• Title/Summary/Keyword: TID

Search Result 109, Processing Time 0.027 seconds

An Energy Efficient Clustering Algorithm in Mobile Adhoc Network Using Ticket Id Based Clustering Manager

  • Venkatasubramanian, S.;Suhasini, A.;Vennila, C.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.7
    • /
    • pp.341-349
    • /
    • 2021
  • Many emerging mobile ad-hoc network application communications are group-oriented. Multicast supports group-oriented applications efficiently, particularly in a mobile environment that has a limited bandwidth and limited power. Energy effectiveness along with safety are 2 key problem in MANET design. Within this paper, MANET is presented with a stable, energy-efficient clustering technique. In this proposed work advanced clustering in the networks with ticket ID cluster manager (TID-CMGR) has formed in MANET. The proposed routing scheme makes secure networking the shortest route possible. In this article, we propose a Cluster manager approach based on TICKET-ID to address energy consumption issues and reduce CH workload. TID-CMGR includes two mechanism including ticket ID controller, ticketing pool, route planning and other components. The CA (cluster agent) shall control and supervise the functions of nodes and inform to TID-CMGR. The CH conducts and transfers packets to the network nodes. As the CH energy level is depleted, CA elects the corresponding node with elevated energy values, and all new and old operations are simultaneously stored by CA at this time. A simulation trial for 20 to 100 nodes was performed to show the proposed scheme performance. The suggested approach is used to do experimental work using the NS- simulator. TIDCMGR is compared with TID BRM and PSO to calculate the utility of the work proposed. The assessment shows that the proposed TICKET-ID scheme achieves 90 percent more than other current systems.

Using machine learning for anomaly detection on a system-on-chip under gamma radiation

  • Eduardo Weber Wachter ;Server Kasap ;Sefki Kolozali ;Xiaojun Zhai ;Shoaib Ehsan;Klaus D. McDonald-Maier
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.3985-3995
    • /
    • 2022
  • The emergence of new nanoscale technologies has imposed significant challenges to designing reliable electronic systems in radiation environments. A few types of radiation like Total Ionizing Dose (TID) can cause permanent damages on such nanoscale electronic devices, and current state-of-the-art technologies to tackle TID make use of expensive radiation-hardened devices. This paper focuses on a novel and different approach: using machine learning algorithms on consumer electronic level Field Programmable Gate Arrays (FPGAs) to tackle TID effects and monitor them to replace before they stop working. This condition has a research challenge to anticipate when the board results in a total failure due to TID effects. We observed internal measurements of FPGA boards under gamma radiation and used three different anomaly detection machine learning (ML) algorithms to detect anomalies in the sensor measurements in a gamma-radiated environment. The statistical results show a highly significant relationship between the gamma radiation exposure levels and the board measurements. Moreover, our anomaly detection results have shown that a One-Class SVM with Radial Basis Function Kernel has an average recall score of 0.95. Also, all anomalies can be detected before the boards are entirely inoperative, i.e. voltages drop to zero and confirmed with a sanity check.

TID providing method for IEEE 802.l1e MAC protocol in NCTUns simulator (NCTUns 시뮬레이터에서 IEEE 802.11e MAC 프로토콜을 위한 TID 제공방안)

  • 김영환;허필영;석정봉
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.212-215
    • /
    • 2003
  • 본 논문에서는 IEEE 802.11e MAC (Medium Access Control) 프로토콜을 NS-2 등과 같은 유명한 시뮬레이터들보다도 진보적인 NCTUns 시뮬레이터를 이용하여 개발하고자 하면서, 각 MSDU (MAC Service Data Unit)마다 제공되어야 하는 TID (Traffic Identification) 를 결정하는 방안을 모색하고 있다. 따라서 본론에서는 IEEE 802.l1e MAC 프로토콜과 NCTUns 시뮬레이터 에 대해서 기술하며 본 논문에서 제안하는 방법에 대해서 서술한다.

  • PDF

Corrective Control of Asynchronous Sequential Circuits with Faults from Total Ionizing Dose Effects in Space (총이온화선량에 의한 고장이 존재하는 비동기 순차 회로의 교정 제어)

  • Yang, Jung-Min;Kwak, Seong-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.11
    • /
    • pp.1125-1131
    • /
    • 2011
  • This paper presents a control theoretic approach to realizing fault tolerance in asynchronous sequential circuits. The considered asynchronous circuit is assumed to work in space environment and is subject to faults caused by total ionizing dose (TID) effects. In our setting, TID effects cause permanent changes in state transition characteristics of the asynchronous circuit. Under a certain condition of reachability redundancy, it is possible to design a corrective controller so that the closed-loop system can maintain the normal behavior despite occurrences of TID faults. As a case study, the proposed control scheme is applied to an asynchronous arbiter implemented in FPGA.

Ileal Amino Acid Digestibility in Different Cultivars of Chinese Rapeseed Meals for Growing-finishing Pigs

  • Pengbin, Xi;Li, Defa;Gong, Liming
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.9
    • /
    • pp.1326-1333
    • /
    • 2002
  • Studies were conducted with nine barrows, average initial body weight $44.5{\pm}2.1kg$, fitted with a T-cannula at the distal ileum, to determine the apparent ileal (and true) digestibility (AID and TID) of CP and AA in different cultivars of rapeseed meals and soybean meal. The barrows were fed either a casein diet or one of eight corn starch-based semipurified diets, formulated to contain 17.0% CP (DM basis) with one of seven different cultivars of rapeseed meal or soybean meal as the sole source of dietary protein, according to a six-period, nine-treatment, incomplete Latin Square. Chromic oxide (0.5%) was used as a digestibility marker. The pigs were fed of 4% of body weight twice daily, at 08:00 and 20:00 h. Ileal digesta were collected at 2 h intervals daily from 5 d to 7 d. The AID or TID values of CP and most AA (Cysteine excluded) were significantly lower in the rapeseed meals than in soybean meal (p<0.05). There were significant differences in the AID or TID values of CP and AA among the seven different cultivars rapeseed meals (p<0.05); the seven rapeseed meals were arranged according to the size of the AA digestibility values of the rapeseed meals from the greatest to the least, as Zayou 59, Youyan 7, Ganyou 16, Qingyou 2, Huaza 3, Ningza 1 and Lianglou 586; differences in CP, AA, NDF and ADF contents in the rapeseed meals were mainly responsible for the variation in the AID or TID values of AA among rapeseed meals. The AID value of CP can be used as an index of the AID or TID values of most AA in rapeseed meals. However, the AID value of CP was less appropriate as a direct indicator of the AID or TID values for cysteine, methionine, tryptophan, phenylalanine and proline.

Development and Application of 3-Dimensional Shielding Analysis Program to Analyze Total Ionizing Dose Level depending on the Satellite Structure Model (위성구조모델에 따른 방사선 총 이온화 조사량 예측을 위한 3차원 차폐두께 분석 프로그램의 개발 및 응용)

  • Cho, Young-Jun;Lee, Chang-Ho;Lee, Choon-Woo;Hwang, Do-Soon
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.68-75
    • /
    • 2008
  • Space radiation environments depend on satellite mission orbit, period, and date, and it can be predicted by simulation. Total Ionizing Dose(TID) can be predicted by Dose-depth Curve which only inform the dose level depending on the shielding thickness. So detail effective shielding analysis considering real structure is necessary to predict part level TID. For this purpose, program is developed to calculate shielding thickness distribution by structure modeling and ray trace from certain point in the structure. Finally TID at certain point in the 3-dimensional structure can be calculated by integration of shielding distribution result and dose-depth curve data. Using this program, TID is analyzed at part level certain point by modeling of equipment box structure in the satellite.

  • PDF

KEY IMPACT PARAMETERS FOR APPLICATION OF ALTERNATIVE SOURCE TERM TO KORI UNIT 1

  • Lee, Seung-Chan
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.394-413
    • /
    • 2010
  • The object of this paper is to identify the key elements that impact a radiation dose at EAB (Exclusion Area Boundary). This study is based on the AST (Alternative Source Terms) as defined in Regulatory Guide 1.183. The LOCA (Loss of Coolant Accident) and the LRA (Locked Rotor Accident) are selected as limiting cases. A sensitivity analysis of accidental behavior with respect to various parameters during LOCA and LRA at Kori Unit 1 is also undertaken for the following objectives: to determine the limiting parameters, to find the impact trend of the radiation dose, and to find the safety margin between AST and TID (Technical Information Document) methodologies. This work confirms that key parameters are particulate removal rate, decontamination factor, iodine chemical form, gap fraction, partitioning factor, and the impact of isotopes group. Comparing TID with AST, the radiation dose of TID is about 80% greater than that of AST under a LOCA, and about 60% greater than that of AST for the case of a LRA; thus the safety margin is remarkably increased when the AST is used. In this work, the sensitivity analysis results are presented in terms of a sensitivity index called the "NDD (Normalized Dose Difference)", which compares the impact of parameters with that of a reference case. These values are derived by using a combination of the leak rate (primary to secondary), iodine chemical form, gap fraction, partitioning factor, spray removal rate, source term, and other variables.

Towards defining a simplified procedure for COTS system-on-chip TID testing

  • Di Mascio, Stefano;Menicucci, Alessandra;Furano, Gianluca;Szewczyk, Tomasz;Campajola, Luigi;Di Capua, Francesco;Lucaroni, Andrea;Ottavi, Marco
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1298-1305
    • /
    • 2018
  • The use of System-on-Chip (SoC) solutions in the design of on-board data handling systems is an important step towards further miniaturization in space. However, the Total Ionizing Dose (TID) and Single Event Effects (SEE) characterization of these complex devices present new challenges that are either not fully addressed by current testing guidelines or may result in expensive, cumbersome test configurations. In this paper we report the test setups, procedures and results for TID testing of a SoC microcontroller both using standard $^{60}Co$ and low-energy protons beams. This paper specifically points out the differences in the test methodology and in the challenges between TID testing with proton beam and with the conventional gamma ray irradiation. New test setup and procedures are proposed which are capable of emulating typical mission conditions (clock, bias, software, reprogramming, etc.) while keeping the test setup as simple as possible at the same time.

Simulation-based analysis of total ionizing dose effects on low noise amplifier for wireless communications

  • Gandha Satria Adi;Dong-Seok Kim;Inyong Kwon
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.568-574
    • /
    • 2024
  • The development of radiation-tolerant radio-frequency (RF) systems can be a solution for applications in extreme radiation environments, such as nuclear power plant monitoring and space exploration. Among the crucial components within an RF system, the low noise amplifier (LNA) stands out due to its vulnerability to TID effects, mainly relying on transistors as its main devices. In this study, the TID effects in the LNA using standard 0.18 ㎛ complementary metal oxide semiconductors (CMOS) technology are estimated and analyzed. The results show that the LNA can withstand absorbed radiation up to 100 kGy. The S21, S11, noise figure (NF), stability (K), and linearity of the third input intercept point (IIP3) slightly shifted from the initial values of 0.8312 dB, 0.793 dB, 0.00381 dB, 1.34406, and 2.36066 dBm, respectively which are still comparable to the typical performances. Moreover, the standard 0.18 ㎛ technology has demonstrated its radiation tolerance, as it exhibits negligible performance degradation in the conventional LNA even when exposed to radiation levels up to 100 kGy. In this context, simulation approach offers a means to predict the TID effects and estimate the radiation exposure limit for electronic devices, particularly when transistors are used as the primary RF components.

HAUSAT-2 SATELLITE RADIATION ENVIRONMENT ANALYSIS AND SOFTWARE RAMMING CODE EDAC IMPLEMENTATION (HAUSAT-2 위성의 방사능 환경해석 및 소프트웨어 HAMMING CODE EDAC의 구현에 관한 연구)

  • Jung, Ji-Wan;Chang, Young-Keun
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.4
    • /
    • pp.537-558
    • /
    • 2005
  • This paper addresses the results of HAUSAT-2 radiation environment and effect analyses, including TID and SEE analyses. Trapped proton and electron, solar proton, galactic cosmic ray models were considered for HAUSAT-2 TID radiation environment analysis. TID was analyzed through total dose-depth curve and the radiation tolerance of TID for HAUSAT-2 components was verified by using DMBP method and sectoring analysis. HAUSAT-2 LET spectrum for heavy ion and proton were also analyzed for SEE investigation. SEE(SEU, SEL) analyses were accomplished for MPC860T2B microprocessor and K6X8008T2B memory. It was estimated that several SEUs may occur without SEL during the HAUSAT-2 mission life(2 years). Software Hamming Code EDAC has been implemented to detect and correct the SEU. In this study, all radiation analyses were conducted by using SPENVIS software.