• Title/Summary/Keyword: THICKNESS

Search Result 26,196, Processing Time 0.051 seconds

Changes in the Volume and Cortical Thickness of the Specific Regions of Cerebellum of Patients with Major Depressive Disorder (주요우울장애 환자에서 소뇌 국소 부위의 부피와 피질 두께의 차이)

  • Kang, Ji-Won;Han, Kyu-Man;Won, Eunsoo;Tae, Woo-Suk;Ham, Byung-Joo
    • Korean Journal of Biological Psychiatry
    • /
    • v.25 no.3
    • /
    • pp.60-71
    • /
    • 2018
  • Objectives A growing body of evidence has suggested that morphologic changes in cerebellum may be implicated with pathophysiology of major depressive disorder (MDD). The aim of this study is to investigate a difference in the volume and cortical thickness of the specific region of cerebellum between patients with MDD and healthy controls (HC). Methods A total of 127 patients with MDD and 105 HC participated in this study and underwent T1-weighted structural magnetic resonance imaging. We analyzed volume and cortical thickness of each twelve cerebellum regions divided by left and right and the volume and cortical thickness of the whole cerebellum from T1-weigted image of participants. One-way analysis of covariance was used to investigate the volume and cortical thickness difference of total and specific regions between two groups adjusting for age, gender, medication, and total intracranial cavity volume. Results We found that the patients with MDD had significantly greater volume in the left cerebellum lobule III region [false discovery rate (FDR)-corrected p = 0.034] compared to HC. Also, our findings indicate that cortical thickness of left lobule VIIB (FDR-corrected p = 0.032) and lobule VIIIB (FDR-corrected p = 0.032) are significantly thinner in the patients with MDD compared with the HC. No significant volume and cortical thickness differences were observed in other sub-regions of the cerebellum. The volumes and cortical thickness of whole cerebellum between patients with MDD and HC did not differ significantly. Conclusions We observed the region-specific volume and cortical thickness difference in cerebellum between the patients with MDD and HC. The results of our study implicate that the information about structural alterations in cerebellum with further replicative studies might provide a stepping stone toward a specific marker to diagnose MDD.

  • PDF

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

Study on functional states and differential diagnosis of ovarian cysts in slaughtered Korean native cows (도축한우에서 난소낭종의 감별진단 및 기능성에 관한 연구)

  • 이청산;류대열;윤호규;송종한;이종인;서국현;김일화;강현구
    • Korean Journal of Veterinary Service
    • /
    • v.27 no.1
    • /
    • pp.41-52
    • /
    • 2004
  • To establish the differential diagnosis and functional status in ovarian cystic cows, progesterone(P$_4$) and estrogen(E$_2$) level of cystic follicular fluid, ultrasonography for measuring the cystic diameter and thickness of cystic wall, and histological findings were investigated in cystic ovaries from slaughtered Korean native cows. Ovarian follicles were classified as systic if the diameter was greater than 25 mm by ultrasonography. Ovarian cysts < 3 mm of cystic wall thickness, < 10 ng/ml P$_4$ concentration and >10 ng/ml E$_2$ concentration were classified follicular cyst, ovarian cysts 3 mm of cystic wall thickness, 10 ng/ml P$_4$ concentration and <10 ng/ml E$_2$ concentration were classified luteal cyst, and ovarian cysts 3 mm of cystic wall thickness, < 10 ng/ml P$_4$ concentration and <10 ng/ml E$_2$ concentration were classified non-functional ovarian cyst, respectively. Also ovarian cysts were classified 8 types by anatomical and hisctological findings. Ovarian cysts with corpus luteum were 3 of 73 cows and ovarian cysts without corpus luteum were 70 cows. The incidence rates of 8 various types of ovarian cysts were as follows; 2Aa 56.2%, 2Ba 20.5% and 2Ab 15.1%, respectively. The incidence rates of ovarian cysts without corpus luteum were follicular cyst 76.7% and luteal cyst 19.2%. The thickness of cystic wall were lAb 3.9 mm, 2Ab 3.3 mm and 2Bb 3.2 mm, and the cystic fluid P$_4$ concentrations were above 10.0 ng/ml in lAb, 2Ab and 2Bb, respectively. There was significantly correlations between the thickness of cystic wall and cystic fluid P$_4$ concentration in ovarian cysts(p<0.05). The ovarian cyst was classified follicular cysts, luteal cyst and non-functional ovarian cyst by hormone analysis. The luteal cyst was accuratly dignosed by cystic wall thickness. But follicular cysts was misdiagnosed 13 cows of 56 cystic cows. The 13 cystic cows was determined as had non-fuctional ovarian cysts. The cystic fluid P$_4$ concentration was 3.3 ng/ml in follicular ovarian cysts and 30.1 ng/ml luteinized ovarian cysts. There was significantly positive correlations between thickness of cystic wall and serum P$_4$ concentration in follicular(r$^2$ =0.59, p<0.001) and luteal cysts(r$^2$=0.65, p<0.001). These results indicated that ovarian cysts had various stages of degeneration and luteal cyst was accuratly diagnosed measurement of cystic wall thickness by ultrasonography, but follicular cysts was not diagnosed only cystic diameter and cystic wall thickness. In conclusion, it is suggest that ovarian cysts was diagnosed by combination of clinical sign and anatomical cystic features.

Magnetic Circular Dichroism Study of co Thin Films on Pd(111) Surface

  • Kim, Wookje;Kim, Wondong;Kim, Hyunjo;Kim, Jae-Young;Hoon Kho;Park, J.H.;Oh, S.J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.169-169
    • /
    • 1999
  • We studied magnetic properties of co thin films deposited on Pd (111) surface, which attracted much attention recently due to the perpendicular magnetic anisotropy, using magnetic circular dichroism(MCD). Special attention was paid on the effect of Pd capping and interface roughness on the direction of magnetic easy axis, and for that purpose MCD signals for all Co thicknesses were measured with two different ways : in-plane and out-of-plane geometry. In case of bare Co films deposited on smooth Pd(111) surface, no MCD signal was observed under 4$\AA$ co thickness. At 4$\AA$ Co thickness, MCD signal at the out-of-plane geometry was observed, and for thicker Co films, only in-plane MCD signal was measured. This type of magnetic easy axis transition has been reported for other cases like Co/Pt system. The effect of 5$\AA$ Pd capping on these bare Co films made an remarkable change on the transition of magnetic easy axis. Out-of-plane MCD signals exists up to 20$\AA$ Co thickness, and disappears at 24$\AA$ Co thickness. In-plane MCD signals first appears at 10$\AA$ Co thickness and gradually increases up to 24$\AA$ Co thickness. Between 10$\AA$ and 20$\AA$ Co thickness, in-plane and out-of-plane MCD signal coexist. The formation of multi-domain structure or the existence of tilted magnetic easy axis is an possible scenario for such an interesting coexistence. The effect of interface roughness was also tested by measuring MCD signal on Co films deposited on un-annealed Pd(111) surface. Out-of-plane MCD signal was observed up to 8$\AA$ Co thickness and the anisotropy of MCD signal at 4$\AA$ Co thickness was very large with respect to that of Co film deposited on the smooth substrate. Above 8$\AA$ thickness, there exists only in-plane MCD signal. From above results, it was concluded that both Pd capping and interface roughness induce and reenforce the perpendicular magnetic anisotropy. The large perpendicular magnetic anisotropy of Co/Pd multilayer system made by sputtering method can be well understood from our results.

  • PDF

Evaluation on Adaptation of Zosia japonica as Effected by Different Green Roof System under Rainfed Conditon (무관수 옥상녹화시스템의 차이에 따른 들잔디 적응성 평가)

  • Ju, Jin-Hee;Kim, Won-Tae;Choi, Woo-Young;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.19 no.9
    • /
    • pp.1137-1142
    • /
    • 2010
  • This study proposes a guideline of a green roof system suitable for the local environment by verifying the growth of Zoysia japonica in a shallow, extensive, green roof system under rainfed condition. The experimental soil substrates into which excellent drought tolerance and creeping Z. japonica was planted were made with different soil thicknesses(15cm, 25cm) and soil mixing ratios(SL, $P_7P_1L_2$, $P_6P_2L_2$, $P_5P_3L_2$, $P_4P_4L_2$). The plant height, green coverage ratio, fresh weight, dry weight and chlorophyll contents of Z. japonica were investigated. For the soil thickness of 15cm, the plant height of Z. japonica was significantly as affected by the soil mixing ratio and it was shown in the order SL= $P_4P_4L_2$ < $P_7P_1L_2$ = $P_5P_3L_2$ < $P_6P_2L_2$. For the soil thickness of 25cm, the plant height was increased in order to SL < $P_7P_1L_2$, $P_6P_2L_2$, $P_5P_3L_2$ < $P_4P_4L_2$. The green coverage ratio was not observed by soil the mixing ratio or soil thickness. However, the green coverage ratio was 86~90% with a good coverage rate overall. The chlorophyll contents of Z. japonica were not significantly affected by the soil mixing ratio in the soil thickness of 15cm, but were higher in the natural soil than in the artificial soil at 25cm soil thickness. The fresh weight and dry weight of Zoysia japonica were heavier in the 25cm thickness than in the 15cm thickness and in the artificial soil mixture than in the natural soil. The result indicated that the growth of Zoysia japonica was more effective in the 25cm soil thickness with artificial soil than in the 15cm soil thickness with natural soil in the green roof system under rainfed condition.

Risk Analysis of Factors for Metabolic Diseases according to the Epicaridal Adipose Tissue Thickness - which Focused on the Presented Subjects with Asymptomatic Screening Purposes (심장외막의 지방두께에 따른 대사질환의 위험도 분석 - 무증상의 검진목적으로 내원한 대상자를 위주로)

  • Kim, Sun-Hwa;Kim, Jung-Hoon;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.7
    • /
    • pp.476-483
    • /
    • 2016
  • Epicardial adipose tissue(EAT) is metabolically active endocrine organ that secretes several hormones in fat thickness is a risk factor for cardiovascular disease and metabolic disorders. This study was to measure and then using ultrasound epicardial adipose tissue thickness, abdominal subcutaneous fat thickness in the target group correlates and general blood properties and characteristics, and presents a local thickness for prediction of metabolic disorders. Results epicardal adipose tissue of the average thickness measured in each of the subjects was 8.890mm, 4.783mm, 4.777, 6.147mm in each section. Showed the epicardial adipose tissue in correlation with the average thickness of the risk factors age, BMI, SBP, LDH, LDL, TC is a positive correlation relationship(p<0.05) in each section. In particular, the thickness of the metabolic disorders epicardial adipose tissue thickness, abdominal subcutaneous compared to subjects that do not have the risk subjects with a risk factor for fat significantly higher(p<0.05). It showed the most reliable that can be cut-off value of 8.950mm obtained with 66.7 % sensitivity and 80 % specificity for predicting the risk of metabolic disorders.

THE INFLUENCE OF PORCELAIN LAYER THICKNESS AND COLOR ON THE FINAL SHADE OF CERAMIC RESTORATIONS (도재층의 두께와 색이 도재수복물의 최종 색조에 미치는 영향)

  • Seong Dong-Hwan;Lee Im-Gi;Sohng Jin-Won;Bok Won-Mi;Ahn Seung-Geun;Park Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.587-598
    • /
    • 2005
  • Statement of problem: Ceramic restorations should be made of porcelain layers of different opacity, shade, and thickness in order to provide a natural appearance. Lithium disilicate glass-ceramic system has superior color reproducibility, because it uses the ceramic ingot which is similar to teeth shade and uses the staining technique and layering technique. However, staining technique has a fault of discoloration. Also, porcelain is divided core and dentin layer, it is not enough to study about the influence of porcelain layer thickness and shade on the shade of ceramic restorations. Purpose: The purpose of this study was to evaluate the influence of porcelain layer thickness and color on the final shade of ceramic restorations. Materials and method: The CIE $L^*a^*b^*$(CIELAB) values of 72 assembled specimens, each consisting of 3 discs (enamel porcelain 0.2 mm/dentin porcelain -1.2, 0.9, 0.7, 0.5 or 0.3 mm/ceramic core -0.3, 0.5, 0.7, 0.9 or 1.2 mm, diameter is 1.0 mm) were evaluated with a spectrophotometer (Model Chromaview 300, Spectron Tech Co, Korea) for the shade A1, A2, A3 and A4. Distilled water (refractive index: 1.7) was used to attain optical contact between the layers. White, white gray, and white brown backgrounds were used to assess the influence of the background on the final shade. And the mean color difference value$({\Delta}E)$ was calculated. Results and conclusion: The results obtained from this study were as follows. 1. There was a significant correlation between the thickness ratio of the ceramic core/dentin porcelain system and $L^*,\;a^*\;and\;b^*$ values when the total thickness of specimen combination was smaller than 1.4 mm(P<0.05). 2. The specimen which the ceramic core thickness was more than 0.7 mm had the best masking effect against background colors. 3. The mean color difference value$({\Delta}E)$ is smaller than 2 $({\Delta}E<2)$ when the ceramic core thickness was larger than 0.7 mm and the total thickness of specimen was more than 1.4 mm.

Emission Characteristics of Dual Emission Tandem OLED with Charge Generation Layer MoOx and Cathode Al Thickness (전하생성층 MoOx와 음극 Al의 두께에 따른 양면발광 적층 OLED의 발광 특성)

  • Kim, Ji-Hyun;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.3
    • /
    • pp.316-321
    • /
    • 2016
  • To study emission characteristics for dual-emission tandem organic light emitting display (OLED), we fabricated blue fluorescent OLED according to thickness variation of $MoO_x$ as charge generation layer and Al as cathode. The bottom emission characteristics of OLED with $MoO_x$ 2, 3, 5 nm thickness showed threshold voltage of 9, 7, 9 V, maximum current emission efficiency of 19.32, 23.18, 15.44 cd/A and luminance of $1,000cd/m^2$ at applied voltage of 17.6, 13.2, 16.5 V, respectively. The top emission characteristics of OLED with $MoO_x$ 2, 3, 5 nm thickness indicated threshold voltage of 13, 10, 13 V, maximum current emission efficiency of 0.17, 0.23, 0.16 cd/A and luminance of $50cd/m^2$ at applied voltage of 22.6, 16.5, 20.1 V, respectively. In case of thicker or thinner than $MoO_x$ of 3 nm, the emission characteristics were decreased because of mismatching of electron and hole in emission layer. The bottom emission characteristics of OLED with Al 15, 20, 25 nm thickness showed threshold voltage of 8, 8, 7 V, maximum current emission efficiency of 18.42, 22.98, 23.18 cd/A and luminance of $1000cd/m^2$ at applied voltage of 16.2, 13.9, 13.2 V, respectively. The reduction of threshold voltage and increase of maximum current emission efficiency are caused by the increase of current injection according to increase of Al cathode thickness. The top emission characteristics of OLED with Al 15, 20, 25 nm thickness indicated threshold voltage of 7, 7, 8 V, maximum emission luminance of 371, 211, $170cd/m^2$, respectively. The top emission OLED of Al cathode with 15 nm thickness showed maximum luminance and it decreased at thickness of 20 nm. These phenomena are caused by the decrease of intensity of emitted light by reduction of optical transmittance according to increase of Al cathode thickness.

Thickness Effects on the Fatigue Strength of Butt Welded Specimens using SM520C-TMC Steel (SM520C-TMC 강재의 피로강도에 대한 두께효과)

  • Kim, Kyoung Nam;Jung, In Su;Hwang, Nak Yeon;Jung, Kyoung Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.6 s.73
    • /
    • pp.847-855
    • /
    • 2004
  • The criterion or specification on fatigue design has been generally based on fatigue strength curve derived by tests on specimens with varying thickness (10-30mm). Making the plate thicker, however, also decreases fatigue strength. It has been noted from the test results and the results of the analysis by fracture mechanics that the effect of thickness cannot be bypassed. From the several fatigue strength curves of specimen tests, modification of fatigue strength on plate thickness has been proposed. In this study, fatigue tests on SM520C-TMC were carried out, and the effects of thickness were evaluated. Finally, in consideration of the thickness, the modification of fatigue strength was derived. Comparing the results of this paper with those of previous studies, an outline of the behavior obtained is similar to previous ones, but the rate of decrease is smaller.

Effect of Roundness Error of a Crank Pin Bearing for a Marine Engine on the Minimum Film Thickness (박용엔진 크랭크 핀 베어링의 형상오차가 최소유막두께에 미치는 영향)

  • Ha, Yang-Hyup;Shin, In-Dong;Lee, Sang-Min;Lee, Seung-Jun;Lee, Deug-Woo
    • Tribology and Lubricants
    • /
    • v.27 no.5
    • /
    • pp.256-263
    • /
    • 2011
  • Bearings of marine engines are operated under severe conditions because of dynamic load and low sliding speed. This paper deals with lubrication analysis of a crank pin bearing for a marine diesel engine. Journal center locus and oil film thickness are compared of crank pin bearing. In the past researches, journal bearings have been studied only about the surface of bearing. In addition to this conventional research, this paper analyzes the effect of roundness error of a journal and a bearing on the minimum film thickness. Numerical analysis has been studied by using Reynolds equation and also Half-Sommerfeld condition is applied as boundary condition. Futhermore, this study investigates the effect of roundness error change on the minimum film thickness. The results demonstrate that the bigger amplitude of roundness error yields, the lower minimum oil film thickness is. In comparison to previous research considered a journal and a bearing individually, the results considering a journal and a bearing together show that amplitude of roundness error of journal has very little effect on the minimum oil film thickness.