis. Several maintenance regimens and treatment strategies for failing implants have been suggested. Recently, in addition to these conventional tools, the use of different laser systems has also been proposed for treatment of peri-implant infections. As lasers can perform excellent tissue ablation with high bactericidal and detoxification effects, they are expected to be one of the most promising new technical modalities for treatment of failing implants. It is introduced that Er,Cr:YSGG laser, operating at 2780nm, ablates tissue by a hydrokinetic process that prevents temperature rise. We studied the change of the titanium implant surface under scanning electron microscopy after using Er,Cr:YSGG laser at various energies, irradiation time. In this study, Er,Cr:YSGG laser irradiation of implant fixture showed different effects according to implant surface. Er,Cr:YSGG laser in TPS surface with RBM not alter the implant surface under power setting of 4 Watt(W) and irradiation time of 30sec. But in TPS surface with $Ca_3P$ coating alter above power setting of 2W and irradiation time of 10sec. TPS surface with RBM showed microfracture in 4W, 30sec and TPS surface with $Ca_3P$ coating showed destruction of fine crystalline structure, melting in excess of 2W, 10sec. We concluded that proper power setting, air, water of each implant surface must be investigated and implant surface must be irradiated under the damaged extent.

Mechanical Properties and Biodegradability of PCL/TPS Blends (PCL/TPS 블렌드의 물성 및 생분해도)

  • 신창호;김영진;김봉식;신부영
    • Polymer(Korea)
    • /
    • v.24 no.1
    • /
    • pp.48-57
    • /
    • 2000
  • Polycaprolactone (PCL) and thermoplastic starch (TPS) blends were prepared. Mechanical properties, thermal property, water absorption, biodegradability by composting and surface morphology of PCL/TPS blends were investigated. The compositions of PCL/TPS blends were 90/10, 80/20, 70/30, 60/40, 50/50, 40/60, 30/70, 20/80, and 10/90. Strength and elongation at break decreased as the content of TPS increased, while modulus increased. DSC thermogram of TPS showed two glass transition temperatures (T$_{g}$ ) at 23$^{\circ}C$ and 126$^{\circ}C$. And TPS proved to be an amorphous polymer because there was no endothermic peak due to the melting of starch crystal. The unchanged melting temperatures and T$_{g}$ 's of PCL/TPS blends revealed that PCL and TPS were not miscible. All of the blends were found to be mechanically compatible but phase separated in each other. After 45 days composting, the biodegradability of PCL was 44% and that of PCL/TPS blends increased as the contents of TPS increased.

  • PDF

Mechanical Properties and Biodegradability of HDPE/TPS Blends (HDPE/TPS블렌드의 물성 및 생분해도)

  • 이상일;홍경민;서석훈;신용섭;김봉식;신부영
    • Polymer(Korea)
    • /
    • v.26 no.1
    • /
    • pp.145-151
    • /
    • 2002
  • Thermoplastic starch(TPS) was prepared from mixing starch and glycerol by twin extruder. The blends were then prepared from high density polyethylene(HDPE) and TPS. Mechanical properties, thermal properties, and morphology of the blends were investigated. Their biodegradability was also studied by using aerobic composting method(ISO14855). Tensile strength, modulus and elongation at break decreased as the content of TPS increased. In particular elongation at break decreased rapidly even at the lower content of TPS. The melting temperatures of the blends were not changed, which showed that HDPE and TPS were immiscible. The morphology of the fractured surface of blend films was investigated by scanning electron microscopy(SEM). It was found that phases were separated. After composting for 45days, the biodegradability of the blends increased as the content of TPS increased.

A Study on Large Surface TPS Reinforced Cover Glass Grinding Process Development (대면적 TPS 강화 Cover Glass Grinding 공정 개발에 관한 연구)

  • Lee, Taeho;Song, Jaichul;Lee, Seonhee
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.3
    • /
    • pp.48-52
    • /
    • 2015
  • In this paper, we develops a domestic and foreign first reinforced cover glass grinding process for large surface TPS and resolves a problem of conventional cover glass grinding process through a research. Also, it is developed in priority to improve a productivity and processing quality emphasis. The development process develops a total process technology through a production and operation of demonstration unit. so, in this paper, we secured cover glass grinding process technology, image processing technology, mechanisms and control algorithms.

Out-of-Plane Deformation Measurement of TPS in Vehicle Using ESPI (ESPI를 이용한 자동차 TPS 면외변형 계측)

  • Han, Sang-Kil;Ham, Hyo-Shick;Ham, Sang-Hyun;Lee, Jong-Hwang;Jung, Won-Wook;Lee, Chang-Hee;Lee, Sang-Bong;Choi, Sung-Eul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.423-428
    • /
    • 2010
  • In this paper, we analyzed the characteristics of thermal deformation of the TPS which is a core part of engine in vehicle by measuring out-of-plane deformation using ESP!. Inspection area of a test piece was minimized to 5 cm by 5 cm by using a high resolution CCD and a zoom lens. 4-step phase shifting method was used along with phase unwrapping algorithm to get a continuous phase map, configurations and deformations were displayed as 3D images. When heating the test pieces while maintaining the temperature at about $70^{\circ}C$, the out-of-plane deformations were measured. The results showed that a test piece with longer distance traveled tends to show larger thermal deformation, we could observes a convex shaped deformation on the surface. The inner defect sample, we could monitor discontinuous pattern phase map, and a concave shaped deformation on the surface.

TPS Analysis of Various Metal Plates for Belt Source Evaporation in AMOLED Manufacturing

  • Hwang, Chang-Hun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1603-1606
    • /
    • 2007
  • The TPS (Temperature Programmed Sublimation) technology has been developed to monitor the plane evaporation of the organic films and introduced in SID2007, P53.[4] The Alq3 organic film is deposited on various metal surface such as Cu, Ti, Invar, STS to sublimate. The TPS signal confirms that the Alq3 film consists of nano scale film phase and bulk phase on all the metal plates. The sublimation temperature of the Alq3 film was much lower ($130^{\circ}C$) than the vapor temperature ($265^{\circ}$) of the Alq3 powder.

  • PDF

A STUDY ON THE INTERPOLATION METHODS FOR THE FLUID-STRUCTURE INTERACTION ANALYSIS (유체-구조 연계 해석을 위한 보간 기법 연구)

  • Lee, J.;Kwon, J.H.
    • Journal of computational fluids engineering
    • /
    • v.13 no.1
    • /
    • pp.41-48
    • /
    • 2008
  • The fluid-structure interaction analysis such as a static aeroelastic analysis requires the result of each analysis as an input to the other analysis. Usually the grids for the fluid analysis and the structural analysis are different, so the results should be transformed properly for each other. The Infinite Plate Spline(IPS) and the Thin Plate Spline(TPS) are used in interpolating the displacement and the pressure. In this study, such interpolation methods are compared with kriging which provides a precise response surface. The static aeroelastic analysis is performed for the supersonic flow field with shock waves and the pressure field is interpolated by the TPS and kriging. The TPS shows tendency to weaken the shock strength, whereas kriging preserves the shock strength.