• Title/Summary/Keyword: TG feedback

Search Result 13, Processing Time 0.022 seconds

Development of the New Inverter Control System for TG Feedback a formula Control (Inverter Control System을 이용한 TG Feedback 제어기 개발)

  • Cho Hyoun-Seob;Min Jin-Kyoung;Song Young-Deog
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.191-193
    • /
    • 2005
  • In this paper new, inverter control system for TG feedback a formula Control was developed. The motor control system with TG feedback controller as an effect of load disturbance, it is very difficult to guarantee the robustness of control system. The function of the implementation we TG feedback type, and temperature scheme. The Inverter Control System approach is based on master-slave control concept. To show validity of the developed new inverter control system, several experiments are illustrated.

  • PDF

Development of the New Inverter Control System for TG Feedback a formula Control (P/M의 TG Feedback방식을 제어하기 위한 인버터 시스템 적용에 관한 연구)

  • Cho, Hyeon-Seob;Ryu, In-Ho;Min, Lin;Oh, Hun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2493-2494
    • /
    • 2002
  • In this paper new inverter control system for TG feedback a formula Control was developed. The motor control system with TG feedback controller as an effect of load disturbance, it is very difficult to guarantee the robustness of control system. The function of the implementation are TG feedback type, and temperature scheme. The Inverter Control System approach is based on master-slave control concept. To show validity of the developed new inverter control system, severial experiments are illustrated.

  • PDF

Development of the New Inverter Control System for TG Feedback a formula Control (TG Feedback 방식을 제어하기 위한 새로운 Inverter Control System 개발)

  • Cho, Hyeon-Seob;Ryu, Byoung-Sik;Ryu, In-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2437-2438
    • /
    • 2001
  • In this paper new, inverter control system for TG feedback a formula Control was developed. The motor control system with TG feedback controller as an effect of load disturbance, it is very difficult to guarantee the robustness of control system. The function of the implementation are TG feedback type, and temperature scheme. The Inverter Control System approach is based on master-slave control concept. To show validity of the developed new inverter control system, severial experiments are illustrated.

  • PDF

Design of the Inverter Control System of Punching M/C (Punching M/C의 인버터 제어기 설계)

  • Cho, Hyeon-Seob;Jun, Ho-Ik
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.132-134
    • /
    • 2010
  • In this paper new, inverter control system for TG feedback a formula Control was developed. The motor control system with TG feedback controller as an effect of load disturbance, it is very difficult to guarantee the robustness of control system. The function of the implementation are TG feedback type, and temperature scheme. The Inverter Control System approach is based on master-slave control concept. To show validity of the developed new inverter control system, severial experiments are illustrated.

  • PDF

Inverter Control System Design for Tacho Generator Feed Back Control (Tacho Generator Feed Back 제어를 위한 Inverter Control System 설계)

  • Cho, Hyun-Seob;Roh, Yong-Gi;Jang, Sung-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1941-1942
    • /
    • 2006
  • In this paper new, inverter control system for TG feedback a formula Control was developed. The motor control system with TG feedback controller as an effect of load disturbance, it is very difficult to guarantee the robustness of control system. The function of the implementation are TG feedback type, and temperature scheme. The Inverter Control System approach is based on master-slave control concept. To show validity of the developed new inverter control system, severial experiments are illustrated.

  • PDF

Development of Inverter Control System for Punching M/C (Punching M/C의 Inverter Control System개발)

  • 조현섭;민병조
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.11a
    • /
    • pp.173-176
    • /
    • 2001
  • A company needs to maintain its machines always workable in order to keep the manufacturing time minimal. If any troubles un, they should be fixed as soon as possible. But, the complexity of modem machines make the trouble shooting difficult. So, it is important that the monitoring system for automated production system to fix every trobule easily. In this paper new, inverter control system for TG feedback a formula Control was developed. The motor control system with TG feedback controller as an effect of load disturbance, it is very difficult to guarantee the robustness of Control System. The function of the implementation are TG feedback type, and temperature scheme. The Inverter Control System approach is based on master-slave control concept. To show validity of the developed new inverter control system severial experiments are illustrated.

Development of Inverter Control System for Speed Control Punching Machine (펀칭머신의 속도제어를 위한 인버터 제어기 개발)

  • Cho, Hyun-Seob;Ryu, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.628-631
    • /
    • 2008
  • A company needs to maintain its machines always workable in order to keep the manufacturing time minimal. If any troubles occur, they should be fixed as soon as possible. But, the complexity of modern machines make the trouble shooting difficult. So, it is important that the monitoring system for automated production system to fix every trobule easily. In this paper new, inverter control system for TG feedback a formula Control was developed. The motor control system with TG feedback controller as an effect of load disturbance, it is very difficult to guarantee the robustness of control system. The function of the implementation are 7G feedback type, and temperature scheme. The Inverter Control System approach is based on master-slave control concept. To show validity of the developed new inverter control system, severial experiments are illustrated.

Low Complexity Linear Receiver Implementation of SOQPSK-TG Signal Using the Cross-correlated Trellis-Coded Quadrature Modulation(XTCQM) Technique (SOQPSK-TG 신호의 교차상관 격자부호화 직교변조(XTCQM) 기법을 사용한 저복잡도 선형 수신기 구현)

  • Kim, KyunHoi;Eun, Changsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.3
    • /
    • pp.193-201
    • /
    • 2022
  • SOQPSK-TG is a modulated signal for aircraft telemetry with excellent frequency efficiency and power efficiency. In this paper, the phase waveform of the partial response SOQPSK-TG modulation is linearly approximated and modeled as a full response double duobinary SOQPSK (SOQPSK-DD) signal. And using the XTCQM method and the Laurent decomposition method, the SOQPSK-DD signal was approximated as OQPSK having linear pulse waveforms, and the results of the two methods were proved to be the same. In addition, it was confirmed that the Laurent decomposition waveform of the SOQPSK-DD signal approximates the Laurent decomposition waveform of the original SOQPSK-TG signal. And it was shown that the decision feedback IQ-detector, which applied the Laurent decomposition waveform of SOQPSK-DD to the detection filter, exhibits almost the same performance even with a simpler waveform than before.

Development of high tryptophan GM rice and its transcriptome analysis (고 함량 트립토판 생산 GM 벼 개발 및 전사체 분석)

  • Jung, Yu Jin;Nogoy, Franz Marielle;Cho, Yong-Gu;Kang, Kwon Kyoo
    • Journal of Plant Biotechnology
    • /
    • v.42 no.3
    • /
    • pp.186-195
    • /
    • 2015
  • Anthranilate synthase (AS) is a key enzyme in the biosynthesis of tryptophan (Trp), which is the precursor of bioactive metabolites like indole-3-acetic acid and other indole alkaloids. Alpha anthranilate synthase 2 (OsASA2) plays a critical role in the feedback inhibition of tryptophan biosynthesis. In this study, two vectors with single (F124V) and double (S126F/L530D) point mutations of the OsASA2 gene for feedback-insensitive ${\alpha}$ subunit of rice anthranilate synthase were constructed and transformed into wildtype Dongjinbyeo by Agrobacterium-mediated transformation. Transgenic single and double mutant lines were selected as a single copy using TaqMan PCR utilized nos gene probe. To select intergenic lines, the flanking sequence of RB or LB was digested with a BfaI enzyme. Four intergenic lines were selected using a flanking sequence tagged (FST) analysis. Expression in rice (Oryza sativa L.) of the transgenes resulted in the accumulation of tryptophan (Trp), indole-3-acetonitrile (IAN), and indole-3-acetic acid (IAA) in leaves and tryptophan content as a free amino acid in seeds also increased up to 30 times relative to the wildtype. Two homozygous event lines, S-TG1 and D-TG1, were selected for characterization of agronomic traits and metabolite profiling of seeds. Differentially expressed genes (DEGs), related to ion transfer and nutrient supply, were upregulated and DEGs related to co-enzymes that work as functional genes were down regulated. These results suggest that two homozygous event lines may prove effective for the breeding of crops with an increased level of free tryptophan content.

Caspase-8 Potentiates Triglyceride (TG)-Induced Cell Death of THP-1 Macrophages via a Positive Feedback Loop (Caspase-8의 양성 피드백 방식을 통한 중성지방-유도 THP-1 대식세포 사멸 증가)

  • Jung, Byung Chul;Lim, Jaewon;Kim, Sung Hoon;Kim, Yoon Suk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.2
    • /
    • pp.158-164
    • /
    • 2021
  • Hypertriglyceridemia is the main risk factor for atherosclerosis. It is reported that triglyceride (TG) induces macrophage cell death, and is involved in the formation of plaques and development of atherosclerosis. We previously reported that TG-induced cell death of macrophages is mediated via pannexin-1 activation, which increases the extracellular ATP and subsequent increase in potassium efflux, thereby activating the caspase-2/caspase-1/apoptotic caspases, including the caspase-8 pathway. Contrarily, some studies have reported that caspase-8 is an upstream molecule of caspase-1 and caspase-2 in several cellular processes. Therefore, this study was undertaken to investigate whether caspase-8 influences its upstream molecules in TG-stimulated macrophage cell death. We first confirmed that caspase-8 induces caspase-3 activation and poly ADP-ribose polymerase (PARP) cleavage in TG-treated macrophages. Next, we determined that the inhibition of caspase-8 results in reduced caspase-1 and -2 activity, which are upstream molecules of caspase-8 in TG-induced cell death of macrophages. We also found that ATP treatment restores the caspase-8 inhibitor-induced caspase-2 activity, thereby implying that caspase-8 affects the upstream molecules responsible for increasing the extracellular ATP levels in TG-induced macrophage cell death. Taken together, these findings indicate that caspase-8 potentiates the TG-induced macrophage cell death by activating its upstream molecules.