• Title/Summary/Keyword: TC10

Search Result 2,129, Processing Time 0.027 seconds

Dietary Tea Catechin Inclusion Changes Plasma Biochemical Parameters, Hormone Concentrations and Glutathione Redox Status in Goats

  • Zhong, Rongzhen;Xiao, Wenjun;Ren, Guopu;Zhou, Daowei;Tan, Chuanyan;Tan, Zhiliang;Han, Xuefeng;Tang, Shaoxun;Zhou, Chuanshe;Wang, Min
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.12
    • /
    • pp.1681-1689
    • /
    • 2011
  • The beneficial effects of tea catechins (TCs) are related not only to their antioxidant potential but also to the improvement of animal meat quality. In this study, we assessed the effects of dietary TC supplementation on plasma biochemical parameters, hormone responses, and glutathione redox status in goats. Forty Liuyang goats were randomly divided into four equal groups (10 animals/group) that were assigned to four experimental diets with TC supplementation at 4 levels (0, 2,000, 3,000 or 4,000 mg TC/kg DM feed). After a 60-day feeding trial, all goats were slaughtered and sampled. Dietary TC treatment had no significant effect on blood biochemical parameters, however, low-density lipoprotein cholesterol (p<0.001), triglyceride (p<0.01), plasma urea nitrogen (p<0.01), and glucose (p<0.001) decreased and total protein (p<0.01) and albumin (p<0.05) increased with the feeding time extension, and day 20 was the turning point for most of changes. Interactions were found in glutathione (p<0.001) and the ratio of reduced and oxidized glutathione (p<0.05) in whole blood between treatment and feeding time. Oxidized glutathione in blood was reduced (p<0.05) by 2,000 mg TC/kg feed supplementation, and a similar result was observed in longissimus dorsi muscle. Though plasma glutathione peroxidase (p<0.01) and glutathione reductase (p<0.05) activities were affected by treatment and feeding time interactions, and glutathione S-transferases activity increased with feeding day extension, no changed values appeared in longissimus dorsi muscle. In conclusion, dietary TC supplementation affected the concentrations of some blood metabolites and accelerated GSH depletion in the blood of goats. In terms of less high-density lipoprotein cholesterol, the highest insulin and IGF-I concentrations, the highest ratio of reduced and oxidized glutathione in plasma, the dosage of 2,000 mg TC/kg feed might be desirable for growing goats to prevent glutathione depletion and keep normal physiological metabolism.

Characteristics of Tropical Cyclones in 2010 (2010년 태풍 특징)

  • Lim, Myeong Soon;Moon, Il-Ju;Cha, Yu-Mi;Chang, Ki-Ho;Kang, Ki-Ryong;Byun, Kun Young;Shin, Do-Shick;Kim, Ji Young
    • Atmosphere
    • /
    • v.24 no.3
    • /
    • pp.283-301
    • /
    • 2014
  • In 2010, only 14 tropical cyclones (TCs) were generated over the western North Pacific (WNP), which was the smallest since 1951. This study summarizes characteristics of TCs generated in 2010 over the WNP and investigates the causes of the record-breaking TC genesis. A long-term variation of TC activity in the WNP and verification of official track forecast in 2010 are also examined. Monthly tropical sea surface temperature (SST) anomaly data reveal that El Ni$\tilde{n}$o/Southern Oscillation (ENSO) event in 2010 was shifted from El Ni$\tilde{n}$o to La Ni$\tilde{n}$a in June and the La Ni$\tilde{n}$a event was strong and continued to the end of the year. We found that these tropical environments leaded to unfavorable conditions for TC formation at main TC development area prior to May and at tropics east of $140^{\circ}E$ during summer mostly due to low SST, weak convection, and strong vertical wind shear in those areas. The similar ENSO event (in shifting time and La Ni$\tilde{n}$a intensity) also occurred in 1998, which was the second smallest TC genesis year (16 TCs) since 1951. The common point of the two years suggests that the ENSO episode shifting from El Ni$\tilde{n}$o to strong La Ni$\tilde{n}$a in summer leads to extremely low TC genesis during La Ni$\tilde{n}$a although more samples are needed for confidence. In 2010, three TCs, DIANMU (1004), KOMPASU (1007) and MALOU (1009), influenced the Korean Peninsula (KP) in spite of low total TC genesis. These TCs were all generated at high latitude above $20^{\circ}N$ and arrived over the KP in short time. Among them, KOMPASU (1007) brought the most serious damage to the KP due to strong wind. For 14 TCs in 2010, mean official track forecast error of the Korea Meteorological Administration (KMA) for 48 hours was 215 km, which was the highest among other foreign agencies although the errors are generally decreasing for last 10 years, suggesting that more efforts are needed to improve the forecast skill.

Radiological Risk Assessment for $^{99m}Tc$ Generator using Uncertainty Analysis (불확실성 분석을 이용한 $^{99m}Tc$ 발생기 사용의 방사선위험도 평가)

  • Jang, H.K.;Kim, J.Y.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.129-139
    • /
    • 2004
  • Recently, much attentions are paid to the risk associated with increased uses of medium size radiation sources in medical and industrial fields. In this study, radiation risks to the worker and to the general public due to $^{99m}Tc$ generator were assessed for both normal and accident conditions. Based on the event tree technique, exposure scenarios for various situations were derived. Uncertainty analysis based on the Monte-Carlo technique was applied to the risk assessment for workers and members of the public in the vicinity of the work place. In addition, sensitivity analysis was performed on each of the five independent input parameters to identify importance of the parameters with respect to the resulting risk. Because the frequencies of normal tasks are fat higher than those of accidents, the total risk associated with normal tasks were higher than the accident risk. The annual dose due to normal tasks were $0.6mSv\;y^{-1}$ for workers and $0.014mSv\;y^{-1}$ for public, while in accident conditions $3.96mSv\;y^{-1}\;and\;0.0016mSv\;y^{-1}$, respectively. Uncertainty range of accident risk was higher by 10 times than that of normal risk. Sensitivity analysis revealed that source strength, working distance and working time were crucial factors affecting risk. This risk analysis methodology and its results will contribute to establishment of risk-informed regulation for medium and large radioactive sources.

The Diagnostic Value of 99mTc DMSA Renal Scan SPECT Images in Addition to Planar Image in Children with Urinary Tract Infection (소아 요로 감염에서 99mTc DMSA 신스캔 평면영상에 추가된 SPECT 영상의 진단적 가치)

  • Yang Jea-Young;Yang Jung-An;Seo Jung-Wan;Lee Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.5 no.1
    • /
    • pp.22-29
    • /
    • 2001
  • Purpose : 99mTc DMSA renal scan have been widely used not only for tile evaluation of renal scars but also for the diagnosis of acute pyelonephritis. Recent studies have shown SPECT images have higher accuracy than the planar images with some controversy. We evaluated the availability of the SPECT images adding to planar images for the diagnosis of acute pyelonephritis(APN) and renal scar in children with urinary tract infection (UTI). Methods : 130 children with UTI (260 kidney units) and 22 follow-up children (44 kidney units) were included between January 1, 1997 and July 31, 1999 at Ewha University Mokdong Hospital. Planar Anterior and posterior images and SPECT axial and coronal images of 99mTc DMSA renal scan were obtained with Starcam 4000-i U.S.A. GE at 3 hours after 99mTc DMSA I.V. injection. The data were analyzed by Chi square test after Yates's correction. Results : The detection rate of the acute pyelonephritis by SPECT images was 12.3$\%$ higher than that of planar images ($47.7\%\;vs\;35.4\%$) by the patient and 6.9$\%$ higher also ($31.9\%\;vs\;25.4\%$) by the kidney unit. 18 kidney units with negative planar images had focal defect in 10 kidney units (3.8$\%$) and multifocal defect in 8 kidney units (3.1$\%$) on SPECT images, but 1 kidney unit with positive planar image had negative SPECT image. SPECT images were superior to tile planar images in 17.3$\%$. identical in 82.3$\%$ and inferior in 0.4$\%$ to planar image. The detection rate of tile renal scars by SPECT images was 13.7$\%$ higher than planar images by the patient ($68.2\%\;vs\;54.5\%$) and 6.8$\%$ higher also ($43.2\%\;vs\;36.4\%$) by the kidney unit. SPECT images were superior to the planar images in 17.3$\%$ and identical in 82.3$\%$ to planar image. Conclusion SPECT images had shown higher detection rate and better image than planar images for the diagnosis of the acute pyelonephritis and the evaluation of the renal scars. (J. Korean Soc Pediatr Nephrol 5 : 22- 9, 2001)

  • PDF

The Usefulness of Mammography and Scintimammography in Differential Diagnosis of Breast Tumor (유방 종괴에서 악성 감별을 위한 유방촬영술과 유방스캔의 유용성 연구)

  • Kang, Bong-Joo;Chung, Young-An;Jung, Hyun-Seok;Jung, Jung-Im;Yoo, Ie-Ryung;Kim, Sung-Hoon;Sohn, Hyung-Sun;Chung, Soo-Kyo;Hahn, Seong-Tai;Lee, Jae-Mun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.492-497
    • /
    • 2004
  • Purpose: it is very important to differentiate breast cancer from benign mass. There are many reports to evaluate the differential diagnosis under the several diagnostic tools. We evaluated the usefulness of mammography and Tc-99m MIBI scintimammography in the differential diagnosis of breast mass and correlated with pathologic findings. Materials and Methods: This study included 80 patients (a8e: 24-72, mean: 48.4) who underwent mammography and Tc-99m MIBI scintimammography for breast masses. Scintimammographies (anterior-posterior and lateral projections) were acquired in 10 minutes and 2 hours after intravenous injection of Tc-99m MIBI. four specialists in diagnostic radioloay and nuclear medicine evaluated the findings of breast masses under the mammography and Tc-99m MIBI scintimammography, and calculated the tumor to background (T/B) ratio. The pathologic results were obtained and we statistically analyzed the correlations between pathologic results and imaging findings under the mammography and Tc-99m MIBI scintimammography by chi-square and correlation test. Results: The sensitivity, specificity, positive predictive value, and negative predictive value of mammography for detection of breast cancer were 87.5%, 56.3%, 75.0%), and 75.0% respectively. 45 cases of 80 patients were suspicious for breast cancer under the Tc-99m MIBI scintimammography. 41 cases of 45 patients were confirmed as breast cancer and the remaining 4 cases were confirmed as benign masses. The sensitivity, specificity, positive predictive value and negative predictive value of Tc-99m MIBI scintimammography for detection of breast cancer were 85.4%, 87.5%, 91.1%, and 80.8% respectively. The sensitivity of scintimammography was lower than that of mammography for detection of breast cancer, however the specificity, positive predictive value, and negative predictive value were higher. In the benign mass, the mean T/B ratio in 10 minutes was $1.409{\pm}0.30$, and that in 2 hours was $1.267{\pm}0.42$. The maximal T/B ratio of benign mass in 10 minutes was $1.604{\pm}0.42$, and that in 2 hours was $1.476{\pm}0.50$. In the malignant mass, the mean T/B ratio in 10 minutes was $2.220{\pm}1.07$, and that in 2 hours was $1.842{\pm}0.75$. The maximal T/B ratio of malignant mass was $2.993{\pm}1.94$, and that in 2 hours was $2.480{\pm}1.34$. And the T/B ratio under the early and delayed images were meaningful. Conclusion: The scintimammography is useful diagnostic tool to differentiate breast cancer from benign mass, although the sensitivity of mammography for detection of breast mass is high. Especially, the use of the T/B ratio is helpful to diagnose breast cancer.

The Assessment of Framingham Risk Score and 10 Year CHD Risk according to Application of LDL Cholesterol or Total Cholesterol (LDL Cholesterol 또는 Total Cholesterol의 적용에 따른 Framingham Risk Score와 10년 내 심혈관질환 발생 위험도 평가)

  • Kwon, Se Young;Na, Young Ak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.54-61
    • /
    • 2016
  • Studies on assessment tools for predicting cardiovascular disease risk (CDR), along with the studies to prevent CDR have been consistently reported. The validity of the Framingham risk score (FRS), a commonly known tool, has been verified through the precedent studies. In this study, we examined the differences of FRS according to the application of categories of LDL cholesterol (LDL-C) or Total cholesterol (TC), and attempted to evaluate the agreement of 10 yr CHD risk judgment based on the above-mentioned application. Excluding those diagnosed as cardiovascular diseases, data on subjects (755 men and 775 women) from the 2011 Korean National Health and Nutrition Examination Survey were used. We found differences of FRS and 10 yr CHD risk depending on the application of categories of LDL cholesterol (LDL-C) or Total cholesterol (TC). FRS of TC points were higher than those of LDL-C in both men and women. In classification of low risk (<10%), intermediate risk (10~19%), and high risk (${\geq}20%$), there were disagreements for 106 men and 26 women. Women showed almost perfect agreement from Coefficient of Cohen's Kappa (0.718 in men, and 0.884 in women). In assessment of 10 yr CHD risk, R-squared value from regression including TC was higher than that of LDC-C in both men and women (0.972 vs 0.885). From this result, we can draw a conclusion that correlation coefficients of FRS and CHD risk including TC were higher than those of LDC-C, and women showed a greater degree of agreement than men.

A Consideration of Apron's Shielding in Nuclear Medicine Working Environment (PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰)

  • Lee, Seong-wook;Kim, Seung-hyun;Ji, Bong-geun;Lee, Dong-wook;Kim, Jeong-soo;Kim, Gyeong-mok;Jang, Young-do;Bang, Chan-seok;Baek, Jong-hoon;Lee, In-soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.110-114
    • /
    • 2014
  • Purpose: The advancement in PET/CT test devices has decreased the test time and popularized the test, and PET/CT tests have continuously increased. However, this increases the exposure dose of radiation workers, too. This study aims to measure the radiation shielding rate of $^{18}F-FDG$ with a strong energy and the shielding effect when worker wore an apron during the PET/CT test. Also, this study compared the shielding rate with $^{99m}TC$ to minimize the exposure dose of radiation workers. Materials and Methods: This study targeted 10 patients who visited in this hospital for the PET/CT test for 8 days from May 2nd to 10th 2013, and the $^{18}F-FDG$ distribution room, patient relaxing room (stand by room after $^{18}F-FDG$ injection) and PET/CT test room were chosen as measuring spots. Then, the changes in the dose rate were measured before and after the application of the APRON. For an accurate measurement, the distance from patients or sources was fixed at 1M. Also, the same method applied to $^{99m}TC's$ Source in order to compare the reduction in the dose by the Apron. Results: 1) When there was only L-block in the $^{18}F-FDG$ distribution room, the average dose rate was $0.32{\mu}Sv$, and in the case of L-blockK+ apron, it was $0.23{\mu}Sv$. The differences in the dose and dose rate between the two cases were respectively, $0.09{\mu}Sv$ and 26%. 2) When there was no apron in the relaxing room, the average dose rate was $33.1{\mu}Sv$, and when there was an apron, it was $22.3{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $10.8{\mu}Sv$ and 33%. 3) When there was no APRON in the PET/CT room, the average dose rate was $6.9{\mu}Sv$, and there was an APRON, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $1.4{\mu}Sv$ and 25%. 4) When there was no apron, the average dose rate of $^{99m}TC$ was $23.7{\mu}Sv$, and when there was an apron, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $18.2{\mu}Sv$ and 77%. Conclusion: According to the result of the experiment, $^{99m}TC$ injected into patients showed an average shielding rate of 77%, and $^{18F}FDG$ showed a relatively low shielding rate of 27%. When comparing the sources only, $^{18F}FDG$ showed a shielding rate of 17%, and $^{99m}TC$'s was 77%. Though it had a lower shielding effect than $^{99m}TC$, $^{18}F-FDG$ also had a shielding effect on the apron. Therefore, it is considered that wearing an apron appropriate for high energy like $^{18}F-FDG$ would minimize the exposure dose of radiation workers.

  • PDF

Mineral Contents of Hot Water Extracts and Shell of Shellfishes from Western Coast of Korea (서해안 조개류의 껍질과 열수 추출물의 무기질 함량)

  • 김미정;이예경;김순동
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.11 no.4
    • /
    • pp.289-294
    • /
    • 2001
  • Yields of shells, appearance of the shellfishes, mineral contents of the shells and their hot water extracts were determined in six shellfishes such as corb shell(CS). short neck clam(SNC). taste clam(TC), ark shell(AS). top shell(TS) and oyster(OY) from the western coast of Korea. Yields of shells in shellfishes were 70.I~80.5% but yields of TC was the lowest as 40.7%. The highest among weight of the shell the shellfishes was the TS(26.2g) and the lowest weight was TC(5.6g) Colors of CS, SNC, TC. AS. TS and OY were yellowish brown, brown, black. greenish brown and gray. respectively. Ca content of the shell of shellfishes was 36.23~38.78% and the content of K and Na were 0.23~4.54% and 1.48~l.59%, respectively. Contents of Na, Mg, Fe. Mn, Zn, Cu. P and S were in the range of 0.01~0.21%. It also contained heavy metals, such as Pb(1.90~7.75 ppm), Cd(0.5~4.50 ppm), As (1.40~4.30 ppm), Se (0.2~l.50 ppm). Cr(1.00~8.30 ppm) and Hg(0.002~8.2 ppm), Ca content in hot water extracts of shell of shellfish was the highest in TC(2,448 mg/100 g), and the lowest in SNC(115 mg/100 g). K content in TC extracts was the highest with the levels of 952 mg/100 g. P content of TC and SNC were 201 and 0.36 mg/100 g, respectively. The contents of Pb, As, Se and Cr were the highest in the extracts of TC and were 110. 40. 90, 20 $\mu$g/100 g, respectively. But Cd was not detected in the extracts of SNC.

  • PDF

Comparing of the Administered Activities and the Effective Dose of the Various Pediatric Dose Formulas of Nuclear Medicine (핵의학검사의 방사성의약품 소아투여량 공식 별 투여량 및 유효선량 비교)

  • Gil, Jong-Won
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.147-154
    • /
    • 2017
  • The purpose of this study is to calculate and compare administered activities(MBq) and effective dose(mSv) of the various pediatric dose formulas of pediatric nuclear medicine and to provide base data for the criteria of the optimal administered activities. This study compares dosages and effective doses of 5 types of pediatric dose formulas(Clark rule, Area rule, Webster rule, Young rule, Solomon(Fried) rule) based on the dosage for adults of 2 types of radiopharmaceuticals($^{99m}Tc$-MDP, $^{99m}Tc$-Pertechnetate). The administered activities in adults, which is the criteria for calculating the Pediatric administered activities, used the value from the 'Nuclear Medicine' written by J-G Jeong & M-Ch Lee. and the administered activities by the radioactivity per effective dose(mSv/MBq) of the radiopharmaceuticals for calculating the effective dose used the value from ICRP 80 and the UNSCEAR 2008 Report. As a result of the study, the output of Young rule is the lowest, and its difference between other formulas is from minimum 1.7 times to maximum 3,4 times. The difference between administered activities of $^{99m}Tc$-MDP is maximum 309.9MBq and the effective dose is 3.76mSv. $^{99m}Tc$-Pertechnetate showed the figure at the maximum 154.9MBq and the effective dose has a difference of 5.50mSv. Since the pediatric dose formulas differ not only in administered activities but also in effective doses, the optimal administered activities have to be developed for optimization of medical radiation.

Transport Parameters of 99Tc, 137Cs, 90Sr, and 239+240Pu for Soils in Korea

  • Keum, D.K.;Kim, B.H.;Jun, I.;Lim, K.M.;Choi, Y.H.
    • Journal of Nuclear Fuel Cycle and Waste Technology
    • /
    • v.1 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • To characterize quantitatively the transport of $^{99}Tc$ and the global fallout ($^{137}Cs$, $^{90}Sr$, and $^{239+240}Pu$) for soils in Korea, the transport parameters of a convective-dispersion model, apparent migration velocity, and apparent dispersion coefficient were estimated from the vertical depth profiles of the radionuclides in soils. The vertical profiles of $^{99}Tc$ were measured from a pot experiment for paddy soil that had been sampled from a rice-field around the Gyeongju radioactive waste repository in Korea, and the vertical depth distributions of the global fallout $^{137}Cs$, $^{90}Sr$, and $^{239+240}Pu$ were measured from the soil samples that were taken from local areas in Korea. The front edge of the $^{99}Tc$ profiles reached a depth of about 12 cm in 138 days, indicating a faster movement than the fallout radionuclides. A weak adsorption of $^{99}Tc$ on the soil particles by the formation of Tc(VII) and a high water infiltration velocity seemed to have controlled the migration of $^{99}Tc$. The apparent migration velocity and dispersion coefficient of $^{99}Tc$ for the disturbed paddy soil were 2.88 cm/y and 6.3 $cm^2/y$, respectively. The majority of the global fallout $^{137}Cs$, $^{90}Sr$, and $^{239+240}Pu$ were found in the top 20 cm of the soils even after a transport of about 30 years. The transport parameters for the global fallout radionuclides were 0.01-0.1cm/y ($^{137}Cs$), 0.09-0.13cm/y ($^{90}Sr$), and 0.09-0.18cm/y ($^{239+240}Pu$) for the apparent migration velocity: 0.21-1.09 $cm^2/y$ ($^{137}Cs$), 0.12-0.7$cm^2/y$ ($^{90}Sr$), and 0.09-0.36$cm^2/y$ ($^{239+240}Pu$) for the apparent dispersion coefficient.