• Title/Summary/Keyword: TEMPERATURE CONDITION

Search Result 11,268, Processing Time 0.033 seconds

Forming Condition for Automotive Body Outer Panel using Aluminum Alloy Sheet for Improved Dent Resistance (차체 외판 부품의 덴트 특성 향상을 위한 알루미늄 판재의 성형조건에 관한 연구)

  • Ko, S.J.;Kim, T.J.;Kim, I.S.
    • Transactions of Materials Processing
    • /
    • v.20 no.6
    • /
    • pp.420-426
    • /
    • 2011
  • Dent resistance is determined by both shape characteristics, i.e., local radius of curvature and sheet thickness, and material properties such as yield strength. This work presents results of a study on the effect of work hardening and bake hardening on dent resistance of aluminum alloy sheet parts by considering the forming condition and baking temperature.

An Experimental Study on the Performance of Fin-Tube Heat Exchanger under Frosting Condition (착상조건하에서 핀-관 열교환기 성능에 관한 실험적 연구)

  • Lee, K.S.;Pak, H.Y.;Lee, T.H.;Lee, N.G.;Lee, S.Y.;Lee, M.R.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.319-328
    • /
    • 1995
  • In this study, the experiment with 2rows-2columns fin-tube heat exchanger under forced convection and frosting condition is performed. The influence of each operating condition(the temperature of air, the humidity of air, the velocity of air, the temperature of coolant) on the growth of frost layer, air-side pressure drop, and characteristics of heat transfer is investigated. The experimental results show that the frost thickness increases rapidly in the early stage of frost formation and increases linearly after sometime. The frost thickness increases with the increase of the inlet air humidity and velocity and the decrease of inlet air temperature and coolant temperature. It is also found that the total energy transfer rate increases with the increase of inlet air temperature and velocity and with the decrease of inlet air humidity and coolant temperature.

  • PDF

On the Distribution of Water Temperature in the Warm Water Pool. -On the Wudu Warm Water Pool- (온수지에서의 수온분포에 관한 연구 -우두온수지를 중심으로-)

  • 연규석;최예환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.3
    • /
    • pp.121-126
    • /
    • 1979
  • The objective of this study was to grasp the condition of the distribution of water temperature in the warm water pool, and these observations were performed in Wudu warm water pool located at Wodu-Dong in Chuncheon. The results summarized in this study are as follows; 1. The horizontal distribution charts of water temperature at each depth of points were shown as Fig. 3, Fig. 4, and Fig. 5, respectively. In consequence of the observation, the condition of warm water was stagnant in the coner of warm water pool. As the result, it was found out that stagnant condition was the heaviest at water surface (depth; 0.05m), more heavier at middle depth (depth; 0.55m) and some heavy at bottom of the pool (depth; 1.10m). 2. The vertical water temperature change was shown as Fig. 6, and the mean water temperature of water surface (depth;0.05m) was higher about $2.2{\sim}3.3^{\circ}C$ than bottom water temperature. 3. Therefore, it was required to device such structures as form of broad cannels or overflow diversion weirs to mingle with top and bottom water.

  • PDF

Comparison Study of Air Temperature by Green Condition and Relative Humidity (녹지 조건에 따른 기온 및 상대습도의 비교연구)

  • 윤용한
    • Asian Journal of Turfgrass Science
    • /
    • v.15 no.3
    • /
    • pp.111-118
    • /
    • 2001
  • We observed air temperature and relative humidity in the green space why this research graspes effect of climate relax by coverage condition and height difference tree in green space of the 4ha scale. With this data, analyzed relationship of coverage and air temperature or relative humidity distribution, number of tree and climate relax by revolution analysis. In this result, higher zone formed barren area, lower zone did forest and surround grassland. Relative humidity have corresponding type of air temperature distribution. higher air temperature zone was lower humidity and lower zone was higher humidity. Coverage condition effect climate relax by increasing forest and grassland. and increasing number of tree effect climate relax no related hight of tree. This efficiency order of an arbor, subarbor.

  • PDF

Effects of UV light irradiation condition and imidization temperature for the generation of pretilt angle on polyimide surfaces (폴리이미드 표면에서의 프리틸트각 발생에 대한 UV조사 조건과 이미드화온도의 영향)

  • Yu, Mun-Sang;Seo, Dae-Shik;Hwang, Jeoung-Yeon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.61-64
    • /
    • 1998
  • We have investigated the effects of ultraviolet (UV) light irradiation condition and imidization temperature for the generation of pretilt angle in nematic liquid crystal (NLC) on the two kinds of the polyimide (PI) surfaces. High pretilt angle of NLC is generated with oblique p-polarized UV light irradiation of 30$^{\circ}$ on PI surface for 20 min. Also, the high pretilt angle of NLC is generated with oblique p-polarized UV light irradiation of 10-30$^{\circ}$ on PI surface at 20min. The pretilt angle of NLC decreases with increasing the imidization temperature on all rubbed PI surfaces ; the pretilt angle of NLC with oblique p-polarized UV light irradiation of 30$^{\circ}$on PI surface decreases with increasing the imidization temperature. The high pretilt angle of NLC is observed due to high photo-depolymerization reaction by low surface energy at low imidization temperature. We suggest that the pretilt angle of NLC is strongly attributed to the photo-depolymerization reaction with the UV light irradiation condition and imidization temperature.

  • PDF

The Low NOx Characteristics of the Primary Zone in Micro Turbine Combustor (마이크로 터빈 연소기 주연소영역의 저 NOx 생성 특성)

  • Son, M.G.;Ahn, K.Y.;Lee, H.S.;Yoon, J.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.155-160
    • /
    • 2001
  • The low NOx characteristics have been investigated to develop the combustor for micro turbine. The lean premixed combustion technology was applied to reduce the NOx emission. The test was conducted at the condition of high temperature and ambient pressure. The combustion air which has the temperature of $450\sim650K$ were supplied to the combustor through the air preheater. The temperature and emissions of NOx and CO were measured at the exit of combustor, The exit temperature and NOx were increased and CO was decreased with increasing inlet air temperature. The premixing chamber can be operated very lean condition of equivalence ratio around 0.35. The NOx was decreased with decreasing the equivalence ratio. The CO was decreased with decreasing the equivalence ratio, but the CO was increased with decreasing the equivalence ratio below 0.4. But, at the very lean condition of equivalence ratio below 0.35 both NOx and CO were increased because of the flame unstability. The NOx was decreased and CO was increased with increasing inlet air flowrate. This results can be used to determine the size of combustor. Consequently the performance of combustor shows the possibility of the application to the gas turbine system.

  • PDF

Dimensional Responses of Wood Under Cyclical Changing Temperature at Constant Relative Humidity

  • Yang, Tiantian;Ma, Erni;Shi, Yi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.539-547
    • /
    • 2015
  • To investigate dimensional responses of wood under dynamic temperature condition, poplar (populous euramericana Cv.) specimens, 20 mm in radial (R) and tangential (T) directions with two thicknesses of 4 and 10 mm along the grain, were exposed to cyclic temperature changes in square wave between $25^{\circ}C$ and $40^{\circ}C$ at 60% relative humidity (RH) for three different cycling periods of 6 h, 12 h and 24 h. R and T dimensional changes measured during the cycling gave the following results: 1) Transverse dimensional changes of the specimens were generally square but at an opposite phase and lagged behind the imposed temperature changes. The phase lag was inversely correlated with cycling period, but positively related to specimen thickness, while the response amplitude was directly proportional to cycling period, but in a negative correlation with specimen thickness. 2) The specimens showed swelling hysteresis behavior. The heat shrinkage coefficient (HSC) became greater as cycling period increased or specimen thickness decreased. 3) Dimensional changes of the specimens produced deformation accumulation during repeated adsorption and desorption. The deformation accumulating ratio decreased with an increase in cycling period and specimen thickness. 4) Wood suffered 1.5 times as many dimensional changes per unit temperature variation as per unit humidity variation, and this deformation behaved even more seriously under static condition.

A Study on the Three-Dimensional Steady State Temperature Distributions and BOR Calculation Program Development for the Membrane Type LNG Carrier (Membrane Type LNG선의 3차원 정상상태 온도분포 및 BOR 계산 프로그램 개발에 관한 연구)

  • 이정혜
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.140-149
    • /
    • 1999
  • This study is on the development of the computer program that calculates a 3-D hull temperadistribution and analyzes BOR(Boil off rate) to be important to the heat design of a membrane type LNG carrier. The quarter of a tank is taken as an calculation model. And the thermal conductivity of insulation is assumed to be the function of a temperature. In the present steady state calculation, the temperature of LNG in a cargo tank is assumed to be -$162^{\circ}C$ and the air temperature of a cofferdam, to be +$5^{\circ}C$. The lowest air temperature in compartments is calculated as $21.39^{\circ}C$ under the USCG condition ($T_{air}=-18^{\circ}C,\;T_{sw}=O^{\circ}C)$ and B.O.R value is O.0977%/day under the maximum boil-off condition, IMO IGC ($T_{air}=45^{\circ}C,\;T_{sw}=32^{\circ}C$), which satisfies the requirement by KOGAS. The calculated temperature distribution over tank panels at each condition is maximum 3% less than GTT's results. From the results of this study, it can be concluded that the present design of LNG cargo tank satisfies the requirement by KOGAS.

  • PDF

Behavior and Performance Evaluation of a Concrete Pavement Considering the Temperature Condition in a Tunnel (터널내 온도조건을 고려한 콘크리트 포장의 거동 및 성능 평가)

  • Ryu, Sung Woo;Park, JunYoung;Kim, HyungBae;Lee, Jaehoon;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.18 no.2
    • /
    • pp.11-18
    • /
    • 2016
  • PURPOSES: This paper investigates behavior and performance of concrete pavement in tunnel based on temperature data from field. METHODS : In this study, there are 4 contents to evaluate concrete pavement in tunnel, First, Comparison for distress was conducted at outside, transition, and inside part of tunnel. Secondly, temperature data was collected in air and inside concrete pavement in outside and inside tunnel. Thirdly, FEM analysis was performed to evaluate stress condition, based on temperature data from field. Finally, performance prediction was done with KPRP program. RESULTS: From the distress evaluation, failure of inside tunnel was much less than it of outside tunnel, Temperature change in tunnel was less than out side, and also it was more stable. According to result of FEM analysis, both curling stress status of inside tunnel was lower than it of outside tunnel. Based on KPRP program analysis, performance of inside tunnel was longer than outside. CONCLUSIONS : Through all study about behavior and performance of concrete pavement in tunnel, condition in tunnel has more advantages from environmental and distress point of view. Therefore, performance of inside tunnel was better than outside.

Reducing Exhaust Hydrocarbon at Gasoline Engine with Catalytic Converter using Synchronized Secondary Air Injection (촉매가 장착된 가솔린엔진에서 동기화된 2차공기분사에 의한 배기 탄화수소 저감)

  • 심현성;민경덕;정석호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.67-74
    • /
    • 2001
  • A synchronized secondaty air injection method has been developed to hydrocarbon emission by injecting secondary air intermittently into exhaust port. The method has been tested in a single cylinder spark-ignition engine operating at cold-steady / cold-start conditions. Effects of air injection timing, intake pressure and engine air-fuel ratio have been investigated at cold-steady condition. Also, hydrocarbon emission and exhaust gas temperature with catalytic conberter are compared with a continuous SAI method and base condition at cold-start condition. Resules show that hydrocarbon reduction rate and exhaust gas temperature are sensitive to the timing of synchronized SAI. At cold-steady condition, HC emission is minimum at engine air-fuel ratio of 10. At cold-start condition, the accumulated hydrocarbon emission during the first 120 s decreases about 56% and 22% with the synchronized and continuous SAI, respectively, compared to that of base condition.

  • PDF