• Title/Summary/Keyword: TM-S

Search Result 1,205, Processing Time 0.036 seconds

A Retrospective Analysis of MRI-verified 29 Cases of Transverse Myelitis (자기공명촬영으로 확인된 횡단성 척수염 29례에 대한 후향적 분석)

  • Kim, Young-Rae;Song, Jun-Hyeok;Park, Hyang-Kwon;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1642-1649
    • /
    • 2000
  • Objectives : Transverse myelitis(TM) is characterized by bilateral motor, sensory, and autonomic dysfunction of the spinal cord in the absence of pre-existing neurologic disease. It is an uncommon but not rare condition. But it remains as poorly understood syndrome not only etiologically but also in terms of its clinical behavior. Neurosurgically, It is often quite difficult to distinguish from other surgical intramedullary lesions. We present our clinical experiences of TM in order to assess its clinical behavior and to define the radiological characteristics that can distinguish TM from other intramedullary lesions. Methods : From June 1991 to May 1997, twenty-nine patients with transverse myelitis were admitted to our department. All cases revealed acute or subacute syndrome of non-compressive myelopathy and intramedullary lesions in the MRI. We analyze the radiological data and medical records retrospectively. Results : Patients ranged in age from 16 to 66 years, with 22 males and 7 females. Mean follow-up period was 53 months. For the offending levels, cervical was 5, thoracic 21, and lumbar 3 in number. The patients who presented the return of symptoms after a diminution or abatement of initial symptoms were 7(24%). In the MRI, TM showed typical characteristics of high signal intensity lesions in the center of spinal cord in T2 weighted images and low- to iso-signal intensity in T1 weighted images. A focal nodular enhancement pattern was observed in 58.6%(17/29) of the patients. MR follow-up studies were done in the 21 patients and radiological improvement were verified. Biopsies were done in 3 patients. Normal to good outcome was achieved in 62% of the patients. Conclusion : Transverse myelitis has characteristic radiological findings that can be distinguished from other intramedullary lesions. In our series, it is associated with significant recurrence rates thus, should not be considered a selflimiting disease with good prognosis.

  • PDF

Non-invasive Brain Stimulation and its Legal Regulation - Devices using Techniques of TMS and tDCS - (비침습적 뇌자극기술과 법적 규제 - TMS와 tDCS기술을 이용한 기기를 중심으로 -)

  • Choi, Min-Young
    • The Korean Society of Law and Medicine
    • /
    • v.21 no.2
    • /
    • pp.209-244
    • /
    • 2020
  • TMS and tDCS are non-invasive devices that treat the diseases of patients or individual users, and manage or improve their health by applying stimulation to a brain through magnetism and electricity. The effect and safety of these devices have proved to be valid in several diseases, but research in this area is still much going on. Despite increasing cases of their application, legislations directly regulating TMS and tDCS are hard to find. Legal regulation regarding TMS and tDCS in the United States, Germany and Japan reveals that while TMS has been approved as a medical device with a moderate risk, tDCS has not yet earned approval as a medical device. However, the recent FDA guidance, European MDR changes, recalls in the US, and relevant legal provisions of Germany and Japan, as well as recommendations from expert groups all show signs of tDCS growing closer to getting approved as a medical device. Of course, safety and efficacy of tDCS can still be regulated as a general product instead of as a medical device. Considering multiple potential impacts on a human brain, however, the need for independent regulation is urgent. South Korea also lacks legal provisions explicitly regulating TMS and tDCS, but they fall into the category of the grade 3 medical devices according to the notifications of the Korean Ministry of Food and Drug Safety. And safety and efficacy of TMS are to be evaluated in compliance with the US FDA guidance. But no specific guidelines exist for tDCS yet. Given that tDCS devices are used in some hospitals in reality, and also at home by individual buyers, such a regulatory gap must quickly be addressed. In a longer term, legal system needs to be in place capable of independently regulating non-invasive brain stimulating devices.

A COMPARATIVE STUDY ON RADIOPACITY OF ROOT CANAL SEALERS (근관 전색재의 방사선 불투과성에 관한 비교연구)

  • Kim, Tae-Min;Kim, Seo-Kyoung;Hwang, In-Nam;Hwang, Yun-Chan;Kang, Byung-Cheol;Yoon, Suk-Ja;Lee, Jae-Seo;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2009
  • This study was performed to assess the radiopacity of a variety of root canal sealers according to the specification concerning root canal sealers. Ten materials including Tubli-$Seal^{TM}$. Kerr Pulp Canal $Sealer^{TM}$, AH $26^{(R)}$, AH $plus^{(R)}$, AH plus $jet^{TM}$, Ad sea $1^{TM}$. $Sealer^{TM}$, $NOGENOL^{TM}$, ZOB $seal^{TM}$, $Epiphany^{TM}$ and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film was performed at different voltage and exposure time. In the second part, ten specimens were radiographed simultaneously with an aluminum step wedges on the occlusal films under decided condition. The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions, the appropriate voltage and exposure time that meet the requirement density was 60 kVp at 0.2 s 2. All of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards. 3. The radiopacity of materials increased as thickness of materials increased. 4. The mm Al value of each specimen at 1mm in thickness has a significant difference in the statistics. It suggests that root canal sealers have a sufficient radiopacity that meet the requirement.

Drug Target Identification of a natural anticancer agent plumbagin using $GPScreen^{TM}$: An innovative Technology for Drug Target Discovery using Drug-induced haploinsufficiency in S. pombe Genome-wide Heterozygous Deletion Mutant Library ($GPScreen^{TM}$ 이용한 천연 항암물질인 plumbagin의 약물 작용점 연구: 분열 효모인 S. pombe 유전체 이종 결손 변이 라이브러리에서의 약물에 의한 haploinsufficiency를 이용한 약물 작용점 규명을 위한 혁신 기술)

  • Lee, Ju-Hee;Yeon, Ji-Hyun;Yoon, Pyoung-Oh;Roh, Whi-Jae;Park, Han-Oh;Kim, Dong-Myung
    • 한국약용작물학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.106-107
    • /
    • 2011
  • PDF

Long-Term Starvation Induces the Viable-but-Nonculturable Condition in Lactobacillus crispatus KLB46

  • Lee, Seok-Yong;Kim, Ju-Hyeon;Jang, Jeong-Eun;Kim, Seung-Cheol;Yun, Hyeon-Sik;So, Jae-Seong
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.918-922
    • /
    • 2001
  • In a previous study, we have isolated a number of lactobacilli from Korean women, and one of them (KLB46) was identified as Lactobacillus crispatus by 16S rRNA gene sequencing. For the ecological treatment of bacterial vaginosis (BV) cell suspension of L. crispatus KLB46 was instillated into BV patients. L. crispatus KLB46 was found to persist for several days in cell suspension with no nutrients. In this study, in order to assess the influence of starvation on physiological activity, we compared the viability and culturability of KLB46 following suspension in various buffer solutions. A pair of in situ fluorescent dye was used to assess viability (i.e. membrane integrity) and the culturability was examined by plate count assay. A rapid epifluorescence staining method using the LIVE/DEAD Bacterial Viability Kit $(BacLight^{TM})$ was applied to estimate both viable and total counts of bacteria in cell suspension. $BacLight^{TM}$ is composed of two nucleic acid-binding stains ($SYTO\;9^{TM}$ and propidium iodide). $SYTO\;9^{TM}$ penetrates all bacterial membranes and stains the cells green while propidium iodide only penetrates cells with damaged membranes, therefore the combination of the two stains produces red fluorescing cells. Optimal staining conditions for $BacLight^{TM}$ were found to be with 0.0835M $SYTO\;9^{TM}$ and 0.05M propidium iodide for 15 min incubation at room temperature in dark. When cells were microscopically examined during 140 hours of starvation, the culturability decreased markedly while the viability remained relatively constant, which suggests that large fraction of KLB46 cells became viable but non-culturable (VBNC) upon starvation.

  • PDF

Aeromagnetic Pre-processing Software Based on Graphic User Interface, KMagLevellingTM (그래픽 사용자 인터페이스 기반 항공자력탐사 전처리 S/W, KMagLevellingTM)

  • Ko, Kwang-Beom;Jung, Sang-Won
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.3
    • /
    • pp.171-178
    • /
    • 2014
  • Aeromagnetic survey generally require much more pre-processing steps than that of common land survey due to several complex and cumbersome steps included in pre-processing stage. Therefore it is desirable to use specific processing tool especially based on graphic user interface. For this purpose, aeromagnetic pre-processing software based on graphic user interface under the Windows environment, called $KMagLevelling^{TM}$ was developed and briefly introduced. In an aspect of its user-friendliness and originality, three noticeable features of $KMagLevelling^{TM}$ are summarized as the following (1) function of representation and handling for large amount of aeromagnetic data set as a visualization in the form of flight-path (2) function of selective exclusion of unwanted data by using survey area information expressed as polygon, and (3) function of selective removal processing for the irregular flight-path data acquired within the entire survey area by implementing the segmentation of flight-path technique.

Effect of aging on tear strength and cytotoxicity of soft denture lining materials; in vitro

  • Landayan, Jordi Izzard Andaya;Manaloto, Adrian Carlos Francisco;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.115-120
    • /
    • 2014
  • PURPOSE. The aim of this in vitro study was to evaluate the effect of aging on the tear strength and cytotoxicity of four soft denture lining materials. MATERIALS AND METHODS. Four commonly used soft denture lining materials, (Coe-Comfort$^{TM}$ GC America Inc., Alsip, IL, USA; Coe-SOFT$^{TM}$ GC America Inc., Alsip, IL, USA; Visco-gel Dentsply Caulk Milford, DE, USA; and Sofreliner Tough M Tokuyama Dental Corporation Tokyo, Japan) were selected. Sixty trouser-leg designed specimens per lining material were fabricated using a stainless steel mold for tear strength testing. The specimens were divided into non-thermocycling and 1000-, and 3000-thermocycling groups. For the cytotoxicity test, twenty-four disk shaped specimens per material were fabricated using a stainless steel mold. The specimens were soaked in normal saline solution for 24 h, 48 h and 72 h. Cytotoxicity was measured by XTT assay in L929 mouse fibroblasts. Data were analyzed by two way analysis of variance and Dunnett's test (P<.05). RESULTS. Before thermocycling, Sofreliner Tough M ($10.36{\pm}1.00N$) had the highest tear strength value while Coe-Comfort$^{TM}$ ($0.46{\pm}0.10N$) had the lowest. After 3000 cycles, Sofreliner Tough M ($9.65{\pm}1.66N$) presented the highest value and Coe-Comfort$^{TM}$ ($0.42{\pm}0.08N$) the lowest. Sofreliner Tough M, in all incubation periods was the least toxic with significant differences compared to all other materials (P<.05). Coe-Comfort$^{TM}$, Coe-$SOFT^{TM}$, and Sofreliner Tough M did not show any significant differences within their material group for all incubation periods. CONCLUSION. This in vitro study revealed that aging can affect both the tear strength and cytotoxicity of soft denture materials depending on the composition.

Derivation and Comparison of Narrow and Broadband Algorithms for the Retrieval of Ocean Color Information from Multi-Spectral Camera on Kompsat-2 Satellite

  • Ahn, Yu-Hwan;Shanmugam, Palanisamy;Ryu, Joo-Hyung;Moon, Jeong-Eom
    • Korean Journal of Remote Sensing
    • /
    • v.21 no.3
    • /
    • pp.173-188
    • /
    • 2005
  • The present study aims to derive and compare narrow and broad bandwidths of ocean color sensor’s algorithms for the study of monitoring highly dynamic coastal oceanic environmental parameters using high-resolution imagery acquired from Multi-spectral Camera (MSC) on KOMPSAT-2. These algorithms are derived based on a large data set of remote sensing reflectances ($R_{rs}$) generated by using numerical model that relates $b_b/(a + b_b)$ to $R_{rs}$ as functions of inherent optical properties, such as absorption and backscattering coefficients of six water components including water, phytoplankton (chl), dissolved organic matter (DOM), suspended sediment (SS) concentration, heterotropic organism (he) and an unknown component, possibly represented by bubbles or other particulates unrelated to the first five components. The modeled $R_{rs}$ spectra appear to be consistent with in-situ spectra collected from Korean waters. As Kompsat-2 MSC has similar spectral characteristics with Landsat-5 Thematic Mapper (TM), the model generated $R_{rs}$ values at 2 ㎚ interval are converted to the equivalent remote sensing reflectances at MSC and TM bands. The empirical relationships between the spectral ratios of modeled $R_{rs}$ and chlorophyll concentrations are established in order to derive algorithms for both TM and MSC. Similarly, algorithms are obtained by relating a single band reflectance (band 2) to the suspended sediment concentrations. These algorithms derived by taking into account the narrow and broad spectral bandwidths are compared and assessed. Findings suggest that there was less difference between the broad and narrow band relationships, and the determination coefficient $(r^2)$ for log-transformed data [ N = 500] was interestingly found to be $(r^2)$ = 0.90 for both TM and MSC. Similarly, the determination coefficient for log-transformed data [ N = 500] was 0.93 and 0.92 for TM and MSC respectively. The algorithms presented here are expected to make significant contribution to the enhanced understanding of coastal oceanic environmental parameters using Multi-spectral Camera.

Development of 3MW Wind Turbine for IEC Wind Class IIa (3MW급 IEC Wind Class IIa 풍력발전시스템 개발)

  • Lee, K.H.;Lee, S.I.;Woo, S.W.;Oh, I.G.;Park, J.P.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.236-239
    • /
    • 2011
  • This paper introduces the design concepts and characteristics of WinDS3000$^{TM}$(TC IIa) which is a trade name of Doosan's 3MW offshore/onshore wind turbine. WinDS3000$^{TM}$(TC IIa) has been designed in consideration of high Reliability, Availability, Maintainability and Serviceability (RAMS) and low cost of electricity (CDE) for the TC IIa condition based on GL guideline. An integrated drive-train design with an innovative three-stage gearbox has been introduced to minimize nacelle weight of the wind turbine and to enhance a high reliability for transmission. A permanent magnet generator with full converter system has been introduced to get higher efficiency in partial load operation and grid-friendly system for both 50 Hz and 60 Hz. A pitch-regulated variable speed control system has been introduced to control wind turbine power while generator reaction torque can be adjusted almost instantaneously by the associated power electronics. The wind turbine has been also equipped with condition monitoring and diagnostic systems in order to meet maintainability requirements.

  • PDF

A Study for Magnetic Orientation Enhancement in Nd-Fe-B Sintered Magnets (Nd-Fe-B계 소결자석의 이방화율 향상을 위한 연구)

  • 김동환;임광윤;김효준;조재완;서응석;김승호;김상면
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.1
    • /
    • pp.8-13
    • /
    • 2001
  • Effects of casting Processes and lubricant addition were studied to improve remanence of 31RE-68TM-lB based sintered magnet by using axial pressing process. Strip casting was effective to get the fine and homogeneous microstructure without ${\alpha}$-Fe segregation. The strip cast flake resulted in narrower particle size distribution after jet milling with respect to the conventional cast ingot. During pressing step with a magnetic field, the particle alignment was increased by appropriate addition of liquid lubricant. In this study, it was revealed that narrow particle size distribution and appropriate addition of liquid lubricant were essential to improve the grain alignment and thus the remanence of Nd-Fe-B sintered magnet.

  • PDF