• Title/Summary/Keyword: TP Removal

Search Result 234, Processing Time 0.026 seconds

Demonstration Study of Half-Saturated Bio-filter Wetland with Recirculation Pump for Road Stormwater (반포화 순환 여과식 인공습지에 의한 도로 강우유출수의 실증처리 연구)

  • Park, Kisoo;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.259-270
    • /
    • 2017
  • In this study, field-scale half-saturated bio-filter wetland equipped with recirculation system was operated with stormwater from the paved road, and its operational performance and functions of LID-BMP were analyzed and compared with other facilities. The reduction of TSS, COD, TN, and TP were 92%, 63%, 36%, and 75%, respectively. Comparison of the reduction efficiency were carried out with respect to ratio between surface and catchment areas(SA/CA). In addition, this LID-BMP facility can reduce about 70% of pollutant by treating only 18% of total rainfall runoff. The results show that LID used for this study gave similar efficiency although its ratio was smaller. In addition, comparison study was made between synthetic fiber as a filter media and organic media, which shows that there was not any significant difference between, TSS and TP reduction, but there were large difference in COD and TN removal due to the presence and absence of release of organic carbon. Meanwhile, wetland system in this study equipped with a first-flush capture gave a higher stability in terms of treatment performance.

Constructed Wetlands in Treating Domestic and Industrial Wastewater in India: A Review (인도의 가정 및 산업 폐수 처리를 위한 인공습지: 총론)

  • Farheen, K.S.;Reyes, N.J.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.23 no.3
    • /
    • pp.242-251
    • /
    • 2021
  • Surface water pollution is a serious environmental problem in developing countries, like India, due to the unregulated discharge of untreated wastewater. To overcome this, the constructed wetlands (CWs) have been proven to be an efficient technology for wastewater treatment. In this study, different existing and experimental facilities were reviewed to be able to determine the current status of constructed wetlands in India. Based on the collected data from published literature, industrial wastewater contained the highest average chemical oxygen demand (COD), biochemical oxygen demand (BOD). In terms of total nitrogen (TN), Total phosphorous (TP), the lowest concentration was found on domestic wastewater. Vertical flow constructed wetlands (VFCW) and Horizontal flow constructed wetland (HFCW) were more effective in removing TSS, BOD, TP in domestic and industrial wastewater, whereas hybrid constructed wetlands (HCW) showed the highest removal for COD. The use of constructed wetlands as advanced wastewater treatment facilities in India yielded better water quality. The treatment of wastewater using constructed wetlands also enabled further reuse of wastewater for irrigation and other agricultural purposes. Overall, this study can be beneficial in evaluating and promoting the use of constructed wetlands in India.

Estimation of Addition and Removal Processes of Nutrients from Bottom Water in the Saemangeum Salt-Water Lake by Using Mixing Model (혼합모델을 이용한 새만금호 저층수 내 영양염의 공급과 제거에 관한 연구)

  • Jeong, Yong Hoon;Kim, Chang Shik;Yang, Jae Sam
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.4
    • /
    • pp.306-317
    • /
    • 2014
  • This study has been executed to understand the additional and removal processes of nutrients in the Saemangeum Salt-water Lake, and discussed with other monthly-collected environmental parameters such as water temperature, salinity, dissolved oxygen, suspended solids, and Chl-a from 2008 to 2010. $NO_3$-N, TP, $PO_4$-P, and DISi showed the removal processes along with the salinity gradients at the surface water of the lake, whereas $NO_2$-N, $NH_4$-N, and Chl-a showed addition trend. In the bottom water all water quality parameters except $NO_3$-N appeared addition processes indicating evidence of continuous nutrients suppliance into the bottom layer. The mixing modelling approach revealed that the biogeochemical processes in the lake consume $NO_3$-N and consequently added $NH_4$-N and $PO_4$-P to the bottom water during the summer seasons. The $NH_4$-N and $PO_4$-P appeared strong increase at the bottom water of the river-side of the lake and strong concentration gradient difference of dissolved oxygen also appeared in the same time. DISi exhibited continuous seasonal supply from spring to summer. Internal addition of $NH_4$-N and $PO_4$-P in the river-side of the lake were much higher than the dike-side, while the increase of DISi showed similar level both the dike and river sides. The temporal distribution of benthic flux for DISi indicates that addition of nutrients in the bottom water was strongly affected by other sources, for example, submarine ground-water discharge (SGD) through bottom sediment.

Operating Status and Improvement Plans of Ten Wetlands Constructed in Dam Reservoirs in Korea (국내 10개 댐저수지 인공습지의 운영현황 및 개선방안)

  • Choi, Kwangsoon;Kim, Sea Won;Kim, Dong Sup;Lee, Yosang
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.431-440
    • /
    • 2014
  • To propose the improvement and management plans to strengthen the pollutant removal efficiency of dam reservoir's constructed wetlands(CWs), the operation status and configuration of CWs (including water depth, operational flow, water flow distribution, residence time, and pollutant removal efficiency, aspect ratio, open water/vegetation ratio etc.) were analyzed in 10 major wetlands constructed in dam reservoirs. The pollutant concentrations in the inflows of the studied CWs were lower than those of American and European constructed wetlands. Especially, organic matter concentrations in all of inflows were below 3 mg/L(as BOD) due to advanced treatment of sewage disposal plant and an intake of low concentration water during dry and normal seasons. The average removal efficiency of total nitrogen(TN) and total phosphorus(TP) for 10 CWs ranged from 7.6~67.6%(mean 24.9%) and -4.9~74.5%(mean 23.7%), respectively, showing high in wetlands treating municipal wastewater. On the other hand, the removal efficiency of BOD was generally low or negative with ranging from -133.3 to 41.7%. From the analysis of the operation status and configuration of CWs, it is suggested that the low removal efficiency of dam reservoir's CWs were caused by both structural (inappropriate aspect ratio, excessive open water area) and operational (neglecting water-level management, lack of facilities and operation for first flush treatment, lake of monitoring during rainy events) problems. Therefore, to enable to play a role as a reduction facility of non-point source(NPS) pollutants, an appropriate design and operation manuals for dam reservoir's CW is urgently needed. In addition, the monitoring during rainy events, when NPS runoff occur, must be included in operation manual of CW, and then the data obtained from the monitoring is considered in estimation of the pollutant removal efficiency by dam reservoir's CW.

Treatment of N, P of Auto-Thermal Thermophilic Aerobic Digestion Filtrate with Struvite Crystallization (Struvite 결정화 반응을 이용한 고온 소화 여과액의 N, P 처리 특성)

  • Choo, Yeon-Duk;Kim, Keum-Yong;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.783-789
    • /
    • 2011
  • Recently, auto-thermal thermophilic aerobic digestion (ATAD) has a great attention for destruction of wasted sludge biomass in wastewater treatment plant. Reduction of sludge concentration has been successfully achieved with pilot scale ATAD and ceramic filtration process in field condition. However, high concentration of COD, total nitrogen (TN) and total phosphorus (TP) was observed in filtrate, which should be treated before recirculation of filtrate to biological wastewater treatment plant. This study was focused on removal of nitrogen and phosphorus contained in the filtrate of ATAD, using struvite crystallization method. The effect of operational and environmental parameters (such as, N, P and Mg ion concentration and molar ratio, pH, reaction time, agitation strength, seed dosage, and reaction temperature) on the treatment of TN and TP with struvite crystallization were evaluated. Magnesium (as $MgCl_26H_2O$) and phosphorus (as $K_2HPO_4$) ions were, if necessary, added to increase nitrogen removal efficiency by the crystal formation. Average concentration of $NH_4^+-N$ and $PO_4^{3-}-P$ of the filtrate were 1716.5 mg/L and 325.5 mg/L, respectively. Relationship between removal efficiencies of nitrogen and phosphorus and molar ratios of $Mg^{2+}$ and $PO_4^{3-}-P$ to $NH_4^+-N$ was examined. Crystal formation and nitrogen removal efficiencies were significantly increased as increasing molar ratios of magnesium and phosphorus to nitrogen. As molar ratio of $Mg^{2+}:PO_4^{3-}-P:NH_4^+-N$ were maintained to 2 : 1 : 1 and 2 : 2 : 1, removal efficiencies of nitrogen and phosphorus were 71.6% and 99.9%, and 93.8% and 98.6%, respectively. However, the effect of reaction time, mixing intensity, seed dose and temperature on the struvite crystallization reaction was not significant, comparing to those of molar ratios. Settled sludge volume after struvite crystallization was observed to be reduced with increase of seed dose and to be increased at high temperature.

Using Trophic State Index (TSI) Values to Draw Inferences Regarding Phytoplankton Limiting Factors and Seston Composition from Routine Water Quality Monitoring Data (영양상태지수 (trophic state index)를 이용한 수체 내 식물플랑크톤 제한요인 및 seston조성의 유추)

  • Havens, Karl E
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.3 s.91
    • /
    • pp.187-196
    • /
    • 2000
  • This paper describes a simple method that uses differences among Carlson's (1977) trophic state index (TSI) values based on total phosphorus (TP), chlorophyll a (CHL) and Secchi depth (SD) to draw inferences regarding the factors that are limiting to phytoplankton growth and the composition of lake seston. Examples are provided regarding seasonal and spatial patterns in a large subtropical lake (Lake Okeechobee, Florida, USA) and inter- and intra-lake variations from a multilake data set developed from published studies. Once an investigator has collected routine water quality data and established TSI values based on TP, CHL, and SD, a number of inferences can be made. Additional information can be provided where it also is possible to calculate a TSI based on total nitrogen (TN). Where TSI (CHL)<>TSI (SD), light attenuating particles are large (large filaments or colonies of algae), and the phytoplankton may be limited by zooplankton grazing. Other limiting conditions are inferred by different relationships between the TSI values. Results of this study indicate that the analysis is quite robust, and that it generally gives good agreement with conclusions based on more direct methods (e.g., nutrientaddition bioassays, zooplankton size data, zooplankton removal experiments). The TSI approach, when validated periodically with these more costly and time-intensive methods, provides an effective, low cost method for tracking long-term changes in pelagic structure and function with potential value in monitoring lake ecology and responses to management.

  • PDF

A Study on the Biosorption Process for Organic and Nutrient Removal from the Wastewater (생흡착을 이용한 하수의 유기물, 질소, 인제거에 관한 연구)

  • Kim, Hyun-Kab;Park, Ju-Seok;Chung, Hyung-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.470-479
    • /
    • 2004
  • The experimental conditions and relationships between parameters such as organic matter, aeration volume, aeration time, and precipitation time for the effective treatment of domestic wastewater were investigated. With the batch systems, the adsorption amount of unit microbe was measured with the change of MLSS concentration, precipitation time, and aeration amount. Theoretical adsorption amount of microbes was then numerically formulated by use of a SPSS multiple analysis as follows: $$Y=-0.0106(X_1)+0.07310(X_2)+42.705(X_3)+62.700$$ In this study, the amount of organisms to be removed in the range of MLSS concentration 2,000~4,500 mg/l were examined. In order to investigate the optimal condition of nitrification, the upper water in the biosorption stage was used as the initial experiment water. The results showed that the C/N ratio was 1.5 and the reaction time for the optimal nitrification was 1.5 hr. When the adsorption efficiency for microbe biosorption was 66%, the optimum denitrification efficiency was 83.3%. When the optimum parameters obtained from the batch experiment were applied to the lab-scale operation, the total retention time from the flow-in to flow-out was 10 hours and the removal efficiency was 93.8% for $COD_{cr}$ and 80.9% for TN. For the full-scale operation, the total retention time was 9.0 hours and the removal efficiency was 94.4% for BOD, 89.6% for $COD_{cr}$, 88.0% for TN, and 86.2% for TP.

Assessment on Economies-Environmental Affect of Smart Operation System(SOS) in Sewage Treatment Plant (실증규모 하수처리장에 적용된 스마트 운영시스템의 경제-환경적 기여도 평가)

  • Kim, Younkwon;Seo, InSeok;Kim, Hongsuck;Kim, Jiyeon
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.6
    • /
    • pp.581-589
    • /
    • 2013
  • Generally, Sewage Treatment Plants(STPs) are complexes systems in which a range of physical, chemical and biological processes occur. However, their performance strongly depends on the know-how acquired by the field-engineer. Recently, in order to solve this situations, various operation and management technologies based on the Instrumentation, Control and Automation(ICA) have been developed. As a economies-environmental affect point of view, this study was for the performance evaluation and assessment of results from the Smart Operation System(SOS) in full-scale STP. The SOS in STP consisted of the process monitoring module, including real-time influent prediction and effluent simulation, and the Smart Air Control(SAC) module. According to the results from field test for 2 years, the results of economical evaluation, amount of benefits and cost saving by the SOS have shown to be much higher than that of traditional operation. Nevertheless, the removal load(kg/yr) of BOD 13.3 %, COD 28.2 %, TN 44.4 % and TP 20.8 % were increased, respectively. Remarkable improvement of removal load could be achieved after the SOS was adapted. It was concerned that the SOS offer a user friendly functionalities and cost saving needed by the field-engineers. In addition, it was expected that the results of this study would supply helpful information for design and cost saving for the SOS in full-scale STP.

Purification Technology in Closed Water like a Reservoir and Pond using Oxygen Solubilized Device and Standardized Microorganism Culture System (산소용해수와 미생물제재를 이용한 호소 및 폐쇄수역의 정화기술)

  • Seo, Seong-nyeo;Kim, Young-taek;Park, Chul-hwi
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.118-124
    • /
    • 2005
  • The oxygen solubilized device(O.S.D) and standardized microorganism culture system is more efficient than physical and chemical purification techniques in closed water. This study was to determine how the O.S.D and standardized culture system is efficient in purification capacity in closed water based on the lab scale and pilot plant. In the batch test, inducing the quantitative results from pilot plant operation condition, removal efficiency of COD and TN were about 48.3% and 35% respectively, while SS and chlorophyll-a were 94.9% and 68.7%. The pilot plant results showed that suspended solid(SS) and chlorophyll-a removal efficiency were 60% and 59% respectively, due to coagulation characteristics by standardized culture. Total nitrogen(TN) and total phosphorus(TP)showed good effect for the purification of target pond water quality from field data. Additionally, released velocity was determined in control condition of $5.31mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $2486.8mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. Otherwise, phosphate and COD reflux in the aeration and microorganism condition was showed $-9.95mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $-397.88mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. This technology is the most effective not only removal of SS and chlorophyll-a but also control of phosphate and COD release which is very important phenomena in evaluating water quality in closed water like a reservoir and pond.

Water Quality Improvement in Estuary using Wetland and Pond (습지와 유수지를 이용한 하구담수호 수질개선)

  • Ham, Jong-Hwa;Yoon, Chun-Gyeong;Moon, Yong-Hyun
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.377-380
    • /
    • 2002
  • Wetland systems are widely accepted natural water purification systems around the world in nonpoint sources pollution control. In this study, the field experiment to reduce nonpoint source pollution loadings from agricultural drainage and polluted stream waters using wetland and pond system was performed. The removal rate of $BOD_5$, TSS, TN, TP, and $Chl-{\alpha}$ was 52%, 90%, 56%, 59%, and 81%, respectively. Performance of the experimental system was compared with existing data base (NADB), and it was within the range of general system performance. Overall the water quality improvement was apparent in wetland and pond system.

  • PDF