• Title/Summary/Keyword: THD analysis

Search Result 181, Processing Time 0.022 seconds

Analysis and Design of a Novel-Shape Permanent Magnet Synchronous Motor for Minimization of Torque Ripple and Iron Loss

  • Kim, Jin-Hong;Seo, Jung-Moo;Jung, Hyun-Kyo;Won, Chung-Yuen
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.411-417
    • /
    • 2014
  • This paper presents the shape optimization of a permanent magnet synchronous motor to reduce the torque ripple and iron loss. Specifically, the harmonics of the electromotive force and cogging torque are decreased by adjusting the permanent magnet arrangement and non-uniform air gap length. In addition, an additional flux path along the q-axis is proposed with a unique rotor shape to increase the q-axis inductance and reluctance torque. The improvement in the performance of the proposed model is verified with simulated and experimental results.

A Study on the Transient Characteristics in 765kV Untransposed Transmission Systems (765kV 비연가 송전계통 과도 특성에 관한 고찰)

  • 안용진;강상희
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.397-404
    • /
    • 2004
  • This paper describes a study of transient characteristics in 765kV untransposed transmission lines. As the 765(kV) system can carry bulk power, some severe fault on the system nay cause large system disturbance. The large shunt capacitance and small resistance of 765kv transmission line make various difficulties for its protection. These problems including current difference between sending and receiving terminals on normal power flow, low order harmonic current component in fault current and current transformer saturation due to the long DC time constant of the circuit etc. must be investigated and solved. The analysis of transient characteristics at sending terminal has been carried out for the single phase to ground fault and 3-phase short fault, etc. The load current, charging current in normal condition and line flows, fault current, THD(Total Harmonic Distortion) of harmonics, time constants have been analysed for the 765kV untransposed transmission line systems.

Harmonic Reduction of Parallel-Connected Thyristor Rectifiers with an Active Interphase Reactor

  • Choi, Sewan;Oh, Junyong;Kim, Kiyong
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.276-280
    • /
    • 1998
  • This paper proposes a harmonic a harmonic reduction technique of the parallel-connected twelve-pulse thyristor rectifiers. The proposed system is an improvement over the diode rectifier system with an active interphase reactor [2]. In this scheme, a low KVA (0.15 Po (PU) ) active current source injects a triangular current into an interphase reactor of a twelve-pulse thyristor rectifier along the phase delay angle. The current injection results in near sinusoidal input current with less than 1% THD. Detailed analysis of the proposed scheme along scheme along with design equations is illustrated. Simulation results verify the concept.

  • PDF

Analysis and Measurement of Current Harmonics Due to Non-linear Load in Low Voltage System (저압 시스템에서 비선형 부하의 사용에 따른 전류 고조파 해석 및 측정)

  • Kim, Jong-Gyeom;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.601-608
    • /
    • 2001
  • The ever increasing density of adjustable speed drives(ASD) device with non-linear operating characteristics has been to put tremendous harmonic stress on end user's electrical application. All ASD controllers which employ solid state power devices cause harmonic currents in the source side line. This paper describes harmonic problems for use of ASD. In order to investigate the effect of harmonics caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current waveforms. Measurement results show that additional operation of linear load at the parallel bus with nonlinear load such as ASD is helpful to the reduction of harmonic influence.

  • PDF

Harmonics Analysis for Interconnecting Distributed Resource with Power System Based on PSCAD (PSCAD를 이용한 분산전원 배전계통 연계시 고조파 영향 분석)

  • Park, Jae-Gyun;Kim, Sung-Jin;Ahn, Jong-Hyun;Kim, Re-O;Oh, Yong-Taek
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.411-414
    • /
    • 2009
  • 본 논문에서는 PSCAD 시뮬레이션을 이용하여 실계통도와 유사한 배전계통 분산전원 연계 시스템을 모델링하였다. 모델링한 계통도의 연계지점에 따른 THD와 TDD를 시뮬레이션하고, 고조파 연계기준(IEEE Std 1547와 IEEE Std 519)을 적용하여 기존의 전력계통에 태양광발전 시스템 연계시 발생되는 고조파를 평가하였고 평가결과를 분석하였다.

  • PDF

Analysis of the Electronic Ballast with Semi-boost PFC for Fluorescent Lamps (Semi-boost PFC에 의한 형광등용 전자식 안정기 해석)

  • Han, Jae-Hyun;Jo, Gye-Huyn;Park, Chong-Yeun
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.35-39
    • /
    • 2003
  • There are many kinds of electronic ballast for various kinks of fluorescent lamps. The PFC(Power Factor Correction) circuit in electronic ballast is classified in two types. One is the active PFC and the other is the passive PFC circuit. The active type PFC is higher than the passive type, but the cost of the passive type is cheaper than the active type. In this study, we introduced the modified passive PFC method which is called semi-boost PFC, and then we analyzed and experimented the electronic ballast which is composed of the semi-boost PFC, half-bridge, and LCC resonant tank. Experimental results showed that the $$PF{\geq_-}0.98$$, $$CF{\leq_-}1.4$$ and input current $THD{\approx}15%$.

  • PDF

Development of PWM Converter System for Sapphire Silicon Ingot Glowing of 80kW 10kA (사파이어 실리콘 결정 성장용 80kW 10kA PWM 컨버터 시스템 개발)

  • Kim, Min-Huei;Park, Young-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.33-41
    • /
    • 2014
  • This paper is research result for a development of sapphire silicon ingot glowing(SSIG) PWM converter system for 80kW 10kA. The system include 3-phase AC-DC diode rectifier of input voltage AC 380V and 60Hz, DC-AC single phase full bridge PWM inverter of high frequency, AC-DC single-phase full wave rectifier using center-tapped of transformer for low voltage 8.0V and large current 10,000A of output specification, tungsten resistor load 0.1[$m{\Omega}$]. PWM switching frequency for IGBT inverter control set 30kHz. The suggested researching contents are designed data sheets of power converter system, PSIM simulation, operating characteristics and analysis results of developed SSIG system. This paper propose

Comparative Analysis of Three-Phase AC-DC Converters Using HIL-Simulation

  • Raihan, Siti Rohani Sheikh;Rahim, Nasrudin Abd.
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.104-112
    • /
    • 2013
  • This paper presents a comparative evaluation of various topologies for three-phase power converters using the hardware-in-the-loop (HIL) simulation technique. Various switch-mode AC-DC power converters are studied, and their performance with respect to total harmonic distortion (THD), efficiency, power factor and losses are analyzed. The HIL-simulation is implemented in an Altera Cyclone II DE2 Field Programmable Gate Array (FPGA) Board and in the Matlab/Simulink environment. A comparison of the simulation and HIL-simulation results is also provided.

A Study on the Novel Space Vector Based Harmonic Elimination Method of Inverter (인버터 고조파 저감을 위한 새로운 공간벡터 변조기법에 관한 연구)

  • Lee, Sang-Taik;Kim, Hee-Jun;Oh, Won-Seok;Shin, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1236-1238
    • /
    • 2000
  • This paper considers the problem of eliminating harmonics in the inverter output waveforms. The approach is based on the minimization of the current harmonics in the induction motor by space vector modulation method. Reference voltage is compensated with injection of controlled current harmonics which are calculated to reduce current harmonics through sampled current harmonic analyzing algorithm. The theoretical analysis is carried out using computer simulation. It is verified that proposed SVM technique could reduce current harmonic component and improve THD.

  • PDF

The Circuit Parameters Determination of Voltage-Sag Compensator (순간전압강하 보상기의 회로파라미터 설정)

  • Kim, Hong-Kwon;Lee, Eun-Woong;Lim, Su-Saeng;Kim, Jun-Ho;Jeon, Bok-Su
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.795-797
    • /
    • 2000
  • The analysis model of voltage-sag compensator is achieved in synchronous rotating coordinates. Inverter's LC filter and DC-link capacitor is designed in order to reduce THD of output voltages and LC filter's size And the circuit parameters of voltage-sag compensator is presented for 3-phase Customer.

  • PDF