• 제목/요약/키워드: THICKNESS

검색결과 26,125건 처리시간 0.042초

A Study on Span to Depth Ratio for Minimum Thickness of One-Way Slab

  • Choi, Bong-Seob;Kwon, Young-Wung
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.45-52
    • /
    • 1999
  • A Computer-based iterative method is provided for the calculation of minimum thickness values for one-way slabs to satisfy the maximum permissible limits given in the ACI Building Code. An algorithm includes the effects of cracking and time-dependent effects due to creep and shrinkage. Comparison of the calculated minimum thickness values with the current ACI limits is conducted to investigate limitations of the current tabulated minimum thickness. which are constant to a range of design conditions.

  • PDF

관상동맥우회 이식편으로서의 우위대망동맥의 조직학적 특징 (Histological Characteristics of Right Gastroepiploic Artery for Coronary Artery Bypass Graft)

  • 이현우;송현;유동곤;임한중;이재원;송명근
    • Journal of Chest Surgery
    • /
    • 제32권10호
    • /
    • pp.883-890
    • /
    • 1999
  • Long term patency of arterial graft has been better than venous graft and redo coronary artery bypass grafting has been increasing, therefore, there has been an increasing need for alternative arterial grafts except internal thoracic artery(ITA). Material and Method: Right gastroepiploic arteries(RGEA) were harvested from 100 patients who had received gastrectomy for gastric cancer or ulcer. ITAs were obtained from 10 patients undergoing coronary artery bypass grafting. The length of RGEA was measured from the pyloric ring. Items of the morphometric and histologic study at the pyloric ring and sites of the 10cm and 20cm RGEA from the pyloric ring were luminal diameter, intimal thickness, medial thickness, wall thickness, degree of intimal hyperplasia, intimal thickness, medial thickness, wall thickness, degree of intimal hyperplasia, intimal thickness index, medial thickness index, and the number of discontinuities of the internal elastic lamina. Similar items were applied to the proximal site of ITAs. Result: The length of RGEA was 23${\pm}$2.7cm(range 17∼31cm). Comparing the 20cm RGEA with ITA, intimal thickness, medial thickness, wall thickness, and degree of intimal hyperplasia did not show any difference(p>0.05). However, 20cm RGEA was greater than ITA at the luminal diameter, intimal thickness index, and the number thickness and wall thickness in each site of the RGEA(pyloric ring, 10cm, 20cm) decreased from the pyloric ring to the distal sites(p<0.05). The degree of intimal hyperplasia and the number of discontinuities of the internal elastic lamina did not show any difference between the pyloric ring and 10cm, however, those of 20cm were smaller than these sites(p<0.05). RGEA had more number of discontinuities of the internal elastic lamina and rich smooth muscle cells in the media than ITA. Conclusion: The length and diameter of RGEA is good enough to reach most of the coronary arteries. Moreover, long term patency of RGEA may be improved, if anastomosed in the distal site.

  • PDF

혈중 인슐린 및 렙틴이 한우 지방형질에 미치는 효과 (Effects of plasma insulin, and leptin on fat traits in Hanwoo (Korean cattle))

  • 김형철;이승환;당창권;임다정;최봉환;장선식;조영무;전기준;박응우;조용민;이준헌;양보석;홍성구
    • 농업과학연구
    • /
    • 제39권2호
    • /
    • pp.203-209
    • /
    • 2012
  • The objective of this study was to examine the effect of plasma leptin and insulin concentrations on fat traits in Hanwoo. If a biological indicator such as plasma leptin and insulin was identified, it would be a useful biological marker that can be predicted marbling score in young animal. The relationship between plasma hormone (leptin and insulin) and fat traits (marbling score, back fat thickness and P8 fat thickness) was investigated. The experiment studies 100 Hanwoo that were randomly sampled from Hanwoo Experimental Station Herd. The concentration of plasma insulin was significantly associated with marbling score (P=0.02) but was not significantly with back fat thickness (P=0.07) and P8 fat thickness (P=0.09). Statistical model determinant that plasma insulin concentration account for phenotypes was moderate on marbling score (5%), back fat thickness (3%) and P8 fat thickness (9%). On the other hand, plasma leptin concentration was significantly associated with marbling score (P=0.03) and back fat thickness (P=0.02), but was not significant on P8 fat thickness (0.07). Statistical model determinant that plasma leptin concentration accounting for phenotypes was moderate effect on marbling score (3%) and back fat thickness (2%), but it has a slightly bigger effect on P8 fat thickness (7%). In conclusion, the plasma leptin and insulin seems to have an effect on fat traits (marbling score, backfat thickness and P8 fat thickness) in Hanwoo.

광중합복합레진의 두께에 따른 투명도 차이가 수복물의 색상에 미치는 영향 (TRANSLUCENCY OF LIGHT CURED COMPOSITE RESINS DEPENDS ON THICKNESS & ITS INFLUENCE ON COLOR OF RESTORATIONS)

  • 황인남;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.585-603
    • /
    • 1999
  • Esthetic availabilities used as an esthetic restorative maternals can be determined by the optical coincidence among materials, enamel and dentin. Enamel is highly translucent. That's why esthetic materials need to correspond the close translucency of enamel. But the translucent materials are affected by the background color. So it should be predicted that the color of estorative materials depend on the any thickness and the spectral reflectance of the background on which they are placed. The object of this investigation, under above hypothesis, was to determine and analyze how they affect the final color according to the thickness, translucency and background color (white, black and dentin) fill three commercial light cured composite resins(Charisma, Spectrum TPH and Z100). And correlation was analyzed to find out the possibility of the prediction when using the certain background color and thickness of materials. Followings are the result 1. The I shade of CHA showed the lowest contrast ratio($Co_7$) while the B3 shade of Z100 showed the highest contrast ratio(p<0.05). 2. The value of $L^*$ and $b^*$ on the white and dentin background is increased with decreasing thickness. And there are significant relationships between increasing thickness and each value(R>0.085). But there is a little change of $L^*$ and $b^*$ value on the black background regardless of the thickness(p>0.05). 3. For the $a^*$ value, there was little difference in values as a function of thickness and changed irregularly regardless of thickness in all background. 4. The pattern of increasing value of $L^*$ and $b^*$ with decreasing thickness was similar to the group of white and dentin background. In both dentin one showed lesser change of value. 5. The values of $L^*a^*b^*$ measured on the different background with same thickness showed the recognizable color difference(${\Delta}E^*$>2) when the thickness was below 2.6mm. 6. Contrast ratio was increased with increasing thickness with significant relationship (R>0.9). 7. Spectral reflectance of composite resins that calculated from Kubelka-Munk equation was showed little difference compared with observed value w1th decreasing thickness.

  • PDF

Preparation of harvested skin using the Versajet Hydrosurgery System in full-thickness skin grafts

  • Choi, Seo Gil;Shin, Hyun Woo;Yoon, Kun Chul
    • Archives of Plastic Surgery
    • /
    • 제46권6호
    • /
    • pp.603-607
    • /
    • 2019
  • During a full-thickness skin graft procedure, the thickness of the harvested donor skin is adjusted based on the location of the recipient site and the judgment of the surgeon. Conventionally, the thickness of the harvested skin is roughly adjusted using surgical instruments such as scalpels and scissors. However, this method is not only time-consuming, but also requires effort to obtain both the desired thickness of the harvested skin and a smooth surface of that skin. Moreover, there is a possibility of skin perforation. Hence, the authors devised a method of adjusting harvested skin thickness using the Versajet Hydrosurgery System. The Versajet device is a handheld hydrosurgical tool that delivers a high-speed jet stream of saline solution, which enables the precise debridement of tissue. This method makes it easier and faster for the surgeon to obtain the desired thickness of harvested skin. In addition, by obtaining a smooth surface and an even thickness of harvested donor skin, this technique may lead to improved graft viability.

후판 압연 시 공정변수 및 선단부의 온도저하가 두께편차에 미치는 영향 (The Effect on the Thickness Variation According to Rolling Condition and Temperature Drop At Top-end in Plate Rolling)

  • 임홍섭;주병돈;이혜경;서재형;문영훈
    • 열처리공학회지
    • /
    • 제22권1호
    • /
    • pp.16-22
    • /
    • 2009
  • The rolling process is an efficient and economical approach for the manufacturing of plate metals. In the rolling process, the temperature variation is very critical for plate thickness accuracy. The main cause of thickness variation in hot plate mills is the non-uniform temperature distribution along the length of the slab. Also the exit plate thickness is mainly affected by the rolling conditions such as mill modulus, plate thickness and plate width. Hence the thickness variation in top-end is also dependent on these factors. Therefore this study has concentrated on determining the correct amounts of thickness variation due to top-end temperature drop and process parameters.

Evaluation of crystallinity and defect on (100) ZnTe/GaAs grown by hot wall epitaxy

  • Kim, Beong-Ju
    • 한국결정성장학회지
    • /
    • 제12권6호
    • /
    • pp.299-303
    • /
    • 2002
  • The relationship of crystallinity between defects distribution with (100) ZnTe/GaAs using HWE growth was investigated by four crystal rocking curve (FCRC) and transmission electron microscopy (TEM). The thickness dependence of crystal quality in ZnTe epilayer was evaluated. The FWHM value shows a strong dependence on ZnTe epilayer thickness. For the films thinner than 6 ${\mu}{\textrm}{m}$, the FWHM value decreases very steeply as the thickness increases. For the films thicker than 6 ${\mu}{\textrm}{m}$, it becomes an almost constant value. At the thickness of 12 $\mu\textrm{m}$ with the smallest value of 66 arcsec. which is the best value so far reported on ZnTe epilayers was obtained. Investigation into the nature and behavior of dislocations with film thickness in (100) ZnTe/(100)GaAs heterostructures grown by Hot Wall Epitaxy (HWE). This film defects range from interface to 0.7 ${\mu}{\textrm}{m}$ thickness was high density, due to the large lattice mismatch and thermal expansion coefficients. The thickness of 0.7~1.8 ${\mu}{\textrm}{m}$ was exists low defect density. In the thicker range than 1.8 ${\mu}{\textrm}{m}$ thickness was measured hardly defects.

피로균열진전에 미치는 시편 두께의 영향 (Effect of Specimen Thickness on Fatigue Crack Growth)

  • 김재훈;김영균;윤인수
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.79-86
    • /
    • 1998
  • The effect of specimen thickness on fatigue crack growth behavior has been carried out by compact tension specimens of thickness of 3mm, 10mm and 25mm for maraging steel and Al 7075-T6. The closure points were determined during the test by means of a clip-gage situated at the notch mouth. Specimen thickness have no apparent influence on the fatigue crack growth rate of maraging steel, but the crack growth rate of 25mm thickness specimen for Al 7075-T6 is faster than that of 3 and 10mm specimens. The difference of crack growth rates can be successfully explained by considering the different stress state of plane strain and plain stress due to the variation of specimen thickness. Also the crack opening ratio of 25mm specimen is greater than those of 3 and 10mm specimens. When a side groove is introduced in a 10mm specimen, the crack growth rate is approximately similar to that of 25mm specimen. The effective thickness expression of $B_e=B_o-(B_o-B_N)^2B_o$ is the most appropriate to evaluate the crack growth rate of side-grooved specimen. Fatigue crack growth rates can be well described by $\Delta K_{eff}$ of the crack closure points in regardless of all thickness and side-grooved specimens.

  • PDF

지반과 구조물사이의 상호작용을 고려한 변단면 도통형쉘의 해석 (I) -변단면 쉘의 역학적 특성 (I)- (An analysis of ground supported farm silo with variable thickness (I) -Part I mechanical characteristics of shell with Variable thickness-)

  • 조진구;조현영
    • 한국농공학회지
    • /
    • 제31권4호
    • /
    • pp.58-71
    • /
    • 1989
  • This study aims to develop a computerized program for analysis of the ground-supported cylindrical shell structure with step varied section and to find out its mechanical characteri- stics through application of the developed program to the analysis of a ensiled farm silo as a model structure. The thickness of wall and bottom-plate of farm silo is assumed to be step-varied and its detailed structural dimensions are presented in Tab. 1 and 2. Several numerical case studies show that sectional stresses of the sample structures are largely reduced by adopting "varied section" design technique. And, other major results ob- tained from this study are summarize4 as follows ; 1. The variation of wall-thickness has a great influence on bending stresses of wall. Ho- wever, the larger the relative thickness of bottom-plate is, the smaller the influence is. 2. The magnitude of thickness of projecting toe of bottom-plate has negligible effect on sectional stresses 3. The conventional design methodology, which assumes the bottom edge of wall as clam- ped on ground, is proved to be discarded through the numerical analysis. 4. It is found that the "varied section" design technique should get similar effects as in the case of thick bott6m-plate having uniform thickness. 5. The variation of wall-thickness has a considerable effect on the bending stresses of bo- ttom-plate. Especially, this phenomenon is very remarkable in its projecting toe. In some cases. the negative bending moment may be acted on.

  • PDF

자전거 프레임 튜브 두께에 따른 구조적 내구성 해석 (Structural Durability Analysis According to the Thickness of Bicycle Frame Tube)

  • 조재웅;한문식
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.122-129
    • /
    • 2012
  • This study investigates structural and vibration analyses according to the thickness of bicycle frame tube. The model of bicycle frame has the dimension as length of 862mm, width of 100mm and hight of 402.5mm. There are 3 kinds of models with tubes of top, down and seat at bicycle frame as thicknesses of 10, 15 and 20mm. The maximum displacement and stress occur at the center part of seat stay and at the installation part of rear wheel respectively. Maximum displacements become 0.031936, 0.029159 and 0.027984mm in cases of thicknesses of 10, 15 and 20mm respectively. In case of thickness of 20mm among 3 cases, maximum displacement becomes lowest. But maximum stresses become 10.019, 8.5492 and 9.2511MPa in cases of thicknesses of 10, 15 and 20mm respectively. In case of thickness of 15mm among 3 cases, maximum stress becomes lowest. There is no resonance at practical driving conditions and natural frequency remains almost unchanged along the change of thickness. In case of the displacement due to vibration mode, the displacement difference at thickness between 15mm and 20mm becomes 1/2 times than that between 10mm and 15mm. Design at bicycle frame tube becomes most economical and durable effectively in case of thickness of 15mm among 3 cases.