• Title/Summary/Keyword: TPS

검색결과 329건 처리시간 0.021초

Expression pattern of floral scent genes in different flowering stages of Chrysanthemum cultivars

  • Mekapogu, Maniulatha;Ahn, Myung Suk;Yoo, Jong Hee;Jeong, Jae Ah;Park, Jong Taek;Kwon, Oh Keun
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2018년도 추계학술대회
    • /
    • pp.114-114
    • /
    • 2018
  • Among the various volatile organic compounds (VOCs) emitted by the plant, floral scent plays a key role in attracting pollinators for reproduction and mediates ecological interactions. Floral scent is an important trait and industry drives the competition for flowers with novel scents. Chrysanthemum is one of the well-known ornamental plants and is a popular cut flower across the world. Floral scent and the genes responsible for the floral scent emission are poorly studied in chrysanthemum. In the present study, floral scent and the expression pattern of floral scent genes were analyzed in two chrysanthemum cultivars 'Golden Egg' and 'Gaya Glory'. Initially, intensity of the floral scent in five developing stages of flower including 'budding (B), bud developing (BD), initial blooming (IB), almost open (AO) and open flower (OF)' was analyzed using electronic nose (E-nose) with six metal oxide sensors. Based on the distance analysis, different stages of flower showed different relative intensity of scent according to the sensory evaluation. Although the scent pattern differed by stage, scent intensity was strongest in the OF stage in the completely opened flower in both the cultivars. Further, expression pattern of six genes in the floral scent pathway including FDS, IDI, ISPH, TPS2, TPS5 and TPS6 was observed in all the five stages of the flower in both the cultivars. The expression pattern of all the six genes differed by stage and the terpene synthase genes TPS2, TPS5 and TPS6 showed good expression levels in the $5^{th}$ flower stage compared to other stages. This study provides a preliminary data for understanding the regulation of floral scent in chrysanthemum.

  • PDF

Trehalose Metabolism: Gate to Stress Signaling and Seed Development in Plant\ulcorner

  • Chung, H-J;Kim, Y-S;Lee, E-J;Kim, J-S;Shin, Y-M;Cho, I-S;Jin, H-O;Cho, J-W;Chung, C-H
    • 식물조직배양학회지
    • /
    • 제27권5호
    • /
    • pp.415-421
    • /
    • 2000
  • The disaccharide trehalose ($\alpha$-D-glucopyranosyl-$\alpha$-D-glucopyranoside) is found in variety of organ-isms that are able to withstand almost complete desiccation. In order to identify the function of trehalose in plants, we isolated Arabidopsis trehalase (AtTRE) gene that encodes the enzyme able to hydrolyze trehalose to glucose, and trehalose-6-phosphate synthase isolog, TPS3 gene by RT-PCR. The AtTRE had the substrate specificity to hydrolyze only trehalose, and a broad pH range of enzyme activity. The AtTRE promoter/GUS reporter gene was expressed in cotyledons, mature leaf tissues including guard cells, and developing siliques. The GUS expression driven by AtTPS3 promoter was significant in root tissues, and the level of GUS activity was much higher than that of the pBll 21 control seedlings. The knockout of AtTPS3 gene in Arabidopsis resulted in the retarded root development, whereas the overexpression of AtTPS3 increased the root elongation in the presence of sucrose in MS medium. Possible functions of AtTRE and AtTPS3 in plant will be discussed. In addition, ectopic expression of yeast TPS1 driven by the inducible promoters in tobacco and potato conferred the plants on the drought and freezing tolerances.

  • PDF

TPS: TPM 및 파일 가상화를 통한 개인정보보호 자동화 시스템 디자인 및 구현 (Design and Implementation of an Automated Privacy Protection System over TPM and File Virtualization)

  • 정혜림;안성규;김문성;박기웅
    • 한국차세대컴퓨팅학회논문지
    • /
    • 제13권2호
    • /
    • pp.7-17
    • /
    • 2017
  • 본 논문에서는 TPM(Trusted Platform Module) 기반의 개인정보보호 자동화 시스템, TPS(TPM-enhanced Privacy Protection System)를 제안한다. TPS는 클라이언트 내 저장된 문서 중 개인정보를 포함하는 문서를 주기적으로 탐지하고 개인정보가 탐지된 문서를 암호화하여 서버에서 이를 관리하도록 하는데, TPM 기반의 키 관리기법 및 클라이언트 시스템의 무결성 검증을 통해 비정상 상태의 클라이언트에 대한 개인정보 포함 문서의 열람을 제한하여 보안성을 높였다. 또한 개인정보가 포함된 문서가 암호화 되어 원격 서버에 저장이 되나, 사용자에게는 일반 문서 접근과 동일한 사용자 인터페이스를 제공하기 위한 VTF(Virtual Trusted File) 인터페이스를 제안하고 이를 구현하였다. 이를 통해 TPS는 개인정보 탐지, 암호화, 원격 서버로의 저장까지의 일련의 과정을 자동 수행하도록 하여 사용자 관점에서의 개입 없이 개인정보보호법을 준수를 자동화 하는 시스템을 구현하였다.

수종 임플랜트의 표면 거칠기와 초기안정성에 관한 연구 (A Study on the Surface Roughness and Initial Stability of Various Dental Implants)

  • 조동훈;임주환
    • 구강회복응용과학지
    • /
    • 제16권3호
    • /
    • pp.197-210
    • /
    • 2000
  • Surface roughness is one of implant surface topography and it's found that surface roughness characterizations, such as surface energy, oxide layer thickness and its chemical composition, are closely correlated if the roughness is changed. Several studies showed the importance of analyzing surface structure so the surface structure of thread implant was analyzed to measure the implant quality exactly. In this study, surface roughness of 4 implants - MK $II^{(R)}$(Nobel Biocare), $RBM^{(R)}$(Life-Core, USA), $Osseotite^{(R)}$(3i, USA), $TPS^{(R)}$(Life-Core, USA) - were measured using $Accura^{(R)}$ and 40 implants were installed into 4 sets of ten bovine ribs based on the parameters from the measurements. From this test, the following conclusions for the initial stability were drawn by measuring and comparing RFA, Periotest Value (PTV), Removal Torgue Value (RTV). 1. $R_a$ value in surface roughness measurement was increasing by the order of $MKII^{(R)}$, $Osseotite^{(R)}$, $RBM^{(R)}$, $TPS^{(R)}$ and $R_q$ value was the same order. 2. $R_q$ value in each section was observed to increase by the order of $MKII^{(R)}$, $Osseotite^{(R)}$, $RBM^{(R)}$, $TPS^{(R)}$ in top and $MKII^{(R)}$, $RBM^{(R)}$, $Osseotite^{(R)}$, $TPS^{(R)}$ in mid-section but the value of $MKII^{(R)}$ bottom was the lowest, followed by $Osseotite^{(R)}$, $RBM^{(R)}$ and $TPS^{(R)}$. 3. RFA increased by the order of $RBM^{(R)}$(7042Hz), $MKII^{(R)}$(7047Hz), $Osseotite^{(R)}$(7076Hz), $TPS^{(R)}$(7168Hz) and there was no significance between each group. 4. PTV was increasing by the order of $MKII^{(R)}$(-1.62), $TPS^{(R)}$(-1.92), $Osseotite^{(R)}$ & $RBM^{(R)}$(-2.08) and there was no significance, either. 5. Removal torque in RTV measurement showed the increasing order of $MKII^{(R)}(5.31kgf{\cdot}cm)$, $Oeeotite^{(R)}(5.71kgf{\cdot}cm)$, $TPS^{(R)}(5.92kgf{\cdot}cm)$ and $RBM^{(R)}(7.24kgf{\cdot}cm)$ and there was no significance among groups. Above observations explains that surface roughness does not make any impact on the initial stability of implants installation.

  • PDF

Evaluation of electron dose distribution obtained from ADAC Pinnacle system against measurement and Monte Carlo method for breast patients

  • Lee, S.;Lee, R.;Park, D.;S. Suh
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.82-82
    • /
    • 2003
  • Introduction: With the development of dose calculation algorithms for electron beams, 3D RTP systerns are available for electron beam dose distribution commercially. However, no studies evaluated the accuracy of dose calculation with ADAC Pinnacle system for electron beams. So, the accuracy of the ADAC system is investigated by comparing electron dose distributions from ADAC system against the BEAMnrc/DOSXYZnrc. Methods: A total of 33 breast cancer patients treated with 6, 9, and 12MeV electrons in our institution was selected for this study. The first part of this study is to compare the dose distributions of measurement, TPS and the BEAMnrc/DOSXYZnrc code in flat water phantom at gantry zero position and for a 10 ${\times}$ 10 $\textrm{cm}^2$ field. The second part is to evaluate the monitor unit obtained from measurement and TPS. Adding actual breast patient's irregular blocks to the first part, monitor units to deliver 100 cGy to the dose maximum (dmax) were calculated from measurement and 3D RTP system. In addition, the dose distributions using blocks were compared between TPS and the BEAMnrc/DOSXYZnrc code. Finally, the effects of tissue inhomogeneities were studied by comparing dose distributions from Pinnacle and Monte Carlo method on CT data sets. Results: The dose distributions calculated using water phantom by the TPS and the BEAMnrc/ DOSXYZnrc code agreed well with measured data within 2% of the maximum dose. The maximum differences of monitor unit between measured and Pinnacle TPS in flat water phantom at gantry zero position were 4% for 6 MeV and 2% for 9 and 12 MeV electrons. In real-patient cases, comparison of depth doses and lateral dose profiles calculated by the Pinnacle TPS, with BEAMnrc/DOSXYZnrc code has generally shown good agreement with relative difference less than +/-3%. Discussion: For comparisons of real-patient cases, the maximum differences between the TPS and BEAMnrc/DOSXYZnrc on CT data were 10%. These discrepancies were due in part to the inaccurate dose calculation of the TPS, so that it needs to be improved properly. Conclusions: On the basis of the results presented in this study, we can conclude that the ADAC Pinnacle system for electron beams is capable of giving results absolutely comparable to those of a Monte Carlo calculation.

  • PDF

탄성 저장관과 스마트 밸브가 일체화된 주입 포트와 이동식 주입기를 이용한 콘크리트 구조물의 균열보수 주입공법 (TPS 공법)(건설신기술 제 822호) (Crack Repairing Injection Method of Concrete Structure Using Injection Port and Removable Injector Integrated with Elastic Storage Hall and Smart Valve(TPS Method))

라텍스 탄성 저장관을 활용한 포트식 균열주입 공법의 물리적 특성에 관한 연구 (The Physical Properties of Port Type Crack Injection Method Using Latex Elastic Storage Tube)

  • 김은영;소광호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권2호
    • /
    • pp.68-75
    • /
    • 2018
  • 본 연구에서는 기존의 균열보수 주입공법의 문제점을 해결하기 위하여 일반포트와는 다르게 중앙부에 높은 압력을 견딜 수 있도록 저장관의 재질은 고탄성 라텍스를 사용하였으며, 균열부위에 보수용액을 주입시 콘크리트 균열 내부에 존재하고 있는 공기가 배출될 수 있도록 TPS 공법을 개발 하였다. 또한 보수용액의 역류를 차단하는 밸브를 주입구에 설치한 새로운 주입식 포트를 개발하고 이에 대한 물리적 특성을 분석하였다. 분석 결과, 기존 주사기 공법에 비해 보수용액 주입속도가 향상되고, 시험조건에서 균열부위가 완전히 충전되는 것을 알 수 있었다. 보수 후의 품질은 압축강도 및 인장강도의 경우 주사기 공법 적용시에는 보수 후 약 20% 정도 저하하는 것으로 나타났고, TPS 공법 은 보수 후 강도가 오히려 약 2~7% 증가하는 경향으로 나타났다. 본 연구 결과를 통하여 탄성저장관을 사용한 주입식 포트 공법은 기존의 주사기 공법과 비교하여 주입성능 및 보수 후 품질이 증가하는 것을 알 수 있었고, 이를 활용하여 실구조물 적용 및 상용화를 위한 기반 자료로서 활용하고자 한다.

도요타생산방식의 효과적인 도입을 위한 방법론 연구 : Part I, 도요타생산방식 프레임워크를 중심으로 (A Study on the Framework and its implementation of Toyota Production System)

  • 이영훈;권순걸;이홍;이현;김찬모
    • 산업공학
    • /
    • 제20권3호
    • /
    • pp.235-244
    • /
    • 2007
  • The Toyota Production System (TPS) developed by Toyota Motor Corporation is a management principle and production method to improve values added thorough elimination of waste. Since the oil shock in 1970s, the TPS has drawn the worldwide attentions as a main factor of competitiveness of Japanese manufacturing system and has been studied and implemented in many countries regardless of size and types of industry. While the principles of the TPS system are known widely, the framework and the implementation methodology are rarely discussed, especially in the domestic companies. In this paper, the framework of the TPS system are developed as a view of the domestic practitioners and researchers, with which the introduction strategy can be developed as a guideline.

성경 대퇴골에 매식된 Titanium Plasma Spray 및 Hydroxyapatite 피복임프란트 주위의 골치유 양상 (HISTOLOGIC EvALUATION OF BONE HEALING AROUND TITANIUM PLASMA SPRAYED AND HYDROXYAPATITE-COATED IMPLANTS IN DOGS)

  • 허기남;정현주
    • Journal of Periodontal and Implant Science
    • /
    • 제25권2호
    • /
    • pp.418-437
    • /
    • 1995
  • The effect of the hydroxyapatite coatings on Titanium implants has been the subject of recent investigations. So far, the use of HA coating remains substantially controversial.This study was aimed to evaluate histologically the bone healing patterns around titanium plasm sprayed(TPS) amd HA-coated implant after implantation into the femur neck of ten adult dogs. After implantation, animals were sacrificed at the intervals of 2,4,6,8 and 12 weeks.The fluorescent dyes were injected on the postoperative 4th and 12th week into the animals supposed to be killed at the 12th week. The morphology and direction of new bone formation was similar in both TPS and HA-coated implants.There was a tendency toward more bone formation in the cortical bone area than in the cancellous bone area. Histologically,in the interface of the HA-coated implants, bone response and bone maturation was faster, compared to the TPS implants in the 2nd and 4th week. By fluorescent microscopy, new bone formation was active in the 4th week around both implants and was directed from the periosteum overlying cortical bone to the cancellous bone. These results suggest that the bone formation and maturation is faster during the early healing stage in the interface of the HA-coated implant and where the cortical bone quality is poor, HA coated implant is superior to the TPS implant in the early phase of new bone formation.

  • PDF

HA, TPS 및 $Al_2O_3$ 인공치근 매식체의 조직반응에 관한 실험적 연구 (EXPERIMENTAL STUDIES ON THE TISSUE RESPONSE OF HA COATED, TPS AND $Al_2O_3$ ARTIFICIAL ROOT IMPLANTS)

  • 김선영;김영수
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.267-284
    • /
    • 1991
  • Since the concept of a direct contact between bone and implants, without interposed soft- tissue layers, was reported by Dr. $Br{\aa}nemark$, there has been increasing necessity for correct under-standing of bone-implant interface and surrounding tissue response. Beside quality of bone, surgical technique, load applied to implants, one must consider implant materials, design and surface characteristics to obtain osseointegration. In this study HA plasma-sprayed implants, TPS implants and $Al_2O_3$ implants were inserted into the alveolar bone of dog and tissue response was observed with radiograph, stereoscope, light microscope, and scanning electron microscope. Results were as follows : 1. There was rapid and active bone formation in the region adjacent to HA plasma-sprayed implants but in the deep supporting bone only slight bone formation was seen. 2. There was considerable lamella bone formation in the region adjacent to TPS implants and the deep supporting bone became more compact. 3. There was some gap and sclerosing bone formation in the adjacent region of $Al_2O_3$ implants, but there was irregular new bone formation in the deep supporting bone. Therefore, it seems that $Al_2O_3$ is not adequate for osseointegrated implants.

  • PDF