Development of a prototype TL/OSL reader for on-site use in a large-scale radiological accident

  • Hyoungtaek Kim;Chang-Young Park;Sang In Kim;Min Chae Kim;Jungil Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2113-2119
    • /
    • 2024
  • This study presents the development and characterization of a prototype TL/OSL reader for the retrospective dose assessment of individuals in radiological emergencies. The reader is portable, semi-automatic, and capable of accurate measurements. The dimension of the reader is 25 × 25 × 37 cm3 and the weight is about 15 kg. The reader consists of a sample moving stage, a heating module, an optical stimulation module, a detection module, a data acquisition (DAQ) unit, a nitrogen gas control module, and a PC with a GUI program. The reader has three measurement modes: TL, CW_OSL, and custom mode. The reader was characterized using commercial thermal luminescence dosimeters (TLD, LiF:Mg,Cu,Si) and optically stimulated dosimeters (OSLD, Al2O3:C), as well as fortuitous materials, such as display glasses and resistors of mobile phone. The results showed that the reader is capable of measuring signals with a detection limit of up to 0.02 mGy using a commercial dosimeter. In the dose recovery test using fortuitous materials, the reconstructed doses obtained three days post-irradiation closely aligned with the initially administered doses. As a result, this study suggests that the developed TL/OSL reader is a promising instrument for emergency dose assessment at accident sites.

열자극발광 및 광자극발광 측정장치의 개발 (Development of Thermoluminescence and Optical Stimulated Luminescence Measurements System)

  • 박창영;정기수;이종덕;장인수;이정일;김장렬
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.46-54
    • /
    • 2015
  • 열이나 빛의 자극에 의한 물질의 발광현상, 즉 열자극발광(thermoluminescence, TL)과 광자극발광(optically stimulated luminescence, OSL)의 메커니즘을 규명하고, 이 현상을 방사선량의 측정에 활용할 수 있는 새로운 발광물질을 개발하는데 활용할 수 있는 측정장치를 개발하였다. 이는 열자극과 광자극을 동시에 가할 수 있는 장치로서, 열자극에 필요한 온도제어를 위하여 35 kHz의 정현파 전원으로 변환하여 스트립 형태의 발열부에 걸어주게 되며, 최대 $20K{\cdot}s^{-1}$의 온도상승률로 약 1K의 정밀도로 온도를 제어할 수 있었다. 광자극을 위한 광원으로 중심파장이 470 nm인 Luxeon V형 고휘도 LED 등 여러 파장영역의 LED나 레이저를 사용할 수 있도록 하였다. 대표적으로 470 nm의 LED로 $Al_2O_3$:C의 OSL을 측정하는 경우, 시료의 발광에서 자극광을 분리시키기 위하여 LED의 자극광은 단파장차단필터인 GG420을 통과시켜서 시료에 걸리게 하고, 시료의 발광은 대역통과필터인 UG11를 통과하여 광증배관에 걸리게 하였다. 아울러 시료에 따라 LED나 필터들을 다르게 조합할 수 있도록 하여 시료의 발광특성에 맞는 최적의 측정을 수행할 수 있다. PC로 측정장치의 전체적인 제어가 이루어지며 LabView로 개발한 제어프로그램은 그래픽사용자환경(GUI)으로 되어 있다. 이 연구를 통해서 개발한 장치로 LiF:Mg,Cu,Si와 $Al_2O_3$:C를 표준시료로 하여 TL과 OSL을 측정하였고, 이들의 발광특성이 기존에 알려진 특성을 재현하여 이 장치가 신뢰할 수 있는 성능을 내는 것을 확인할 수 있었다.

Thermoluminescent Characteristics of Newly Developed LiF:Mg,Cu,Na,Si TL Detectors

  • Lee J. I.;Kim J. L.;Chang S. Y.
    • Nuclear Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.47-52
    • /
    • 2004
  • Recently, a new sintered pellet-type LiF:Mg,Cu,Na,Si TL detector which has a high sensitivity and good reusability, named KLT-300(KAERI LiF:Mg,Cu,Na,Si TL detector), was developed by the variation of the dopants concentrations and the parameters of the preparation procedure at KAERI (Korea Atomic Energy Research Institute). In this study, the thermoluminescent characteristics of the newly developed TL detectors were investigated. The sensitivity of the TL detector was compared with that of the TLD-100 by light integration. The dose linearity of the detector was tested from $10^{-6}$ Gy up to 30 Gy. The dose response was very linear up to 10 Gy and a sublinear response was observed at higher doses. The energy response of the detector was studied for photon energies from 20 keV to 662 keV. The result shows that a maximum response of 1.004 at 53 keV and a minimum response of 0.825 at 20 keV were observed. The reproducibility study for the TL detector was also carried out. The coefficients of variation for each detector separately did not exceed 0.016, and for all the 10 detectors collectively was 0.0054. Lower limit of detection for the detector was investigated at 70 nGy by the Harshaw 4500 TLD Reader and the residual signal of the TL detector was found to be $0.57\%$.

LiF:Mg,Cu,Na,Si TL 소자의 선량계적 특성 (Dosimetric Properties of LiF:Mg,Cu,Na,Si TL pellets)

  • 남영미;김장렬;장시영
    • Journal of Radiation Protection and Research
    • /
    • 제26권1호
    • /
    • pp.7-12
    • /
    • 2001
  • 최근 개발된 방사선량 측정용 LiF:Mg,Cu,Na,Si TL 소자의 글로우 곡선, 방출스펙트럼, 광자에 대한 선량의존성, 에너지의존성 및 페이팅 등과 같은 물리적 및 선량계적 특성들을 연구하였다. LiF:Mg,Cu,Na,Si TL 소자는 LiF:Mg,Cu,Na,Si TL 분말에 압력을 가한 후 소결하는 방법으로 제조되었다. 방사선에 대한 특성을 알아보기 위하여 광자선 조사는 한국원자력연구소의 X선 발생 장치 및 $^{137}Cs$ ${\gamma}$선 원격조사장치를 이용하였으며, 사용된 광자선 에너지 범위는 20-662keV, 선량 범위는 $10^{-6}-10^{-2}\;Gy$이었다. 글로우 곡선은 수동형의 TLD 판독장치 (System 310, Teledyne)로 질소를 흘리면서 선형적인 가열률로 측정하였으며, TL 강도는 글로우 곡선을 전체 적분한 면적으로 평가하였다. $5^{\circ}C\;s^{-1}$의 선형적인 가열률로 측정한 글로우 곡선은 5개의 피크들로 분리되었으며, $234^{\circ}C$에 나타나는 주피크의 활성화에너지는 2.34 eV, 진동수인자는 $1.00{\times}10^{23}$이고, 방출스펙트럼은 410nm를 중심으로한 단일한 분포로 나타났다. 선량의존성은 100Gy 이상까지 선형성을 나타내었으며, $^{137}Cs$에 대한 저에너지 광자의 상대적인 에너지 반응값은 20% 범위 이내였다. 또한 실온에서 1년간 보관하였을 때, 시간경과에 따른 TL 감도의 감소가 거의 없는 좋은 페이딩 특성을 보였다.

  • PDF

Measuring Thermo-luminescence Efficiency of TLD-2000 Detectors to Different Energy Photons

  • Xie, Wei-min;Chen, Bao-wei;Han, Yi;Yang, Zhong-Jian
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.179-183
    • /
    • 2016
  • Background: As an important detecting device, TLD is a widely used in the radiation monitoring. It is essential for us to study the property of detecting element. The aim of this study is to calculate the thermo-luminescence efficiency of TL elements. Materials and Methods: A batch of thermo-luminescence elements were irradiated by the filtered X-ray beams of average energies in the range 40-200 kVp, 662 keV $^{137}Cs$ gamma rays and then the amounts of lights were measured by the TL reader. The deposition energies in elements were calculated by theory formula and Monte Carlo simulation. The unit absorbed dose in elements by photons with different energies corresponding to the amounts of lights was calculated, which is called the thermo luminescent efficiency (${\eta}^{(E)}$). Because of the amounts of lights can be calculated by the absorbed dose in elements multiply ${\eta}^{(E)}$, the ${\eta}^{(E)}$ can be calculated by the experimental data (the amounts of lights) divided by absorbed dose. Results and Discussion: The deviation of simulation results compared with theoretical calculation results were less than 5%, so the absorbed dose in elements was calculated by simulation results in here. The change range of ${\eta}^{(E)}$ value, relative to 662 keV $^{137}Cs$ gamma rays, is about 30% in the energy range of 33 keV to 662 keV, is in accordance by the comparison with relevant foreign literatures. Conclusion: The ${\eta}^{(E)}$ values can be used for updating the amounts of lights that are got by the direct ratio assumed relations with deposition energy in TL elements, which can largely reduce the error of calculation results of the amounts of lights. These data can be used for the design of individual dosimeter which used TLD-2000 thermo-luminescence elements, also have a certain reference value for manufacturer to improve the energy-response performance of TL elements by formulation adjustment.

선량 판독용 OSL 측정장치의 개발 (Development of OSL Dosimetry Reader)

  • 박창영;정기수;이종덕;장인수;이정일;김장렬
    • Journal of Radiation Protection and Research
    • /
    • 제37권1호
    • /
    • pp.10-15
    • /
    • 2012
  • 개인 선량계로 활용될 수 있는 광자극발광(OSL: optically stimulated luminescence) 측정장치의 개발과 이를 위한 이론적 배경 및 개발된 장치의 성능에 대하여 기술하였다. OSL 측정장치는 자극광원과 시료로부터 자극 발광된 광신호 사이의 간섭효과를 최소화하기 위하여 다양한 광학적 필터 조합을 구성해야 하는데, 여기서는 자극광에는 GG420 필터를, 측정부에는 UG11과 BG39 필터로 $Al_2O_3:C$ OSL 물질에 최적화된 광학적 필터를 구성하였다. 자극광원으로 Luxeon V형 고휘도 Blue LED를 선택함으로서 충분한 광량을 확보하였다. 또한 장비 제어 및 측정을 위하여 PC와 OSL 장치 사이에 다양한 제어보드들이 이용되며, 전체 장치의 자동화 및 장치제어는 LabView 프로그램을 이용하여 개발하였다. 개발된 OSL 장치의 신뢰도 및 재현성 평가를 위해 대표적인 OSL 물질인 $Al_2O_3:C$를 이용하여 OSL 특성곡선을 측정하고 이를 기존 상용 OSL 측정장치와 비교하였다.

LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 특성 (Anneal Characteristics of LiF:Mg,Cu,Na,Si Teflon TLDs)

  • 남영미;정운혁;이대원;김현자;김기동
    • Journal of Radiation Protection and Research
    • /
    • 제22권3호
    • /
    • pp.135-141
    • /
    • 1997
  • 열처리 특성의 연구는 열형광선량계를 재 사용하는데 있어서 중요하다. 최근 개발된 디스크 형태 (직경 4.5 mm, 두께 약 $90mg/cm^2$)의 LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 조건을 구하기 위하여 조사전열처리, 판독과정 및 판독 후 열처리의 순서로 연구하였다. Teflon TLD의 감마선 조사는 $^{60}Co$ 0.1 Gy로 하였다. LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 특성의 연구는 전기로와 판독장치를 이용하여 열처리 온도와 열처리 시간을 변화시키면서, 측정반복횟수에 따른 열형광강도 변화를 관찰하는 방법으로 수행하였다. LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 조건은 조사전 열처리를 $80^{\circ}C$에서 1 시간 한 후 $280^{\circ}C$까지 판독하고 판독 후 열처리를 $270^{\circ}C$에서 20 초간 하는 것으로 결정되었고, 이 조건에서 10 회 반복측정시 원래의 열형광강도는 5%의 감소를 보였다.

  • PDF

LiF:Mg,Cu,P 열형광선량계의 선량특성을 이용한 눈가림법에 의한 출력선량 평가 (Evaluation the Output Dose of Linear Accelerator Photon Beams by Blind Test with Dose Characteristics of LiF:Mg,Cu,P TLD)

  • 최태진;이호준;예지원;오영기;김진희;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.308-316
    • /
    • 2009
  • 조사면의 크기와 한계 측정부위의 선량평가에는 형체가 자유로운 열형광분말체를 이용하는 것이 적합함을 뒷받침하기 위하여 LiF:Mg,Cu,P TLD 분말체의 선량특성을 조사하고, 작성된 평가 알고리즘에 따라 선형가속기의 출력선량을 눈가림법으로 조사한 TLD에 적용했을 때 평가 신뢰성을 확인하고자 한다. 열형광분말소자는 PTW 사의 LiF:Mg,Cu,P (200 Mesh)이며, 판독기는 LTM (LTM Co, France)이다. 물의 흡수선량은 전리함과 전위계를 표준선량평가기관에서 교정한 흡수선량계수를 사용하여 구하였으며, TLD 조사는 자체 제작한 미니 프라스틱 수조의 중앙에 삽입하여 조사면 $10{\times}10\;cm^2$로 시행 하였다. 방사선조사는 두 대학병원에 설치된 선형가속기(Oncor, Siemens와 Clinac Ix, Varian)의 6 MV 광자선으로 하였으며, TLD의 눈가림법 선량평가는 glow 곡선의 특성과 분말질량에 의한 감도변화, 선량률의존성, 선량-TL 강도의 비례성과 퇴행성 조사를 통해 시행되었다. LiF:Mg,Cu,P TLD는 3개의 glow peak를 보였고 232도에 나타나는 peak는 선량과 비례성이 높고 감도가 높으며 퇴행현상이 적어 선량계로써 좋은 조건을 보이고 있다. 열형광선량분말체는 1,000 cGy까지 대략적인 선형관계를 유지하였으나, 정밀 측정평가를 위해 비선형 함수를 통해 평균 1% 오차범위에서 평가할 수 있었다. LiF:Mg,Cu,P TLD는 선량률 22.2 cGy/min에서 600 cGy/min까지 TL 감도에 거의 영향을 주지 않았으나, 가열판(Planchette)의 분말체의 량에 따라서는 TL 감도에 변화가 있음을 확인하였다. 눈가림법으로 두 기관의 선형가속기에서 15회와 10회 조사하였고, 선량범위는 15~800 cGy였다. 눈가림법에 의한 양 기관의 TL 선량은 평균 1% 이하의 오차범위에서 일치하고 편차는 각각 ${\pm}1.9%$${\pm}2.58$ 이내에 있었다. 열형광분말소자를 사용하여 눈가림법으로 출력선량을 평가한 결과 실험오차범위에서 표준전리함의 선량과 잘 일치하였으며, 전리함으로 접근할 수 없는 작은 조사면이나 경계성 조사면에 대한 선량평가에 신뢰성 있는 평가를 할 수 있을 것으로 생각한다.

  • PDF

Metamaterial 발룬으로 급전된 Capacitively Loaded 루프 안테나 (Capacitively Loaded Loop Antenna Fed with Metamaterial Balun)

  • 정윤권;이범선
    • 한국전자파학회논문지
    • /
    • 제20권10호
    • /
    • pp.1084-1090
    • /
    • 2009
  • 본 논문에서는 T-junction을 통해 분배된 두 선로를 한 쪽은 N개의 단일 셀을 사용한 우/좌형 전송선, 다른 한 쪽은 우형 전송선을 이용한 발룬을 설계하였다. 이에 있어 closed-form solutions과 그 해를 바탕으로 설계된 CPW 전송선을 이용한 초소형 광대역 발룬(80 %)을 제시한다. 또한 균일한 전류 분포를 위해 칩 커패시터를 장하시킨 안테나를 제안한다. 본 안테나는 $\lambda/4$ 이하의 간격을 두고 장하되었을 때 직렬 공진 현상을 보이며 안테나 입력 저항은 약 $204\;\Omega$이다. 제안된 루프 안테나의 단일 셀은 좀 더 균일한 전류 분포를 위해 약 $\lambda/12$의 간격을 두고 제작되었으며(전체 길이: $1\;\lambda$), 동일한 길이의 단일 권선 구조를 갖는 기존 루프 안테나에 비해 20 dB가 더 큰 자계를 형성함을 EM 시뮬레이션과 측정을 통해 알 수 있었다. 이 안테나와 제시된 발룬 사이에는 CPS(Coplanar Strip Line)구조가 사용된다. 본 안테나는 근거리장 UHF 대역 RFID 리더 안테나에 응용될 수 있다.

확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구 (A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response)

  • 조대형;오장진;한승재;나성호;황원국;이원근
    • Journal of Radiation Protection and Research
    • /
    • 제23권3호
    • /
    • pp.123-138
    • /
    • 1998
  • 개인피폭선량 평가용 열형광선량계인 UD802 선량재에 대한 X-선장, 감마선장, 베타선장 및 중성자선장의 순수선장과 X-선장/감마선장, 베타선장/감마선장 및 중성자장/감마선장의 혼합선장에서의 반응특성을 조사하였으며 소자반응이 확률적으로 분포하는 성질을 이용한 개인피폭선량 평가 방법을 개발하였다. 선량계 특성조사를 위한 기준조사는 한국원자력안전기술원의 X-선장, 베타선장 및 감마선장을 이용하였으며 중성자선장은 미국 PNL에 의뢰하여 수행하였다. 특성조사 결과 광자 선장에 대한 소자1과 소자2는 에너지에 대한 의존성이 매우 적어 선량당량의 계산시 매우 유용한 자료로 사용되어질 수 있으며 소자3과 소자4는 저에너지 및 중에너지의 광자선장에 대해 매우 민감한 변화를 보이고 있다. 소자1/소자3 및 소자1/소자4의 반응비는 베타선장과 중성자선장에 대하여 에너지의존성이 큰 반응비를 나타내며, 소자3/소자2의 반응비는 중성자선장에 대해서만 1이하의 값을 나타내고 있다. 저에너지 및 중에너지 광자선장에 대한 에너지 분별은 소자3/소자2 및 소자3/소자4의 반응비로서 가능함을 확인하였다. 본 연구에서 개발한 확률분포 분석법의 적용가능성을 보이기 위하여 Panasonic UD716AGL/UD802 판독시스템에 적용하여 ANSI N13.11-1993에 따른 성능검증을 수행하였다. 성능검증 결과 모든 범주에 대하여 성능지수, ${\mid}B{\mid}+S$가 최대 0.232의 성능이 확인되었다. 특히 일부 소자의 비정상적 반응에 대해서도 최적의 피폭선량평가를 수행하고 있음이 확인되었으며, 실험실에서 재현될 수 없는 실제 방사선작업 환경에서의 선량평가 수행시, 본 논문에서 제시한 선량평가방법을 적용할 경우 계획된 피폭과 예상하지 못한 방사선장에 대한 피폭을 구분할 수 있어 보다 심도 있는 피폭선량평가 및 방사선관리가 가능할 것으로 판단된다.

  • PDF