• Title/Summary/Keyword: TELEMETRY

Search Result 552, Processing Time 0.024 seconds

Analysis of Data Transmission Rate and Power Consumption in Zigbee Based Electrocardiography (지그비 기반 심전계의 데이터 전송률과 소비 전력 분석)

  • Kim, Nam-Jin;Hong, Joo-Hyun;Lee, Tae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.12
    • /
    • pp.96-104
    • /
    • 2006
  • In this study, data transmission ratio and power consumption issues of Zigbee based sensor module and personal digital assistant(PDA) were addressed to develop ECG telemetry device. PDA processes the data transmitted through serial port using non-blocking method. The transmission rate was dependent on the packet structure. It was 300 ECG samples/sec, when each packet was composed of 2 ECG data and 3-axial acceleration vector. Using two AAA batteries in series, operating time of the wireless sensor module was above 28 hours in average. Power consumption of PDA was dependent on screen ON/OFF condition and serial port usage. In this application, operating time of PDA was 5 hours in average. In conclusion, there was no problem in the power consumption of wireless sensor module and transmission rate, when the developed device was used as 24 hour Holter device. But, PDA has the problem of power consumption, which should be solved.

  • PDF

Torque Measurement of Rotating Shaft Using Fiber Bragg Grating Sensors and Rotary Optical Coupler (광섬유격자센서와 회전광학커플러를 사용한 새로운 회전축의 토크 측정방법)

  • Lee, Jong-Min;Hwang, Yo-Ha
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1195-1200
    • /
    • 2007
  • Torque of a rotating shaft has been mostly measured by strain gages combined with either a slip ring or telemetry. However, these methods have severe inherent problems like low S/N ratio, high cost, limited number of channels and difficult installation. In this paper, a new method using FBG(fiber bragg grating) sensors and a rotary optical coupler for online non-contact torque monitoring is suggested. FBG sensor can measure both strain and temperature, and has much batter characteristics than those of a strain gage. A rotary optical coupler is a optical connecting device between a rotating shaft and stationary side without any physical contact. It has been devised for transmitting light between a rotating optical fiber and a stationary optical fiber. The proposed method uses this rotary optical coupler to connect FBG sensors on the rotating shaft to instruments at stationary side. And a reference FBG sensor is also applied to compensate the insertion loss change of the rotary optical coupler due to rotation. Three FBG sensors have been fabricated in a single optical fiber. Two FBG sensors are attached on the shaft surface to measure torque and one sensor is installed at the shaft center to compensate the insertion loss change. The torque of a rotating shaft has been successfully measured by the suggested method proving its superior performance potential.

Manufature of Telemetry System for Multiple Subjects Using CMOS Custom IC (전용 CMOS IC에 의한 다중 생체 텔레미트리 시스템 제작)

  • Choi, Se-Gon;Seo, Hee-Don;Park, Jong-Dae;Kim, Jae-Mun
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.43-50
    • /
    • 1996
  • This paper presents a manufacture of the multiple subjects biotelemetry system using custom CMOS IC fabricated $1.5{\mu}m$ n-well process technology. The implantable circuits of the system except sensor interface circuits including FM transmitter are fabricated on a single chip with the sire of $4{\times}4mm^{2}$. It is possible to assemble the implantable system in a hybrid package as small as $3{\times}3{\times}2.5cm$ by using this chip, It's main function is to enable continuous measurement simultaneously up to 7-channel physiological signals from the selected one among 8 subjects. Another features of this system are to enable continuous measurement of physiological signals, and to accomplish ON/OFF switching of an implanted battery by subject selection signal with command signal from the external circuit. If this system is coupled with another appropriate sensors in medical field, various physiological parameters such as pressure, pH and temperature are to be measured effectively in the near future.

  • PDF

Analysis of DIC Platform and Image Quality with FHD for Displacement Measurement (FHD급 DIC 플랫폼의 변위계측용 영상품질 분석)

  • Park, Jongbae;Kang, Mingoo
    • Journal of Internet Computing and Services
    • /
    • v.19 no.1
    • /
    • pp.105-111
    • /
    • 2018
  • This paper presents the analysis of image quality with FHD(Full HD) resolution camera equipped DIC(Digital Image Correlation) platform for the measurement of the architectural structure's relative displacement. DIC platform was designed based on i.MX6 of Freescale. Displacement measurement based on DIC method, the error is affected by image quality factors as pixel number, brightness, contrast, and SNR[dB](Signal to Noise Ratio). The effect were analyzed. The displacement of ROI(Region Of Interest) area within the image was measured by sub-pixel units based on DIC method. The non-contact telemetry property of DIC method, it can be used to long distance non-contact measurement. The various displacement results was measured and analyzed with the image quality factor adjustment according to the distance(25m, 35m, 50m).

Telecommand Decryption Verification for Engineering Qualification Model of Command Telemetry Unit in Communications Satellite (통신위성 원격측정명령처리기 성능검증모델 원격명령 암호복호 검증)

  • Kim, Joong-Pyo;Koo, Cheol-Hea
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.7
    • /
    • pp.98-105
    • /
    • 2005
  • In this paper, the decryption function of CCSDS telecommand of CTU EQM for the security of communications satellite was verified. In order to intensify the security level of DES CFB decryption algorithm applied to CTU EM, 3DES CFB decryption algorithm using three keys is implemented in the CTU EQM. As the decryption keys increased due to the 3DES algorithm, the keys and IV are stored in PROM memory, and used for the telecommand decryption by taking the keys and IVs corresponding to the selected key and IV indexes from the memory. The operation of the 3DES CFB is validated through the timing simulation of 3DES CFB algorithm, and then the 3DES CFB core implemented on the A54SX32 FPGA. The test environment for the telecommand decryption verification of the CTU EQM was built up. Through sending and decrypting the encrypted command, monitoring the opcodes, and confirming LED on/off by executing the opcodes, the 3DES CFB telecommand decryption function of the CTU EQM is verified.

A Study on the Performance of COMS CPS during LEOP (천리안 위성의 LEOP기간 동안의 추진계 성능 연구)

  • Chae, Jong-Won;Han, Cho-Young;Yu, Myoung-Jong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.258-263
    • /
    • 2012
  • In this paper the Chemical Propulsion Subsystem of COMS is briefly explained and some telemetries acquired by a series operations of CPS during the Launch and Early Operation Phase of COMS are presented. The pressure and temperature of pressurant tank telemetries are compared with the results of the developed computer program. The changes in pressure are due to the two major phases. The first one is the initialization phases of CPS composed of the venting phase to vent the helium gas in the pipe network from the downstream of the propellant tanks to the thrusters for safety, the priming phase to fill the vented pipe network with oxidizer and fuel respectively and then the pressurization phase to pressurize the ullage of propellant tank to regulated pressure. And the other is the apogee engine firings in which COMS CPS is in the orbit raising phase to use helium as a pressurant to keep the pressure of propellant tank as the liquid apogee engine get fired until COMS reached to the target orbit. This program can be applicable to prepare basis design data of the next Geostationary Satellite CPS.

Design, Implementation and Test of Flight Model of X-Band Transmitter for STSAT-3 (과학기술위성 3호 X-대역 송신기 비행모델 설계, 제작 및 시험)

  • Seo, Gyu-Jae;Lee, Jung-Soo;Oh, Chi-Wook;Oh, Seung-Han;Chae, Jang-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.5
    • /
    • pp.461-466
    • /
    • 2012
  • This paper describes the development and test result of X-band Transmitter flight model(FM) of STSAT-3 by satellite research center(SaTReC), KAIST. The communication sub-system of STSAT-3 is consist of two different frequency band channels. S-band frequency is used for Telemetry & Command, and X-band frequency is used for mission data. Payload observations data in Mass Memory Unit (MMU) is modulated by QPSK modulator in X-band Transmitter, and then QPSK modulation signal is transmitted to antenna through transfer switch. In this Paper, we described the results of modulation, low-pass filter design, power amp development, and switch test. The FM XTU is delivered Spacecraft Assembly, Integration and Test(AIT) level through the completion of functional Test and environmental(vibration, thermal vacuum) Test successfully.

Flight trajectory generation through post-processing of launch vehicle tracking data (발사체 추적자료 후처리를 통한 비행궤적 생성)

  • Yun, Sek-Young;Lyou, Joon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.6
    • /
    • pp.53-61
    • /
    • 2014
  • For monitoring the flight trajectory and the status of a launch vehicle, the mission control system in NARO space center process data acquired from the ground tracking system, which consists of two tracking radars, four telemetry stations, and one electro-optical tracking system. Each tracking unit exhibits its own tracking error mainly due to multi-path, clutter and radio refraction, and by utilizing only one among transmitted informations, it is not possible to determine the actual vehicle trajectory. This paper presents a way of generating flight trajectory via post-processing the data received from the ground tracking system. The post-processing algorithm is divided into two parts: compensation for atmosphere radio refraction and multi-sensor fusion, for which a decentralized Kalman filter was adopted and implemented based on constant acceleration model. Applications of the present scheme to real data resulted in the flight trajectory where the tracking errors were minimized than done by any one sensor.

Korea Red Ginseng Alters Electroencephalogram Spectra of Sleep-Wake Stage in Rats

  • Ma, Yuan;Eun, Jae-Soon;Cheong, Jae-Hoon;Rhee, Dong-Kwon;Hong, Jin-Tae;Oh, Ki-Wan
    • Journal of Ginseng Research
    • /
    • v.32 no.3
    • /
    • pp.220-225
    • /
    • 2008
  • The present investigation was performed to evaluate the homeostatic regulation of sleep architecture by the ethanol extract of Korea red ginseng (KRG), since the available data were often controversial. In addition, it was also interested in whether the sleep-wake stages were differently affected by low and high doses of KRG. Each adult Wistar male rat was implanted with a transmitter for recording EEG and activity via telemetry. After one week of surgery, polygraphic signs of undisturbed sleep-wake activities were recorded for 12 h (between 9:00 am and 9:00 pm) after KRG administration. KRG (10 and 100 mg/kg) increased non-rapid eye movement (NREM) sleep as well as total sleep. The total percentages of wakefulness were decreased comparably. KRG (10 mg/kg) decreased the power density of the ${\delta}-wave$ (0.75-4.5 Hz) and increased ${\alpha}-wave$ (8.0-13.0 Hz) in the NREM and rapid eye movement (REM) sleep. KRG also decreased ${\delta}-wave$ power density in wake time. However, KRG (100 mg/kg) increased ${\delta}-wave$ and decreased ${\theta}-wave$ (5.0-9.0 Hz) power density in wake time, while showed little effect on the power density in NREM and REM sleep. In conclusion, low and high doses of KRG increase spontaneous sleep and NREM sleep and differently regulate the EEG spectra in REM and NREM sleep.

A Study on Control of Drone Swarms Using Depth Camera (Depth 카메라를 사용한 군집 드론의 제어에 대한 연구)

  • Lee, Seong-Ho;Kim, Dong-Han;Han, Kyong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1080-1088
    • /
    • 2018
  • General methods of controlling a drone are divided into manual control and automatic control, which means a drone moves along the route. In case of manual control, a man should be able to figure out the location and status of a drone and have a controller to control it remotely. When people control a drone, they collect information about the location and position of a drone with the eyes and have its internal information such as the battery voltage and atmospheric pressure delivered through telemetry. They make a decision about the movement of a drone based on the gathered information and control it with a radio device. The automatic control method of a drone finding its route itself is not much different from manual control by man. The information about the position of a drone is collected with the gyro and accelerator sensor, and the internal information is delivered to the CPU digitally. The location information of a drone is collected with GPS, atmospheric pressure sensors, camera sensors, and ultrasound sensors. This paper presents an investigation into drone control by a remote computer. Instead of using the automatic control function of a drone, this approach involves a computer observing a drone, determining its movement based on the observation results, and controlling it with a radio device. The computer with a Depth camera collects information, makes a decision, and controls a drone in a similar way to human beings, which makes it applicable to various fields. Its usability is enhanced further since it can control common commercial drones instead of specially manufactured drones for swarm flight. It can also be used to prevent drones clashing each other, control access to a drone, and control drones with no permit.