• Title/Summary/Keyword: TOF system

Search Result 159, Processing Time 0.024 seconds

Development and Applications of TOF-MEIS (Time-of-Flight - Medium Energy Ion Scattering Spectrometry)

  • Yu, K.S.;Kim, Wansup;Park, Kyungsu;Min, Won Ja;Moon, DaeWon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.107.1-107.1
    • /
    • 2014
  • We have developed and commercialize a time-of-flight - medium energy ion scattering spectrometry (TOF-MEIS) system (model MEIS-K120). MEIS-K120 adapted a large solid acceptance angle detector that results in high collection efficiency, minimized ion beam damage while maintaining a similar energy resolution. In addition, TOF analyzer regards neutrals same to ions which removes the ion neutralization problems in absolute quantitative analysis. A TOF-MEIS system achieves $7{\times}10^{-3}$ energy resolution by utilizing a pulsed ion beam with a pulse width 350 ps and a TOF delay-line-detector with a time resolution of about 85 ps. TOF-MEIS spectra were obtained using 100 keV $He^+$ ions with an ion beam diameter of $10{\mu}m$ with ion dose $1{\times}10^{16}$ in ordinary experimental condition. Among TOF-MEIS applications, we report the quantitative compositional profiling of 3~5 nm CdSe/ZnS QDs, As depth profile and substitutional As ratio of As implanted/annealed Si, Ionic Critical Dimension (CD) for FinFET, Direct Recoil (DR) analysis of hydrogen in diamond like carbon (DLC) and InxGayZnzOn on glass substrate.

  • PDF

236U accelerator mass spectrometry with a time-of-flight and energy detection system

  • Li Zheng;Hiroyuki Matsuzaki;Takeyasu Yamagata
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4636-4643
    • /
    • 2022
  • A time-of-flight and energy (TOF-E) detection system for the measurement of 236U accelerator mass spectrometry (AMS) has been developed to improve the 236U/238U sensitivity at Micro Analysis Laboratory, Tandem accelerator (MALT), The University of Tokyo. With observing TOF distribution of 235U, 236U and 238U, this TOF-E detection system has clearly separated 236U from the interference of 235U and 238U when measuring three kinds of uranium standards. In addition, we have developed a novel method combining kernel-based density estimation method and multi-Gaussian fitting method to estimate the 236U/238U sensitivity of the TOF-E detection system. Using this new estimation method, 3.4 × 10-12 of 236U/238U sensitivity and 1.9 ns of time resolution are obtained. 236U/238U sensitivity of TOF-E detection system has improved two orders of magnitude better than that of previous gas ionization chamber. Moreover, unknown species other than uranium isotopes were also observed in the measurement of a surface soil sample, which has demonstrated that TOF-E detection system has a higher sensitivity in particle identification. With its high sensibility in mass determination, this TOF-E detection system could also be used in other heavy isotope AMS.

Development of neutron time-of-flight measurement system for 1.7-MV tandem proton accelerator with lithium target

  • Lim, Soobin;Kim, Donghwan;Kang, Jin-Goo;Dang, Jeong-Jeung;Lee, Pilsoo;Kim, Geehyun;Chung, Kyoung-Jae;Hwang, Y.S.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.437-441
    • /
    • 2022
  • In this study, we developed a neutron time-of-flight (nTOF) measurement system for a 1.7-MV tandem proton accelerator with a target covered with 300-nm-thick lithium (Li) layer. With implementation of beam chopping module after its ion source, the accelerator is configured to operate in pulsed-beam mode with a pulse width <50 ns at 20-kHz repetition rate. This enables the gamma flash-type nTOF measurement system to identify the neutron generated with 3-MeV proton beam energy. The nTOF system consists of a 30" cylindrical NaI(Tl) and four stilbene scintillation detectors. The NaI(Tl) scintillator is placed 50 cm from the Li target to measure the time of beam irradiation on the target, and the stilbene detectors are placed 2 and 2.4 m away to measure nTOF at each location. The nTOF system successfully measured the generated neutron energy at irradiated proton energies of 2.6 and 3.0 MeV with an average energy resolution of 15%.

Measuring ultrasonic TOF using Zynq baremetal Multiprocessing (Zynq 기반 baremetal 멀티프로세싱에 의한 초음파 TOF 측정)

  • Kang, Moon ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.6
    • /
    • pp.93-99
    • /
    • 2017
  • In this research the TOF (time of flight) of ultrasonic signal is measured using Xilinx's Zynq SoC (system on chip). The TOF is calculated from the difference between periods during which RF (radio frequency) and ultrasonic signals come across a distance, and then travelling distance is obtained by multiplying the TOF by the ultrasonic speed in the air. For this purpose, a ultrasonic pulse is generated from a Zynq's internal ADC, a FIR (finite impulse response) filter, and a Kalman filter. And a RF reference pulse is generated from a RF interface. Based on baremetal multiprocessing, the Kalman filter and the RF interface are c-programmed on Zynq's dual processor cores, with other components fabricated on Zynq's FPGA. With this HW/SW co-design, both lower resource utilization and much smaller designing period were obtained than the HW design. As a design tool, Vivado IDE(integrated design environment) is used to design the whole signal processing system in hierarchical block diagrams.

3D Fingertip Estimation based on the TOF Camera for Virtual Touch Screen System (가상 터치스크린 시스템을 위한 TOF 카메라 기반 3차원 손 끝 추정)

  • Kim, Min-Wook;Ahn, Yang-Keun;Jung, Kwang-Mo;Lee, Chil-Woo
    • The KIPS Transactions:PartB
    • /
    • v.17B no.4
    • /
    • pp.287-294
    • /
    • 2010
  • TOF technique is one of the skills that can obtain the object's 3D depth information. But depth image has low resolution and fingertip occupy very small region, so, it is difficult to find the precise fingertip's 3D information by only using depth image from TOF camera. In this paper, we estimate fingertip's 3D location using Arm Model and reliable hand's 3D location information that is modified by hexahedron as hand model. Using proposed method we can obtain more precise fingertip's 3D information than using only depth image.

Verification with of High Efficiency Chemical Binding System of a Physiologically Active Radioisotope Using ESI-TOF/Ms System (고효율의 ESI-TOF/Ms 시스템을 이용한 생리활성 항체와 방사성동위원소 표지용 착화제의 결합 검증)

  • Joh, Eun-Ha;Hong, Young Don;Choi, Sun Ju
    • YAKHAK HOEJI
    • /
    • v.57 no.6
    • /
    • pp.400-405
    • /
    • 2013
  • In this study, we measured the complex efficiency of a physiologically active antibody, a chelator and radiosiotopes using the ESI-TOF/Ms system for develop good radiopharmaceuticals. For a precise measurement, TLC is a low accuracy method. Loading of same amount of sample is difficult for each test, and work to quantify accurately the results obtained through TLC cannot be afforded compared to the use of other analytical instruments. The method of analysis using a mass spectrometer is capable of a mass analysis of proteins for quantitative analysis. The conjugates of the chelator (CHX-A- DTPA) and the antibody (IgG) were separated through MWCO, and were analyzed using ESI-TOF and MALDI-TOF mass spectrometry. The analysis using MALDI-TOF is roughly divided into measurements on mass spectrometry. When conjugating a small molecular weight of CHX-A-DTPA and a large molecular weight of IgG, distinguishing the peak of the conjugate and the peak of IgG was difficult. However, an ESI-TOF mass spectrometer system is capable of an analysis of mass by decentralizing the IgG. It is utilized as a technique for measuring the metabolic processes during conjugation and the stability evaluation of radiopharmaceuticals. When establishing this technique, the accuracy of the overall radiophar-maceutical analysis is expected to be able to be improved.

Construction of an Improved Tandem Time-of-flight Mass Spectrometer for Photodissociation of Ions Generated by Matrix-assisted Laser Desorption Ionization (MALDI)

  • Moon, Jeong-Hee;Yoon, So-Hee;Kim, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.5
    • /
    • pp.763-768
    • /
    • 2005
  • An improved tandem time-of-flight (TOF) mass spectrometer for the photodissociation (PD) study of ions generated by matrix-assisted laser desorption ionization (MALDI), MALDI-TOF-PD-TOF, has been designed and constructed. Recording a full spectrum with better than unit mass resolution even in low mass range has been achieved without reflectron voltage stepping which was needed in the previous version. Other aspects of the improvement, such as those in the data system which now allow 10-100 times faster spectral acquisition than with the previous instrument, are described. Rationale for the ideas which have led to the improvements is presented also.

Quantitative Analysis of Fluid Velocity and Signal Loss of the TOF-MRA in a 3.0T MR System: Using the Flow Rate Control Phantom (3.0T MR system에서 TOF-MRA의 유체속도와 신호소실의 정량분석 : 유속조절팬텀 이용)

  • Back, Sang-Hoon;Jeong, Jin-Heon;Lee, Ye-Eun;Gwak, Min-Young;Yoon, Jun;Jung, Dabin;Oh, Hyun-Sik;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.965-973
    • /
    • 2020
  • The purpose of this study was to quantitatively correlate the change of flow velocity and signal voiding in TOF-MRA. We made our phantom to control the flow velocity, and changed the flow velocity in 16 steps from 8.0 to 127.3 mc/s. The TOF-MRA test was performed using a 3.0T MRI system and the signal intensity was measured by classifying the signal voiding length and image into the In flow, Mid flow, and Out flow. The length of signal voiding was the longest when the flow velocity was 127.3 cm/s and the signal intensity decreased with increasing flow velocity(p<0.05). In flow(-.547) and Mid flow(-.643) were negatively correlated with flow velocitys(p<0.05). In conclusion, it was confirmed that the increase in flow velocity was a major factor causing signal voiding in TOF-MRA. In the future, this study will provide basic data when studying sequences and parameters to reduce signal voiding in models with a high flow velocity.

Usefulness estimating of Time of flight(TOF) during Carotid angio inspection including Aortic arch (Aortic arch를 포함한 Carotid angio 검사 시 Time of flight(TOF)의 유용성 평가)

  • Yoo, Yeong-Jun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The Carotid Angio inspection including Aortic arch applied to wide area is conducted as the Contrast Enhance MR Angiography(CEA) which is using a contrast medium. However it is a burden not only for someone such as infants, pregnant women and patients suffering from kidney failure but continuous use of contrast medium also can be a burden for patients who has been taken follow up inspection since diagnose lesion already. The purpose of this study is to estimate a usefulness of the Time of Flight (TOF) by comparing with CEA. Materials and methods : 10 patients with an average age of 58 (from 45 to 75) who had MRA inspection in our hospital were studied using 3.0 Tesla Aachieva (Philips, Netherland) MRI system and Sense Neuro-Vascular 16 Channels Coil. The same patient was inspected both TOF and CEA simultaneously. The TOF inspection included from Aortic arch to Willis Circle by connecting 3 TOF stacks and so did CEA inspection. The quantitative analysis was conducted through signal to noise ratio(SNR) and contrast to noise ratio(CNR) with soft tissue by setting up an area of interest on CCA bifurcatoin, ICA, ECA, MCA and VA concerning obtained image. In case of qualitative analysis, 3 radiological technologists and 1 radiologist evaluated 4 items (1: Visibility of the blood vessel, 2: Image distortion measure, 3: Overlapping measure with vein, 4: Peripheral blood vessel description measure) into five points scale (1: Very bad, 2: Bad, 3: Normal 4: Good, 5: Very good). Results : Results for the quantitative analysis was obtained by calculating the average of 5 ROIs in case of SNR and CNR separately. Results of SNR, TOF were generally measured higher than CEA (In case of TOF were 166.1, 205.2, 154.39, 172.23, 161.95, and CEA were 92.05, 95.43, 84.76, 73.69, 88.3). But according to the result of CNR, both TOF and CEA were measured similarly as 67.62, 106.71, 55.9, 73.74, 63.46 for TOF and 67.82, 71.19, 60.52, 49.45, 64.07 for CEA. Throughout every results of each ROI, SNR showed statistically meaningful consequence (0.050.05). In case of qualitative analysis the average of each evaluated item was 4.2points and 4.28points in the item1, 2.93points and 4.55points in the item2, 4.6points and 3.13points in the item3, 2.88points and 4.6points in the item4. According to the results TOF was measured higher in the item3 while in the item2 and item4 CEA was higher and in case of the item1, both CEA and TOF were similar. To sum up statistically meaningful results (p<0.05) were shown in the item2, item3 and item4 but not in the item1 (p>0.05). Conclusions : Both TOF and CEA are complementary because each inspection has pros and cons, but when inspect wide area including Aortic arch normally CEA is conducted. But TOF inspection also can be considered as alternative in terms of patients who has difficulty in the contrast medium such as infants, pregnant women and patients suffering from kidney failure and patients during follow up.

  • PDF

Precise Measurement of Beam Energy and Range with TOF and Counter Telescope System

  • Nanbu, Shuya;Kanai, Tatsuaki;Kohno, Toshiyuki;Ohno, Yumiko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.225-227
    • /
    • 2002
  • In order to improve the accuracy of charged-particle radiation therapy, the beam energy was measured precisely using a TOF-system, and the range using a counter telescope system. A Si detector and a Ge detector were used to estimate the range straggling as a $\Delta$E and an E detector, respectively, because they have good energy resolution and the output pulse heights don't depend on the atomic number of detected particles. The results were compared with the theoretical values by a calculation code.

  • PDF