• Title/Summary/Keyword: THICKNESS

Search Result 26,229, Processing Time 0.049 seconds

Static strength of collar-plate reinforced tubular T-joints under axial loading

  • Shao, Yong-Bo
    • Steel and Composite Structures
    • /
    • v.21 no.2
    • /
    • pp.323-342
    • /
    • 2016
  • To study the effect of collar-plate reinforcement on the static strength of tubular T-joints under axial loading, fundamental research work is carried out from both experimental test and finite element (FE) simulation. Through experimental tests on 7 collar-plate reinforced and 7 corresponding un-reinforced tubular T-joints under axial loading, the reinforcing efficiency is investigated. Thereafter, the static strengths of the above 14 models are analyzed by using FE method, and it is found that the numerical results agree reasonably well with the experimental data to prove the accuracy of the presented FE model. Additionally, a parametric study is conducted to analyze the effect of some geometrical parameters, i.e., the brace-to-chord diameter ratio ${\beta}$, the chord diameter-to-chord wall thickness ratio $2{\gamma}$, collar-plate thickness to chord wall thickness ratio ${\tau}_c$, and collar-plate length to brace diameter ratio $l_c/d_1$, on the static strength of a tubular T-joint. The parametric study shows that the static strength can be greatly improved by increasing the collar-plate thickness to chord wall thickness ratio ${\tau}_c$ and the collar-plate length to brace diameter ratio $l_c/d_1$. Based on the numerical results, parametric equations are obtained from curving fitting technique to estimate the static strength of a tubular T-joint with collar-plate reinforcement under axial loading, and the accuracy of these equations is also evaluated from error analysis.

A study on the visible wave of transmittance pressable ceramic core (열가압성형도재 코어의 가시광선 투과율에 관한 연구)

  • Jung, In-Ho;Lee, Sang-Deok;Nam, Sang-Yong
    • Journal of Technologic Dentistry
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the transmittance differences of pressable ceramic core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 2 groups (0.6mm, 0.8mm) which have each 3 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown. Also, When making all ceramic core with dead pulp (nervous treatment tooth) when used as a restorative esthetic think is more efficient to improve.

Development of wall-thinning evaluation procedure for nuclear power plant piping - Part 2: Local wall-thinning estimation method

  • Yun, Hun;Moon, Seung-Jae;Oh, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2119-2129
    • /
    • 2020
  • Flow-accelerated corrosion (FAC), liquid droplet impingement erosion (LDIE), cavitation and flashing can cause continuous wall-thinning in nuclear secondary pipes. In order to prevent pipe rupture events resulting from the wall-thinning, most NPPs (nuclear power plants) implement their management programs, which include periodic thickness inspection using UT (ultrasonic test). Meanwhile, it is well known in field experiences that the thickness measurement errors (or deviations) are often comparable with the amount of thickness reduction. Because of these errors, it is difficult to estimate wall-thinning exactly whether the significant thinning has occurred in the inspected components or not. In the previous study, the authors presented an approximate estimation procedure as the first step for thickness measurement deviations at each inspected component and the statistical & quantitative characteristics of the measurement deviations using plant experience data. In this study, statistical significance was quantified for the current methods used for wall-thinning determination. Also, the authors proposed new estimation procedures for determining local wall-thinning to overcome the weakness of the current methods, in which the proposed procedure is based on analysis of variance (ANOVA) method using subgrouping of measured thinning values at all measurement grids. The new procedures were also quantified for their statistical significance. As the results, it is confirmed that the new methods have better estimation confidence than the methods having used until now.

Precise ultrasonic coating and controlled release of sirolimus with biodegradable polymers for drug-eluting stent

  • Joung, Yoon Ki;Jang, Bu Nam;Kang, Jong Hee;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.1 no.1
    • /
    • pp.13-25
    • /
    • 2014
  • In the current study, a drug-eluting stent coated with biodegradable polymers and sirolimus was developed by using an ultrasonic nanocoater and characterized in aspects of surface smoothness and coating thickness. In addition, in vitro release profiles of sirolimus by changing top coating layer with different biodegradable polymers were investigated. Smooth surfaces with variable thickness could be fabricated by optimizing polymer concentration, flow rate, nozzle-tip distance, gas pressure, various solvents and ultrasonic power. Smooth surface could be generated by using volatile solvents (acetone, chloroform, and methylene chloride) or post-treating with solvent vapor. Coating thickness could be controlled by varying injection volume or polymer concentration, and higher concentration could reduce the coating time while obtaining the same thickness. The thickness measurement was the most effectively performed by a conventional cutting method among three different methods that were investigated in this study. Release profiles of sirolimus were effectively controlled by changing polymers for top layer. PLGA made the release rate 3 times faster than PDLLA and PLLA and all top layers prevented burst release at the initial phase of profiles. Our results will provide useful and informative knowledge for developing drug-eluting stents, especially coated with biodegradable polymers.

Estimation of Thickness of Concrete Structures using the Impact Echo Method and Ultrasonic Pulse Velocity Method

  • Hong, Seonguk;Lee, Yongtaeg;Kim, Seunghun;Lee, Changsik
    • Architectural research
    • /
    • v.18 no.4
    • /
    • pp.179-184
    • /
    • 2016
  • The structure must be periodically checked and measures must be taken to prevent deterioration in building construction. From this point of view, a nondestructive test is essential to estimate whether the construction of buildings is proper, and whether the dimension of depositing concrete is consistent and without damage. This study estimated the thickness of the concrete component of construction framework using the ultrasonic velocity method and the impact echo method, in order to investigate reliability of the estimation of the thickness of normal strength concrete and high strength concrete, leading to the following conclusions. In the estimation of the thickness of the concrete structures, specimens of normal strength of 24MPa and specimens of high strength of 40MPa demonstrated an average error rate of 5.1% and 2.2%, respectively. The impact-echo method, one of the non-destructive tests, is verified as an efficient diagnostic technique. With this information, we will determine specific standards for the maintenance of structures, and the re-creation of lost building blueprints.

The Effects of Craniocervical Flexion Exercise on Deep Cervical Flexor Muscle Thickness and Gait for Children with Hemiplegic Cerebral Palsy (머리-목 굽힘 운동이 편측 뇌성마비 환자의 깊은 목 굽힘근의 두께와 보행에 미치는 영향)

  • Yun, Changkyo;Kim, HyunSung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.1
    • /
    • pp.99-105
    • /
    • 2018
  • Purpose : The purpose of this study was to evaluate the effect of craniocervical flexion exercise on deep cervical flexor thickness and gait in children with hemiplegic cerebral palsy. Methods : Twelve children with hemiplegic cerebral palsy were recruited for this study. All subjects performed active craniocervical flexion exercise 3times a week over the course of 6weeks. using a pressure bio feedback unit. Ultrasonography was used to assess deep cervical flexor thickness, and a 10m walking test was used to assess gait function. For the statistical analysis, a paired t-test was used to compare the differences pre- and post-value. SPSS Statistics version 20.0 was used for statistical analysis, and statistical significance was defined as a p-value less than 0.05. Result : The results of this study indicate that children with hemiplegic cerebral palsy experienced statistically significant positive changes in both deep cervical flexor thickness (p<.05). and gait(p<.05) following the intervention. Conclusion : In conclusion, craniocervical flexion exercise can positively affect deep cervical flexor thickness in children with hemiplegic cerebral palsy, which in turn positively affects gait.

Numerical simulation of the effect of bedding layer geometrical properties on the shear failure mechanism using PFC3D

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • v.22 no.5
    • /
    • pp.611-620
    • /
    • 2018
  • In this research the effect of bedding layer angle and bedding layer thickness on the shear failure mechanism of concrete has been investigated using PFC3D. For this purpose, firstly calibration of PFC3d was performed using Brazilian tensile strength. Secondly shear test was performed on the bedding layer. Thickness of layers were 5 mm, 10 mm and 20 mm. in each thickness layer, layer angles changes from $0^{\circ}$ to $90^{\circ}$ with increment of $25^{\circ}$. Totally 15 model were simulated and tested by loading rate of 0.016 mm/s. The results shows that when layer angle is less than $50^{\circ}$, tensile cracks initiates between the layers and propagate till coalesce with model boundary. Its trace is too high. With increasing the layer angle, less layer mobilize in failure process. Also the failure trace is very short. It's to be note that number of cracks decrease with increasing the layer thickness. The minimum shear test strength was occurred when layer angle is more than $50^{\circ}$. The maximum value occurred in $0^{\circ}$. Also, the shear test tensile strength was increased by increasing the layer thickness.

Analysis of Formability and Wrinkle Formation according to the Thickness of Ultra-thin Stainless Steel in the Incremental Sheet forming Process (점진적 판재 성형 공정에서 스텐리스 극박판의 두께에 따른 성형성 및 주름 발생 특성 분석)

  • Lee, J.H.;Lee, G.I.;Jeong, M.S.;Jung, K.S.;Lee, C.W.
    • Transactions of Materials Processing
    • /
    • v.28 no.6
    • /
    • pp.328-335
    • /
    • 2019
  • Demand for ultra-thin materials is increasing due to their light-weight and versatile properties. In this work, the formability of the ultra-thin stainless steel sheets of various thicknesses in the incremental sheet forming (ISF) process is investigated. The effects of the thickness on formability were evaluated with forming experiments of the truncated cone shape with 10° intervals. As the thickness of the material decreased, the maximum forming angle decreased and wrinkles also occurred quickly. The maximum forming angles in the truncated cone shape without the wrinkles for the thickness of 0.05 mm, 0.08 mm, and 0.1mm were 30°, 40°, and 50°, respectively. Wrinkles occurred in a twisted shape along the moving direction of the tool. As the material thickness increased, the size of the wrinkles increased.

Interferometric Measurements of the Thickness Distribution of the Liquid Sheet Formed by Two Impinging Jets (충돌 제트에 의해 형성되는 액막의 두께 특성에 관한 연구)

  • Choo, Yeon-Jun;Kang, Bo-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.214-223
    • /
    • 2000
  • In this research, a study on the characteristics of the liquid sheet formed by two impinging jets is presented. Using the interference phenomena of light, the thickness of the liquid sheet, which seems to heavily affect the size of the droplets, is measured and compared with existing theoretical modelings. Thinner liquid sheet is produced with larger impinging angle, smaller orifice diameter, and higher azimuthal angle but the jet velocity doesn't affect the thickness. More viscous liquid produces thicker liquid sheet. The theoretical modelings predict the same trend as the experiments but the thickness values are overestimated at low azimuthal angles. This difference is gradually decreased as the azimuthal angle is increased: The breakup mechanism of the droplets from the liquid sheet is visualized by a high speed camera. The crest around the edge of the liquid sheet is protruded with the accumulation of liquid at the end of protuberance, which contracts into a spherical shape and then becomes detached when the stem breaks down, producing large droplets with a few small size of satellites.

Effects of Behavior Modification on Obesity Index, Skinfold Thickness, Body Fat9 Serum Lipids, Serum Leptin in Obese Elementary School Children (행동요법이 중ㆍ고도 비만아동의 비만도, 피부두께, 지방량, 혈중지질농도 및 렙틴농도에 미치는 효과)

  • 김효신
    • Journal of Korean Academy of Nursing
    • /
    • v.33 no.3
    • /
    • pp.405-413
    • /
    • 2003
  • Purpose: This study was performed to investigate effects of behavior modification on obesity index, skinfold thickness, body fat, serum lipids, serum leptin in obese elementary school children. Method: Forty seven students were selected from two elementary schools. Twenty four children in one school were assigned to experimental group and twenty three children in another school were assigned to control group. Experimental group was received 60~70 minutes of behavior modification once a week for 8 weeks. Result: Obesity index of the experimental group was significantly decreased after behavior modification. But there was no significant difference between two groups. The increase of skin fold thickness was significantly low in the experimental group compared to the control group. Percentage of body fat and fat mass were significantly decreased in the experimental group. Fat free mass was significantly increased in the experimental group. HDL-C, triglyceride and serum leptin between the experimental group and control group showed no significant difference. Conclusion: These results indicate that behavior modification is effective in decreasing percentage of body fat and fat mass, in less increasing skinfold thickness and in increasing fat free mass. In conclusion, behavior modification can be used as effective strategy for managing obesity in elementary school children.