• Title/Summary/Keyword: TOF method

Search Result 262, Processing Time 0.031 seconds

The Usefulness of 3T-TOF MR angiography in Patients with Cerebral Infarction (뇌졸중 환자에서 3 Tesla 자기공명혈관조영술의 유용성)

  • Han, Je-Hee;Chung, Tae-Woong;Yoon, Woong;Jang, Nan-Kyu;Shin, Sang-Soo;Lim, Hyo-Soon;Song, Sang-Gook;Jeong, Yong-Yeon;Kang, Heoung-Keun;Seo, Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.94-100
    • /
    • 2005
  • Purpose : This study was designed to evaluate the usefulness of 3T-TOF MR angiography (3T-TOF MRA) compared with transcranial Doppler sonography (TCD) and conventional angiography (CA) in patients with suspected cerebral infarction. Materials and Methods : Fifty four patients with clinical symptoms of cerebral infarction were involved in this study, and had undergone 3T-TOF MRA and TCD, with CA in 11 patients. On the basis of divisions of the carotid artery, four groups were designated: group I, both vertebral arteries and basilar artery; group II, segment between 2 cm below bifurcation of common carotid artery and genu portion of internal carotid artery; group III, segment between petrous portion of internal carotid artery and bifurcation of anterior and middle cerebral artery; group IV, from bifurcation of anterior and middle cerebral artery to thier distal branches. Two radiologists retrospectively reviewed the vascular imaging and stenosis in 3T-TOF MRA, TCD, and CA. Results : A total of 432 arteries, 108 in each group, were available. The assessment of vascular imaging quality in 3T-TOF MRA is scored 2.98, 2.96, 2.91, 2.88 in 4 groups, respectively. Agreement among 3T-TOF MR angiography, TCD, and CA was high. Conclusion : 3T-TOF MR angiography may be useful method for the assessment of stenotic lesions of cranial vasculature in patients with cerebral infarction.

  • PDF

Discrimination of Bacillus anthracis Spores by Direct in-situ Analysis of Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight Mass Spectrometry

  • Jeong, Young-Su;Lee, Jonghee;Kim, Seong-Joo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2635-2639
    • /
    • 2013
  • The rapid and accurate identification of biological agents is a critical step in the case of bio-terror and biological warfare attacks. Recently, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry has been widely used for the identification of microorganisms. In this study, we describe a method for the rapid and accurate discrimination of Bacillus anthracis spores using MALDI-TOF MS. Our direct in-situ analysis of MALDI-TOF MS does not involve subsequent high-resolution mass analyses and sample preparation steps. This method allowed the detection of species-specific biomarkers from each Bacillus spores. Especially, B. anthracis spores had specific biomarker peaks at 2503, 3089, 3376, 6684, 6698, 6753, and 6840 m/z. Cluster and PCA analyses of the mass spectra of Bacillus spores revealed distinctively separated clusters and within-groups similarity. Therefore, we believe that this method is effective in the real-time identification of biological warfare agents such as B. anthracis as well as other microorganisms in the field.

SELDI-TOF MS Combined with Magnetic Beads for Detecting Serum Protein Biomarkers and Establishment of a Boosting Decision Tree Model for Diagnosis of Pancreatic Cancer

  • Qian, Jing-Yi;Mou, Si-Hua;Liu, Chi-Bo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.1911-1915
    • /
    • 2012
  • Aim: New technologies for the early detection of pancreatic cancer (PC) are urgently needed. The aim of the present study was to screen for the potential protein biomarkers in serum using proteomic fingerprint technology. Methods: Magnetic beads combined with surface-enhanced laser desorption/ionization (SELDI) TOF MS were used to profile and compare the protein spectra of serum samples from 85 patients with pancreatic cancer, 50 patients with acute-on-chronic pancreatitis and 98 healthy blood donors. Proteomic patterns associated with pancreatic cancer were identified with Biomarker Patterns Software. Results: A total of 37 differential m/z peaks were identified that were related to PC (P < 0.01). A tree model of biomarkers was constructed with the software based on the three biomarkers (7762 Da, 8560 Da, 11654 Da), this showing excellent separation between pancreatic cancer and non-cancer., with a sensitivity of 93.3% and a specificity of 95.6%. Blind test data showed a sensitivity of 88% and a specificity of 91.4%. Conclusions: The results suggested that serum biomarkers for pancreatic cancer can be detected using SELDI-TOF-MS combined with magnetic beads. Application of combined biomarkers may provide a powerful and reliable diagnostic method for pancreatic cancer with a high sensitivity and specificity.

The Research to Correct Overestimation in TOF-MRA for Severity of Cerebrovascular Stenosis (3D-SPACE T2 기법에 의한 TOF-MRA검사 시 발생하는 혈관 내 협착 정도의 측정 오류 개선에 관한 연구)

  • Han, Yong Su;Kim, Ho Chul;Lee, Dong Young;Lee, Su Cheol;Ha, Seung Han;Kim, Min Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.180-188
    • /
    • 2014
  • It is very important accurate diagnosis and quick treatment in cerebrovascular disease, i.e. stenosis or occlusion that could be caused by risk factors such as poor dietary habits, insufficient exercise, and obesity. Time-of-flight magnetic resonance angiography (TOF-MRA), it is well known as diagnostic method without using contrast agent for cerebrovascular disease, is the most representative and reliable technique. Nevertheless, it still has measurement errors (also known as overestimation) for length of stenosis and area of occlusion in celebral infarction that is built by accumulation and rupture of plaques generated by hemodynamic turbulence. The purpose of this study is to show clinical trial feasibility for 3D-SPACE T2, which is improved by using signal attenuation effects of fluid velocity, in diagnosis of cerebrovascular disease. To model angiostenosis, strictures of different proportions (40%, 50%, 60%, and 70%) and virtual blood stream (normal saline) of different velocities (0.19 ml/sec, 1.5 ml/sec, 2.1 ml/sec, and 2.6 ml/sec) by using dialysis were made. Cross-examinations were performed for 3D-SPACE T2 and TOF-MRA (16 times each). The accuracy of measurement for length of stenosis was compared in all experimental conditions. 3D-SPACE 2T has superiority in terms of accuracy for measurements of the length of stenosis, compared with TOF-MRA. Also, it is robust in fast blood stream and large stenosis than TOF-MRA. 3D-SPACE 2T will be promising technique to increase diagnosis accuracy in narrow complex lesions as like two cerebral small vessels with stenosis, created by hemodynamic turbulence.

Analysis of Branched PEG-Conjugated Interferon Alpha by Capillary Electrophoresis and MALDI- TOF Mass Spectrometry

  • Na, Dong-Hee;Park, Eun-Ji;Lee, Snag-Deuk;Jo, Young-Woo;Lee, Sung-Hee;Kim, Won-Bae;Lee, Kang-Choon
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.406.3-407
    • /
    • 2002
  • Analysis of interferon alpha (IFN) modified with high molecular weight branched PEG was performed by capillary electrophoresis (CE) and MALDI-TOF mass spectrometry (MALDI-TOF MS). IFN was modified by the reaction of amine residues with an active ester of monomethoxy polyethylene glycol at various molar ratios. As a CE method. capilary electrophoresis sodium dodecyl sulfate nongel sieving (CE-SDS NGS) was performed using an uncoated capilary filled with a hydrophilic replaceable polymer network matrix. (omitted)

  • PDF

Diagnosis of Subclavian Steal: Contrast Enhanced 3D MR Angiography vs 2D TOF

  • 이호규;김건언;최중곤;서대철
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.136-136
    • /
    • 2001
  • Purpose: Subclavian steal refers to the retrograde flow of blood in a vertebral artery that supplies t ipsilateral shoulder and arm caused by proximal subclavian artery stenosis or occlusion. T purpose of this exhibit is to demonstrate MR findings of subclavian steal on contrast-enhanc 3D (CE 3DMRA) and 2D TOF MR angiography. Method: Four patients(men 3 and women 1, age: 28-78years) with subclavian steal obtained both CE 3DMRA and digital subtraction angiography(DSA) including subclavian arterie Sequential imaging was undertaken during first pass after double dose of Gd-DTPA (0 mM/kg) Injected by a power injector. Coronal source images were obtained with coronal D-fast low angle shot sequence(TR/TE/flip angle=3.8/l.3/35, acquisition time= 10sec/one measurement). Precontrast imaging was subtracted from enhanced images and maximu intensity projection was done. 2D time-of-flight MR angiography(2D TOF) of the carot bifurcation was added in all cases with post-saturation. All studies were review retrospectively.

  • PDF

Metabolomics Approach for Classification of Medicinal Plants

  • Lee, Dong-Ho
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.5-5
    • /
    • 2010
  • Selection of specific medicinal sources as well as bioactive compounds is important for the preparation of medicine and related products with good quality. It is necessary to pay close attention for choosing correct medicinal sources, particularly in case of medicinal plants, because of their diversity, which can affect the quality and efficacy of medicine. Discrimination of plants based on morphological or genetic characteristics has been used as a conventional classification method of pharmaceutical sources so far; however, more need demands more general methods for accurate quality assessment of medicinal plants. In this study, ultra performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/Q-TOF MS) technique applied to this metabolic profiling is a powerful tool due to its higher sensitivity, resolution, and speed compared to conventional HPLC technique. The metabolite profiling of several medicinal plants including Panax ginseng was carried out using UPLC/Q-TOF MS and total metabolites were then subsequently applied to various statistical tools to compare the patterns. The developed metabolomics tool with UPLC/Q-TOF MS successfully identified and classified the samples tested according to their origins.

  • PDF

Selective Extraction and Quantification of Glutathione using Maleimide-Presenting Gold Nanoparticles

  • Oh, Hongseok;Lee, Jeongwook;Yeo, Woon-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.10
    • /
    • pp.3047-3051
    • /
    • 2014
  • In this paper, we describe a new method for the selective extraction and quantification of glutathione (GSH) using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and maleimide-presenting gold nanoparticles (Mal-AuNPs). Our strategy utilizes the Michael addition to selectively extract GSH, from chosen samples, onto the maleimide of Mal-AuNPs. After the extraction step, the GSH bound to the AuNPs was analyzed by MALDI-TOF MS in the presence of an internal standard which was prepared by reacting Mal-AuNPs with isotope-labeled GSH ($GSH^*$). The $GSH^*$ has the same structure as GSH but a higher molecular weight, and therefore, enables absolute quantification of GSH by comparing the mass signal intensities of the GSH- and $GSH^*$-conjugated alkanethiols. Our strategy was verified by analyzing GSH-spiked fetal bovine serum and NIH 3T3 cells.

The study for the synthesis and analysis of metal chelated protein (단백질의 메탈 킬레이션 화합물 제조 및 확인에 관한 연구)

  • Kim, Sung-Ho;Nam, Hae-Seon;Lee, Yoon-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1273-1278
    • /
    • 2007
  • In living system, various types of metal chelated protein show their intrinsic biological activities. In order to investigate the chelation reaction between protein and metal, zinc chelated peptide was systhesized by the peptide, hydrolyzed protein, with zinc. And simple analytical method fot the chelation reaction was developed using MALDI-TOF mass spectrometry.

  • PDF

Analysis of Electron Energy Distribution Function and Transport Characteristic in SiH$_4$ Gas Plasma by MCS-BE Method (MCS-BE법을 이용한 SiH$_4$가스 프라즈마중의 전자에너지분포함수와 수송특성해석)

  • 이형윤;하성철;유회영;김상남;임상원;문기석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.154-159
    • /
    • 1997
  • This paper describes the electron transport characteristic in SiH$_4$ gas calculated for range of E/N values from 0.5~300(Td) by the Monte Calro simulation and Boltzmann equation method using a set of electron collision cross sections determined by the authors and the values of electron swarm parameters are obtained for TOF method. The results gained that the value of an electron swarm parameter such as the electron drift velocity, the electron ionization coefficients longitudinal and transverse diffusion coefficients, characteristics energy agree with thee experimental and theoretical for a range of E/N. The electron energy distributions function were analysed in monosilane at EN : 30, 50(Td) for a case of equilibrium region in the mean electron energy. The validity of the results obtained has been confirmed by a TOF method.

  • PDF