• Title/Summary/Keyword: TC10

Search Result 2,138, Processing Time 0.035 seconds

TOPICAL APPLICATION OF TETRACYCLINE GEL IN SCALING AND ROOT PLANING (치석제거 및 치근활택술 시에 테트라싸이클린 젤의 국소적 도포)

  • Han, Soo-Boo;Lee, Jae-Il;Heo, Jeong-Mi;Chang, Mee-Kyung;Shim, Chang-Koo;Lee, Chul-Woo
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.647-658
    • /
    • 1993
  • The purpose of this study is to examine the influence of 5% tetracycline(Tc) gel on healing of gingival tissue and change of diseased root surface when used with nonsurgical procedure. 7 patients with advanced periodontitis were received thorough scaling and root planning, followed by saline irrigation on 10 randomly selected control teeth and Tc gel application for 5 minutes with specifically designed plastic instrument of 10 test teeth in contralateral side. At 0, 1, 7, 14, and 21 days after treatment, biopsy and extraction were carried out. At day 7, Tc group showed decreased inflammation and delayed proliferation of pocket epithelium in comparison with control group which was continued for all experimental days. Scanning electron microscopic finding revealed demineralized and cleaned root surface with exposed dentinal tubules in Tc gel group. In the present study, clinically successful result is expected with combined use of nonsurgical periodontal therapy and intrapocket application of Tc gel.

  • PDF

The development of a portable MO4- (M = 188Re or 99mTc) concentration device for extending the lifetime of RI generators

  • Choi, Kang-Hyuk;Park, Ul Jae;Kim, Jong Bum;Jang, Beom-Su
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.1
    • /
    • pp.3-10
    • /
    • 2019
  • The activities per volume of $^{188}Re$ and $^{99m}Tc$ from their generators are dependent on the specific activity of their mother nuclides $^{188}W$ and $^{99}Mo$ respectively. After a particular lapse of time, the eluted RI activity is exponentially reduced and thus cannot satisfy the needs of clinical application. The purpose of this study is to develop a $^{188}Re$ and $^{99m}Tc$ concentration device with a compact size that can extend the period of use as well as conveniently concentrate the RI. We designed the concentration module by including two-different check valves that do not required any manual on-off operations. In these concentration process, cation exchange resin embedded with Ag and anion exchange resins were used. After completing the concentrating step, the recovering yield was identified to be more than 93% for $^{188}Re$ generators and 88% for $^{99m}Tc$ generators. Moreover, all these procedures were done within 5 min.

Influence of Iodinated Contrast Media and Paramagnetic Contrast Media on Changes in Uptake Counts of 99mTc

  • Cho, Jae-Hwan;Lee, Jin-Hyeok;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Jin;Moon, Deog-Hwan;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to figure out how uptake counts of technetium ($^{99m}Tc$) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. $^{99m}Tc$ isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, $^{99m}Tc$ was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as $Iopamidol^{(R)}$ and $Dotarem^{(R)}$ were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as $Primovist^{(R)}$ and $Gadovist^{(R)}$ were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of $^{99m}Tc$. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of $^{99m}Tc$ were measured (from this procedure). In this study, as a result of measuring the uptake counts of $^{99m}Tc$ using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when $Gadovist^{(R)}$, contrast media for MRI, was used. However, the result of measuring the uptake counts of $^{99m}Tc$ using the pin-hole collimator showed higher uptake counts in all contrast media, except for $Iopamidol^{(R)}$, than normal saline as a reference. The highest uptake counts were measured particularly when $Primovist^{(R)}$, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and $^{99m}Tc$, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.

Induction of Radiation Adaptive Response in Lymphocytes of patients Undergoing Bone Scintigraphy (골 신티그라피를 시행한 환자의 림프구에서 방사선 적응반응의 유도에 관한 연구)

  • Min, Jung-Jun;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.172-177
    • /
    • 1999
  • Purpose: The purpose of this study was to ascertain whether radiation adaptive response could be induced by Tc-99m-methylene diphosphonate (Tc-99m-MDP) in peripheral lymphocytes of patients undergoing bone scintigraphy. Materials and Methods: Lymphocytes from 22 patients (6 males, 16 females, mean age $50{\pm}14$ years) were collected before and after bone scintigraphy using 740 MBq Tc-99m-MDP Lymphocytes from 10 controls (6 males, 4 females, mean age $43{\pm}7$ years) were also collected. They were exposed to challenge dose of 2 Gy gamma rays using a cell irradiator. Number of ring-form and dicentric chromosomes per 600 cells (chromosomal aberrations) was counted under the light microscope. Results: Chromosomal aberrations in patients before bone scintigraphy ($385.1{\pm}30.5$) was not different from that of controls ($367.8{\pm}36.6$). However, chromosomal aberrations in patients after bone scintigraphy was significantly decreased to $192.6{\pm}22.1$ (p=0.0001). Conclusion: Low dose gamma-irradiation by Tc-99m-MDP used for bone scintigraphy induces a cytogenetic adaptive response in peripheral lymphocytes.

  • PDF

Biodistribution of 99mTc Labeled Integrin Antagonist

  • Jang, Beom-Su;Park, Seung-Hee;Shin, In Soo;Maeng, Jin-Soo;Paik, Chang H.
    • Toxicological Research
    • /
    • v.29 no.1
    • /
    • pp.21-25
    • /
    • 2013
  • The selective targeting of an integrin ${\alpha}_v{\beta}_3$ receptor using radioligands may enable the assessment of angiogenesis and integrin ${\alpha}_v{\beta}_3$ receptor status in tumors. The aim of this research was to label a peptidomimetic integrin ${\alpha}_v{\beta}_3$ antagonist (PIA) with $^{99m}Tc(CO)_3$ and to test its receptor targeting properties in nude mice bearing receptor-positive tumors. PIA was reacted with tris-succinimidyl aminotriacetate (TSAT) (20 mM) as a PIA per TSAT. The product, PIA-aminodiacetic acid (ADA), was radiolabeled with $[^{99m}Tc(CO)_3(H_2O)_3]^{+1}$, and purified sequentially on a Sep-Pak C-18 cartridge followed by a Sep-Pak QMA anion exchange cartridge. Using gradient C-18 reverse-phase HPLC, the radiochemical purity of $^{99m}Tc(CO)_3$-ADA-PIA (retention time, 10.5 min) was confirmed to be > 95%. Biodistribution analysis was performed in nude mice (n = 5 per time point) bearing receptor-positive M21 human melanoma xenografts. The mice were administered $^{99m}Tc(CO)_3$-ADA-PIA intravenously. The animals were euthanized at 0.33, 1, and 2 hr after injection for the biodistribution study. A separate group of mice were also co-injected with 200 ${\mu}g$ of PIA and euthanized at 1 hr to quantify tumor uptake. $^{99m}Tc(CO)_3$-ADA-PIA was stable in phosphate buffer for 21 hr, but at 3 and 6 hr, 7.9 and 11.5% of the radioactivity was lost as histidine, respectively. In tumor bearing mice, $^{99m}Tc(CO)_3$-ADA-PIA accumulated rapidly in a receptor-positive tumor with a peak uptake at 20 min, and rapid clearance from blood occurring primarily through the hepatobiliary system. At 20 min, the tumor-to-blood ratio was 1.8. At 1 hr, the tumor uptake was 0.47% injected dose (ID)/g, but decreased to 0.12% ID/g when co-injected with an excess amount of PIA, indicating that accumulation was receptor mediated. These results demonstrate successful $^{99m}TC$ labeling of a peptidomimetic integrin antagonist that accumulated in a tumor via receptor-specific binding. However, tumor uptake was very low because of low blood concentrations that likely resulted from rapid uptake of the agent into the hepatobiliary system. This study suggests that for $^{99m}Tc(CO)_3$-ADA-PIA to be useful as a tumor detection agent, it will be necessary to improve receptor binding affinity and increase the hydrophilicity of the product to minimize rapid hepatobiliary uptake.

Characterizations of Water-dispersed Biocellulose Nanofibers on the Skin Surface (피부 표면에서의 수분산 바이오셀룰로오스 미세섬유의 특성에 대한 연구)

  • Jun, Seung-Hyun;Kim, Seo Yeon;Park, Sun Gyoo;Lee, Cheon Koo;Lee, Seol-Hoon;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.1
    • /
    • pp.89-94
    • /
    • 2018
  • In this study, water-dispersed biocellulose nanofibers (TC) were prepared via an oxidation reaction using 2,2,6,6-tetramethyl-1-piperidine-N-oxy radical (TEMPO) as a catalyst. The TC retained their unique structure in water as well as in emulsion. TC adhered to the skin surface while maintaining nanofibrous structures, providing inherent functions of biocellulose, such as high tensile strength and high water-holding capacity. When gelatin gels as model skin were coated with TC, the hardness representing the elasticity was increased by 20% compared to untreated gelatin gel because TC could tightly hold the gelatin structure. When porcine skin was treated with TC and TC-contained O/W emulsion, the initial water contact angles of TC were lower than other materials, and dramatically decreased over time as water penetrated the fibrous structure of the TC film. Characterization of TC on the skin surface offered insight into the function of nanofibers on the skin, which is important for their applications with respect to fiber-cosmetics.

Relationship Among Serum Lipid levels, Obesity and Blood Pressure in Health Examined Adult Women (건강검진 수진 성인 여성의 혈청지질과 비만 및 혈압과의 관련성)

  • Park, Sung-Kyeong;Cho, Young-Chae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4342-4348
    • /
    • 2013
  • The present study was intended to reveal the relationships between serum lipid levels and various factors of obesity and blood pressure. The study subjects were 1,838 adult women measured at a mass health screening during the period from January through December, 2011. TC, TG, HDL-C, LDL-C, SBP, DBP, degree of obesity, body fat rate were measured and the relation between these obesity and blood pressure measurements to serum lipid levels were studied. As a results, TC, TG, LDL-C, body fat rate and degree of obesity increased linearly with advancing age. TC, TG and LDL-C increased linearly with increasing blood pressure, and these values were higher in hypertension group than that of normal group. TC, TG and SBP increased linearly with increasing degree of obesity, and these values were higher in obesity group than that of normal group. HDL-C decreased linearly with increasing degree of obesity, and these values were lower in obesity group than that of normal group. TC, TG, HDL-C, degree of obesity, body fat rate was positive correlation with each others, but these values negatively correlated to HDL-C. Principal component analysis, showed that subjects could be divided into the group having the hypertensive group(1st principal component), the obesity group(2nd principal component), the hyperlipidemia group(3rd principal component), and HDL-C(4th principal component). In multiple regression analysis, age, TC, TG and body fat rate were affected to HDL-C. Above results suggest that higher the degree of obesity and blood pressure, the higher the serum lipid levels.

Labeling Efficiency of $^{99m}Tc$-Labeled RBC Due to Labeling Time Change (표지시간 변화에 의한 $^{99m}Tc$과 적혈구 표지효율)

  • Dong, Kyeong-Rae;Kim, Ho-Seong;Choi, Seong-Kwan
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.259-263
    • /
    • 2007
  • For the preparation of $^{99m}Tc$-labeled RBC, $10{\sim}20\;{\mu}g/kg$ of Stannous(II) chloride and $10{\sim}40\;min$ of preparation was used. For finding out the effect of contrast agent, the blood samples were collected in three days, seven days, and 1 months after the diagnostic procedure. In the normal volunteer, the concentration of reducing agent and preparation time did not effect on the radiochemical yield. But in the patients, 10 mg of Stannous(II) chloride and 60 min incubation times was shown high radiochemical yield. Contrast agent has a significant effect on the radiochemical yield. Although the blood samples which were collected after seven days of diagnostic procedure did not effect on the radiochemical yield of $^{99m}Tc$-labeled RBC, but the radiochemical yield of $^{99m}Tc$-labeled RBC which was prepared with a sample of high concentration of contrast agent in blood led to low radiochemical yield. For these samples, the modified method showed high radiochemical yield than previous in vivo preparation method. The recommended method is followed. Blood collecting was performed at 30 minutes after injection of reducing agent, and it is centrifuged for removal of plasma. After addition of $^{99m}TcO^-_4$, sample reservoir was rotated. After addition of normal saline, and it is centrifuged for separation of saline. Then $^{99m}Tc$-labeled RBC was obtained after removal of saline.

  • PDF

International Standards Activities for ISO/TC 112 Vacuum Technology (ISO/TC 112 Vacuum Technology 국제표준 활동)

  • Hong, S.S.;Shin, Y.H.;Kim, J.T.;Chung, K.H.;Choi, H.K.;Kim, I.S.;Park, W.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.397-404
    • /
    • 2007
  • International Standardization for Vacuum pumps, vacuum instruments, and vacuum components has been established at ISO/TC 112 which is a technical committee of ISO (International Organization for Standardization) in the area of vacuum technology. This report shortly summarizes the structure of ISO/TC 112 and its activities on the standardization for vacuum technology. Also it introduces the brief contents of "specifications for hot cathode ionization gauges" and"Test procedure for vacuum valves" which are recently accepted as new proposals. These information on ISO/TC 112 would contribute to activate the development of vacuum technology as well as the participation for the international standardization in Korea.

Characterization of Tetracycline-Resistant Genes of Staphylococci isolates from Human and Marine Environment (사람과 해양환경에서 분리된 Staphylococci의 Tetracycline 내성 유전자의 특성 비교)

  • CHO, Ki-Taek;KIM, Young-Chul;KWON, Woo-Ju;JEONG, Hyun-Do
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.1
    • /
    • pp.59-68
    • /
    • 2016
  • For comparison of tetracycline-resistant ($Tc^R$) genes, we obtained 21 and 14 $Tc^R$ Staphylococcus spp. from marine environment and human patient, respectively. Although all isolates from human were identified as Staphylococcus aureus, higher proportion of $Tc^R$ isolates (12 out of 14) from human were utilizing tet(M) gene compared to that of $Tc^R$ isolates (6 out of 21) from marine environment. Additionally, collaborated utilization of tet(M) and erm(A) in $Tc^R-Em^R$ S. aureus in human patient, but not in $Tc^R$ Staphylococcus spp. isolates from marine environment was also characterized. Based on the nucleotide sequence of transposon related to $Tc^R$ gene, we confirmed the origin of tet(M) gene in $Tc^R$ Staphylococci isolated from marine environments and human are derived from Tn916/1545-like and Tn5801 transposon, respectively. It is the first report showing the presence of Tn5801 in all $Tc^R$ S. aureus carrying tet(M) in human patient. Alignment of the fully sequenced tet(M) from marine environmental isolates was also agreed with the determined transposons by showing the genomic mosaic structure composed with three genomic parts from Tn916/1545 and unknown transposons. Genetic characteristics of these tet(M) in environmental isolates were similar to each other but different from those in isolates from human showing only tet(M) from Tn916/5801 type. It may imply the presence of less dramatic communication of antibiotic resistant genes between Staphylococci isolated from marine environment and human.