• Title/Summary/Keyword: TEM.

Search Result 3,872, Processing Time 0.028 seconds

Three-dimensional Finite Difference Modeling of Time-domain Electromagnetic Method Using Staggered Grid (엇갈린 격자를 이용한 3차원 유한차분 시간영역 전자탐사 모델링)

  • Jang, Hangilro;Nam, Myung Jin;Cho, Sung Oh;Kim, Hee Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.3
    • /
    • pp.121-128
    • /
    • 2017
  • Interpretation of time-domain electromagnetic (TEM) data has been made mostly based on one-dimensional (1-D) inversion scheme in Korea. A proper interpretation of TEM data should employ 3-D TEM forward and inverse modeling algorithms. This study developed a 3-D TEM modeling algorithm using a finite difference time-domain (FDTD) method with staggered grid. In numerically solving Maxwell equations, fictitious displacement current is included based on an explicit FDTD method using a central difference approximation scheme. The developed modeling algorithm simulated a small-coil source configuration to be verified against analytic solutions for homogeneous half-space models. Further, TEM responses for a 3-D anomaly are modeled and analyzed. We expect that it will contribute greatly to the precise interpretation of TEM data.

TemG : A Geofence Platform with Time-Limited Property (TemG : 시한적 속성을 갖고 있는 지오펜스 플랫폼)

  • Eom, Young-Hyun;Choi, Young-Keun;Cho, Sungkuk;Jeon, Byungkook
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.177-182
    • /
    • 2016
  • Geofence is a generic concept for describing geographic aspects of PoI(Point of Interest) enabling users to proactively induce context-based actions. However there is no need to maintain continuity when you reflect geofence in case of temporary events, accidents and isolation. Therefore we propose a geofence platform so-called TemG by adding time-limited information to support PoI. The proposed geofence platform TemG ensures the persistency and continuity of geofence. Furthermore, the proposed TemG can not only provide to automatically activate or deactivate the specified geofence during a period of timestamp but also support to the basic context-aware service knowing in/out in the zone. In the near future, the proposed TemG will be need to extend HPS(Hybrid Positioning System) for IoT(Internet of Things).

Prevalence of Strains Resistant to the Third Generation Cephalosporins among Clinical Isolates and Identification of TEM Type $\beta$-lactamase from Resistant Strains by PCR Method (3 세대 세파계 항생제에 내성인 임상균주의 분포와 PCR 법을 이용한 TEM type $\beta$-lactamase 생산균주의 동정)

  • 김무용;오정인;송혜경;백경숙;곽진환
    • YAKHAK HOEJI
    • /
    • v.39 no.3
    • /
    • pp.276-282
    • /
    • 1995
  • Compared to the first and second-generation cephalosporins, the third-generation cephalosporins are remarkably stable against hydrolysis by the $\beta$-lactamases produced by aerobic gram-negative bacilli, such as Enterobacteriaceae. Among these bacteria, the most prevalent plasmid-encoded $\beta$-lactamase is TEM-1 $\beta$-lactamase belonging to class A or group 2b. This enzyme is produced constitutively and is principally active against peniciflins and old cephalosporins rather than third-generafion cephalosporins, carbapenems and mmobactams. However, new TEM type $\beta$-lactamases including TEM-9 and TEM-12 evolved through point mutations in a gene encoding $\beta$-lactamase have been discovered from patients during chemotherapy. These $\beta$-lactamases are known to be capable of hydrolyzing most of the third-generatim cephalosporins. To study the prevalence of $\beta$-lactamases from clinical isolates collected in Korea. the minimal inhibitory concentratims(MICs) of several third-generation cephalosporins against 628 clinical isolates were determined by agar dilution methods, and $\beta$-lactamas-producing bacteria were isolated by use of cefinase disc. By polymerase chain reaction (PCR) method, clinical isolates harboring a gene for TEM type $\beta$-lactamase were identified among the $\beta$-lactamase producing strains. Twentiy three percent of the clinical isolates was resistant to the thirdgeneration cephalosporins, and more than 90% of resistant cells produced various $\beta$-lactamases. TFM type $\beta$-lactamases were dominant in gram-negative bacilli, such as Escherichia coli, Klebsiella pneumoniae, Enterobacter species. These results suggest the necessity of the development of new cephalosporins which are stable against $\beta$-lactamases like TEM.

  • PDF

Design of TE10 to TEM mode convertor for W-band radial power combiner (W밴드 radial 전력 결합기용 TE10-TEM 모드 변환기 설계)

  • Young-Gon Kim;Myung-Hun Yong;Han-Chun Ryu;Se-Hoon Kwon;Seon-Keol Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.41-46
    • /
    • 2023
  • Design of W-band TE10 to TEM mode converter for radial power combiner is proposed in this paper. The proposed structure is used with generally available pin to realize TEM mode and is designed to convert TE10 to TEM mode gradually using 2-step impedance transformer and back short. The pin of proposed mode converter is well bonded to the housing so that environment conditions such as vibration or shock are not affected. The proposed mode converter, in a back-to-back configuration, has less than 1.55 dB insertion loss and more than 10 dB return loss from 92.5 GHz to 97.7 GHz. Proposed converter is expected compact radar and various applications requiring for high power and stable environment conditions.

Development of Multi-sample Loading Device for TEM Characterization of Hydroxyapatite Nanopowder

  • Lee, Jong-Moon;Kim, Jung-Kyun;Jeong, Jong-Man;Kim, Jin-Gyu;Lee, Eunji;Kim, Youn-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.788-792
    • /
    • 2013
  • A shortcoming of using transmission electron microscopy (TEM) for structural analysis via electron diffraction is the relatively large error of the measurements as compared to X-ray diffraction. To reduce these errors, various internal standard methods from earlier studies have been widely used. We developed a new device to facilitate the application of internal standard methods in preparation of TEM grids used for nanopowder analysis. Through the application of a partial mask on the TEM grid, both the internal standards and the research materials can be loaded on the same grid. Through this process, we conducted a TEM analysis that compared synthetic hydroxyapatite (HAp) nanopowder to bone apatite from a bovine femur. We determined that the accuracy of the d-spacing measurements of the HAp and bone powders could be improved to better than 1% after statistical treatments of the experimental data. By applying a quarter mask, we loaded four different nanoparticles on a single TEM grid, with one section designated for the internal standard.

Development of TEM Coil for Animal Experiments at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.365-366
    • /
    • 2002
  • A novel TEM resonator coil was developed for the imaging of small animals. The functional elements of the TEM resonator were 8 inner conductors, distributed in a cylindrical pattern and connected at the ends with capacitors to the cylindrical outer shield. The TEM resonator coil with cavity elements was robust to the surrounding influences due to the self-shielding structure. The TEM resonator coil with high Q factor could provide high quality MR images at 3.0T MRI system. Also, the TEM resonator coil has an advantage for a fine tune with length adjustment of each cavity elements. Thus, The TEM resonator coil at 3.0T, even higher field could be used in the research studies.

  • PDF

Effects of PCB Patterns on EMI Measurement in TEM Cell and Proposal of PCB Design Guidelines (TEM 셀에서 PCB 패턴이 EMI 측정에 미치는 영향 및 PCB 설계 가이드라인 제시)

  • Choi, Minkyoung;Shin, Youngsan;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.272-275
    • /
    • 2017
  • Recently, semiconductor integration density enormously increases and its interconnection width is significantly narrowed, which leads to EMI (electromagnetic interference) problems on chip level. Chip manufacturer exploits TEM cell (transverse electromagnetic cell) to measure EMI on chip level, which requires PCB (printed circuit board) for measurement purpose. However, it is often neglected to consider that PCB patterns and other factors can affect on EMI measurement. In this paper, several test patterns are designed for different PCB design variables, and effects of PCB patterns on EMI measurement in TEM cell are analyzed. Based on these analyses, PCB design guidelines are also proposed to minimize the effects on EMI measurements.

Transmission Electron Microscope Specimen Preparation of Si-Based Anode Materials for Li-Ion Battery by Using Focused Ion Beam and Ultramicrotome

  • Chae, Jeong Eun;Yang, Jun Mo;Kim, Sung Soo;Park, Ju Cheol
    • Applied Microscopy
    • /
    • v.48 no.2
    • /
    • pp.49-53
    • /
    • 2018
  • A successful transmission electron microscope (TEM) analysis is closely related to the preparation of the TEM specimen and should be followed by the suitable TEM specimen preparation depending on the purpose of analysis and the subject materials. In the case of the Si-based anode material, lithium atoms of formed Li silicide were removed due to ion beam and electron beam during TEM specimen preparation and TEM observation. To overcome the problem, we proposed a new technique to make a TEM specimen without the ion beam damage. In this study, two types of test specimens from the Si-based anode material of Li-ion battery were prepared by respectively adopting the only focused ion beam (FIB) method and the new FIB-ultramicrotome method. TEM analyses of two samples were conducted to compare the Ga ion damage of the test specimen.

Analysis of Aircraft Upset through TEM and Improvement of UPRT (항공기 비정상 자세 사고의 TEM 분류 및 UPRT 향상에 관한 연구)

  • Choi, Jin-Kook;Jeon, Seung-Joon
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.11
    • /
    • pp.365-374
    • /
    • 2019
  • Loss of Control in Flight(LOC-I) due to aircraft upset attitude has the highest air accident rate, and International Aviation Institute such as ICAO and FAA recommended flight crew to operate aircraft safely through UPRT(Upset Prevention & Recovery Training) program. ICAO has selected Loss of Control(LOC) as key safety indicator, and recommended to respond using TEM(Threat and Error Management). However there are not much specific treats and errors classified for UPRT programs using real TEM based on evidences. This study intends to consider the importance of UPRT through the introduction of UPRT and accident analysis using TEM. Typical upset accidents were classified to common threats as IFR, inadequate training, Automation surprise, and inexperienced copilots. The common errors were cross-check, speed and altitude deviation, callouts, communication, thrust and stall action fail. The undesired aircraft states were inadequate automation mode, Deviation of speed and vertical, stall, and crash. These suggest areas to improve UPRT.

반도체 소자의 투과 전자 현미경(TEM) 관찰을 위한 단면 시료 제작 기술

  • Cha, Ju-Yeon;Gwon, O-Jun;Lee, Jin-Hyo
    • ETRI Journal
    • /
    • v.11 no.3
    • /
    • pp.65-72
    • /
    • 1989
  • 투과 전자 현미경 (Transmission Electron Microscope : TEM))의 단면 시료 관찰은 반도체 소자의 미세화에 따른 공정 평가, failure analysis 분야에 최근 많이 사용되고 있으나 TEM관찰을 위한 반도체 소자의 시료 제작 기술이 반도체 재료의 특성상 매우 어렵기 때문에 만족할만한 연구 성과가 미흡한 실정이다. 여기에서는 확산 공정 기술 개발에 따른 시료의 TEM 관찰에 필요한 단면 관찰용 시료 제작 기술에 대한 연구 결과를 정리 하였다.

  • PDF