• Title/Summary/Keyword: TN-C

Search Result 388, Processing Time 0.034 seconds

Environmental impact of hydroponic nutrient wastewater, used hydroponic growing media, and crop wastes from acyclic hydroponic farming system (비순환식 양액재배에서 발생하는 폐양액, 폐배지, 폐작물이 환경에 미치는 영향)

  • Park, Bounglog;Cho, Hongmok;Kim, Minsang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2021
  • Hydroponic farming is a method to grow a plant without soil. Plants can be grown on water or hydroponic growing media, and they are fed with mineral nutrient solutions, which are fertilizers dissolved into water. Hydroponic farming has the advantage of increasing plant productivity over conventional greenhouse farming. Previous studies of hydroponic nutrient wastewater from acyclic hydroponic farms pointed out that hydroponic nutrient wastewater contained residual nutrients, and they were drained to a nearby river bank which causes several environmental issues. Also, previous studies suggest that excessive use of the nutrient solution and disposal of used hydroponic growing media and crop wastes in hydroponic farms are major problems to hydroponic farming. This study was conducted to determine the impact of hydroponic nutrient wastewater, used hydroponic growing media, and crop wastes from acyclic hydroponic farms on the surrounding environment by analyzing water quality and soil analysis of the above three factors. Three soil cultivation farms and several hydroponic farms in the Gangwon C region were selected for this study. Samples of water and soils were collected from both inside and outside of each farm. Also, a sample of soil and leachate from crop waste piles stacked near the farm was collected for analysis. Hydroponic nutrient wastewater from acyclic hydroponic farm contained an average of 402 mg/L of total nitrogen (TN) concentration, and 77.4 mg/L of total phosphate (TP) concentration. The result of TP in hydroponic nutrient wastewater exceeds the living environmental standard of the river in enforcement decree of the framework act on environmental policy by 993.7 times. Also, it exceeds the standard of industrial wastewater discharge standards under the water environment conservation act by 6~19 times in TN, and 2~27 times in TP. Leachate from crop waste piles contained 11,828 times higher COD and 395~2662 times higher TP than the standard set by the living environmental standard of the river in enforcement decree of the framework act on environmental policy and exceeds 778 times higher TN and 5 times higher TP than the standard of industrial wastewater discharge standards under the water environment conservation act. For more precise studies of the impact of hydroponic nutrient wastewater, used hydroponic growing media, and crop wastes from acyclic hydroponic farms on the surrounding environment, additional information regarding a number of hydroponic farms, arable area(ha), hydroponic farming area, seasonal, weather, climate factor around the river, and the property of the area and farm is needed. Analysis of these factors and additional water and soil samples are needed for future studies.

ISOLATION, IDENTIFICATION AND CHARACTERIZATION OF AN IMMOBILIZED BACTERIUM PRODUCING N2 FROM NH4+ UNDER AN AEROBIC CONDITION

  • Park, Kyoung-Joo;Cho, Kyoung-Sook;Kim, Jeong-Bo;Lee, Min-Gyu;Lee, Byung-Hun;Hong, Young-Ki;Kim, Joong-Kyun
    • Environmental Engineering Research
    • /
    • v.10 no.5
    • /
    • pp.213-226
    • /
    • 2005
  • To treat wastewater efficiently by a one-step process of nitrogen removal, a new bacterial strain producing $N_2$ gas from ${NH_4}^+$ under an aerobic condition was isolated and identified. The cell was motile and a Gram-negative rod, and usually occurred in pairs. By 16S-rDNA analysis, the isolated strain was identified as Enterobacter asburiae with 96% similarity. The isolate showed that the capacity of $N_2$ production under an oxic condition was approximately three times higher than that under an anoxic condition. Thus, the consumption of ${NH_4}^+$ by the isolate was significantly different in the metabolism of $N_2$ production under the two different environmental conditions. The optimal conditions of the immobilized isolate for $N_2$ production were found to be pH 7.0, $30^{\circ}C$ and C/N ratio 5, respectively. Under all the optimum reaction conditions, $N_2$ production by the immobilized isolate resulted in reduction of ORP with both the consumption of DO and the drop of pH. The removal efficiencies of $COD_{Cr}$, and TN were 56.1 and 60.9%, respectively. The removal rates of $COD_{Cr}$, and TN were the highest for the first 2.5 hrs with the removal $COD_{Cr}/TN$ ratios of 32.1, and afterwards the rates decreased as reaction proceeded. For application of the immobilized isolate to a practical process of ammonium removal, a continuous operation was executed with a synthetic medium of a low C/N ratio. The continuous bioreactor system exhibited a satisfactory performance at 12.1 hrs of HRT, in which the effluent concentrations of ${NH_4}^+$-N was measured to be 15.4 mg/L with its removal efficiency of 56.0%. The maximum removal rate of ${NH_4}^+$-N reached 1.6 mg ${NH_4}^+$-N/L/hr at 12.1 hrs of HRT(with N loading rate of $0.08\;Kg-N/m^3$-carrier/d). As a result, the application of the immobilized isolate appears a viable alternative to the nitrification-denitrification processes.

Variances of Environmental Factors during Water Bloom by Microcystis aeruginosa (K$\ddot{u}$tzing) K$\ddot{u}$tzing in Ilwol Reservoir, Suwon (수원 일월저수지에서 Microcystis aeruginosa (K$\ddot{u}$tzing) K$\ddot{u}$tzing 수화현상 시 환경요인들의 변화)

  • Kim, Ji-Eun;Park, Jung-Won;Jo, Ki-An;Kim, Si-Kyoon
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.2
    • /
    • pp.265-275
    • /
    • 2013
  • Variances in environmental factors were followed in Ilwol reservoir, Suwon, during bloom of Microcystis aeruginosa (K$\ddot{u}$tzing) K$\ddot{u}$tzing, Cyanophtya from August to October, 2011. M. aeruginosa dominated the water column throughout the investigation period. The water temperature varied from $25.7^{\circ}C$ to $28.4^{\circ}C$, pH 8.40 to 11.17, CODcr 4.25 to $72.00mg\;L^{-1}$, electrical conductivity 333.1 to $749.0{\mu}g\;cm^{-1}$, and Chl-a 22 to $185mg\;L^{-1}$. In particular, the high levels of CODcr is likely indicate high contribution of autochthonous organic matters in the reservoir. TN varied from 28.86 to $56.75mg\;L^{-1}$, TP 0.20 to $1.24mg\;L^{-1}$, Fe 0.11 to $1.05mg\;L^{-1}$, and Si 3.13 to $7.46mg\;L^{-1}$. These increases imply constant accumulation in Ilwol reservior, and reinforce the idea of autochthonous organic matters input in the reservoir. The Korea Trophic Status Index ($TSI_KO$) varied from 37.19 to 147.22. Trophic levels varied from mesotrophic to hypertrophic level, and differed spatio-temporally. Therefore, it is concluded that $TSI_KO$ is useful for analyzing trophic status of reservoirs.

Construction of Recombinant Xanthomonas campestris Strain Producing Insecticidal Protein of Bacillus thuringiensis

  • Shin, Byung-Sik;Koo, Bon-Tag;Choi, Soo-Keun;Park, Seung-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.4 no.4
    • /
    • pp.285-289
    • /
    • 1994
  • An insecticidal crystal protein gene, cryIA(c), from Bacillus thuringiensis HD-73 was integrated into the chromosome of a xanthan-producing bacterium, Xanthomonas campestris XP92. The cryIA(c) gene expression cassette was constructed that placed the gene between the trc promoter and rrnB transcriptional terminator. The $lacl^q$ gene was also included to prevent the expression of cryIA(c) gene in X campestris cells. Southem blot analysis confirmed the integration of the cryIA(c) gene expression cassette in chromosome of X campestris XP92 transconjugant. Expression of the insecticidal crystal protein was confirmed by Western blot analysis and bioassay against the larvae of Hyphantria cunea (Lepidoptera: Arctiidae) and Plutella xylostella (Lepidoptera:Plutellidae).

  • PDF

A Study on the Effective Surge Protection Method from Induced Lightning Surgeto Improve Isolate Grounding to Common Grounding (낙뢰 Surge 방호를 위한, 독립접지를 공통접지로 개선하는 효율적인 방법에 대한 연구)

  • Jeon, Hyung-Gu;Woo, Jea-Wook;Suh, Yong-Joon
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1459-1467
    • /
    • 2011
  • This paper proposes the effective method to improve the protection from induced lightning Surge by making common grounding from individual grounding. Common grounding under equipotential principle is more effective than individual grounding for lightning Surge protection, and so common grounding is indicated as international technical standard under the AC power supply system with neutral line. So, this paper is to propose the effective way of induced lightning Surge protection method for currently installed power supply system which has no neutral grounded line and individual grounding which are weak for lightning Surge protection. This proposal can improve the power supply system as has neutral line, and improve the grounding system to common grounding system. And also this paper proposes to make effective equipotential system with voltage variable shunting devices for lightning Surge protection.

  • PDF

Application of the Thermophilic Aerobic Oxidation (TAO) System to Anaerobic Digestate Stabilization in Korea (혐기소화액의 고온호기산화 공정 적용에 관한 연구)

  • Kim, Soo-Ryang;Kim, Ha-Je;Nizel, Halder Joshua;Rhee, Ji-Hae;Shin, Myoung-Chul;Kim, Tae-Ha;Lee, Myung-Gyu
    • Journal of Animal Environmental Science
    • /
    • v.21 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • We studied the possibility on the application of the Thermophilic Aerobic Oxidation (TAO) process to anaerobic digestate stabilization. In treating digestate with TAO reactor the internal temperature of the reactor was increasing higher and $51^{\circ}C$ and over was maintained after 6 days on. The physiochemical compositions of liquids increased from pH 8.1 to 9.8 and EC decreased from 29.8 to 12.0 mS/cm in treating process of digestate with TAO reactor. CODcr decreased from 22,654 to 18,843 mg/L, showed about 16.82% of remove efficiency. TN and $NH_4-N$ decreased from 4,813 to 1,733 mg/L, from 3,815 to 812 mg/L respectively, which showed about 64.0% and 78.7% of removal efficiency respectively.

Effect of Algal Inoculation on COD and Nitrogen Removal, and Indigenous Bacterial Dynamics in Municipal Wastewater

  • Lee, Jangho;Lee, Jaejin;Shukla, Sudheer Kumar;Park, Joonhong;Lee, Tae Kwon
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.5
    • /
    • pp.900-908
    • /
    • 2016
  • The effects of algal inoculation on chemical oxygen demand (COD) and total nitrogen (TN) removal, and indigenous bacterial dynamics were investigated in municipal wastewater. Experiments were conducted with municipal wastewater inoculated with either Chlorella vulgaris AG10032, Selenastrum gracile UTEX 325, or Scenedesmus quadricauda AG 10308. C. vulgaris and S. gracile as fast growing algae in municipal wastewater, performed high COD and TN removal in contrast to Sc. quadricauda. The indigenous bacterial dynamics revealed by 16S rRNA gene amplification showed different bacterial shifts in response to different algal inoculations. The dominant bacterial genera of either algal case were characterized as heterotrophic nitrifying bacteria. Our results suggest that selection of indigenous bacteria that symbiotically interact with algal species is important for better performance of wastewater treatment.

A Study on the Effective Surge Protection Method from Induced Lightning Surge to Improve Isolate Grounding to Common Grounding (낙뢰 Surge 방호를 위한, 독립접지를 공통접지로 개선하는 효율적인 방법에 대한 연구)

  • Woo, Jea-Wook
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.215-218
    • /
    • 2013
  • This paper proposes the effective method to improve the protection from induced lightning surge by making common grounding from individual grounding. Common grounding under equipotential principle is more effective than individual grounding for lightning surge protection, and so common grounding is indicated as international technical standard under the AC power supply system with neutral line. So, this paper is to propose the effective way of induced lightning surge protection method for currently installed power supply system which has no neutral grounded line and individual grounding which are weak for lightning surge protection. This proposal can improve the power supply system as has neutral line, and improve the grounding system to common grounding system. And also this paper proposes to make effective equipotential system with voltage variable shunting devices for lightning surge protection.

  • PDF

Bloom of a Filamentous Green Alga Cladophora vadorum (Areschoug) Kützing and Nutrient Levels at Shangrok Beach, Buan, Korea (부안 상록해수욕장의 사상 녹조류 금발대마디말(Cladophora vadorum) 대량발생과 영양염 농도)

  • Ha, Dong Soo;Yoo, Hyun Il;Chang, Soo Jung;Hwang, Eun Kyoung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.2
    • /
    • pp.241-246
    • /
    • 2016
  • A filamentous green alga Cladophora vadorum (Areschoug) Kützing, bloomed at Shangrok Beach, Buan, Republic of Korea, in September 2015. This alga is currently distributed worldwide. Concentrations of total nitrogen (TN), total phosphorus (TP), dissolved inorganic nitrogen (DIN), and dissolved inorganic phosphorus (DIP) were analyzed in the bloom area and compared to those of other areas in the vicinity. DIN and DIP concentrations were similar to those of other areas. However, TN and TP were as much as six and ten times higher than in other areas, respectively. As in other Cladophora species, the bloom of C. vadorum at Shangrok Beach in 2015 appears to have depended on the TP concentration in the seawater. This suggests that blooms in the area can be controlled by reducing TP.

Effective Total Nitrogen (TN) Removal in Partially Aerated Biological Aerated Filter (BAF) with Dual Size Sand Media (다중 모래 여재를 적용한 부분 포기 Biological Aerated Filter의 효과적인 Total Nitrogen (TN) 제거)

  • Kang, Jeong-Hee;Song, Ji-Hyeon;Ha, Jeong-Hyub
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.5-14
    • /
    • 2010
  • A pilot-scale biological aerated filter (BAF) was operated with an anaerobic, anoxic and oxic zone at $23{\pm}1^{\circ}C$. The influent sCOD and total nitrogen concentrations in the feedwater were approximately 250 mg/L and 35 mg N/L, respectively. sCOD removal at optimum hydraulic retention time (HRT) of 3 hours with recirculation rates of 100, 200 and 300% in the column was more than 96%. Total nitrogen removal was consistently above 80% for 4 and 6 hours HRT at 300% recirculation. For 3 hours HRT and 300% recirculation, total nitrogen removal was approximately 79%. Based on fitting results, the kinetic parameter values on nitrification and denitrification show that as recirculation rates increased, the rate of ammonia and nitrate transformation increased. The ammonium loading rates for maximum ammonium removed were 0.15 and 0.19 kg $NH_3$-N/$m^3$-day for 100% and 200% recirculation, respectively. The experimental results demonstrated that the BAF can be operated at an HRT of 3 hours with 200 - 300% recirculation rates with more than 96 % removal of sCOD and ammonium, and at least 75% removal of total nitrogen.