• Title/Summary/Keyword: TP Removal

Search Result 234, Processing Time 0.024 seconds

Evaluation of Korean Water Quality Standards in Winter by Characteristics and Statistical Analyses of the Effluent Water Quality at the Sewage Treatment Plants in Korea (우리나라 공공하수처리시설의 방류수 수질현황 분석을 통한 겨울철 방류수수질기준의 적정성 평가)

  • Um, Chul Yong;Chu, Kyoung Hoon;Yun, Zu Whan;Choi, Ik Hoon;Park, Jae Young;Lee, Han Saem;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.523-532
    • /
    • 2011
  • In this study, from 2004 to 2008 influents and discharging effluents from 241 municipal public sewage treatment plants were surveyed. Statistics including average, Coefficient of Variation (CV) and Coefficient of Reliability (COR) for each season, time series analysis for removal efficiency and water quality of effluents, and a comparison of the effluent standards in Korea and other countries were presented. The average concentrations of TN and TP in influents. during winter season were 32.6 and 3.78 mg/L and during other season were 30.8 and 3.61 mg/L in 2008, respectively. The average TN concentration on the basis of the maximum monthly concentrations in the effluents during winter season ranged from 14.2~17.4 mg/L and during other season ranged from 12.2~14.8 mg/L. The TP concentration in the effluents depending on the each season was no big difference. TN removal efficiency decreased from Jan. to Feb. and TP removal efficiency decreased in Jan., Jun and July. Maximum COR during winter season were 0.61 but the COR for TN and TP during other season ranged from 0.96~1.48 and 1.09~1.81, respectively, due to big difference in the standard for TN and TP in effluents depending on the season. TN and TP standards for effluent of sewage treatment during winter season in Korea was much higher than those in other countries. Therefore the lower effluent standards during winter season is essential for the water quality improvement.

Application of hybrid material, modified sericite and pine needle extract, for blue-green algae removal in the lake

  • Choi, Hee-Jeong
    • Environmental Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.364-373
    • /
    • 2018
  • The present study assessed the efficient removal of nutrients and Chlorophyll-a (Chl-a) by using methyl esterified sericite (MES) and pine needle extracts (PNE), a low cost and abundant green hybrid material from nature. For this purpose, the optimal conditions were investigated, such as the pH, temperature, MES and PNE ratio, and MES-PNE dose. In addition, a Microcystis aeruginosa control using MES-PNE was also analyzed with various inhibition models. The removal of the nutrient and Chl-a onto MES-PNE was optimized for over 95% removal as follows: 2-2.5 for the MES-PNE ratio, 7-8 pH and a $22-25^{\circ}C$ temperature. In this respect, approximately 1.52-2.20 g/L of MES-PNE was required to remove each 1 g of dry weight/L of Chl-a. Total phosphorus (TP) has a greater influence on the increase in Chl-a than total nitrogen (TN) according to the correlation between TN, TP and Chl-a. Moreover, the Luong model was the best model for fitting the biodegradation kinetics data from Chl-a on MES-PNE from lake water. The novel hybrid material MES-PNE was very effective at removing TN, TP and Chl-a from the lake and can be applied in the field.

Application Study of small-scale sewage treatment system with A2/O precess in Mongolia (A2/O 공법을 이용한 소규모 하수처리시스템의 몽골 현지 적용에 관한 연구)

  • Yeo, Yeongki;Kim, Younghee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.431-440
    • /
    • 2017
  • The small-scale sewage treatement system with $A^2/O$ process was applied to evaluate applicability for Mongolian sewage, It was designed to have 10 m3/d flowrate and installed in Ulaanbaatar, Mongolia. During over 6month operation BOD, COD, TN, TP removal efficiency were measured and operation condition was optimized. In addition, MLSS concentration its internal circulation rate and DO were adjusted properly. BOD, COD showed average 88 perecent of removal and TN and TP achieved 81 percent and 88 percent removal efficency, respectively. Maxium influent concentration of BOD, COD, TN and TP was 214 mg/L, 300 mg/L, 24.3 mg/L and 5 mg/L respectively, which were decreased to 4.1 mg/L, 5.6 mg/L, 1.3 mg/L and 0.15 mg/L by the test system. This study show possibility tham small-scale sewage treatment system could be a useful system for scattered sewage wastewater treatment.

Treatment of Pollutants in Free Water Surface Constructed Wetlands with Lotus (Nelumbo nucifera) Cultivation Pond (연 재배지를 활용한 자유수면형 인공습지의 수질정화효율)

  • Han, Myung-Ja;Seo, Dong-Cheol;Kang, Se-Won;Lee, Yong-Chol;Bang, Seok-Bae;Chae, Jung-Heon;Kim, Kap-Soon;Park, Jong-Hwan;Chang, Nam-Ik;Heo, Jong-Soo;Cho, Ju-Sik
    • Journal of Applied Biological Chemistry
    • /
    • v.53 no.4
    • /
    • pp.232-238
    • /
    • 2010
  • In order to investigate the treatment efficiency of pollutants in free water surface constructed wetlands (FWS CWs) with lotus (Nelumbo nucifera) cultivation pond, the experiment was consisted of two sites (site I and II) in Lake Juam, Korea. The sites were configured a lotus cultivation pond (with fertilizer application) - a dropwort bed - a reed bed for site I, and a lotus cultivation pond (without fertilizer application) - a dropwort bed - a reed bed for site II. Removal rate of COD in site I and II were 13.3% and 26.0%, respectively. Removal rate of total nitrogen (TN) was 29.7% for site I, and 36.3% for site II. Removal rate of total phosphorus (TP) in site I and II were 36.0% and 36.5%, respectively. COD, TN and TP in effluent from site I (with fertilizer) was higher than that in site II (without fertilizer), showing that COD, TN and TP in effluent were strongly influenced by fertilizer addition. Therefore, in order to satisfy established water-quality standards, the amount of fertilizer used in lotus cultivation showed be evaluated.

Protozoa Structure of Anaerobic/Anoxic/Oxic Process. (혐기/무산소/호기공법의 원생동물 군집구조)

  • 이찬형;문경숙
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.3
    • /
    • pp.264-270
    • /
    • 2003
  • A quantitative survey of the protozoa microfauna at bioreactor of advanced sewage treatment plant was carried out during a period of 11 months. In this study, 32 genera were identified, including 17 ciliates. The abundance of the important protozoa were compared with the operating parameters and water quality of the effluent of the plant using statistical procedure. Statistical analysis revealed a relationship between the abundance of some genera and removal rate. In particular, correlation analysis on the quality of effluent and protozoa indicated that Lepadella may be used as the bioindicator of TP removal and Trochilia, Entosiphon, Colepus may be used as the bioindicator of TN removal when water temperature was below $20^{\circ}C$.

Parametric study of brewery wastewater effluent treatment using Chlorella vulgaris microalgae

  • Choi, Hee-Jeong
    • Environmental Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.401-408
    • /
    • 2016
  • The aim of this study was to evaluate the biomass and lipid production of Chlorella vulgaris and its nutrient removal capability for treatment of brewery wastewater effluent. The results indicate that the maximum biochemical oxygen demand (BOD) (91.43%) and chemical oxygen demand (COD) (83.11%) were removed by C. vulgaris with aeration in the absence of light. A maximum of 0.917 g/L of dry biomass was obtained with aeration in the dark conditions, which also demonstrated the highest amount of unsaturated fatty acids at 83.22%. However, the removal of total nitrogen (TN) and total phosphorus (TP) with these aeration and light conditions was 9.7% and 11.86% greater than that of other conditions. The removal of BOD and COD and the production of biomass and lipids with aeration in the dark and the TN and TP removal with aeration and light were more effective than other conditions in the brewery wastewater effluent in the presence of C. vulgaris.

A Study on the Application of Natural Zeolite as Coagulant Aid for Effluent Quality Improvement in Private Sewage Treatment Facility (개인하수처리시설 처리수의 수질 개선을 위한 응집보조제로서의 천연제올라이트 적용에 관한 연구)

  • Choi, Jung Su;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.121-128
    • /
    • 2012
  • The purpose of this study is to solve the problem of nutrient removal due to rapid hydraulic retention time (HRT) variation in small size private sewage treatment facility and to have better effluent quality by using natural zeolite as a coagulant aid. The experiments were conducted by applying different conditions of HRT, coagulant, and zeolite dosages. As an experimental result, $TBOD_{5}$, TSS, and TP removal efficiencies were 64.9%, 94.5%, and 98.8% at co-injection with zeolite. Overall removal efficiencies of $TBOD_{5}$, TSS, and TP have improved 15.7, 28.7, 6.1%, respectively. This result shows that zeolite addition could improve flocculation, increase setting velocity, and thus have better treatment. Therefore the use of zeolite as a coagulant aid can be useful in small size private sewage treatment facility, where especially extra nutrient removal is required to meet the legal standard for discharge.

Analgesic Effect of Electroacupuncture on the Pain Induced by Electrical Stimulation (전기자극에 의해 유발된 통증에 대한 말초 전침자극의 진통효과)

  • Hwang, Joon-Ha
    • The Korean Journal of Physiology
    • /
    • v.21 no.1
    • /
    • pp.79-90
    • /
    • 1987
  • The present experiment was performed in 35 normal male volunteers to evaluate the effect of electroacupuncture on the human nociception more clearly and to demonstrate the effect of different parameters of electrical stimulation through acupuncture needles. The threshold of the pain(Tp) and the nociceptive flexion reflex(Tr), the threshold for intolerable pain(Tip) and that for obtaining maximal reflex response(Tmr) were studied before and after electroacupuncture performed on the acupoints of tsusanli and hsuanchung. 1) For the pricking pain, electroacupuncture with intermittent stimulation induced a significant decrease in Tp which recovered after removal of the needles. There was no significant change in other thresholds. 2) For the dull pain, electroacupuncture with intermittent stimulation produced a significant increase in Tp which continued after removal of the needles. But there was no signifcant change in Tip. Electroacupuncture with continuous stimulation induced a slight increase in Tp. 3) After resting without electroacupuncture, Tp and Tip of the dull pain were slightly decreased. These results suggest that electroacupuncture had no significant analgesic effect on the pricking pain induced by electrical stimulation of the foot skin. However, electroacupuncture with intermittent stimulation had significant analgesic effect on the weak dull pain and it had slightly greater analgesic effect than electroacupuncture with continuous stimulation.

  • PDF

Feasibility of Aquatic Plants (Eichhornia crassipes and Water dropwort) for Nutrients Removal (수생식물(부레옥잠 및 미나리)을 이용한 영양염류 제거에 관한 연구)

  • Choi, Don-Hyeok;Kang, Ho;Lee, Mi-Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.2
    • /
    • pp.141-148
    • /
    • 2010
  • Feasibility of floating aquatic plants (Eichhornia crassipes and Water dropwort) was investigated in order to control of sewage depending on various initial loading in a lab scale test. In addition, field test was conducted to assess the uptake rate of nutrient by E. crassipes. Lab-scale test applying primary domestic effluent operated at 4 day HRT shows that the highest uptake rates were 1.06 g N/$m^2{\cdot}day$ and 0.39 g P/$m^2{\cdot}day$ in the E. crassipes reactor. BOD removal efficiency in E. crassipes reactor was as high as 80% when the loading value was lower than 185 kg BOD/$ha{\cdot}day$. While 70 ~ 80% removal efficiency of BOD was achieved when the loading value was lower 80 kg BOD/$ha{\cdot}day$ at the W. Dropwort reactor. Experiment results show that E.crassipes has a higher nutrients removal efficiency than W. dropwort under high pollutant loading. Input loadings of TN and TP should not exceed to 10 kg TN/$ha{\cdot}day$ and 2.0 kg TP/$ha{\cdot}day$ respectively to provide a 50% TN and 80% TP removal efficiencies using E. crassipes. The field test demonstrated that an annual yield of E. crassipes mass was estimated as a fresh weight of 30.9 $m^3/ha{\cdot}yr$. E. crassipes grown in field pads absorbed 76.7 kg N/$ha{\cdot}yr$ and 13.4 kg P/$ha{\cdot}yr$ as a dry weight.

Effect of Anionic Polymer on Particle Size Distribution in PAC Coagulation Process for Phosphorus Removal (PAC를 이용한 인제거 공정에서 음이온계 고분자 첨가가 입도 분포에 미치는 영향)

  • Kim, Sunghong;Lee, Dongwoo;Kim, Donghan;Kim, Dooil
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.170-175
    • /
    • 2013
  • Achieving very low phosphorus levels in treated wastewater will require the installation of additional treatment. Phosphorus removal experiments by chemical coagulation were carried out for the effluent of wastewater treatment plant in this study. TP (total phosphorus) or phosphate were highly related to the addition of PAC (poly aluminium chloride) which is one of the inorganic coagulants. But, organic polymer did not significantly affect the phosphorus removal efficiency. Polymer affected the flocculation of particle especially particle matter less than 10 micrometer so, the number of micro particles was decreased by polymer dose. Chlorination would not affect on chemical coagulation process and TP and turbidity could be effectively removed by the co-addition of PAC and polymer.